Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
IEEE Trans Biomed Eng ; 71(8): 2442-2453, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38466599

RESUMEN

OBJECTIVE: Finding events of interest is a common task in biomedical signal processing. The detection of epileptic seizures and signal artefacts are two key examples. Epoch-based classification is the typical machine learning framework to detect such signal events because of the straightforward application of classical machine learning techniques. Usually, post-processing is required to achieve good performance and enforce temporal dependencies. Designing the right post-processing scheme to convert these classification outputs into events is a tedious, and labor-intensive element of this framework. METHODS: We propose an event-based modeling framework that directly works with events as learning targets, stepping away from ad-hoc post-processing schemes to turn model outputs into events. We illustrate the practical power of this framework on simulated data and real-world data, comparing it to epoch-based modeling approaches. RESULTS: We show that event-based modeling (without tailored post-processing) performs on par with or better than epoch-based modeling with extensive post-processing. CONCLUSION: These results show the power of treating events as direct learning targets, instead of using ad-hoc post-processing to obtain them, severely reducing design effort. Significance The event-based modeling framework can easily be applied to other event detection problems in signal processing, removing the need for intensive task-specific post-processing.


Asunto(s)
Electroencefalografía , Procesamiento de Señales Asistido por Computador , Humanos , Electroencefalografía/métodos , Aprendizaje Automático , Algoritmos , Epilepsia/diagnóstico , Epilepsia/fisiopatología , Convulsiones/diagnóstico , Convulsiones/fisiopatología , Artefactos
3.
IEEE Trans Biomed Eng ; 69(2): 882-893, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34460362

RESUMEN

OBJECTIVE: Noise and disturbances hinder effective interpretation of recorded ECG. To identify the clean parts of a recording, free from such disturbances, various quality indicators have been developed. Previous instances of these indicators focus on human-defined desirable properties of a clean signal. The reliance on human-specified properties places an inherent limitation on the potential power of signal quality indicators. To move away from this limitation, we propose a data-driven quality indicator. METHODS: We use an unsupervised deep learning model, the auto-encoder, to derive the quality indicator. For different quality assessment settings we compare the performance of our quality indicator with traditional indicators. RESULTS: The data-driven method performs consistently strong across tasks while performance of the traditional indicators varies strongly from task to task. CONCLUSION: This strong performance indicates the potential of data-driven quality indicators for use in ECG processing, removing the reliance on expert-specified desirable properties. SIGNIFICANCE: The proposed methodology can easily be extended towards learning quality indicators in other data modalities.


Asunto(s)
Aprendizaje Profundo , Electrocardiografía , Algoritmos , Electrocardiografía/métodos , Humanos
4.
Sensors (Basel) ; 21(8)2021 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-33917824

RESUMEN

Impedance pneumography has been suggested as an ambulatory technique for the monitoring of respiratory diseases. However, its ambulatory nature makes the recordings more prone to noise sources. It is important that such noisy segments are identified and removed, since they could have a huge impact on the performance of data-driven decision support tools. In this study, we investigated the added value of machine learning algorithms to separate clean from noisy bio-impedance signals. We compared three approaches: a heuristic algorithm, a feature-based classification model (SVM) and a convolutional neural network (CNN). The dataset consists of 47 chronic obstructive pulmonary disease patients who performed an inspiratory threshold loading protocol. During this protocol, their respiration was recorded with a bio-impedance device and a spirometer, which served as a gold standard. Four annotators scored the signals for the presence of artefacts, based on the reference signal. We have shown that the accuracy of both machine learning approaches (SVM: 87.77 ± 2.64% and CNN: 87.20 ± 2.78%) is significantly higher, compared to the heuristic approach (84.69 ± 2.32%). Moreover, no significant differences could be observed between the two machine learning approaches. The feature-based and neural network model obtained a respective AUC of 92.77±2.95% and 92.51±1.74%. These findings show that a data-driven approach could be beneficial for the task of artefact detection in respiratory thoracic bio-impedance signals.


Asunto(s)
Artefactos , Máquina de Vectores de Soporte , Algoritmos , Impedancia Eléctrica , Humanos , Aprendizaje Automático , Redes Neurales de la Computación