Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Clin Oral Implants Res ; 34(8): 872-880, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37340736

RESUMEN

AIM: To compare mean bone level (mBL) changes around dental implants with one or two adjacent teeth after a function time of ≥10 years. MATERIALS AND METHODS: One hundred thirty three periodontally compromised patients (PCPs) with 551 implants enrolled in supportive periodontal care (SPC) were screened. Implants were categorized either into group TIT (tooth-implant-tooth) or into group TIG (tooth-implant-gap). MBL changes from delivery of restoration (i.e., baseline) to follow-up were calculated in millimeters and compared between implants and adjacent teeth. Survival rates and the need for surgical interventions during SPC were recorded. RESULTS: Eighty seven patients with 142 implants were re-evaluated after a mean observation time of 14.5 ± 3.5 years. The mBL at mesial implant sites in the TIT group increased -0.07 ± 0.92 mm and decreased in the TIG group 0.52 ± 1.34 mm, respectively (95% CI: 0.04/1.14, p = .037). At distal implant sites, the mBL in the TIT group increased -0.08 ± 0.84 mm and decreased 0.03 ± 0.87 in the TIG group, respectively (95% CI: -0.20/0.42, p = .48). The overall implant loss rate was 3.5% (n = 5; 2 TIT, 3 TIG), without a statistically significant difference between the two groups (95% CI: 0.18/7.07, p = .892). Tooth loss rates (TIT: 12.3%, TIG: 12.3%) were not statistically significantly different (OR = 1.00, p = .989). CONCLUSION: High tooth and implant survival rates were observed in PCPs. The presence of one or two adjacent teeth seemed to have no impact on marginal bone level changes.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales de Diente Único , Implantes Dentales , Diente , Humanos , Estudios Retrospectivos , Estudios de Seguimiento , Pérdida de Hueso Alveolar/diagnóstico por imagen , Prótesis Dental de Soporte Implantado
2.
Metabolites ; 10(6)2020 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-32486030

RESUMEN

After blood donation, the red blood cells (RBCs) for transfusion are generally isolated by centrifugation and then filtrated and supplemented with additive solution. The consecutive changes of the extracellular environment participate to the occurrence of storage lesions. In this study, the hypothesis is that restoring physiological levels of uric and ascorbic acids (major plasmatic antioxidants) might correct metabolism defects and protect RBCs from the very beginning of the storage period, to maintain their quality. Leukoreduced CPD-SAGM RBC concentrates were supplemented with 416 µM uric acid and 114 µM ascorbic acid and stored during six weeks at 4 °C. Different markers, i.e., haematological parameters, metabolism, sensitivity to oxidative stress, morphology and haemolysis were analyzed. Quantitative metabolomic analysis of targeted intracellular metabolites demonstrated a direct modification of several metabolite levels following antioxidant supplementation. No significant differences were observed for the other markers. In conclusion, the results obtained show that uric and ascorbic acids supplementation partially prevented the metabolic shift triggered by plasma depletion that occurs during the RBC concentrate preparation. The treatment directly and indirectly sustains the antioxidant protective system of the stored RBCs.

3.
J Sports Sci ; 36(2): 156-161, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28282753

RESUMEN

Although a low rolling resistance is advantageous in mountain bike cross-country racing, no studies have used the virtual elevation method to compare tyres from different manufacturers as used in international competitions so far. The aims of this study were to assess the reliability of this method, to compare the off-road rolling resistance between tyres and to calculate the influence on off-road speed. Nine 29-in. mountain bike cross-country tyres were tested on a course representing typical ground surface conditions 5 or 6 times. The coefficient of rolling resistance was estimated with the virtual elevation method by 3 investigators and corresponding off-road speeds were calculated. The virtual elevation method was highly reliable (typical error = 0.0006, 2.8%; limits of agreement <0.0005, r ≥ 0.98). The mean coefficient of rolling resistance was 0.0219 and differed from 0.0205 to 0.0237 (P < 0.001) between tyres. The calculated differences in off-road speed amounted to 2.9-3.2% (0% slope) and 2.3-2.4% (10% slope) between the slowest and the fastest tyre. The reliability of the method and the differences in rolling resistance between the tyres illustrate the value of testing tyres for important competitions on a representative ground surface using the virtual elevation method.


Asunto(s)
Ciclismo , Modelos Estadísticos , Equipo Deportivo , Ambiente , Diseño de Equipo , Humanos , Fenómenos Mecánicos , Reproducibilidad de los Resultados , Propiedades de Superficie
4.
Int J Sports Med ; 38(6): 456-461, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28482367

RESUMEN

The aim of this study was to compare the accuracy among a high number of current mobile cycling power meters used by elite and recreational cyclists against a first principle-based mathematical model of treadmill cycling. 54 power meters from 9 manufacturers used by 32 cyclists were calibrated. While the cyclist coasted downhill on a motorised treadmill, a back-pulling system was adjusted to counter the downhill force. The system was then loaded 3 times with 4 different masses while the cyclist pedalled to keep his position. The mean deviation (trueness) to the model and coefficient of variation (precision) were analysed. The mean deviations of the power meters were -0.9±3.2% (mean±SD) with 6 power meters deviating by more than±5%. The coefficients of variation of the power meters were 1.2±0.9% (mean±SD), with Stages varying more than SRM (p<0.001) and PowerTap (p<0.001). In conclusion, current power meters used by elite and recreational cyclists vary considerably in their trueness; precision is generally high but differs between manufacturers. Calibrating and adjusting the trueness of every power meter against a first principle-based reference is advised for accurate measurements.


Asunto(s)
Ciclismo/fisiología , Ergometría/instrumentación , Modelos Teóricos , Calibración , Prueba de Esfuerzo , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA