Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
BMC Oral Health ; 18(1): 181, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30382850

RESUMEN

BACKGROUND: Traditionally, dental implants have been made from titanium or titanium alloys. Alternatively, zirconia-based ceramic implants have been developed with similar characteristics of functional strength and osseointegration. Ceramic implants offer advantages in certain settings, e.g. in patients who object to metal dental implants. The aim of this study was to investigate the mid-term (36 months) clinical performance of a ceramic monotype implant in single-tooth edentulous area. METHODS: This was a prospective, open-label, single-arm study in patients requiring implant rehabilitation in single-tooth edentulous area. Ceramic implants (PURE Ceramic Implant, Institut Straumann AG, Basel, Switzerland) with a diameter of 4.1 mm were placed following standard procedure and loaded with provisional and final prostheses after 3 and 6 months, respectively. Implant survival rate and implant success rate were evaluated and crestal bone levels were measured by analysing standardized radiographs during implant surgery and at 6, 12, 24 and 36 months. RESULTS: Forty-four patients received a study implant, of whom one patient withdrew consent after 3 months. With one implant lost during the first 6 months after surgery, the implant survival rate was 97.7% at 6 months. No further implants were lost over the following 30 months, and 3 patients were lost to follow-up during this time frame. This led to a survival rate of 97.5% at 36 months. Six months after implant surgery 93.0% of the implants were considered "successful", increasing to 97.6% at 12 months and remaining at this level at 24 months (95.1%) and 36 months (97.5%). Bone loss was most pronounced in the first half-year after implant surgery (0.88 ± 0.86 mm). By contrast, between 12 and 36 months the mean bone level remained stable (minimal gain of 0.06 [± 0.60] mm). Hence, the overall bone loss from implant surgery to 36 months was 0.97 (± 0.88) mm. CONCLUSIONS: In the follow-up period ceramic implants can achieve favourable clinical outcomes on a par with titanium implants. For instance, these implants can be recommended for patients who object to metal dental implants. However, longer term studies with different edentulous morphology need to confirm the present data. TRIAL REGISTRATION: Registered on www.clinicaltrials.gov : NCT02163395 .


Asunto(s)
Implantación Dental Endoósea/métodos , Implantes Dentales de Diente Único , Femenino , Estudios de Seguimiento , Humanos , Arcada Parcialmente Edéntula/rehabilitación , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Circonio
2.
PLoS One ; 13(4): e0195822, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29672626

RESUMEN

BACKGROUND: Respiratory viruses such as respiratory syncytial virus (RSV) or rhinovirus are one of the major causes for respiratory tract infections causing common cold disease. Respiratory viral infections range from mild symptoms in adults to serious illness especially in the very young or elderly as well as patients suffering from lung diseases or being immunocompromised due to other reasons. Engystol (EGY-2) is a multicomponent, multitarget preparation consisting of Vincetoxicum hirundinaria and Sulfur in various dilutions. The study objective was to test the effect of EGY-2 on the innate immune response during the early onset of respiratory viral infection in vivo as exemplified in a mouse model of RSV-induced respiratory inflammation. METHODS: Naïve BALB/c mice were infected with 1x106 infectious units RSV A2 intranasally to cause a mild respiratory infection. EGY-2 was administered daily per oral gavage starting seven days prior to RSV infection at doses of 0.4 to 5.1 tablets/kg. Control groups received placebo treatment. Animals were sacrificed 1 to 3 days post infection (p.i.) to analyse the infection and induced immune response in the lung. Viral load in bronchoalveolar lavage fluid (BALF) and lung homogenate was determined by TCID50 assay as well as immunofluorescence staining of BALF cells using anti-RSV antibody and microscopic analysis. The RSV induced immune response was assessed by evaluation of BALF differential cell count, BALF cytokine secretion and analysis of the phagocytic capacity of alveolar macrophages. RESULTS: EGY-2 significantly reduced the RSV induced neutrophil and early lymphocyte influx on day 1 p.i. in BALF. EGY-2 treatment significantly diminished the RSV induced secretion of pro-inflammatory cytokines such as IFN-γ, IL-1ß, IL-6, KC and TNF-α at day 1. EGY-2 treatment was not protective for RSV infection per se, as no alteration in the viral load in lung and BALF was detected. Enhanced numbers of phagocytic-active macrophages were observed in EGY-2 treated animals on day 1 and this macrophage population showed strongly enhanced phagocytic activity on day 1 and day 3. CONCLUSION: The data suggest a beneficial immunomodulatory effect of EGY-2 during early onset of respiratory viral infection in vivo, mediated by stimulation of macrophage phagocytosis, resulting in a reduced innate inflammatory response in terms of neutrophil and early lymphocyte infiltration as well as reduced inflammatory cytokine secretion.


Asunto(s)
Macrófagos/efectos de los fármacos , Macrófagos/inmunología , Fagocitosis/efectos de los fármacos , Fagocitosis/inmunología , Extractos Vegetales/farmacología , Infecciones por Virus Sincitial Respiratorio/inmunología , Infecciones por Virus Sincitial Respiratorio/virología , Virus Sincitiales Respiratorios/inmunología , Animales , Líquido del Lavado Bronquioalveolar/inmunología , Citocinas/metabolismo , Modelos Animales de Enfermedad , Femenino , Activación de Macrófagos/efectos de los fármacos , Activación de Macrófagos/inmunología , Macrófagos/metabolismo , Macrófagos Alveolares/efectos de los fármacos , Macrófagos Alveolares/inmunología , Macrófagos Alveolares/metabolismo , Macrófagos Alveolares/patología , Ratones , Infiltración Neutrófila/efectos de los fármacos , Infiltración Neutrófila/inmunología , Neutrófilos/efectos de los fármacos , Neutrófilos/inmunología , Neutrófilos/metabolismo , Neutrófilos/patología , Infecciones por Virus Sincitial Respiratorio/tratamiento farmacológico , Infecciones por Virus Sincitial Respiratorio/metabolismo , Carga Viral
3.
Clin Oral Implants Res ; 27(12): e176-e184, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25827600

RESUMEN

INTRODUCTION: Dental implants have traditionally been made from titanium or its alloys, but recently full-ceramic implants have been developed with comparable osseointegration properties and functional strength properties to titanium. These ceramic implants may have advantages in certain patients and situations, for example, where esthetic outcomes are particularly important. OBJECTIVE: The objective of this investigation was to evaluate the performance of a newly developed full-ceramic ZrO2 monotype implant design (PURE Ceramic Implant; Institut Straumann AG, Basel, Switzerland) in single-tooth gaps in the maxilla and mandible. MATERIAL AND METHODS: This was a prospective, open-label, single-arm study in patients requiring implant rehabilitation in single-tooth gaps. Full-ceramic implants were placed, with provisional and final prostheses inserted after 3 and 6 months, respectively. Crestal bone level was measured at implant placement and after 6 and 12 months. Implant survival and success were evaluated after 6 and 12 months. Further evaluations are planned after 24 and 36 months. RESULTS: Forty-six patients were screened for potential study participation, of whom 44 (17 men and 27 women, mean age 48 ± 14 years) were recruited into the study. The majority of implants (90.9%) were placed in the maxilla. The implant survival and implant success rate after 12 months were 97.6%. A minor change of the mean bone level occurred between implant loading (final prosthesis insertion after 6 months) and 12 months (-0.14 mm) after initial bone remodeling was observed between implant placement and loading (-0.88 mm). CONCLUSIONS: The results indicated that monotype ceramic implants can achieve clinical outcomes comparable to published outcomes of equivalent titanium implants.


Asunto(s)
Implantación Dental Endoósea/métodos , Materiales Dentales , Circonio , Diseño de Prótesis Dental , Estética Dental , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oseointegración , Estudios Prospectivos