Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Clin Pathol ; 77(6): 430-434, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38429092

RESUMEN

We demonstrate a method for tissue microdissection using scanning laser ablation that is approximately two orders of magnitude faster than conventional laser capture microdissection. Our novel approach uses scanning laser optics and a slide coating under the tissue that can be excited by the laser to selectively eject regions of tissue for further processing. Tissue was dissected at 0.117 s/mm2 without reduction in yield, sequencing insert size or base quality compared with undissected tissue. From eight cases, 58-416 mm2 of tissue was obtained from one to four slides in 7-48 seconds total dissection time per case. These samples underwent exome sequencing and we found the variant allelic fraction increased in regions enriched for tumour as expected. This suggests that our ablation technique may be useful as a tool in both clinical and research labs.


Asunto(s)
Captura por Microdisección con Láser , Humanos , Captura por Microdisección con Láser/métodos , Terapia por Láser/métodos , Microdisección/métodos , Secuenciación del Exoma , Factores de Tiempo
2.
J Pathol ; 253(2): 225-233, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33135777

RESUMEN

The practical application of genome-scale technologies to precision oncology research requires flexible tissue processing strategies that can be used to differentially select both tumour and normal cell populations from formalin-fixed, paraffin-embedded tissues. As tumour sequencing scales towards clinical implementation, practical difficulties in scheduling and obtaining fresh tissue biopsies at scale, including blood samples as surrogates for matched 'normal' DNA, have focused attention on the use of formalin-preserved clinical samples collected routinely for diagnostic purposes. In practice, such samples often contain both tumour and normal cells which, if correctly partitioned, could be used to profile both tumour and normal genomes, thus identifying somatic alterations. Here we report a semi-automated method for laser microdissecting entire slide-mounted tissue sections to enrich for cells of interest with sufficient yield for whole genome and transcriptome sequencing. Using this method, we demonstrated enrichment of tumour material from mixed tumour-normal samples by up to 67%. Leveraging new methods that allow for the extraction of high-quality nucleic acids from small amounts of formalin-fixed tissues, we further showed that the method was successful in yielding sequence data of sufficient quality for use in BC Cancer's Personalized OncoGenomics (POG) program. © 2020 The Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.


Asunto(s)
Captura por Microdisección con Láser , Neoplasias/patología , Medicina de Precisión , Animales , Formaldehído , Humanos , Hígado/patología , Ratones , Ratones Endogámicos C57BL , Fijación del Tejido
3.
Trends Cancer ; 5(3): 157-169, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30898263

RESUMEN

Deep learning refers to a set of computer models that have recently been used to make unprecedented progress in the way computers extract information from images. These algorithms have been applied to tasks in numerous medical specialties, most extensively radiology and pathology, and in some cases have attained performance comparable to human experts. Furthermore, it is possible that deep learning could be used to extract data from medical images that would not be apparent by human analysis and could be used to inform on molecular status, prognosis, or treatment sensitivity. In this review, we outline the current developments and state-of-the-art in applying deep learning for cancer diagnosis, and discuss the challenges in adapting the technology for widespread clinical deployment.


Asunto(s)
Aprendizaje Profundo , Aprendizaje Automático , Neoplasias/diagnóstico , Inteligencia Artificial , Humanos , Procesamiento de Imagen Asistido por Computador , Inmunohistoquímica , Redes Neurales de la Computación , Tomografía Computarizada por Rayos X , Flujo de Trabajo
4.
Can Assoc Radiol J ; 70(1): 74-82, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30691567

RESUMEN

PURPOSE: 3-D printing is an increasingly widespread technology that allows physical models to be constructed based on cross-sectional medical imaging data. We sought to develop a pipeline for production of 3-dimensional (3-D) models for presurgical planning and assess the value of these models for surgeons and patients. METHODS: In this institutional review board-approved, single-center case series, participating surgeons identified cases for 3-D model printing, and after obtaining patient consent, a 3-D model was produced for each of the 7 participating patients based on preoperative cross-sectional imaging. Each model was given to the surgeon to use during the surgical consent discussion and preoperative planning. Patients and surgeons completed questionnaires evaluating the quality and usefulness of the models. RESULTS: The 3-D models improved surgeon confidence in their operative approach, influencing the choice of operative approach in the majority of cases. Patients and surgeons reported that the model improved patient comprehension of the surgery during the consent discussion, including risks and benefits of the surgery. Model production time was as little as 4 days, and the average per-model cost was $350. CONCLUSIONS: 3-D printed models are useful presurgical tools from both surgeon and patient perspectives. Development of local hospital-based 3-D printing capabilities enables model production with rapid turnaround and modest cost, representing a value-added service for radiologists to offer their surgical colleagues.


Asunto(s)
Toma de Decisiones Clínicas/métodos , Huesos Faciales/cirugía , Reconstrucción Mandibular/métodos , Cuidados Preoperatorios/métodos , Impresión Tridimensional , Adulto , Colombia Británica , Huesos Faciales/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Adulto Joven
5.
J Biomed Opt ; 21(12): 126011, 2016 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-27999860

RESUMEN

Current diagnostic capabilities and limitations of fluorescence endomicroscopy in the cervix are assessed by qualitative and quantitative image analysis. Four cervical tissue types are investigated: normal columnar epithelium, normal and precancerous squamous epithelium, and stromal tissue. This study focuses on the perceived variability within and the subtle differences between the four tissue groups in the context of endomicroscopic in vivo pathology. Conclusions are drawn on the general ability to distinguish and diagnose tissue types, on the need for imaging depth control to enhance differentiation, and on the possible risks for diagnostic misinterpretations.


Asunto(s)
Cuello del Útero/citología , Cuello del Útero/diagnóstico por imagen , Microscopía Confocal/métodos , Microscopía Fluorescente/métodos , Células Epiteliales/citología , Diseño de Equipo , Femenino , Humanos , Proyectos Piloto , Lesiones Intraepiteliales Escamosas de Cuello Uterino/diagnóstico por imagen
6.
Injury ; 47(10): 2195-2202, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27496724

RESUMEN

OBJECTIVES: We hypothesize that inserting a curved intramedullary internal fixation device which follows curved osseous fixation paths (OFPs) would be more versatile and mechanically stronger than straight screws for fixation of pelvic ring and acetabular injuries. This study characterizes the dimensions of curved OFPs of the pelvic ring and acetabulum and suggests design parameters for such a curved device. METHODS: CT scans of intact pelves of 50 female and 50 male subjects were studied using MIM Maestro™ and Solidworks™ to determine the constriction points (smallest cross sections) and the tightest radii of curvature (RoC) in the anterior column, posterior column, iliosacral and pubic symphysis OFPs. RESULTS: The constriction point diameters for the superior pubic ramus and supra-acetabular areas were 13±3mm and 12±3mm, respectively. The anterior column RoC was greater than 65mm in all cases. The minimum observed RoC for the path from one ilium, across the SI joint, the sacrum and to the other ilium was 71mm, with 99% of the cases having a RoC of at least 80mm, in both the inlet and outlet views. CONCLUSION: This study shows that if a flexible implant which could be stiffened once in place was available, it would enable the use of larger and longer fixation taking advantage of the pelvis's curved intracortical spaces. Even for dysmorphic pelves, accessible tunnels support a long, strong, curved fixation device.


Asunto(s)
Diseño de Equipo/instrumentación , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Huesos Pélvicos/anatomía & histología , Tornillos Óseos , Estudios de Factibilidad , Femenino , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Humanos , Fijadores Internos , Masculino , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/cirugía , Valores de Referencia , Tomografía Computarizada por Rayos X
7.
Sensors (Basel) ; 14(7): 12399-409, 2014 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-25014100

RESUMEN

This paper reports a method that enables real-time displacement monitoring and control of micromachined resonant-type actuators using wireless radiofrequency (RF). The method is applied to an out-of-plane, spiral-coil microactuator based on shape-memory-alloy (SMA). The SMA spiral coil forms an inductor-capacitor resonant circuit that is excited using external RF magnetic fields to thermally actuate the coil. The actuation causes a shift in the circuit's resonance as the coil is displaced vertically, which is wirelessly monitored through an external antenna to track the displacements. Controlled actuation and displacement monitoring using the developed method is demonstrated with the microfabricated device. The device exhibits a frequency sensitivity to displacement of 10 kHz/µm or more for a full out-of-plane travel range of 466 µm and an average actuation velocity of up to 155 µm/s. The method described permits the actuator to have a self-sensing function that is passively operated, thereby eliminating the need for separate sensors and batteries on the device, thus realizing precise control while attaining a high level of miniaturization in the device.


Asunto(s)
Espectroscopía de Resonancia Magnética/instrumentación , Tecnología Inalámbrica/instrumentación , Diseño de Equipo/instrumentación , Campos Magnéticos , Microtecnología/instrumentación , Miniaturización/instrumentación , Ondas de Radio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...