Radiol Cardiothorac Imaging ; 6(2): e230172, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38573128

RESUMEN

Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.


Asunto(s)
Fibrilación Atrial , Diafragma , Anciano , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico , Medios de Contraste , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Femenino
2.
Artículo en Inglés | MEDLINE | ID: mdl-38676848

RESUMEN

Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using .15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52-0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR.

3.
J Cardiovasc Electrophysiol ; 35(2): 258-266, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38065834

RESUMEN

BACKGROUND: Incomplete atrial lesions resulting in pulmonary vein-left atrium reconnection after pulmonary vein antrum isolation (PVAI), are related to atrial fibrillation (AF) recurrence. Unfortunately, during the PVAI procedure, fluoroscopy and electroanatomic mapping cannot accurately determine the location and size of the ablation lesions in the atrial wall and this can result in incomplete PVAI lesions (PVAI-L) after radiofrequency catheter ablation (RFCA). AIM: We seek to evaluate whether cardiac magnetic resonance (CMR), immediately after RFCA of AF, can identify PVAI-L by characterizing the left atrial tissue. METHODS: Ten patients (63.1 ± 5.7 years old, 80% male) receiving a RFCA for paroxysmal AF underwent a CMR before (<1 week) and after (<1 h) the PVAI. Two-dimensional dark-blood T2-weighted short tau inversion recovery (DB-STIR), Three-dimensional inversion-recovery prepared long inversion time (3D-TWILITE) and three-dimensional late gadolinium enhancement (3D-LGE) images were performed to visualize PVAI-L. RESULTS: The PVAI-L was visible in 10 patients (100%) using 3D-TWILITE and 3D-LGE. Conversely, On DB-STIR, the ablation core of the PAVI-L could not be identified because of a diffuse high signal of the atrial wall post-PVAI. Microvascular obstruction was identified in 7 (70%) patients using 3D-LGE. CONCLUSION: CMR can visualize PVAI-L immediately after the RFCA of AF even without the use of contrast agents. Future studies are needed to understand if the use of CMR for PVAI-L detection after RFCA can improve the results of ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Medios de Contraste , Resultado del Tratamiento , Gadolinio , Espectroscopía de Resonancia Magnética , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía
4.
Radiol Med ; 129(2): 268-279, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38017228

RESUMEN

OBJECTIVES: To compare a novel, non-contrast, flow-independent, 3D isotropic magnetic resonance angiography (MRA) sequence that combines respiration compensation, electrocardiogram (ECG)-triggering, undersampling, and Dixon water-fat separation with an ECG-triggered aortic high-pitch computed tomography angiography (CTA) of the aorta. MATERIALS AND METHODS: Twenty-five patients with recent CTA were scheduled for non-contrast MRA on a 3 T MRI. Aortic diameters and cross-sectional areas were measured on MRA and CTA using semiautomatic measurement tools at 11 aortic levels. Image quality was assessed independently by two radiologists on predefined aortic levels, including myocardium, proximal aortic branches, pulmonary veins and arteries, and the inferior (IVC) and superior vena cava (SVC). Image quality was assessed on a 5-point Likert scale. RESULTS: All datasets showed diagnostic image quality. Visual grading was similar for MRA and CTA regarding overall image quality (0.71), systemic arterial image quality (p = 0.07-0.91) and pulmonary artery image quality (p = 0.05). Both readers favored MRA for SVC and IVC, while CTA was preferred for pulmonary veins (all p < 0.05). No significant difference was observed in aortic diameters or cross-sectional areas between native MRA and contrast-enhanced CTA (p = 0.08-0.94). CONCLUSION: The proposed non-contrast MRA enables robust imaging of the aorta, its proximal branches and the pulmonary arteries and great veins with image quality and aortic diameters and cross-sectional areas comparable to that of CTA. Moreover, this technique represents a suitable free-breathing alternative, without the use of contrast agents or ionizing radiation. Therefore, it is especially suitable for patients requiring repetitive imaging.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Humanos , Angiografía por Resonancia Magnética/métodos , Vena Cava Superior/diagnóstico por imagen , Arteria Pulmonar
5.
J Thorac Imaging ; 39(2): 127-135, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982533

RESUMEN

BACKGROUND: Cardiac magnetic resonance imaging protocols have been adapted to fit the needs for faster, more efficient acquisitions, resulting in the development of highly accelerated, compressed sensing-based (CS) sequences. The aim of this study was to evaluate intersoftware and interacquisition differences for postprocessing software applied to both CS and conventional cine sequences. MATERIALS AND METHODS: A total of 106 individuals (66 healthy volunteers, 40 patients with dilated cardiomyopathy, 51% female, 38±17 y) underwent cardiac magnetic resonance at 3T with retrospectively gated conventional cine and CS sequences. Postprocessing was performed using 2 commercially available software solutions and 1 research prototype from 3 different developers. The agreement of clinical and feature-tracking strain parameters between software solutions and acquisition types was assessed by Bland-Altmann analyses and intraclass correlation coefficients. Differences between softwares and acquisitions were assessed using Kruskal-Wallis analysis of variances. In addition, receiver operating characteristic curve-derived cutoffs were used to evaluate whether sequence-specific cutoffs influence disease classification. RESULTS: There were significant intersoftware ( P <0.002 for all except LV end-diastolic volume per body surface area) and interacquisition differences ( P <0.02 for all except end-diastolic volume per body surface area from Neosoft, left ventricular mass per body surface area from cvi42 and TrufiStrain and global circumferential strain from Neosoft). However, the intraclass correlation coefficients between acquisitions were strong-to-excellent for all parameters (all ≥0.81). In comparing individual softwares to a pooled mean, Bland-Altmann analyses revealed smaller magnitudes of bias for cine acquisition than for CS acquisition. In addition, the application of conventional cutoffs to CS measurements did not result in the false reclassification of patients. CONCLUSION: Significantly lower magnitudes of strain and volumetric parameters were observed in retrospectively gated CS acquisitions, despite strong-to-excellent agreement amongst software solutions and acquisition types. It remains important to be aware of the acquisition type in the context of follow-up examinations, where different cutoffs might lead to misclassifications.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Humanos , Femenino , Masculino , Estudios Retrospectivos , Imagen por Resonancia Cinemagnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Ventrículos Cardíacos , Función Ventricular Izquierda
6.
J Cardiovasc Magn Reson ; 25(1): 52, 2023 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-37779192

RESUMEN

BACKGROUND: Coronary magnetic resonance angiography (coronary MRA) is increasingly being considered as a clinically viable method to investigate coronary artery disease (CAD). Accurate determination of the trigger delay to place the acquisition window within the quiescent part of the cardiac cycle is critical for coronary MRA in order to reduce cardiac motion. This is currently reliant on operator-led decision making, which can negatively affect consistency of scan acquisition. Recently developed deep learning (DL) derived software may overcome these issues by automation of cardiac rest period detection. METHODS: Thirty individuals (female, n = 10) were investigated using a 0.9 mm isotropic image-navigator (iNAV)-based motion-corrected coronary MRA sequence. Each individual was scanned three times utilising different strategies for determination of the optimal trigger delay: (1) the DL software, (2) an experienced operator decision, and (3) a previously utilised formula for determining the trigger delay. Methodologies were compared using custom-made analysis software to assess visible coronary vessel length and coronary vessel sharpness for the entire vessel length and the first 4 cm of each vessel. RESULTS: There was no difference in image quality between any of the methodologies for determination of the optimal trigger delay, as assessed by visible coronary vessel length, coronary vessel sharpness for each entire vessel and vessel sharpness for the first 4 cm of the left mainstem, left anterior descending or right coronary arteries. However, vessel length of the left circumflex was slightly greater using the formula method. The time taken to calculate the trigger delay was significantly lower for the DL-method as compared to the operator-led approach (106 ± 38.0 s vs 168 ± 39.2 s, p < 0.01, 95% CI of difference 25.5-98.1 s). CONCLUSIONS: Deep learning-derived automated software can effectively and efficiently determine the optimal trigger delay for acquisition of coronary MRA and thus may simplify workflow and improve reproducibility.


Asunto(s)
Corazón , Angiografía por Resonancia Magnética , Humanos , Femenino , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Angiografía Coronaria/métodos , Imagenología Tridimensional
7.
Clin Neuroradiol ; 33(4): 1115-1122, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37401949

RESUMEN

PURPOSE: The 3D time-of-flight (TOF) magnetic resonance angiography (MRA) at 3T shows high sensitivity for intracranial aneurysms but is inferior to three-dimensional digital subtraction angiography (3D-DSA) regarding aneurysm characteristics. We applied an ultra-high-resolution (UHR) TOF-MRA using compressed sensing reconstruction to investigate the diagnostic performance in preinterventional evaluation of intracranial aneurysms compared to conventional TOF-MRA and 3D-DSA. METHODS: In this study 17 patients with unruptured intracranial aneurysms were included. Aneurysm dimensions, configuration, image quality and sizing of endovascular devices were compared between conventional TOF-MRA at 3T and UHR-TOF with 3D-DSA as gold standard. Quantitatively, contrast-to-noise ratios (CNR) were compared between TOF-MRAs. RESULTS: On 3D-DSA, 25 aneurysms in 17 patients were detected. On conventional TOF, 23 aneurysms were detected (sensitivity: 92.6%). On UHR-TOF, 25 aneurysms were detected (sensitivity: 100%). Image quality was not significantly different between TOF and UHR-TOF (p = 0.17). Aneurysm dimension measurements were significantly different between conventional TOF (3.89 mm) and 3D-DSA (4.2 mm, p = 0.08) but not between UHR-TOF (4.12 mm) and 3D-DSA (p = 0.19). Irregularities and small vessels at the aneurysm neck were more frequently correctly depicted on UHR-TOF compared to conventional TOF. Comparison of the planned framing coil diameter and flow-diverter (FD) diameter revealed neither a statistically significant difference between TOF and 3D-DSA (coil p = 0.19, FD p = 0.45) nor between UHR-TOF and 3D-DSA (coil: p = 0.53, FD 0.33). The CNR was significantly higher in conventional TOF (p = 0.009). CONCLUSION: In this pilot study, ultra-high-resolution TOF-MRA visualized all aneurysms and accurately depicted aneurysm irregularities and vessels at the base of the aneurysm comparably to DSA, outperforming conventional TOF. UHR-TOF with compressed sensing reconstruction seems to represent a non-invasive alternative to pre-interventional DSA for intracranial aneurysms.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/patología , Estudios de Seguimiento , Proyectos Piloto , Angiografía por Resonancia Magnética/métodos , Angiografía de Substracción Digital/métodos , Sensibilidad y Especificidad
8.
Diagn Interv Imaging ; 2023 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-37328394

RESUMEN

PURPOSE: The purpose of this study was to compare a new free-breathing compressed sensing cine (FB-CS) cardiac magnetic resonance imaging (CMR) to the standard reference multi-breath-hold segmented cine (BH-SEG) CMR in an unselected population. MATERIALS AND METHODS: From January to April 2021, 52 consecutive adult patients who underwent both conventional BH-SEG CMR and new FB-CS CMR with fully automated respiratory motion correction were retrospectively enrolled. There were 29 men and 23 women with a mean age of 57.7 ± 18.9 (standard deviation [SD]) years (age range: 19.0-90.0 years) and a mean cardiac rate of 74.6 ± 17.9 (SD) bpm. For each patient, short-axis stacks were acquired with similar parameters providing a spatial resolution of 1.8 × 1.8 × 8.0 mm3 and 25 cardiac frames. Acquisition and reconstruction times, image quality (Likert scale from 1 to 4), left and right ventricular volumes and ejection fractions, left ventricular mass, and global circumferential strain were assessed for each sequence. RESULTS: FB-CS CMR acquisition time was significantly shorter (123.8 ± 28.4 [SD] s vs. 267.2 ± 39.3 [SD] s for BH-SEG CMR; P < 0.0001) at the penalty of a longer reconstruction time (271.4 ± 68.7 [SD] s vs. 9.9 ± 2.1 [SD] s for BH-SEG CMR; P < 0.0001). In patients without arrhythmia or dyspnea, FB-CS CMR provided subjective image quality that was not different from that of BH-SEG CMR (P = 0.13). FB-CS CMR improved image quality in patients with arrhythmia (n = 18; P = 0.002) or dyspnea (n = 7; P = 0.02), and the edge sharpness was improved at end-systole and end-diastole (P = 0.0001). No differences were observed between the two techniques in ventricular volumes and ejection fractions, left ventricular mass or global circumferential strain in patients in sinus rhythm or with cardiac arrhythmia. CONCLUSION: This new FB-CS CMR addresses respiratory motion and arrhythmia-related artifacts without compromising the reliability of ventricular functional assessment.

9.
Int J Cardiovasc Imaging ; 39(1): 135-144, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36598693

RESUMEN

The aim of this study was to investigate the diagnostic accuracy and reader confidence for late-gadolinium enhancement (LGE) detection of a novel free-breathing, image-based navigated 3D whole-heart LGE sequence with fat-water separation, compared to a free-breathing motion-corrected 2D LGE sequence in patients with ischemic and non-ischemic cardiomyopathy. Cardiac MRI patients including the respective sequences were retrospectively included. Two independent, blinded readers rated image quality, depiction of segmental LGE and documented acquisition time, SNR, CNR and amount of LGE. Results were compared using the Friedman or the Kruskal-Wallis test. For LGE rating, a jackknife free-response receiver operating characteristic analysis was performed with a figure of merit (FOM) calculation. Forty-two patients were included, thirty-two were examined with a 1.5 T-scanner and ten patients with a 3 T-scanner. The mean acquisition time of the 2D sequence was significantly shorter compared to the 3D sequence (07:12 min vs. 09:24 min; p < 0.001). The 3D scan time was significantly shorter when performed at 3 T compared to 1.5 T (07:47 min vs. 09:50 min; p < 0.001). There were no differences regarding SNR, CNR or amount of LGE. 3D imaging had a significantly higher FOM (0.89 vs. 0.78; p < 0.001). Overall image quality ratings were similar, but 3D sequence ratings were higher for fine anatomical structures. Free-breathing motion-corrected 3D LGE with high isotropic resolution results in enhanced LGE-detection with higher confidence and better delineation of fine structures. The acquisition time for 3D imaging was longer, but may be reduced by performing on a 3 T-scanner.


Asunto(s)
Medios de Contraste , Gadolinio , Humanos , Cicatriz , Agua , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Aumento de la Imagen/métodos
10.
PLoS One ; 17(12): e0278558, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36472982

RESUMEN

OBJECTIVE: This study contributes to the quantitatively large, yet narrow in scope research on body image in gay men by assessing whether gay and heterosexual men systematically differ on various dimensions of body image disturbance and associated pathology, i.e., eating disorder and body dysmorphic disorder symptoms. Moreover, we examined the influence of general everyday discrimination experiences and involvement with the gay community on body image. METHOD: N = 216 men (n = 112 gay men, n = 104 heterosexual men) participated in an online survey measuring the discrepancy between self-rated current and ideal body fat/ muscularity; drive for leanness, muscularity, and thinness; body satisfaction; body-related avoidance and checking; appearance fixing; overall body image disturbance; eating disorder and body dysmorphic disorder pathology; general everyday discrimination experiences; and involvement with the gay community. RESULTS: Gay men showed a greater discrepancy between self-rated current and ideal body fat; higher drive for thinness, body-related avoidance, appearance fixing, overall body image disturbance, eating disorder and body dysmorphic disorder pathology; and lower body appreciation than heterosexual men (all p ≤ .05). Contrary to expectation, everyday discrimination experiences were more strongly associated with body image disturbance and eating disorder/ body dysmorphic disorder pathology in heterosexual men than in gay men (all p ≤ .05). Gay community involvement was not associated with any body image disturbance-, ED-, or BDD aspect in gay men (all p ≥ .20). DISCUSSION: The results suggest greater body image disturbance in gay men than in heterosexual men regarding cognitions, emotions, behaviors, and perception as well as higher eating disorder and body dysmorphic disorder pathology. The results also suggest the dilemma of a thin, yet muscular body ideal in gay men. Surprisingly, discrimination experiences and involvement with the gay community did not explain differences in body image disturbance. Gay men may have become resilient to discrimination over time, and body ideals might differ across gay sub-communities.


Asunto(s)
Trastorno Dismórfico Corporal , Trastornos de Alimentación y de la Ingestión de Alimentos , Humanos , Imagen Corporal , Cognición
11.
Acta Radiol Open ; 11(10): 20584601221137772, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36325309

RESUMEN

Background: A cardiac resting phase is used when performing free-breathing cardiac magnetic resonance examinations. Purpose: The purpose of this study was to test a cardiac resting phase detection system based on neural networks in clinical practice. Material and Methods: Four chamber-view cine images were obtained from 32 patients and analyzed. The rest duration, start point, and end point were compared between that determined by the experts and general operators, and a similar comparison was done between that determined by the experts and neural networks: the normalized root-mean-square error (RMSE) was also calculated. Results: Unlike manual detection, the neural network was able to determine the resting phase almost simultaneously as the image was obtained. The rest duration and start point were not significantly different between the neural network and expert (p = .30, .90, respectively), whereas the end point was significantly different between the two groups (p < .05). The start point was not significantly different between the general operator and expert (p = .09), whereas the rest duration and end point were significantly different between the two groups (p < .05). The normalized RMSEs of the rest duration, start point, and end point of the neural network were 0.88, 0.64, and 0.33 ms, respectively, which were lower than those of the general operator (normalized RMSE values were 0.98, 0.68, and 0.51 ms, respectively). Conclusions: The neural network can determine the resting phase instantly with better accuracy than the manual detection of general operators.

12.
Scand Cardiovasc J ; 56(1): 266-275, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35836407

RESUMEN

Objectives. To evaluate if cine sequences accelerated by compressed sensing (CS) are feasible in clinical routine and yield equivalent cardiac morphology in less time. Design. We evaluated 155 consecutive patients with various cardiac diseases scanned during our clinical routine. LV and RV short axis (SAX) cine images were acquired by conventional and prototype 2-shot CS sequences on a 1.5 T CMR. The 2-shot prototype captures the entire heart over a period of 3 beats making the acquisition potentially even faster. Both scans were performed with identical slice parameters and positions. We compared LV and RV morphology with Bland-Altmann plots and weighted the results in relation to pre-defined tolerance intervals. Subjective and objective image quality was evaluated using a 4-point score and adapted standardized criteria. Scan times were evaluated for each sequence. Results. In total, no acquisitions were lost due to non-diagnostic image quality in the subjective image score. Objective image quality analysis showed no statistically significant differences. The scan time of the CS cines was significantly shorter (p < .001) with mean scan times of 178 ± 36 s compared to 313 ± 65 s for the conventional cine. All cardiac function parameters showed excellent correlation (r 0.978-0.996). Both sequences were considered equivalent for the assessment of LV and RV morphology. Conclusions. The 2-shot CS SAX cines can be used in clinical routine to acquire cardiac morphology in less time compared to the conventional method, with no total loss of acquisitions due to nondiagnostic quality. TRIAL REGISTRATION: ISRCTN12344380. Registered 20 November 2020, retrospectively registered.


Asunto(s)
Imagen por Resonancia Cinemagnética , Función Ventricular Derecha , Contencion de la Respiración , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Función Ventricular Izquierda
13.
Tomography ; 8(3): 1608-1617, 2022 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-35736881

RESUMEN

The aim of our study was to compare compressed sensing (CS) time-of-flight (TOF) magnetic resonance angiography (MRA) with parallel imaging (PI) TOF MRA in the evaluation of patients with intracranial aneurysms treated with coil embolization or stent-assisted coiling. We enrolled 22 patients who underwent follow-up imaging after intracranial aneurysm coil embolization. All patients underwent both PI TOF and CS TOF MRA during the same examination. Image evaluation aimed to compare the performance of CS to PI TOF MRA in determining the degree of aneurysm occlusion, as well as the depiction of parent vessel and vessels adjacent to the aneurysm dome. The reference standard for the evaluation of aneurysm occlusion was PI TOF MRA. The inter-modality agreement between CS and PI TOF MRA in the evaluation of aneurysm occlusion was almost perfect (κ = 0.98, p < 0.001) and the overall inter-rater agreement was substantial (κ = 0.70, p < 0.001). The visualization of aneurysm parent vessel in CS TOF images compared with PI TOF images was evaluated to be better in 11.4%, equal in 86.4%, and worse in 2.3%. CS TOF MRA, with almost 70% scan time reduction with respect to PI TOF MRA, yields comparable results for assessing the occlusion status of coiled intracranial aneurysms. Short scan times increase patient comfort, reduce the risk of motion artifacts, and increase patient throughput, with a resulting reduction in costs. CS TOF MRA may therefore be a potential replacement for PI TOF MRA as a first-line follow-up examination in patients with intracranial aneurysms treated with coil embolization.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Angiografía de Substracción Digital/métodos , Embolización Terapéutica/métodos , Estudios de Seguimiento , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Angiografía por Resonancia Magnética/métodos
14.
BMC Med Imaging ; 22(1): 64, 2022 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-35387607

RESUMEN

BACKGROUND: To evaluate the utility of high-resolution compressed sensing time-of-fight MR angiography (CS TOF-MRA) for assessing patients with moyamoya disease (MMD) after surgical revascularization, by comparison with computer tomography angiography (CTA). METHODS: Twenty patients with MMD after surgical revascularizations who underwent CS TOF-MRA and CTA were collected. The scan time of CS TOF-MRA was 5 min and 4 s, with a reconstructed resolution of 0.4 × 0.4 × 0.4 mm3. Visualization of superficial temporal artery and middle cerebral artery (STA-MCA) bypass, neovascularization into the brain pial surface and Moyamoya vessels (MMVs) were independently ranked by two neuroradiologists on CS TOF-MRA and CTA, respectively. The patency of anastomosis was assessed as patent or occluded, using digital subtraction angiography and expert's consensus as ground truth. Interobserver agreement was calculated using the weighted kappa statistic. Wilcoxon signed-rank or Chi-square test was performed to investigate diagnostic difference between CS TOF-MRA and CTA. RESULTS: Twenty-two hemispheres from 20 patients were analyzed. The inter-reader agreement for evaluating STA-MCA bypass, neovascularization and anastomosis patency was good to excellent (κCS TOF-MRA, 0.738-1.000; κCTA, 0.743-0.909). The STA-MCA bypass and MMVs were better visualized on CS TOF-MRA than CTA (both P < 0.05). CS TOF-MRA had a higher sensitivity than CTA (94.7% vs. 73.7%) for visualizing anastomoses. Neovascularization was better observed in 13 (59.1%) sides on CS TOF-MRA, in comparison to 7 (31.8%) sides on CTA images (P = 0.005). CONCLUSION: High-resolution CS TOF-MRA outperforms CTA for visualization of STA-MCA bypass, neovascularization and MMVs within a clinically reasonable time in MMD patients after revascularization.


Asunto(s)
Enfermedad de Moyamoya , Angiografía de Substracción Digital/métodos , Angiografía por Tomografía Computarizada , Humanos , Angiografía por Resonancia Magnética/métodos , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/cirugía
15.
Eur Radiol ; 32(8): 5392-5401, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35298680

RESUMEN

OBJECTIVES: To assess the feasibility of low-dose contrast-enhanced four-dimensional (4D) time-resolved angiography with stochastic trajectories (TWIST) with iterative reconstruction (hereafter IT-TWIST-MRA) covering the whole brain and to compare IT-TWIST-MRA and TWIST-MRA with reference to digital subtraction angiography (DSA) in the evaluation of arteriovenous shunts (AVS). METHODS: Institutional Review Board approval was obtained for this observational study, and the requirement for written informed consent was waived. Twenty-nine patients with known AVS underwent TWIST-MRA on a 3-T MRI scanner, using low-dose injection (0.02 mmol/kg) of gadolinium-based contrast agent (GBCA) with each of Fourier and iterative reconstruction between September 2016 and October 2019. Visual evaluation of image quality was conducted for delineation of (a) the normal cerebral arteries and veins and (b) AVS feeder, shunt, and drainer vessels. Region-of-interest evaluation was conducted to evaluate bolus sharpness and baseline signal fluctuation in the signal intensity of the cerebral vessels. We compared the detection of AVS between TWIST-MRA and IT-TWIST-MRA. The paired-samples Wilcoxon test was used to test the differences between TWIST-MRA and IT-TWIST-MRA. RESULTS: Visualization scores for normal vasculature and AVS angioarchitecture were significantly better for images produced using IT-TWIST-MRA than those using TWIST-MRA. Peak signal and the enhancement slope of the time-intensity curve were significantly higher for IT-TWIST-MRA than for TWIST-MRA, except for the superior sagittal sinus (SSS). Baseline intensity fluctuation was significantly lower for IT-TWIST-MRA than for TWIST, except for SSS. CONCLUSIONS: IT-TWIST-MRA yields clinically feasible 4D MR-DSA images and delineates AVS even with low-dose GBCA. KEY POINTS: • Iterative reconstruction significantly improves the image quality of TWIST-MRA covering the whole brain. • The short temporal footprint and denoising effect of iterative reconstruction enhances the quality of 4D-MRA. • IT-TWIST-MRA yields clinically feasible images of AVS with low-dose GBCA.


Asunto(s)
Aumento de la Imagen , Angiografía por Resonancia Magnética , Angiografía de Substracción Digital , Encéfalo , Medios de Contraste/farmacología , Humanos , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X
16.
Int J Cardiovasc Imaging ; 38(8): 1837-1850, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35243574

RESUMEN

The goal of this study was to evaluate a three-dimensional compressed sensing (3D-CS) LGE prototype sequence for the detection and quantification of myocardial fibrosis in patients with chronic myocardial infarction (CMI) and myocarditis (MYC) compared with a 2D-LGE standard. Patients with left-ventricular LGE due to CMI (n = 33) or MYC (n = 20) were prospectively recruited. 2D-LGE and 3D-CS images were acquired in random order at 1.5 Tesla. 3D-CS short axis (SAX) images were reconstructed corresponding to 2D SAX images. LGE was quantitatively assessed on patient and segment level using semi-automated threshold methods. Image quality (4-point scoring system), Contrast-ratio (CR) and acquisition times were compared. There was no significant difference between 2D and 3D sequences regarding global LGE (%) (CMI [2D-LGE: 11.4 ± 7.5; 3D-LGE: 11.5 ± 8.5; p = 0.99]; MYC [2D-LGE: 27.0 ± 15.7; 3D-LGE: 26.2 ± 13.1; p = 0.70]) and segmental LGE-extent (p = 0.63). 3D-CS identified papillary infarction in 5 cases which was not present in 2D images. 2D-LGE acquisition time was shorter (2D: median: 06:59 min [IQR: 05:51-08:18]; 3D: 14:48 min [12:45-16:57]). 3D-CS obtained better quality scores (2D: 2.06 ± 0.56 vs. 3D: 2.29 ± 0.61). CR did not differ (p = 0.63) between basal and apical regions in 3D-CS images but decreased significantly in 2D apical images (CR basal: 2D: 0.77 ± 0.11, 3D: 0.59 ± 0.10; CR apical: 2D: 0.64 ± 0.17, 3D: 0.53 ± 0.11). 3D-LGE shows high congruency with standard LGE and allows better identification of small lesions. However, the current 3D-CS LGE sequence did not provide PSIR reconstruction and acquisition time was longer.


Asunto(s)
Infarto del Miocardio , Miocarditis , Humanos , Cicatriz/diagnóstico por imagen , Cicatriz/etiología , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Valor Predictivo de las Pruebas , Infarto del Miocardio/diagnóstico por imagen , Imagenología Tridimensional/métodos
17.
Eur Radiol ; 32(7): 4340-4351, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35184220

RESUMEN

OBJECTIVES: To investigate the efficacy of an in-line non-rigid motion-compensated reconstruction (NRC) in an image-navigated high-resolution three-dimensional late gadolinium enhancement (LGE) sequence with Dixon water-fat separation, in a clinical setting. METHODS: Forty-seven consecutive patients were enrolled prospectively and examined with 1.5 T MRI. NRC reconstructions were compared to translational motion-compensated reconstructions (TC) of the same datasets in overall and different sub-category image quality scores, diagnostic confidence, contrast ratios, LGE pattern, and semiautomatic LGE quantification. RESULTS: NRC outperformed TC in all image quality scores (p < 0.001 to 0.016; e.g., overall image quality 5/5 points vs. 4/5). Overall image quality was downgraded in only 23% of NRC datasets vs. 53% of TC datasets due to residual respiratory motion. In both reconstructions, LGE was rated as ischemic in 11 patients and non-ischemic in 10 patients, while it was absent in 26 patients. NRC delivered significantly higher LGE-to-myocardium and blood-to-myocardium contrast ratios (median 6.33 vs. 5.96, p < 0.001 and 4.88 vs. 4.66, p < 0.001, respectively). Automatically detected LGE mass was significantly lower in the NRC reconstruction (p < 0.001). Diagnostic confidence was identical in all cases, with high confidence in 89% and probable in 11% datasets for both reconstructions. No case was rated as inconclusive. CONCLUSIONS: The in-line implementation of a non-rigid motion-compensated reconstruction framework improved image quality in image-navigated free-breathing, isotropic high-resolution 3D LGE imaging with undersampled spiral-like Cartesian sampling and Dixon water-fat separation compared to translational motion correction of the same datasets. The sharper depictions of LGE may lead to more accurate measures of LGE mass. KEY POINTS: • 3D LGE imaging provides high-resolution detection of myocardial scarring. • Non-rigid motion correction provides better image quality in cardiac MRI. • Non-rigid motion correction may lead to more accurate measures of LGE mass.


Asunto(s)
Medios de Contraste , Gadolinio , Medios de Contraste/farmacología , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Agua
18.
J Magn Reson Imaging ; 56(3): 801-811, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35005810

RESUMEN

BACKGROUND: Magnetic resonance feature tracking (MR-FT) is an imaging technique that quantifies both global and regional myocardial strain. Currently, conventional MR-FT provides a superior signal and contrast-to-noise ratio but has a relatively low temporal resolution. A higher temporal resolution MR-FT technique may provide improved results. PURPOSE: To explore the impact of higher temporal resolution on left ventricular (LV) myocardial strain measurements using MR-FT. STUDY TYPE: Prospective. POPULATION: One hundred and fifty-three participants including five healthy subjects and patients with various cardiac diseases referred to MR for cardiac assessment. FIELD STRENGTH: 3 T, balanced steady-state free precession sequence with and without compressed sensing (temporal resolution: 10 msec and 40 msec, respectively). ASSESSMENT: Conventional (40 msec) and higher (10 msec) temporal resolution data were acquired in all subjects during the same scanning session. Global circumferential strain (GCS), global longitudinal strain (GLS), and global radial strain (GRS) as well as peak systolic and diastolic strain rates (SRs) were measured by MR-FT and compared between the two temporal resolutions. We also performed subgroup analyses according to heart rates (HRs) and LV ejection fraction (LVEF). STATISTICAL TESTS: Paired t-test, Wilcoxon signed-rank test, linear regression analyses, Bland-Altman plots. A P value <0.05 was considered to be statistically significant. RESULTS: GCS and GRS were significantly higher in the 10-msec temporal resolution studies compared to the 40-msec temporal resolution studies (GCS: -13.00 ± 6.58% vs. -12.51 ± 5.76%; GRS: 21.97 ± 14.54% vs. 20.62 ± 12.52%). In the subgroup analyses, significantly higher GLS, GCS, and GRS values were obtained in subjects with LVEF ≥50%, and significantly higher GCS and GRS values were obtained in subjects with HRs <70 bpm when assessed with the 10-msec vs. the 40-msec temporal resolutions. All the peak systolic and diastolic SRs were significantly higher in the higher temporal resolution acquisitions. This was also true for all subgroups. DATA CONCLUSIONS: Higher temporal resolution resulted in significantly higher cardiac strain and SR values using MR-FT and could be beneficial, particularly in patients with LVEF ≥50% and HR <70 bpm. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Ventrículos Cardíacos , Función Ventricular Izquierda , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética/métodos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico , Función Ventricular Izquierda/fisiología
19.
Neuroscience ; 480: 167-177, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34801657

RESUMEN

Decreased levels of Brain-Derived Neurotrophic Factor (BDNF) are a common finding in schizophrenia. Another well-documented protein linked to schizophrenia is intracellular Ca2+-independent Phospholipase (PLA2). However, the potential association between PLA2 and BDNF with regard to schizophrenia has yet to be examined. In the present study, male and female BDNF knockout mice, a possible genetic model of schizophrenia, were exposed to prenatal stress and tested in the nest test, open field test and T-maze. Following behavioral tests, whole brain and plasma samples were harvested to measure the activity of PLA2. BDNF knockout mice showed cognitive deficits in the T-maze. Furthermore, there was a quadratic association of PLA2 with performance in the open field test. Moreover, BDNF deficiency and female sex were associated with elevated plasma PLA2 levels. The cognitive impairment of BDNF heterozygous mice as well as their increased PLA2 activity in plasma is consistent with findings in schizophrenia patients. The particular elevation of PLA2 activity in females may partly explain sex differences of clinical symptoms in schizophrenia (e.g. age of onset, severity of symptoms). Additionally, PLA2 was significantly correlated with body and adrenal weight after weaning, whereby the latter emphasizes the possible connection of PLA2 with steroidogenesis.


Asunto(s)
Trastornos del Conocimiento , Disfunción Cognitiva , Esquizofrenia , Animales , Factor Neurotrófico Derivado del Encéfalo , Femenino , Humanos , Masculino , Ratones , Fosfolipasas A2
20.
BMC Cardiovasc Disord ; 21(1): 580, 2021 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-34876015

RESUMEN

BACKGROUND AND PURPOSE: Conventional cardiac magnetic resonance (CCMR) imaging is usually performed with breath-holding (BH), which is adverse in patients with BH limitations. We explored the ability of a free-breathing CMR (fCMR) protocol to prognosticate in patients with coronary heart diseases (CHD) and limited BH ability. METHODS: Sixty-seven patients with CHD and limited BH abilities were prospectively enrolled in this study. All patients underwent comprehensive fCMR imaging at 3.0 T. The fCMR protocols included compressed sensing (CS) single-shot cine acceleration imaging, and motion-corrected (MOCO), single-shot late gadolinium enhancement (LGE) imaging. Image quality (IQ) of the cine and LGE images was evaluated based on the 5-point Likert scale. The value of fMRI in providing a prognosis in patients with CHD was assessed. Statistical methods included the T test, Mann-Whitney test, Kappa test, Kaplan-Meier curve, Log-rank test, Cox proportional hazard regression analysis, and receiver operating characteristic curves. RESULTS: All IQ scores of the short axis CS-cine and both the short and long axes MOCO LGE images were ≥ 3 points. Over a median follow-up of 31 months (range 3.8-38.2), 25 major adverse cardiovascular events (MACE) occurred. In the univariate analysis, infarction size (IS), left ventricular ejection fraction (LVEF), 3D-Global peak longitudinal strain (3D-GPLS), heart failure classification were significantly associated with MACE. When the significantly univariate MACE predictors, added to the multivariate analysis, which showed IS (HR 1.02; 95% CI 1.00-1.05; p = 0.048) and heart failure with preserved EF (HR 0.20; 95% CI 0.04-0.98; p = 0.048) correlated positively with MACE. The optimal cutoff value for LVEF, 3D-GPLS, and IS in predicting MACE was 34.2%, - 5.7%, and 26.1% respectively, with a sensitivity of 90.5%, 64%, and 96.0% and specificity of 72%, 95.2%, and 85.7% respectively. CONCLUSIONS: The fCMR protocol can be used to make prognostic assessments in patients with CHD and BH limitations by calculating IS and LVEF.


Asunto(s)
Contencion de la Respiración , Enfermedad Coronaria/diagnóstico por imagen , Pulmón/fisiopatología , Imagen por Resonancia Cinemagnética , Anciano , Medios de Contraste , Enfermedad Coronaria/fisiopatología , Femenino , Gadolinio DTPA , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Volumen Sistólico , Función Ventricular Izquierda