1.
Eur J Clin Invest ; 45(1): 13-7, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25402445

RESUMEN

BACKGROUND: This study describes the implications of the pharmacokinetics of low-dose chewable aspirin for acute coronary syndromes. Current guidelines recommend the administration of 162-325 mg aspirin chewing tablets for the treatment of acute myocardial infarction. Although aspirin is widely used and a cornerstone in myocardial infarction, there is no information available on the pharmacokinetics of low doses of chewable aspirin. MATERIALS AND METHODS: This prospective trial assessed the pharmacokinetics of acetylsalicylic acid and its metabolite salicylic acid after intake of 162 mg chewable low-dose aspirin in 35 healthy volunteers. Plasma drug and metabolite levels were analysed using high-performance liquid chromatography, and corresponding pharmacodynamics were determined by impedance aggregometry. RESULTS: Acetylsalicylic acid was rapidly absorbed with a mean Tmax of 27 ± 8 min. Tmax of salicylic acid was 69 ± 21 min. Mean Cmax was 1·8 ± 0·6 mg/L and 7·6 ± 1·4 for acetylsalicylic acid and salicylic acid, respectively. Arachidonic acid-induced aggregation showed maximum platelet inhibition 30 min after drug ingestion. CONCLUSIONS: The characterization of the plasma-time profile fills the gap between the lack of data on pharmacokinetics and the pharmacodynamics and the recommendation for using low-dose chewable aspirin for acute coronary syndromes. We describe for the first time that a 162-mg dose of chewable aspirin is rapidly absorbed and achieves plasma concentrations of the active metabolite salicylic acid required to maximally inhibit platelet aggregation. However, a 162-mg dose is truly a minimum, and doubling this dose might be better for patients with myocardial infarction.


Asunto(s)
Síndrome Coronario Agudo/tratamiento farmacológico , Aspirina/farmacocinética , Inhibidores de Agregación Plaquetaria/farmacocinética , Administración Oral , Adolescente , Adulto , Anciano , Aspirina/administración & dosificación , Aspirina/farmacología , Goma de Mascar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/farmacología , Estudios Prospectivos , Adulto Joven
2.
Biomed Chromatogr ; 27(6): 695-8, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23175424

RESUMEN

A selective, sensitive and rapid high-performance liquid chromatography method with post-column hydrolysis and fluorescence detection was developed for the simultaneous quantification of acetylsalicylic acid and its metabolite salicylic acid in human plasma. Following the addition of 2-hydroxy-3-methoxybenzoic acid as internal standard and simple protein precipitation with acetonitrile, the analytes were separated on a ProntoSIL 120 C18 ace-EPS column (150 × 2 mm, 3 µm) protected by a C8 guard column (5 µm). The mobile phase, 10 mm formic acid in water (pH 2.9) and acetonitrile (70:30, v/v), was used at a flow rate of 0.35 mL/min. After on-line post-column hydrolysis of acetylsalicylic acid (ASA) to salicylic acid (SA) by addition of alkaline solution, the analytes were measured at 290 nm (λex ) and 400 nm (λem ). The method was linear in the concentration ranges between 0.05 and 20 ng/µL for both ASA and SA with a lower limit of quantification of 25 pg/µL for SA and 50 pg/µL for ASA. The limit of detection was 15 pg/µL for SA and 32.5 pg/µL for ASA. The analysis of ASA and SA can be carried out within 8 min; therefore this method is suitable for measuring plasma concentrations of salicylates in clinical routine.


Asunto(s)
Aspirina/sangre , Cromatografía Líquida de Alta Presión/métodos , Ácido Salicílico/sangre , Estabilidad de Medicamentos , Humanos , Hidrólisis , Límite de Detección , Reproducibilidad de los Resultados , Espectrometría de Fluorescencia/métodos
3.
Ther Drug Monit ; 32(2): 145-51, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20216110

RESUMEN

The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT assay uses a whole blood specimen, a pretreatment step with organic reagents to precipitate proteins and extract the drug, followed by a 2-step automated immunoassay with magnetic microparticles coated with anti-CsA antibody and an acridinium-CsA tracer. Imprecision testing at the 7 evaluation sites gave a range of total % coefficient of variations of 7.5%-12.2% at 87.5 ng/mL, 6.6%-14.3% at 411 ng/mL, and 5.2%-10.7% at 916 ng/mL. The lower limit of quantification ranged from 12 to 20 ng/mL. Purified CsA metabolites AM1, AM1c, AM4N, AM9, and AM19 were tested in whole blood by the ARCHITECT assay and showed minimal cross-reactivity at all 7 sites. In particular, AM1 and AM9 cross-reactivity in the ARCHITECT assay, ranged from -2.5% to 0.2% and -0.8% to 2.2%, respectively, and was significantly lower than for the TDx assay, in which the values were 3.2% and 16.1%, respectively. Comparable testing of metabolites in the Dade Dimension Xpand assay at 2 evaluation sites showed cross-reactivity to AM4N (6.4% and 6.8%) and AM9 (2.6% and 3.6%) and testing on the Roche Integra 800 showed cross-reactivity to AM1c (2.4%), AM9 (10.7%), and AM19 (2.8%). Cyclosporine International Proficiency Testing Scheme samples, consisting of both pooled specimens from patients receiving CsA therapy as well as whole-blood specimens supplemented with CsA, were tested by the ARCHITECT assay at 6 sites and showed an average bias of -24 to -58 ng/mL versus LC/MSMS CsA and -2 to -37 ng/mL versus AxSYM CsA. Studies were performed with the ARCHITECT CsA assay on patient specimens with the following results: ARCHITECT CsA assay versus LC/MSMS, average bias of 31 ng/mL; ARCHITECT versus the Dade Dimension assay (4 sites), average biases of -7 to -228 ng/mL; ARCHITECT versus AxSYM and TDx, average biases of -4 and -53 ng/mL, respectively. Spearman correlation coefficients were >or=0.89. The ARCHITECT CsA assay has significantly reduced CsA metabolite interference relative to other immunoassays and is a convenient and sensitive semiautomated method to measure CsA in whole blood.


Asunto(s)
Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Ciclosporina/sangre , Especificidad de Anticuerpos , Evaluación Preclínica de Medicamentos/métodos , Evaluación Preclínica de Medicamentos/normas , Humanos , Inmunoensayo/métodos , Inmunoensayo/normas
4.
Clin Biochem ; 42(15): 1543-8, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19563794

RESUMEN

OBJECTIVE: This study evaluated a new chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the ARCHITECT analyzer. DESIGN AND METHODS: Patient and laboratory proficiency samples were tested at three European sites and one site in the United States. RESULTS: The CMIA total %CV's were all <8% and the Limit of Quantification (LOQ) was <1.52 ng/mL across the four sites. It cross-reacts to sirolimus metabolites F4 and F5 and showed no hematocrit interference over a range of 25% to 55%. Patient specimen correlations to three LC/MS/MS methods gave R>or=0.91 at three sites and mean biases of 14%, 25% and 39%. CMIA patient specimen correlations to the Abbott IMx gave R>or=0.94 at 2 sites and mean biases of 5.4% and 6.9%. CONCLUSIONS: CMIA is a precise and sensitive immunoassay method without hematocrit interference. It correlates well to both LC/MS/MS and immunoassay results, but shows an expected positive bias to LC/MS/MS.


Asunto(s)
Inmunoensayo/métodos , Inmunosupresores/sangre , Mediciones Luminiscentes/métodos , Magnetismo , Sirolimus/sangre , Especificidad de Anticuerpos , Cromatografía Liquida/métodos , Humanos , Inmunoensayo/instrumentación , Mediciones Luminiscentes/instrumentación , Tamaño de la Partícula , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/métodos
5.
Ther Drug Monit ; 31(2): 198-204, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19258928

RESUMEN

The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Tacrolimus immunoassay. Proficiency panels and specimens from a population of organ transplant recipients were analyzed in 6 clinical laboratories in Europe and the United States, and the results were compared with other methods. The ARCHITECT assay requires a whole blood specimen pretreatment step with methanol/zinc sulfate to precipitate protein and extract the drug, followed by a 30-minute immunoassay using anti-tacrolimus antibody-coated paramagnetic microparticles and an acridinium-tacrolimus tracer. The assay was free from hematocrit interference in the range 25%-55% and from interference by extremes of cholesterol, triglycerides, bilirubin, total protein, and uric acid. The total percent of coefficient of variations of the assay were 4.9%-7.6% at 3 ng/mL, 2.9%-4.6% at 8.6 ng/mL, and 3.1%-8.2% at 15.5 ng/mL. Limit of detection was < or =0.5 ng/mL and limit of quantification (LOQ) ranged from 0.69 to 1.07 ng/mL across the 6 sites (based on the upper 95% confidence interval concentrations). The 2007 European Consensus Conference on Tacrolimus Optimization recommended the use of assay methods with an LOQ around 1 ng/mL, based upon the need to measure trough tacrolimus blood concentrations precisely down to 3 ng/mL during low-dose tacrolimus regimens. Tacrolimus International Proficiency Testing Scheme samples were measured by the ARCHITECT immunoassay at 5 sites and showed an average bias of -0.28 to +0.85 ng/mL versus IMx Tacrolimus II immunoassay historical values and -0.21 to +0.68 ng/mL versus liquid chromatography/tandem mass spectrometry (LC-MSMS) Tacrolimus historical values. Method comparison studies were performed with the ARCHITECT Tacrolimus immunoassay on patient specimens with the following results: ARCHITECT Tacrolimus assay versus the Abbott IMx Tacrolimus II immunoassay (4 sites) yielded average biases between -0.94 and +0.26 ng/mL; ARCHITECT assay versus the Dade Dimension Tacrolimus immunoassay (2 sites) yielded average biases of -0.46 and +0.11 ng/mL; and ARCHITECT assay versus LC-MSMS methods at 2 sites yielded average biases of +0.51 and +1.63 ng/mL. Spearman correlation coefficients were >/=0.90 on all method comparisons. The ARCHITECT Tacrolimus assay is a semiautomated, robust, and highly sensitive immunoassay, representing an alternative approach for laboratories not equipped with LC-MSMS, and meets the 1 ng/mL recommendation of LOQ by the European Consensus Conference on Tacrolimus Optimization.


Asunto(s)
Inmunosupresores/sangre , Tacrolimus/sangre , Cromatografía Liquida , Humanos , Inmunoensayo , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem
6.
J Am Coll Cardiol ; 39(2): 251-6, 2002 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-11788216

RESUMEN

OBJECTIVES: The aim of this study was to determine whether nicotine, a constituent of cigarette smoke, contributes to acute endothelial dysfunction after smoking one cigarette. BACKGROUND: Animal studies suggest that nicotine might cause an impairment of endothelium-dependent vasodilation via an increase in oxidative stress. METHODS: Sixteen healthy smokers were entered into a randomized, observer-blinded crossover study comparing the effects of nicotine nasal spray (1-mg nicotine) and cigarette smoke (1-mg nicotine, 12 mg tar) on vascular reactivity in the brachial artery. Using high-resolution ultrasound, flow-mediated dilation (FMD) and endothelium-independent, nitroglycerin-induced dilation were assessed at baseline and 20 min after the administration of nicotine (spray or cigarette). RESULTS: In response to similar increases in nicotine serum levels, FMD values declined from 10.2 +/- 4.4% to 6.7 +/- 4.0% after the spray (mean difference: -3.6 +/- 2.0%, 95% confidence interval: -4.6; -2.5, p < 0.0001) and from 9.4 +/- 3.8% to 4.3 +/- 2.8% after the cigarette (-5.1 +/- 2.6%, -6.5; -3.7, p < 0.0001). Nitroglycerin-induced dilation remained similar within both periods. Performing a period effect analysis of variance, a significant influence on FMD was found for the mode of administration (p = 0.017) and the baseline value (p = 0.021). The effect on FMD was more pronounced after the cigarette than after the spray (estimated average effect difference: 1.9% FMD). Oxidation parameters did not increase significantly after nicotine spray or tobacco exposure. CONCLUSIONS: These results demonstrate that nicotine alone causes acute endothelial dysfunction, although to a lesser extent than smoking a cigarette of the same nicotine yield. However, the precise mechanisms by which nicotine leads to this altered vascular reactivity remain unclear.


Asunto(s)
Endotelio Vascular/efectos de los fármacos , Nicotina/farmacología , Fumar/fisiopatología , Adulto , Cromatografía Líquida de Alta Presión , Estudios Cruzados , Femenino , Humanos , Masculino , Estrés Oxidativo/fisiología , Método Simple Ciego , Sustancias Reactivas al Ácido Tiobarbitúrico , Vasodilatación/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...