Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Int Ophthalmol ; 44(1): 302, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38954134

RESUMEN

PURPOSE: To compare early changes in the corneal biomechanical parameters after photorefractive keratectomy (PRK) and small incision lenticule extraction (SMILE) and their correlations with corneal shape parameters. METHODS: One hundred twenty four eyes received myopic PRK and SMILE for similar amounts of myopia. Corneal tomography with Pentacam HR, biomechanical parameters using Corvis ST, and Ocular Response Analyzer (ORA) were evaluated before and 2 weeks after surgery. The change in each parameter was compared between groups, while the difference in central corneal thickness and cornea-compensated intraocular pressure measured before and after surgery were considered as covariates. RESULTS: A significant reduction was seen in the corneal stiffness parameter at first applanation, and an increase in deformation amplitude ratio (DAR), and integrated inverse radius (IIR) in both groups after surgery (p < 0.001) Changes in DAR, and IIR were significantly greater in the SMILE than in the PRK group (p < 0.001) Corneal hysteresis (CH) and corneal resistance factor (CRF) decreased in both SMILE and PRK groups after surgery, (p < 0.001) with no statistically significant difference between groups (p > 0.05) Among new Corvis ST parameters, DAR showed a significant correlation with changes in Ambrosio relational thickness in both groups (p < 0.05). CONCLUSIONS: Both techniques caused significant changes in corneal biomechanics in the early postoperative period, with greater elastic changes in the SMILE group compared to the PRK group, likely due to lower tension in the SMILE cap and thinner residual stromal bed in SMILE. There were no differences in viscoelastic changes between them, so the lower CH may reflect the volume of tissue removed.


Asunto(s)
Córnea , Elasticidad , Miopía , Queratectomía Fotorrefractiva , Humanos , Queratectomía Fotorrefractiva/métodos , Miopía/cirugía , Miopía/fisiopatología , Córnea/cirugía , Córnea/fisiopatología , Córnea/diagnóstico por imagen , Femenino , Masculino , Adulto , Elasticidad/fisiología , Fenómenos Biomecánicos , Adulto Joven , Láseres de Excímeros/uso terapéutico , Presión Intraocular/fisiología , Cirugía Laser de Córnea/métodos , Refracción Ocular/fisiología , Topografía de la Córnea , Sustancia Propia/cirugía , Periodo Posoperatorio , Agudeza Visual/fisiología , Estudios Prospectivos , Estudios de Seguimiento
2.
Eye Contact Lens ; 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38978191

RESUMEN

OBJECTIVES: To compare astigmatism correction after photorefractive keratectomy (PRK) using three excimer laser devices, Alcon Wavelight EX500, Schwind Amaris 1,050, and Technolas Teneo317 M2. METHODS: This retrospective study included 414 eyes from 414 subjects with a history of PRK performed using Alcon Wavelight (n=172), Schwind Amaris (n=122), and Technolas (n=120). Uncorrected & corrected distance visual acuity (UDVA & CDVA), and refractive status (spherical equivalent (SE) and vector analysis (J0 and J45)) were postoperatively recorded at the 6-month and 12-month examinations. RESULTS: The mean CDVA and J45 at 6-month and 12-month showed no statistically significant difference among the three different excimer lasers (P>0.05). There was a statistically significant difference in mean UDVA and J0 at 6-month and 12-month after PRK among the three groups, with no statistically significant difference between Alcon Wavelight and Schwind Amaris lasers, while both of the prior lasers showed a significant difference with the Technolas laser. The highest and lowest changes in the magnitude of J0 in 6-month and 12-month follow-ups were seen for the Alcon Wavelight and Technolas groups, respectively. Both Schwind Amaris and Technolas had a small hyperopic SE while the Alcon Wavelight's SE was minimally myopic. This difference in SE between Alcon Wavelight and both Schwind Amaris and Technolas reached statistical significance. CONCLUSION: While all three lasers performed well in reducing preoperative astigmatism; however, the Alcon Wavelight and Schwind Amaris were more effective in correcting astigmatism than the Technolas. The difference between the Alcon Wavelight and Schwind Amaris did not reach statistical significance.

3.
Int Ophthalmol ; 44(1): 22, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38324098

RESUMEN

PURPOSE: To compare the corneal biomechanical parameters in healthy corneas with symmetric and asymmetric bow-tie topographic patterns. METHODS: In this cross-sectional study, 144 eyes were divided based on inferior-superior asymmetry value (I-S) into symmetric (zero I-S: - 0.50 to + 0.50 D) and asymmetric bow-tie topographic patterns with inferior (positive I-S: + 0.51 to + 1.4 D) or superior (negative I-S: - 2.5 to - 0.51 D) steepening. The biomechanical assessment was performed using Corvis ST and ocular response analyzer (ORA). A general linear model univariate analysis was used to compare the parameters, while the central corneal thickness, intraocular pressure, and age were considered covariates. RESULTS: Only the peak distance (PD) at the highest concavity phase (P = 0.007) and tomographic biomechanical index (TBI, P = 0.001) showed statistically significant differences between the three groups. For TBI, this difference was statistically significant between the positive I-S group separately with the zero I-S group (P < 0.001), and with the negative I-S group (P = 0.022). For PD, the significant difference was between the negative I-S group separately with zero I-S (P = 0.019), and positive I-S groups (P = 0.018). There was a statistically significant correlation between the I-S value with PD (r = 0.281, P = 0.001) and TBI (r = 0.170, P = 0.044). CONCLUSIONS: Most corneal biomechanical parameters are not statistically significant compared to the zero I-S group. However, superior steepening is associated with a stiffer response based solely on the shorter PD values seen in this group, and the group with the inferior steepening shows the highest or more suspicious values based on TBI.


Asunto(s)
Córnea , Estado de Salud , Humanos , Estudios Transversales , Presión Intraocular , Tonometría Ocular
4.
Exp Eye Res ; 238: 109742, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38040051

RESUMEN

Keratoconus (KC) is characterized by the predominant primary ectatic disease, affecting the cornea, necessitating corneal transplants in some cases. While some loci associated with KC risk have been identified, the understanding of the disease remains limited. Superoxide dismutase (SOD) enzymes play a crucial role in countering the reactive oxygen species and providing protection against oxidative stress (OS). Accordingly, the objective of this study was to investigate a potential association of a 50 nucleotide base pairs (bp) insertion/deletion (I/D) within the SOD1 promoter, and the located 1684 bp upstream of the SOD1 ATG, with KC in the Iranian population. Additionally, an assessment was conducted on SOD activity and the total antioxidant capacity (TAC), as determined by the ferric reducing-antioxidant power assay, along with malondialdehyde (MDA) levels. In this case-control study, genomic DNA was extracted from the blood cells of KC (n = 402) and healthy (n = 331) individuals. The genotype of this gene was determined using the PCR technique. Furthermore, the amount of SOD enzyme activity and the MDA and TAC levels were measured in the serum of the study groups. The (I/I) genotype was present in 84.23%, the (I/D) genotype in 15.06%, and the (D/D) genotype in 0.69% of both groups. A statistically significant relationship was seen between different genotypes and TAC, MDA, and SOD1 activity indices (P < 0.05). Individuals with the D/D genotype exhibited a decrease in total antioxidant capacity, an increase in the amount of MDA, and a decrease in SOD1 enzyme activity (P < 0.05). Moreover, the logistic regression analysis of KC development indicated that elevated levels of MDA increased the risk of KC incidence in the patient group compared to the healthy group, while a higher activity of SOD1 and greater values of TAC decreased the KC risk. The removal of the 50 bp fragment reduced SOD1 activity and elevated OS levels, thereby impacting the oxidant-antioxidant balance. This could potentially play a significant role in individuals afflicted by KC.


Asunto(s)
Queratocono , Estrés Oxidativo , Superóxido Dismutasa-1 , Queratocono/epidemiología , Queratocono/genética , Queratocono/terapia , Estudios de Casos y Controles , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Humanos , Masculino , Femenino , Superóxido Dismutasa-1/genética , Modelos Logísticos , Curva ROC , Mutación INDEL
6.
Sci Rep ; 13(1): 20586, 2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37996439

RESUMEN

Detecting clinical keratoconus (KCN) poses a challenging and time-consuming task. During the diagnostic process, ophthalmologists are required to review demographic and clinical ophthalmic examinations in order to make an accurate diagnosis. This study aims to develop and evaluate the accuracy of deep convolutional neural network (CNN) models for the detection of keratoconus (KCN) using corneal topographic maps. We retrospectively collected 1758 corneal images (978 normal and 780 keratoconus) from 1010 subjects of the KCN group with clinically evident keratoconus and the normal group with regular astigmatism. To expand the dataset, we developed a model using Variational Auto Encoder (VAE) to generate and augment images, resulting in a dataset of 4000 samples. Four deep learning models were used to extract and identify deep corneal features of original and synthesized images. We demonstrated that the utilization of synthesized images during training process increased classification performance. The overall average accuracy of the deep learning models ranged from 99% for VGG16 to 95% for EfficientNet-B0. All CNN models exhibited sensitivity and specificity above 0.94, with the VGG16 model achieving an AUC of 0.99. The customized CNN model achieved satisfactory results with an accuracy and AUC of 0.97 at a much faster processing speed compared to other models. In conclusion, the DL models showed high accuracy in screening for keratoconus based on corneal topography images. This is a development toward the potential clinical implementation of a more enhanced computer-aided diagnosis (CAD) system for KCN detection, which would aid ophthalmologists in validating the clinical decision and carrying out prompt and precise KCN treatment.


Asunto(s)
Aprendizaje Profundo , Queratocono , Humanos , Queratocono/diagnóstico por imagen , Estudios Retrospectivos , Redes Neurales de la Computación , Computadores
7.
Artículo en Inglés | MEDLINE | ID: mdl-37641667

RESUMEN

Background: Wound construction is a critical step in phacoemulsification. Using anterior segment optical coherence tomography (AS-OCT), we compared the morphological features and complications of main incisions made by junior or senior residents during phacoemulsification. Methods: This cross-sectional comparative study included eyes with senile cataracts that underwent uneventful phacoemulsification with a clear corneal incision made by seven senior and eight junior ophthalmology residents. All eyes underwent postoperative image acquisition using AS-OCT on day one and at three months, examining for morphological features and potential complications of the main incision. Results: We included 50 eyes of 50 patients with a male-to-female ratio of 22 (44%) to 28 (56%); 26 (52%) were operated on by junior residents and 24 (48%) by seniors. The mean geometric features of the main incisions and the frequency of early and late wound complications were comparable between the two groups (all P > 0.05). A significant correlation was found between the incision length and angle with the superior (r = + 0.80; P < 0.001 and r = - 0.63; P < 0.001, respectively) and inferior (r = + 0.84; P < 0.001 and r = - 0.68; P < 0.001, respectively) areas of the incision, as well as between the length and angle of incision (r = - 0.74; P < 0.001). The number of planes in the wound architecture was not significantly different according to senior or junior resident status (P > 0.05). Although the number of eyes with stromal hydration was significantly greater for junior residents than for seniors (P < 0.001), the corneal thickness at the entrance to the cornea or the anterior chamber, presence of endothelial wound gaping, and Descemet's membrane detachment were comparable between eyes with and without stromal hydration (all P > 0.05). At three months, 29 (58%) patients returned for examination, in whom seven (24%) had late wound complications. Conclusions: This study found no significant differences in the performances of junior and senior residents in terms of wound construction or its associated complications. However, considering the overall rate of some observed wound-related complications, we recommended revision of the resident educational curriculum concerning the structure and complications of the main incision.

8.
Eur J Ophthalmol ; 33(6): 2114-2122, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37113031

RESUMEN

OBJECTIVES: To compare changes in corneal biomechanical parameters one year after corneal cross-linking (CXL) in keratoconus (KCN) eyes of different severities. METHODS: Seventy-five eyes with mild, moderate, and severe grades of KCN (n = 24, 31, and 20 eyes, respectively) that were treated with CXL, based upon the standard Dresden protocol, were included. The corneal biomechanical assessment was performed using Corvis ST and Ocular Response Analyzer (ORA). Changes in Corvis's dynamic corneal response (DCR) parameters and ORA's derived parameters (corneal hysteresis (CH), and corneal resistance factor (CRF)) were assessed whilst the corneal thickness and intraocular pressure were considered as covariates. RESULTS: There was no statistically significant difference in the corneal biomechanical parameters obtained using both devices after surgery separately in different KCN grades, except for the deformation amplitude (DA) in the severe KCN group (P = 0.017). Changes in the classic parameters of the highest concavity phase of Corvis ST (peak distance, radius, and DA) were more positive and in the newer parameters (integrated inverse radius (IIR), deformation amplitude ratio (DAR)) more negative in the severe group compared to the other groups. Also, the mean change in CH (P = 0.710), and CRF (P = 0.565), showed a negative shift in higher grades of KCN; however, there was no significant difference in the mean changes of all parameters between different groups. (P > 0.05). CONCLUSIONS: Similar changes in the Corvis ST and ORA parameters in mild, moderate, and severe KCN indicate biomechanical stability and the effective role of CXL in stopping the progressive nature of keratoconus in eyes of varying severities one year after CXL.

9.
J Cataract Refract Surg ; 49(3): 234-238, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36449663

RESUMEN

PURPOSE: To compare corneal biomechanical parameters of normal thin corneas with matched keratoconus eyes. SETTING: Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. DESIGN: Cross-sectional comparative study. METHODS: Dynamic corneal response parameters of Corvis ST were compared in 61 eyes with keratoconus with 61 matched healthy thin corneas (corneal thinnest point <500 µm), while corneal thickness, biomechanically corrected intraocular pressure, and age were considered covariates. The receiving operator sensitivity curve analysis was used to determine the cutoff point with the highest sensitivity and specificity, and the area under the curve (AUC) for each parameter. RESULTS: All biomechanical parameters were statistically significant between the 2 groups except for the first ( P = .947) and second ( P = .582) applanation length, first ( P = .783) and second ( P = .301) applanation velocity, and deformation amplitude in the highest concavity phase ( P = .106). The highest mean difference between groups (12.89 ± 2.03 mm Hg/mm) was related to the stiffness parameter at the first applanation (SPA1). Although the Corvis biomechanical index and tomographic biomechanical index had the highest detection ability based on their AUC (0.912 and 0.959, respectively), among the standard and combined biomechanical parameters except for keratoconus screening parameters, the highest discriminative ability was related to SPA1 with AUC, sensitivity, and specificity of 0.793, 60.66%, and 90.16%, respectively. CONCLUSIONS: Keratoconus corneas were significantly softer compared with healthy thin corneas of matched thickness. Optimal cutoff points close to the maximum value defined for screening parameters limit their clinical use for differentiation purposes in these particular types of cases.


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Estudios Transversales , Topografía de la Córnea/métodos , Fenómenos Biomecánicos , Córnea
10.
Eye (Lond) ; 37(8): 1665-1672, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36038724

RESUMEN

PURPOSE: To assess the detection ability of corneal biomechanical parameters for early diagnosis of ectasia. METHODS: This retrospective descriptive-analytical study included 134 normal eyes (control group) from 134 healthy subjects and 128 eyes with asymmetric contralateral corneal ectasia with normal topography (ACE-NT, study group) from 128 subjects with definite keratoconus in the opposite eye. Placido-disk-based corneal topography with TMS-4, Scheimpflug corneal tomography with Pentacam HR, and corneal biomechanical assessment with Corvis ST and ocular response analyzer (ORA) were performed. A general linear model was used to compare Corvis ST and ORA biomechanical parameters between groups, while central corneal thickness (CCT) and biomechanically corrected intraocular pressure (bIOP) were considered covariates. Receiving operator sensitivity curve (ROC) analysis was used to determine the cut-off point with the highest sensitivity and specificity along with the area under the curve (AUC) for each parameter. RESULT: All parameters of Corvis ST and ORA showed a statistically significant difference between the two groups except for the first (P = 0.865) and second (P = 0.226) applanation lengths, and deformation amplitude (P = 0.936). The discriminative analysis of corneal biomechanical showed that the highest accuracy for the classic, new, and combined parameters of Corvis ST was related to HCR (AUC: 0.766), IR & DAR (0.846), and TBI (0.966), respectively. Using ORA, the corneal resistance factor (0.866) had a higher detection ability than corneal hysteresis (0.826). CONCLUSIONS: TBI has the best accuracy and the highest effect size for differential diagnosis of normal from ACE-NT eyes with a cut-off point of 0.24.


Asunto(s)
Córnea , Queratocono , Humanos , Estudios Retrospectivos , Dilatación Patológica/diagnóstico , Topografía de la Córnea/métodos , Queratocono/diagnóstico , Curva ROC , Fenómenos Biomecánicos , Diagnóstico Precoz , Paquimetría Corneal
11.
Case Rep Ophthalmol Med ; 2022: 2381703, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35990537

RESUMEN

Purpose: To present the youngest age ever reported for acute corneal hydrops with total corneal edema in a child with advanced bilateral keratoconus. Methods: Patient presentation in ophthalmic clinic. The patient underwent various clinical tests and examinations including anterior segment optical coherence tomography (AS-OCT) and Scheimpflug corneal tomography. Results: A 5-year-old girl presented with uncorrected distance visual acuity (UDVA) of 0.4 in the right eye and nonmeasurable UDVA associated with severe photophobia in her left eye of a 3-day duration. Intraocular pressure using the iCare tonometer was 14 and 5 mmHg in the right and left eyes, respectively. An old corneal hydrops scar and posterior subcapsular cataract (PSC) in the right eye and a total limbus to limbus corneal hydrops in the left eye were observed on slit-lamp examinations. Scheimpflug corneal tomography was possible in the right eye but, due to excessive irregularity and scaring, was not possible in the left eye. Corneal thinning and scarring were evident in the anterior segment optical coherence tomography in the right eye and very edematous cornea associated with stromal cleft and epithelial bullae in the left eye. A management plan consisting of topical hypertonic solution and ointment was started to reduce her symptoms. Conclusion: Acute corneal hydrops may be the presenting sign of keratoconus; however, extensive hydrops involving the total cornea area at a very young age is very rare and has not been previously reported in the literature.

12.
Optom Vis Sci ; 99(5): 443-448, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35511121

RESUMEN

SIGNIFICANCE: Corneal epithelial thickness mapping has a wide range of applications including screening for keratoconus, screening for anterior basement membrane dystrophy, and assessment of dry eye. It also plays an important role in corneal laser refractive surgery. These all require an understanding of the epithelial thickness profile in a normal cornea as a reference. PURPOSE: This study aimed to compare corneal epithelial thickness along different meridians in normal eyes with different types of corneal astigmatism. METHODS: In this cross-sectional study, corneal topography and epithelial thickness mapping by anterior segment optical coherence tomography was performed for 154 normal eyes. Corneal astigmatism was classified based on the orientation of the steepest corneal meridian (with-the-rule [WTR], against-the-rule [ATR], and oblique) and the amount (low, moderate, and high). On a 9-mm epithelial thickness map, the thickness along the horizontal (180°), vertical (90°), and diagonal (45 and 135°) meridians was calculated. RESULT: With-the-rule, oblique, and ATR astigmatisms were observed in 40, 31, and 29% of the eyes, respectively. In all types of astigmatism, the mean epithelial thickness was greater along the 180° meridian and thinner along the 90° meridian. There was no statistically significant difference in mean thickness along different meridians for WTR (P = .24) and oblique (P = .46) astigmatism, whereas the difference along the 180 and 90° meridians (P = .003) for ATR astigmatism was statistically significant. Also, there was a statistically significant difference in thickness in different types of astigmatism separately for each meridian (P < .05) so that the highest and lowest thicknesses were seen for ATR and oblique astigmatisms, respectively. The epithelial thickness showed no statistical difference in various amounts of astigmatism along different meridians. CONCLUSIONS: Thicker epithelium along the horizontal meridian in ATR may point to the surface regularizing functions of the epithelium to create a regular and smooth surface, but thickness assessment along the different meridians in oblique and WTR showed no curvature-dependent changes.


Asunto(s)
Astigmatismo , Queratocono , Astigmatismo/diagnóstico , Córnea , Topografía de la Córnea/métodos , Estudios Transversales , Humanos , Queratocono/diagnóstico
13.
J Refract Surg ; 37(10): 700-706, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34661479

RESUMEN

PURPOSE: To assess corneal stability and corrected distance visual acuity (CDVA) 3, 6, and 12 months following corneal cross-linking (CXL) using the ABCD keratoconus staging system. METHODS: This prospective longitudinal study included 31 eyes with keratoconus receiving CXL based on the standard Dresden protocol. CDVA, refraction, and Scheimpflug tomography with the Pentacam HR (Oculus Optikgeräte GmbH) were evaluated before and after surgery. Geometric and functional changes were assessed using the actual values and staging of each element of the ABCD keratoconus staging system. A, B, C, and D refer to the anterior and posterior radii of curvature in a 3-mm zone centered on the cor-neal thinnest point, minimum corneal thickness, and CDVA, respectively. RESULTS: There were no significant changes in the actual values of anterior radius of curvature (P = .497) and CDVA (P = .082), whereas posterior radius of curvature (P = .007) and corneal thinnest point (P < .001) showed significant changes statistically. Pairwise comparison showed only a statistically significant steepening in posterior radius of curvature at 3 months after CXL compared to the preoperative radius (P = .002) and a significant decrease in corneal thinnest point at 3 (P < .001) and 6 (P = .028) months after CXL compared to baseline assessment. Staging of each element of the ABCD keratoconus staging system indicated no change between baseline and 3, 6, and 12 months after CXL. CONCLUSIONS: The geometric and functional parameters included in the ABCD keratoconus staging system showed stability of corneal status and CDVA 1 year after CXL. [J Refract Surg. 2021;37(10):700-706.].


Asunto(s)
Queratocono , Fotoquimioterapia , Colágeno/uso terapéutico , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Queratocono/tratamiento farmacológico , Estudios Longitudinales , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta , Agudeza Visual
14.
BMJ Open Ophthalmol ; 6(1): e000824, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34337155

RESUMEN

OBJECTIVE: To evaluate the accuracy of convolutional neural networks technique (CNN) in detecting keratoconus using colour-coded corneal maps obtained by a Scheimpflug camera. DESIGN: Multicentre retrospective study. METHODS AND ANALYSIS: We included the images of keratoconic and healthy volunteers' eyes provided by three centres: Royal Liverpool University Hospital (Liverpool, UK), Sedaghat Eye Clinic (Mashhad, Iran) and The New Zealand National Eye Center (New Zealand). Corneal tomography scans were used to train and test CNN models, which included healthy controls. Keratoconic scans were classified according to the Amsler-Krumeich classification. Keratoconic scans from Iran were used as an independent testing set. Four maps were considered for each scan: axial map, anterior and posterior elevation map, and pachymetry map. RESULTS: A CNN model detected keratoconus versus health eyes with an accuracy of 0.9785 on the testing set, considering all four maps concatenated. Considering each map independently, the accuracy was 0.9283 for axial map, 0.9642 for thickness map, 0.9642 for the front elevation map and 0.9749 for the back elevation map. The accuracy of models in recognising between healthy controls and stage 1 was 0.90, between stages 1 and 2 was 0.9032, and between stages 2 and 3 was 0.8537 using the concatenated map. CONCLUSION: CNN provides excellent detection performance for keratoconus and accurately grades different severities of disease using the colour-coded maps obtained by the Scheimpflug camera. CNN has the potential to be further developed, validated and adopted for screening and management of keratoconus.

15.
Sci Rep ; 11(1): 11971, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-34099765

RESUMEN

Corneal biomechanical parameters were compared in 100 keratoconus eyes with abnormal elevation on the back corneal surface only (group 1), versus both the back and front surfaces (group 2). Scheimpflug tomography with Pentacam HR, corneal biomechanical assessments using Corvis ST and Ocular Response Analyzer (ORA) and corneal epithelium thickness maps using anterior segment optical coherence tomography were assessed. There were no significant differences in the IOP measured using Corvis ST and ORA, age or sex between the two groups. Statistically significant differences were found in all corneal shape parameters and all new parameters of Corvis ST: corneal stiffness parameter at first applanation (SP-A1), integrated inverse radius (IR) and deformation amplitude ratio (DAR)) between groups (p < 0.001). The classic parameters of ORA including corneal hysteresis (CH) and corneal resistance factor (CRF) were about 1.00 mmHg higher in group 1 (p < 0.001). In conclusion, keratoconus eyes with abnormal elevation limited to the back corneal surface have lower grade, stiffer corneal biomechanical parameters and less asymmetric shape. This is consistent with progressive biomechanical weakening from the first detectable back surface elevation to manifestation on the front surface as the severity overwhelms the ability of the epithelium to compensate.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Córnea/anomalías , Queratocono/cirugía , Adolescente , Adulto , Área Bajo la Curva , Paquimetría Corneal , Topografía de la Córnea , Elasticidad , Femenino , Voluntarios Sanos , Humanos , Presión Intraocular/fisiología , Masculino
16.
Curr Eye Res ; 46(11): 1666-1672, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33998941

RESUMEN

Purpose: To compare the corneal cone location on different maps and instruments, and their agreements, with elevation maps.Methods: In 90 left eyes with bilateral keratoconus, the apex of cone location was determined based on the maximum simulated keratometry (Kmax) location on the anterior sagittal curvature map by Pentacam HR, the maximum curvature on the mean curvature map by ATLAS 9000, most elevated point of the island of positive elevation relative to the best fit sphere on the front and back corneal elevation maps by Pentacam HR, and thinnest point on the thickness map by Pentacam HR and Orbscan, and the thinnest points on pachymetry and epithelial thickness maps by RTVue OCT.Results: There was a significant difference among the location on different maps along the x- and y-axes (p < .001). The lowest agreement with the cone apex on both front and back elevation maps was for the anterior sagittal curvature map and the highest agreement for the Pentacam thickness map. The majority of keratoconus cone apexes were displaced in the inferotemporal direction on the different maps except for the epithelial thickness maps.Conclusions: Despite the variability between different devices and methods; the thickness map on the Pentacam HR showed the highest correlation with the front and back elevation maps, while the RTVue epithelial thickness map showed the poorest correlation. Based on this study, epithelial thickness maps and anterior curvature maps should be utilized with caution to determine the location of the cone.


Asunto(s)
Córnea/patología , Paquimetría Corneal , Topografía de la Córnea , Queratocono/diagnóstico , Tomografía de Coherencia Óptica , Adolescente , Adulto , Humanos , Persona de Mediana Edad , Curva ROC , Refracción Ocular , Microscopía con Lámpara de Hendidura , Adulto Joven
17.
Iran J Parasitol ; 16(1): 111-121, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33786053

RESUMEN

BACKGROUND: The genus Acanthamoeba is a free-living opportunistic protozoan parasite, which widely distributed in soil and fresh water. Acanthamoeba keratitis, which causes a sight-threating infection of the cornea, is going to rise in Iran and worldwide. The aim of this study was to compare direct microscopy, culture and PCR for detection of Acanthamoeba spp. in clinical samples and to determine the genotypes of Acanthamoeba spp. by sequencing 18SrRNA gene. METHODS: Among patients clinically suspected to AK referred to a tertiary ophthalmology center at Mashhad, northeastern Iran. During 2017-18, twenty corneal scrapes specimens obtained. The samples were divided into three parts, subjected to direct microscopic examination, culture onto non-nutrient agar and PCR technique. Sensitivity, specificity, accuracy and likelihood ratio were evaluated. RESULTS: Among 20 persons clinically suspected to amoebic keratitis, 13(69.2%) patients definitely diagnosed as Acanthamoeba keratitis. Wearing contact lens, eye trauma due to foreign particle and swimming in fresh water were the main predisposing factors. Most of patients suffered from pain and photophobia. Corneal ring infiltration and epithelial defect were common clinical sings. Direct examination had the lowest sensitivity and sensitivity of both Nelson-PCR and JDP-PCR methods were equal and highest. In addition, the results of sequencing identified that all strains belonged to T4 genotype. CONCLUSION: Amoebic keratitis is a sporadic parasitic keratitis, which is mainly seen in contact lens user in Mashhad. PCR based on 18S ribosomal DNA with JDP primers is a reliable and highly sensitive method for diagnosis of Acanthamoeba keratitis in clinically suspected cases.

18.
Eur J Ophthalmol ; 31(4): 1517-1524, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33124461

RESUMEN

OBJECTIVE: To evaluate changes in visual acuity and corneal tomographic outcomes at 6 months after femtosecond-laser assisted implantation of two different types of intracorneal implants in keratoconus. METHODS: A total of 39 keratoconus eyes implanted with two segments KeraRing (n = 22 eyes) or MyoRing (n = 17 eyes) were enrolled. Tomographic data (Pentacam system, Oculus) were analyzed and correlated with enhancement in uncorrected (UDVA) and corrected distance visual acuity (CDVA). The tomographic indices were front maximum keratometry (Kmax), corneal asphericity (Q-value) on both surfaces, average pachymetric progression indices (PPI), maximum Ambrosio relational thickness (ARTmax), Belin-Ambrósio enhanced ectasia total deviation index (BAD-D), index of surface variance (ISV), vertical asymmetry (IVA), height asymmetry (IHA) and height decentration (IHD). RESULTS: LogMAR UDVA and CDVA improved 2.1 (p = 0.003) and 0.7 (p = 0.074) lines with KeraRing, and 8 and 2.5 lines with MyoRing (p = 0.001). The highest and lowest mean differences in the tomographic indices between both groups were related to ISV and IHD, respectively. Changes in all indices differed significantly between two groups except for changes in front corneal astigmatism, ARTmax, ISV, IVA, IHD and IHA (p > 0.05). Correlation of changes in CDVA with changes in other parameters was statistically significant only for IHD in the KeraRing group, while changes in in UDVA were significantly correlated with changes in spherical equivalent, back Q-value, ISV, IVA, and IHA only in the MyoRing group. CONCLUSION: Both implants promote corneal shape regularization and an enhancement in UDVA in keratoconus. A considerable flattening effect and reduction in prolateness in the front corneal surface were observed with MyoRing.


Asunto(s)
Queratocono , Córnea/diagnóstico por imagen , Córnea/cirugía , Sustancia Propia/diagnóstico por imagen , Sustancia Propia/cirugía , Topografía de la Córnea , Humanos , Queratocono/cirugía , Prótesis e Implantes , Implantación de Prótesis , Refracción Ocular
19.
J Ophthalmol ; 2020: 4274037, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33083047

RESUMEN

PURPOSE: The biomechanical properties of ecstatic cornea undergo changes. This study evaluates the biomechanical changes of ecstatic cornea after implantation of two types of intracorneal stromal ring (ICR). METHODS: For doing this prospective cross-sectional study, 32 patients with keratoconus (KCN) were randomly divided into two 16-member groups (group I: MyoRing, group II: KeraRing). The main inclusion criteria were transparent cornea with no scar in the central part, corneal thickness >450 µ in the incision region, keratometry within 48-52 diopters, and progressive course of corneal thinning. Biomechanics of the cornea was evaluated by "ORA" and "Corvis" devices. All of the data were recorded and analyzed before implantation of the rings and 6 months thereafter. RESULTS: The mean ages of patients of groups I and II were 26 ± 6.55 and 33.86 ± 8.5, respectively. The postoperative change of sphere refraction was significant in both groups. However, reduction in the astigmatism was significant only in group I. In addition, the change of flat meridian keratometry (Kf) was significant before and after ring implantation in group I, unlike group II. The changes in CH and CRF parameters (ORA) were not significant in either group before and after the operation. Besides, only HRC parameter (Corvis) decreased significantly in both groups before and after the operation. CONCLUSION: Both MyoRing and KeraRings have positive effects on the biomechanics of cornea at least during the first year after implantation. Comparison of these two types of ICR did not show significant differences in Corvis and ORA parameters.

20.
Cornea ; 39(6): 761-768, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32195751

RESUMEN

PURPOSE: To investigate the changes in corneal backward scattering using Scheimpflug tomography (densitometry) 6 months after intrastromal corneal ring segments (Keraring) implant for keratoconus and to correlate with clinical results. METHODS: Along with standard ophthalmic examination, Scheimpflug tomography using Pentacam HR was performed to document corneal densitometry and corneal shape. A densitometry map was displayed using grayscale units (GSUs) ranging from 0 to 100 (minimum to maximum light scattering) in 4 concentric annuluses: central 2-, 2- to 6-, 6- to 10-, 10- to 12-, and total 12-mm corneal diameter and at 3 different depths: anterior 120 µm, posterior 60 µm, middle (varying accordingly to the total thickness), and total thickness. RESULTS: The changes in mean corneal densitometry values for anterior, central, and posterior layers were 3.82 ± 3.13, 2.70 ± 1.78, and 1.68 ± 1.52 GSU, respectively, and for annuluses of 0 to 2, 2 to 6, 6 to 10, and 10 to 12 mm were 2.96 ± 2.60, 4.53 ± 2.28, 2.09 ± 1.74, and 0.45 ± 3.93 GSU, respectively. The mean values increased for all corneal layers (P < 0.05), except in the peripheral 10- to 12-mm annulus (P> 0.05). The highest increase was in the annulus 2 to 6 mm of the anterior layer (5.72 ± 3.70 GSU). Changes in the mean densitometry showed a significant correlation with the mean of average keratometry changes only for the front corneal surface and changes in the Q-values for both corneal surfaces in the 2- to 6-mm annulus for all layers. CONCLUSIONS: Significant increase in the corneal densitometry mainly in the anterior 2- to 6-mm annulus of the cornea is associated with the position of the ring segment implant. More studies are needed to elucidate the relevance of such findings.


Asunto(s)
Córnea/diagnóstico por imagen , Densitometría/métodos , Queratocono/cirugía , Prótesis e Implantes , Implantación de Prótesis/métodos , Agudeza Visual , Adolescente , Adulto , Córnea/cirugía , Topografía de la Córnea/métodos , Femenino , Estudios de Seguimiento , Humanos , Queratocono/diagnóstico , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...