Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Front Physiol ; 13: 862212, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35903065

RESUMEN

Inflammatory bowel diseases (IBD) comprise mainly ulcerative colitis (UC) and Crohn´s disease (CD). Both forms present with a chronic inflammation of the (gastro) intestinal tract, which induces excessive changes in the composition of the associated extracellular matrix (ECM). In UC, the inflammation is limited to the colon, whereas it can occur throughout the entire gastrointestinal tract in CD. Tools for early diagnosis of IBD are still very limited and highly invasive and measures for standardized evaluation of structural changes are scarce. To investigate an efficient non-invasive way of diagnosing intestinal inflammation and early changes of the ECM, very small superparamagnetic iron oxide nanoparticles (VSOPs) in magnetic resonance imaging (MRI) were applied in two mouse models of experimental colitis: the dextran sulfate sodium (DSS)-induced colitis and the transfer model of colitis. For further validation of ECM changes and inflammation, tissue sections were analyzed by immunohistochemistry. For in depth ex-vivo investigation of VSOPs localization within the tissue, Europium-doped VSOPs served to visualize the contrast agent by imaging mass cytometry (IMC). VSOPs accumulation in the inflamed colon wall of DSS-induced colitis mice was visualized in T2* weighted MRI scans. Components of the ECM, especially the hyaluronic acid content, were found to influence VSOPs binding. Using IMC, co-localization of VSOPs with macrophages and endothelial cells in colon tissue was shown. In contrast to the DSS model, colonic inflammation could not be visualized with VSOP-enhanced MRI in transfer colitis. VSOPs present a potential contrast agent for contrast-enhanced MRI to detect intestinal inflammation in mice at an early stage and in a less invasive manner depending on hyaluronic acid content.

2.
Mol Imaging ; 11(5): 383-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22954182

RESUMEN

Superparamagnetic iron oxide particles are used as potent contrast agents in magnetic resonance imaging. In histology, these particles are frequently visualized by Prussian blue iron staining of aldehyde-fixed, paraffin-embedded tissues. Recently, zinc salt-based fixative was shown to preserve enzyme activity in paraffin-embedded tissues. In this study, we demonstrate that zinc fixation allows combining in situ zymography with fluorescence immunohistochemistry (IHC) and iron staining for advanced biologic investigation of iron oxide particle accumulation. Very small iron oxide particles, developed for magnetic resonance angiography, were applied intravenously to BALB/c nude mice. After 3 hours, spleens were explanted and subjected to zinc fixation and paraffin embedding. Cut tissue sections were further processed to in situ zymography, IHC, and Prussian blue staining procedures. The combination of in situ zymography as well as IHC with subsequent Prussian blue iron staining on zinc-fixed paraffin-embedded tissues resulted in excellent histologic images of enzyme activity, protease distribution, and iron oxide particle accumulation. The combination of all three stains on a single section allowed direct comparison with only moderate degradation of fluorescein isothiocyanate-labeled substrate. This protocol is useful for investigating the biologic environment of accumulating iron oxide particles, with excellent preservation of morphology.


Asunto(s)
Inmunohistoquímica/métodos , Nanopartículas de Magnetita/química , Fijación del Tejido/métodos , Zinc/química , Animales , Colorantes , Ferrocianuros , Fijadores/química , Hierro/análisis , Metaloproteinasa 2 de la Matriz/análisis , Metaloproteinasa 9 de la Matriz/análisis , Ratones , Ratones Desnudos , Microscopía Fluorescente , Adhesión en Parafina , Bazo/química , Bazo/metabolismo
3.
J Neuroinflammation ; 6: 20, 2009 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-19660125

RESUMEN

BACKGROUND: Gadopentate dimeglumine (Gd-DTPA) enhanced magnetic resonance imaging (MRI) is widely applied for the visualization of blood brain barrier (BBB) breakdown in multiple sclerosis and its animal model, experimental autoimmune encephalomyelitis (EAE). Recently, the potential of magnetic nanoparticles to detect macrophage infiltration by MRI was demonstrated. We here investigated a new class of very small superparamagnetic iron oxide particles (VSOP) as novel contrast medium in murine adoptive-transfer EAE. METHODS: EAE was induced in 17 mice via transfer of proteolipid protein specific T cells. MR images were obtained before and after application of Gd-DTPA and VSOP on a 7 Tesla rodent MR scanner. The enhancement pattern of the two contrast agents was compared, and correlated to histology, including Prussian Blue staining for VSOP detection and immunofluorescent staining against IBA-1 to identify macrophages/microglia. RESULTS: Both contrast media depicted BBB breakdown in 42 lesions, although differing in plaques appearances and shapes. Furthermore, 13 lesions could be exclusively visualized by VSOP. In the subsequent histological analysis, VSOP was localized to microglia/macrophages, and also diffusely dispersed within the extracellular matrix. CONCLUSION: VSOP showed a higher sensitivity in detecting BBB alterations compared to Gd-DTPA enhanced MRI, providing complementary information of macrophage/microglia activity in inflammatory plaques that has not been visualized by conventional means.


Asunto(s)
Barrera Hematoencefálica/patología , Encefalitis/patología , Encefalomielitis Autoinmune Experimental/patología , Imagen por Resonancia Magnética/métodos , Nanopartículas , Traslado Adoptivo/métodos , Animales , Barrera Hematoencefálica/fisiopatología , Encéfalo/irrigación sanguínea , Encéfalo/patología , Encéfalo/fisiopatología , Capilares/patología , Capilares/fisiopatología , Células Cultivadas , Quimiotaxis de Leucocito/inmunología , Medios de Contraste/química , Modelos Animales de Enfermedad , Encefalitis/fisiopatología , Encefalomielitis Autoinmune Experimental/fisiopatología , Matriz Extracelular/patología , Femenino , Compuestos Férricos/química , Gliosis/patología , Gliosis/fisiopatología , Macrófagos/patología , Ratones , Microcirculación/inmunología , Microglía/patología , Esclerosis Múltiple/patología , Esclerosis Múltiple/fisiopatología , Nanopartículas/química
4.
Eur J Neurosci ; 26(1): 190-8, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17596194

RESUMEN

The value of experimental autoimmune encephalomyelitis (EAE), an animal model of multiple sclerosis, in deriving novel diagnostic and therapeutic input has been subject to recent debate. This study is the first to report a disseminated distribution of plaques including cranial nerves, prior to or at early stages of disease in murine adoptive transfer EAE, irrespective of the development of clinical symptoms. We induced EAE by adoptive proteolipid protein-specific T-cell transfer in 26 female SJL/J mice, and applied high-field-strength magnetic resonance imaging (MRI) scans longitudinally, assessing blood-brain barrier (BBB) disruption by gadopentate dimeglumine enhancement. We visualized inflammatory nerve injury by gadofluorine M accumulation, and phagocytic cells in inflamed tissue by very small anionic iron oxide particles (VSOP-C184). MRI was correlated with immunohistological sections. In this study, we discovered very early BBB breakdown of white and grey brain matter in 25 mice; one mouse developed exclusively spinal cord inflammation. Widely disseminated contrast-enhancing lesions preceded the onset of disease in 10 animals. Such lesions were present despite the absence of any clinical disease formation in four mice, and coincided with the first detectable symptoms in others. Cranial nerves, predominantly the optic and trigeminal nerves, showed signal intensity changes in nuclei and fascicles of 14 mice. At all sites of MRI lesions we detected cellular infiltrates on corresponding histological sections. The discrepancy between the disease burden visualized by MRI and the extent of disability indeed mimics the human clinico-radiological paradox. MRI should therefore be implemented into evaluational in vivo routines of future therapeutic EAE studies.


Asunto(s)
Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Animales , Barrera Hematoencefálica/fisiología , Encéfalo/patología , Cerebelo/patología , Medios de Contraste , Nervios Craneales/patología , Modelos Animales de Enfermedad , Endocitosis/fisiología , Femenino , Fluorocarburos , Gadolinio DTPA , Procesamiento de Imagen Asistido por Computador , Inmunohistoquímica , Imagen por Resonancia Magnética , Ratones , Microglía/patología , Compuestos Organometálicos , Fagocitosis/efectos de los fármacos , Radiografía , Linfocitos T/fisiología
5.
Anticancer Drugs ; 16(8): 855-61, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16096433

RESUMEN

Therapeutic efficacy of the novel matrix metalloproteinase (MMP) inhibitor, Ro 28-2653 (5-biphenyl-4-yl-5-[4-(-nitro-phenyl)-piperazin-1-yl]-pyrimidine-2,4,6-trione), has been shown in various models of different tumor entities. The tumor growth-reducing effect has been demonstrated in the orthotopic rat prostate Dunning model (subline MatLyLu). Based on these results we investigated Ro 28-2653 in combination with estramustine on the G subline of the Dunning tumor. This subline is characterized by a low metastatic ability and androgen sensitivity. Efficacy was determined by recording tumor growth in vivo by magnetic resonance imaging (MRI). Tumor cells were injected into the prostates of 81 Copenhagen rats. MRI was performed at day 100 and at day 126 after tumor cell injection. The duration of therapy was 17 days with daily oral application of Ro 28-2653 (100 mg/kg) and four i.p. injections of estramustine (7.5 mg/kg). Histological evaluations were conducted to provide further information about the effects on tumor morphology. Orthotopic tumor induction was successful in 100% of the animals. Tumor volume calculations with MRI showed a significant difference between the control groups, the animals treated with Ro 28-2653, and the animals treated with the combination of Ro 28-2653 and estramustine. The new MMP inhibitor Ro 28-2653 reduces tumor growth and provides a compatible therapeutic alternative for patients with prostate cancer.


Asunto(s)
Antineoplásicos Hormonales/uso terapéutico , Estramustina/uso terapéutico , Inhibidores de la Metaloproteinasa de la Matriz , Neoplasias Hormono-Dependientes/tratamiento farmacológico , Piperazinas/uso terapéutico , Neoplasias de la Próstata/tratamiento farmacológico , Pirimidinas/uso terapéutico , Animales , Modelos Animales de Enfermedad , Relación Dosis-Respuesta a Droga , Quimioterapia Combinada , Masculino , Metaloproteinasas de la Matriz/metabolismo , Neoplasias Hormono-Dependientes/secundario , Neoplasias de la Próstata/patología , Ratas , Ratas Endogámicas , Tasa de Supervivencia , Factores de Tiempo , Células Tumorales Cultivadas
6.
Invest Radiol ; 39(6): 357-64, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15167102

RESUMEN

OBJECTIVE: Comparison of coronary artery visualization by multislice spiral CT (MSCT) and electron-beam CT (EBCT). MATERIALS AND METHODS: Six minipigs underwent MSCT (collimation 4 x 1 mm, gantry rotation time 500 milliseconds, acquisition time per cardiac cycle 126 +/- 30 milliseconds) and EBCT (slice thickness 1.5 mm, acquisition time per scan 100 milliseconds). Visualized vessel length and contour sharpness was measured, contrast-to-noise ratios were calculated, and the frequency of motion artifacts were evaluated. RESULTS: MSCT depicted significantly longer segments of the coronary tree than EBCT (length: 248.8 vs. 222.8 mm; P < 0.05), delineated the vessel contours more sharply (slope of density curves: 219.2 vs. 160.2 DeltaHU/mm; P < 0.05), and had a higher contrast-to-noise ratio (13.4 vs. 7.3; P < 0.05). The frequency of motion artifacts did not differ between both modalities (94.7% vs. 95.7% of visualized vessel length; P > 0.05). CONCLUSIONS: Because its higher spatial resolution and lower image noise, MSCT seems to be superior to EBCT in the visualization of the coronary arteries. Despite different temporal resolutions motion artifacts seem to be similar with both modalities.


Asunto(s)
Angiografía Coronaria/métodos , Tomografía Computarizada Espiral , Tomografía Computarizada por Rayos X , Animales , Artefactos , Individualidad , Dosis de Radiación , Porcinos , Porcinos Enanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...