Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
1.
J Clin Med ; 13(11)2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38892985

RESUMEN

Objectives: In recent years, minimally invasive approaches have been used with increasing frequency, even for more complex aortic procedures. However, evidence on the practicability and safety of expanding minimally invasive techniques from isolated operations of the ascending aorta towards more complex operations such as the hemiarch replacement is still scarce to date. Methods: A total of 86 patients undergoing elective surgical replacement of the ascending aorta with (n = 40) or without (n = 46) concomitant proximal aortic arch replacement between 2009 and 2023 were analyzed in a retrospective single-center analysis. Groups were compared regarding operation times, intra- and postoperative complications and long-term survival. Results: Operation times and ventilation times were significantly longer in the hemiarch replacement group. Despite this, no statistically significant differences between the two groups were observed for the duration of the ICU and hospital stay and postoperative complication rates. At ten-year follow-up, overall survival was 82.6% after isolated ascending aorta replacement and 86.3% after hemiarch replacement (p = 0.441). Conclusions: Expanding the indication for minimally invasive aortic surgery towards the proximal aortic arch resulted in comparable postoperative complication rates, length of hospital stay and overall long-term survival compared to the well-established minimally invasive isolated supracommissural ascending aorta replacement.

2.
J Clin Med ; 13(11)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38893048

RESUMEN

Background: Coronary artery disease is a major cause of death globally. Minimally invasive direct coronary artery bypass (MIDCAB), using a small left anterior thoracotomy, aims to provide a less invasive alternative to traditional procedures, potentially improving patient outcomes with reduced recovery times. Methods: This retrospective, non-randomized study analyzed 310 patients who underwent MIDCAB between July 1999 and April 2022. Data were collected on demographics, clinical characteristics, operative and postoperative outcomes, and follow-up mortality and morbidity. Statistical analysis was conducted using IBM SPSS, with survival curves generated via the Kaplan-Meier method. Results: The cohort had a mean age of 63.3 ± 10.9 years, with 30.6% females. The majority of surgeries were elective (76.1%), with an average operating time of 129.7 ± 35.3 min. The median rate of intraoperative blood transfusions was 0.0 (CI 0.0-2.0) Units. The mean in-hospital stay was 8.7 ± 5.5 days, and the median ICU stay was just one day. Early postoperative complications were minimal, with a 0.64% in-hospital mortality rate. The 6-month and 1-year mortalities were 0.97%, with a 10-year survival rate of 94.3%. There were two cases of perioperative myocardial infarction and no instances of stroke or new onset dialysis. Conclusions: The MIDCAB approach demonstrates significant benefits in terms of patient recovery and long-term outcomes, offering a viable and effective alternative for patients suitable for less invasive procedures. Our results suggest that MIDCAB is a safe option with favorable survival rates, justifying its consideration in high-volume centers focused on minimally invasive techniques.

3.
Diagnostics (Basel) ; 14(12)2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38928674

RESUMEN

BACKGROUND/OBJECTIVES: Infective prosthesis endocarditis (IE) following transcatheter aortic valve implantation (TAVI) presents significant management challenges, marked by high mortality rates. This study reviews our center's experience with surgical interventions for IE in patients post-TAVI, focusing on outcomes, challenges, and procedural complexities, and providing an overview of the limited literature surrounding this subject. METHODS: This study was executed as a comprehensive retrospective analysis, targeting the clinical outcomes of surgical treatment in patients presenting with PVE following TAVI procedures at our institution. From July 2017 to July 2022, we identified five patients who had previously undergone transfemoral transcatheter aortic valve implantation and were later diagnosed with PVE needing surgery, strictly adhering to the modified Duke criteria. RESULTS: All surgical procedures were reported successful with no intra- or postoperative mortality. Patients were predominantly male (80%), with an average age of 76 ± 8.6 years, presenting mostly with dyspnea (NYHA Class II). The mean follow-up was between 121 and 1973 days, with outcomes showing no occurrences of stroke, myocardial infarction, or major bleeding. One patient expired from unrelated causes 3.7 years post-surgery. The operative and postoperative protocols demonstrated effective disease management with enhanced survival and minimal complications. CONCLUSIONS: The surgical treatment of IE following TAVI, though challenging, can be successfully achieved with careful patient selection and a multidisciplinary approach. The favorable outcomes suggest that surgical intervention remains a viable option for managing this high-risk patient group. Our study also highlights the scarce literature available on this topic, suggesting an urgent need for more comprehensive research to enhance understanding and improve treatment strategies. Future studies with larger cohorts are needed to further validate these findings and refine surgical strategies for this growing patient population.

4.
Artif Organs ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38803239

RESUMEN

BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.

5.
ASAIO J ; 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38569184

RESUMEN

Severe right heart failure, often overlooked and challenging to manage, has prompted a growing interest in innovative approaches to provide functional support. This study uses experimentation in large porcine models to introduce a novel prototype of a pulsatile mechanical circulatory support device and document its effects when deployed as a right ventricular assist device (RVAD). The pulsatile ventricular assist platform (pVAP), featuring a membrane pump driven by an intra-aortic balloon pump console, actively generates pulsatile flow to propel right ventricular blood into the pulmonary artery. This novel prototype demonstrates promising potential in addressing the challenges of right heart failure management. After preliminary in vitro assessments, the pVAP was tested on seven porcine models in a healthy state and after the induction of right ventricular failure. During the procedure, a set of standard (ie, standard-of-care) hemodynamic measurements was obtained. Additionally, invasive pressure-volume loop analysis was employed to examine left ventricular hemodynamics. Results indicated that activation of the pVAP during right ventricular failure significantly improved systemic hemodynamics and enhanced left ventricular function. This study sheds light on the potential of the pVAP in managing right heart failure.

6.
Innovations (Phila) ; 19(2): 196-203, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38576096

RESUMEN

In the evolving landscape of cardiac surgery, this article explores the potential of minimally invasive mitral valve replacement procedures as a viable alternative to conventional surgical techniques. Leveraging advancements in automated suturing devices and video endoscopy, our work aims to demonstrate that minimally invasive approaches can be applied across a broad spectrum of surgical scenarios. Herein we highlight preoperative diagnostics and operative techniques, with a focus on infra-axillary anterolateral minithoracotomy as the access point. Our technique utilizes technology from LSI SOLUTIONS® (Victor, NY, USA), including the RAM® Device for automated suturing, which has an ergonomic design and safety features. The device's capabilities are further enhanced by the SEW-EASY® Device, the RAM® RING, and the COR-KNOT MINI® Device, which streamline suture management and securement. This work outlines how these technological advancements can mitigate concerns about technical complexity and learning curves, thereby encouraging wider adoption of minimally invasive techniques. Clinical benefits may include reduced surgical trauma, quicker recovery, and cost-effectiveness, making it a compelling option in an era of aggressively promoted transcatheter interventions.


Asunto(s)
Endoscopía , Implantación de Prótesis de Válvulas Cardíacas , Procedimientos Quirúrgicos Mínimamente Invasivos , Válvula Mitral , Técnicas de Sutura , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Técnicas de Sutura/instrumentación , Endoscopía/métodos , Endoscopía/instrumentación , Toracotomía/métodos
7.
Front Cardiovasc Med ; 11: 1344292, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38545343

RESUMEN

Intraluminal thrombus formation (ILT) is a recently discovered and highly clinically relevant complication after frozen elephant trunk implantation in cardiovascular surgery. In this phenomenon, a thrombus forms within the lumen of the stent graft component of the frozen elephant trunk prosthesis and puts the patient at risk for downstream embolization with visceral or lower limb ischemia. Incidence of ILT reported in the currently available studies ranges from 6% to 17% of patients after frozen elephant trunk implantation. Adverse thromboembolic events include acute occlusion of the celiac and superior mesenteric arteries, both renal arteries as well as acute lower limb ischemia due to iliac or femoral artery embolization that not infrequently require interventional or open embolectomy. Therefore, the presence of ILT is associated with increased short-term mortality and morbidity. Currently proposed strategies to avoid ILT formation include a more aggressive anticoagulation management, minimization of postoperative coagulation factor application, and even technical optimizations of the stent graft portion itself. If ILT is manifested, the therapeutic strategies tested to date are long-term escalation of anticoagulation and early endovascular extension of the FET stent graft with overstenting of the intraluminal thrombus. The long-term efficiency of these prophylactic and therapeutic measures has yet to be proven. Nonetheless, all surgeons performing the frozen elephant trunk procedure must be aware of the risk of ILT formation to facilitate a timely diagnosis and therapy.

8.
J Clin Med ; 13(3)2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38337526

RESUMEN

BACKGROUND: Intercostal artery reinsertion (ICAR) during thoracoabdominal aortic replacement remains controversial. While some groups recommend the reinsertion of as many arteries as possible, others consider the sacrifice of multiple intercostals practicable. This study investigates the impact of intercostal artery reinsertion or sacrifice on neurological outcomes and long-term survival after thoracoabdominal aortic repair. METHODS: A total of 349 consecutive patients undergoing thoracoabdominal aortic replacement at our institution between 1996 and 2021 were analyzed in a retrospective single-center study. ICAR was performed in 213 patients, while all intercostal arteries were ligated and sacrificed in the remaining cases. The neurological outcome was analyzed regarding temporary and permanent paraplegia or paraparesis. RESULTS: No statistically significant differences were observed between the ICAR and non ICAR groups regarding the cumulative endpoint of transient and permanent spinal cord-related complications (12.2% vs. 11.8%, p = 0.9). Operation, bypass, and cross-clamp times were significantly longer in the ICAR group. Likewise, prolonged mechanical ventilation was more often necessary in the ICAR group (26.4% vs. 16.9%, p = 0.03). Overall long-term survival was similar in both groups in the Kaplan-Meier analysis. CONCLUSION: Omitting ICAR during thoracoabdominal aortic replacement may reduce operation and cross-clamp times and thus minimize the duration of intraoperative spinal cord hypoperfusion.

10.
Artif Organs ; 48(4): 356-364, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38010063

RESUMEN

BACKGROUND: Infective endocarditis (IE) poses a significant health risk, especially in patients with prosthetic heart valves. Despite advances in treatment, mortality rates remain high. This study aims to investigate the antibacterial properties of a copper titanium dioxide (4× Cu-TiO2) coating on cardiovascular implants against Staphylococcus aureus, a common causative agent of IE. METHODS: Titanium oxide carriers functionalized with copper ions were employed as an antibacterial coating for heart and vascular prostheses. The coating's antibacterial efficacy was assessed using S. aureus ATCC 29213. Microscopic evaluations were conducted on both biological and artificial materials. Antibacterial activity was qualitatively assessed via a modified disc diffusion method and quantitatively measured through colony counts in NaCl suspensions. RESULTS: The coating process was successfully applied to all tested cardiovascular prosthetic materials. Qualitative assessments of antibacterial effectiveness revealed an absence of bacterial growth in the area directly beneath the coated valve. Quantitative evaluations showed a significant reduction in bacterial colonization on coated mechanical valves, with 2.95 × 104 CFU per valve, compared to 1.91 × 105 CFU in control valves. CONCLUSIONS: The 4× Cu-TiO2 coating demonstrated promising antibacterial properties against S. aureus, suggesting its potential as an effective strategy for reducing the risk of bacterial colonization of cardiovascular implants. Further studies are needed to assess the longevity of the coating and its efficacy against other pathogens.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Humanos , Cobre , Staphylococcus aureus , Proyectos Piloto , Materiales Biocompatibles Revestidos , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Prótesis e Implantes , Endocarditis Bacteriana/prevención & control , Titanio
12.
Artif Organs ; 48(1): 16-27, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37822301

RESUMEN

BACKGROUND: The management of concomitant valvular lesions in patients undergoing left ventricular assist device (LVAD) implantation remains a topic of debate. This systematic review and meta-analysis aimed to evaluate the existing evidence on postoperative outcomes following LVAD implantation, with and without concomitant MV surgery. METHODS: A systematic database search was conducted as per PRISMA guidelines, of original articles comparing LVAD alone to LVAD plus concomitant MV surgery up to February 2023. The primary outcomes assessed were overall mortality and early mortality, while secondary outcomes included stroke, need for right ventricular assist device (RVAD) implantation, postoperative mitral valve regurgitation, major bleeding, and renal dysfunction. RESULTS: The meta-analysis included 10 studies comprising 32 184 patients. It revealed that concomitant MV surgery during LVAD implantation did not significantly affect overall mortality (OR:0.83; 95% CI: 0.53 to 1.29; p = 0.40), early mortality (OR:1.17; 95% CI: 0.63 to 2.17; p = 0.63), stroke, need for RVAD implantation, postoperative mitral valve regurgitation, major bleeding, or renal dysfunction. These findings suggest that concomitant MV surgery appears not to confer additional benefits in terms of these clinical outcomes. CONCLUSION: Based on the available evidence, concomitant MV surgery during LVAD implantation does not appear to have a significant impact on postoperative outcomes. However, decision-making regarding MV surgery should be individualized, considering patient-specific factors and characteristics. Further research with prospective studies focusing on specific patient populations and newer LVAD devices is warranted to provide more robust evidence and guide clinical practice in the management of valvular lesions in LVAD recipients.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Enfermedades Renales , Insuficiencia de la Válvula Mitral , Accidente Cerebrovascular , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Hemorragia/complicaciones , Enfermedades Renales/complicaciones , Estudios Retrospectivos
13.
Life (Basel) ; 13(10)2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37895427

RESUMEN

Mechanical circulatory support has proven effective in managing postcardiotomy cardiogenic shock by stabilizing patients' hemodynamics and ensuring adequate organ perfusion. Among the available device modalities, the combination of extracorporeal life support and a microaxial flow pump for left ventricular unloading has emerged as a valuable tool in the surgical armamentarium. In this publication, we provide recommendations for the application and weaning of temporary mechanical circulatory support in cardiogenic shock patients, derived from a consensus among leading cardiac centers in German-speaking countries.

15.
Mediastinum ; 7: 24, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37701639

RESUMEN

Background: The International Thymic Malignancy Interest Group (ITMIG) proposed an internationally accepted division of the mediastinum into three compartments based on computed tomography (CT): anterior (prevascular), middle (visceral) and posterior (paravertebral) compartment. There is no generally accepted definition for the term "giant" when applied to middle mediastinal lesions. We defined the term "giant" and described our surgical experience in treating patients with giant lesions of the middle mediastinum. Methods: CT imaging of patients operated in our center from January 2016 to August 2021 for mediastinal lesions was reviewed. Lesions were categorized to one of the ITMIG-defined compartments. Lesion size at diagnosis was measured at its largest diameter on axial CT imaging. Giant middle mediastinal lesions were defined as lesions having a size ≥90th percentile of our middle mediastinal lesion cohort. Patients with giant middle mediastinal lesions were further analyzed. Results: Thirty-six patients (23%) had lesions located in the middle mediastinal compartment. Most common diagnoses were mediastinal cysts (n=10, 28%), metastatic lesions (n=6, 17%), lymphomas (n=5, 14%), and sarcomas (n=3, 8%). Ninetieth percentile lesion size was 73 mm. As per definition, four patients had giant middle mediastinal lesions. All these four lesions were of mesenchymal origin including oesophageal leiomyoma, synovial sarcoma, leiomyosarcoma and undifferentiated round cell sarcoma. Resection was performed through posterolateral thoracotomy or sternotomy, with or without cardiopulmonary bypass. Conclusions: The term "giant" could be defined as a mass larger or equal to 73 mm. This definition selected specifically lesions with mesenchymal origin and may therefore guide diagnostic algorithm and patient management.

17.
Medicina (Kaunas) ; 59(9)2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37763737

RESUMEN

Minimally invasive techniques have gained immense importance in cardiovascular surgery. While minimal access strategies for coronary and mitral valve surgery are already widely accepted and often used as standard approaches, the application of minimally invasive techniques is currently expanded towards more complex operations of the ascending aorta as well. In this new and developing field, various techniques have been established and reported ranging from upper hemisternotomy approaches, which allow even extensive operations of the ascending aorta to be performed through a minimally invasive access to sternal sparing thoracotomy strategies, which completely avoid sternal trauma during ascending aorta replacements. All of these techniques place high demands on patient selection, preoperative planning, and practical surgical implementation. Application of these strategies is currently limited to high-volume centers and highly experienced surgeons. This narrative review gives an overview of the currently available techniques with a special focus on the practical execution as well as the advantages and disadvantages of the currently available techniques. The first results demonstrate the practicability and safety of minimally invasive techniques for replacement of the ascending aorta in a well-selected patient population. With success and complication rates comparable to classic full sternotomy, the proof of concept for minimally invasive replacement of the ascending aorta is now achieved.

18.
Front Cardiovasc Med ; 10: 1229336, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37547249

RESUMEN

Introduction: Surgical treatment of patients with mitral valve regurgitation and advanced heart failure remains challenging. In order to avoid peri-operative low cardiac output, Impella 5.0 or 5.5 (5.x), implanted electively in a one-stage procedure, may serve as a peri-operative short-term mechanical circulatory support system (st-MCS) in patients undergoing mitral valve surgery. Methods: Between July 2017 and April 2022, 11 consecutive patients underwent high-risk mitral valve surgery for mitral regurgitation supported with an Impella 5.x system (Abiomed, Inc. Danvers, MA). All patients were discussed in the heart team and were either not eligible for transcatheter edge-to-edge repair (TEER) or surgery was considered favorable. In all cases, the indication for Impella 5.x implantation was made during the preoperative planning phase. Results: The mean age at the time of surgery was 61.6 ± 7.7 years. All patients presented with mitral regurgitation due to either ischemic (n = 5) or dilatative (n = 6) cardiomyopathy with a mean ejection fraction of 21 ± 4% (EuroScore II 6.1 ± 2.5). Uneventful mitral valve repair (n = 8) or replacement (n = 3) was performed via median sternotomy (n = 8) or right lateral mini thoracotomy (n = 3). In six patients, concomitant procedures, either tricuspid valve repair, aortic valve replacement or CABG were necessary. The mean duration on Impella support was 8 ± 5 days. All, but one patient, were successfully weaned from st-MCS, with no Impella-related complications. 30-day survival was 90.9%. Conclusion: Protected cardiac surgery with st-MCS using the Impella 5.x is safe and feasible when applied in high-risk mitral valve surgery without st-MCS-related complications, resulting in excellent outcomes. This strategy might offer an alternative and comprehensive approach for the treatment of patients with mitral regurgitation in advanced heart failure, deemed ineligible for TEER or with need of concomitant surgery.

19.
Int J Cardiol Heart Vasc ; 47: 101233, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37388420

RESUMEN

Introduction: Organ shortage, subsequent use of extended donor criteria organs and high-risk recipients needing redo-surgery are increasing the complexity of heart transplantation. Donor organ machine perfusion (MP) is an emerging technology allowing reduction of ischemia time as well as standardized evaluation of the organ. The aim of this study was to review the introduction of MP and analyze the results of heart transplantation after MP in our center. Methods: In a retrospective single-center study, data from a prospectively collected database were analysed. From July 2018 to August 2021, fourteen hearts were retrieved and perfused using the Organ Care System (OCS), 12 hearts were transplanted. Criteria to use the OCS were based on donor/recipient characteristics. Primary objective was 30-day survival, secondary objectives were major cardiac adverse events, graft function, rejection episodes as well as overall survival in the follow-up and assessment of MP technical reliability. Results: All patients survived the procedure and the postoperative 30-day interval. No MP related complications were noted. Graft ejection fraction beyond 14 days was ≥ 50% in all cases. Endomyocardial biopsy showed excellent results with no or mild rejection. Two donor hearts were rejected after OCS perfusion and evaluation. Conclusion: Ex vivo normothermic MP during organ procurement is a safe and promising technique to expand the donor pool. Reduction of cold ischemic time while providing additional donor heart assessment and reconditioning options increased the number of acceptable donor hearts. Additional clinical trials are necessary to develop guidelines regarding the application of MP.

20.
Int J Cardiol Heart Vasc ; 47: 101230, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37275625

RESUMEN

Background: Extra Corporeal Life Support (ECLS) is an evolving therapy in therapy-resistant cardiogenic shock (CS). Vascular cannulation in emergency situations can be accomplished through puncture of the femoral vessels by specialised teams. Since lower limb ischemia constitutes one of the major complications following cannulation, a distal perfusion cannula (DPC) has emerged as standard of care. We here aimed to analyse the impact of the DPC on limb perfusion and 6-month survival rate. Methods: In a retrospective study from January 2012 to December 2018, 98 patients with cardiogenic shock and peripheral (v-a) ECLS implantation with documented limb perfusion status were identified and analysed. Demographic data, laboratory parameters, cause of CS, comorbidities, limb perfusion complications and complication management were analysed. Results: 53 patients (54%) received ECLS therapy in referral centers by our mobile ECLS team, while in 45 patients (46%) the cannulation occured in our center. 71 patients (72%) received a DPC (group A) at the time of ECLS implantation, whereas 27 (28%) (group B) did not or received later (14 patients owing to limb ischemia). 44 patients (45%) developed limb ischemia as a complication of ECLS therapy (31% in group A and 81% in group B- p < 0.001). The 6-month survival rate was 28% in our study cohort (30% in group A and 22% in group B- p = 0.469). Conclusion: Lower limb ischemia remains a serious complication after peripheral ECLS cannulation in CS, especially when a DPC is absent. Standardised DPC implementation may reduce the rate of severe limb complications in peripheral ECLS.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...