Resultados 1 - 19 de 19
Filtrar
1.
EJNMMI Phys ; 11(1): 27, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38488989

RESUMEN

BACKGROUND: New digital detectors and block-sequential regularized expectation maximization (BSREM) reconstruction algorithm improve positron emission tomography (PET)/magnetic resonance (MR) image quality. The impact on image quality may differ from analogue PET/computed tomography (CT) protocol. The aim of this study is to determine the potential reduction of injected [68Ga]Ga-DOTA-TATE activity for digital PET/MR with BSREM reconstruction while maintaining at least equal image quality compared to the current analogue PET/CT protocol. METHODS: NEMA IQ phantom data and 25 patients scheduled for a diagnostic PET/MR were included. According to our current protocol, 1.5 MBq [68Ga]Ga-DOTA-TATE per kilogram (kg) was injected. After 60 min, scans were acquired with 3 (≤ 70 kg) or 4 (> 70 kg) minutes per bedposition. PET/MR scans were reconstructed using BSREM and factors ß 150, 300, 450 and 600. List mode data with reduced counts were reconstructed to simulate scans with 17%, 33%, 50% and 67% activity reduction. Image quality was measured quantitatively for PET/CT and PET/MR phantom and patient data. Experienced nuclear medicine physicians performed visual image quality scoring and lesion counting in the PET/MR patient data. RESULTS: Phantom analysis resulted in a possible injected activity reduction of 50% with factor ß = 600. Quantitative analysis of patient images revealed a possible injected activity reduction of 67% with factor ß = 600. Both with equal or improved image quality as compared to PET/CT. However, based on visual scoring a maximum activity reduction of 33% with factor ß = 450 was acceptable, which was further limited by lesion detectability analysis to an injected activity reduction of 17% with factor ß = 450. CONCLUSION: A digital [68Ga]Ga-DOTA-TATE PET/MR together with BSREM using factor ß = 450 result in 17% injected activity reduction with quantitative values at least similar to analogue PET/CT, without compromising on PET/MR visual image quality and lesion detectability.

2.
EBioMedicine ; 102: 105068, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38518652

RESUMEN

BACKGROUND: The aim of this study was to provide quantitative evidence for the potential of PSMA-targeting radioligand therapy (RLT) as treatment approach for malignant brain tumours, and to explore whether tumour uptake could be enhanced by super-selective intra-arterial (ssIA)-administration. METHODS: Ten patients (n = 5 high-grade glioma, n = 5 brain metastasis) received 1.5 MBq/kg [68Ga]Ga-PSMA-11 intravenously and, within 7 days, intra-arterially (i.e., selectively in tumour-feeding arteries), followed twice by PET-MRI at 90, 165 and 240 min post-injection. Patient safety was monitored for each procedure. Standardised uptake values (SUVs) were obtained for tumour, healthy-brain, salivary glands and liver. Tumour-to-salivary-gland (T/SG) and tumour-to-liver (T/L) uptake-ratios were calculated. FINDINGS: No adverse events requiring study termination occurred. All patients showed uptake of [68Ga]Ga-PSMA-11 at the tumour site. Uptake was a median 15-fold higher following ssIA-administration (SUVmax median: 142.8, IQR: 102.8-245.9) compared to IV-administration (10.5, IQR:7.5-13.0). According to the bootstrap analysis, mean SUVmax after ssIA (168.8, 95% CI: 110.6-227.0) was well beyond the 95% confidence-interval of IV administration (10.5, 95% CI: 8.4-12.7). Uptake in healthy-brain was negligible, independent of administration route (SUVmean <0.1-0.1). Off-target uptake was comparable, resulting in more favourable T/SG- and T/L-ratios of 8.4 (IQR: 4.4-11.5) and 26.5 (IQR: 14.0-46.4) following ssIA, versus 0.5 (IQR: 0.4-0.7) and 1.8 (IQR: 1.0-2.7) for IV-administration. INTERPRETATION: ssIA-administration is safe and leads to a median fifteen-fold higher radioligand uptake at the tumour site, therewith qualifying more patients for treatment and enhancing the potential of therapy. These results open new avenues for the development of effective RLT-based treatment strategies for patients with brain tumours. FUNDING: Semmy Foundation.


Asunto(s)
Neoplasias Encefálicas , Isótopos de Galio , Radioisótopos de Galio , Humanos , Encéfalo , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Estudios Prospectivos
3.
BMC Cancer ; 24(1): 146, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38287346

RESUMEN

BACKGROUND: Life expectancy of patients with metastatic castration-resistant prostate cancer (mCRPC) is still limited despite several systemic treatments. Within five years after diagnosis of primary prostate cancer, 10-20% of the patients have mCRPC and curation is not an option. Radionuclide therapy (RNT) targeted against prostate-specific membrane antigen (PSMA) emerged as a new treatment option and showed effective results in patients with mCRPC. Survival benefit after [177Lu]Lu-PSMA RNT has already been demonstrated in several clinical trials. However, [225Ac]Ac-PSMA (225Ac-PSMA) appears to be an even more promising radiopharmaceutical for the treatment of mCRPC. The use of alpha emitting radionuclides offers advantages over beta emitting radionuclides due to the high linear energy transfer effective for killing tumor cells and the limited range to reduce the radiation effects on the healthy tissue. However, these results are based on retrospective data and safety data of 225Ac-PSMA are still limited. Therefore, a prospective trial is needed to determine the optimal amount of activity that can be administered. METHODS: The 225Ac-PSMA-Imaging & Therapy (I&T) trial is an investigator-initiated phase I, single-center, open label, repeated dose-escalation and expansion trial. Patient with PSMA-positive mCRPC after at least one line of chemotherapy and/or one line of nonsteroidal antiandrogen will be treated with 225Ac-PSMA-I&T in increasing amount of activity per cycle. Dose-escalation following an accelerated 3 + 3 design which allows to open the next dose-level cohort in the absence of dose limiting toxicity while the previous one is still ongoing. Up to 4 treatment cohorts will be explored including up to 3 dose-escalation cohorts and one expansion cohort where patients will be administered with the recommended dose. A total of up to 30 patients will be enrolled in this trial. All patients will be evaluated for safety. Additionally, dosimetry was performed for the patients in the dose-escalation cohorts after the first 225Ac-PSMA-I&T administration. DISCUSSION: This trial will assess the safety and tolerability of 225Ac-PSMA-I&T in patients with mCRPC to recommend the optimal dose for the phase II trial. TRIAL REGISTRATION: ClinicalTrials.gov, (NCT05902247). Retrospectively registered 13 June 2023.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Masculino , Humanos , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Antígeno Prostático Específico , Estudios Prospectivos , Estudios Retrospectivos , Dipéptidos/efectos adversos , Radioisótopos/uso terapéutico , Radiofármacos/efectos adversos , Compuestos Heterocíclicos con 1 Anillo , Resultado del Tratamiento
4.
J Nucl Med ; 64(10): 1556-1562, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37536738

RESUMEN

CT and bone scintigraphy are not useful for response evaluation of bone metastases to 223Ra treatment in metastatic castration-resistant prostate cancer (mCRPC). PET using 68Ga prostate-specific membrane antigen 11 (68Ga-PSMA) is a promising tool for response evaluation of mCRPC. The aim of this study was to determine the utility of 68Ga-PSMA PET/CT for response evaluation of 223Ra treatment in patients with mCRPC. Methods: Within this prospective, multicenter, imaging discovery study, 28 patients with mCRPC, eligible for 223Ra treatment, were included between 2019 and 2022. Patients received 223Ra according to the standard of care. Study procedures included CT, bone scintigraphy, and 68Ga-PSMA PET/CT at baseline, after 3 and 6 cycles of 223Ra treatment, and on treatment failure. Response to 223Ra treatment was visually assessed on all 3 imaging modalities. Total tumor volume within bone (TTVbone) was determined on 68Ga-PSMA PET/CT. Intrapatient heterogeneity in response was studied using a newly developed image-registration tool for sequential images of PET/CT. Results were compared with failure-free survival (good responders vs. poor responders; cutoff, 24 wk) and alkaline phosphatase (ALP) response after 3 cycles. Results: Visual response assessment criteria could not distinguish good responders from poor responders on 68Ga-PSMA PET/CT and bone scintigraphy. For 68Ga-PSMA PET/CT, TTVbone at baseline was lower in good responders than in poor responders, whereas TTVbone increased in both groups during treatment. TTVbone was higher in patients with new extraosseous metastases during 223Ra treatment. Although TTVbone and ALP correlated at baseline, changes in TTVbone and ALP on treatment did not. 68Ga-PSMA response of TTVbone showed intrapatient heterogeneity in most patients. Conclusion: mCRPC patients with lower TTVbone on 68Ga-PSMA PET/CT have the best clinical outcome after 223Ra treatment. Response is highly heterogeneous in most patients. A decrease in ALP, which occurred in most patients, was not correlated with a decrease in TTVbone, which might make one question the value of ALP for disease monitoring during 223Ra treatment in clinical practice.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Neoplasias de la Próstata , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Estudios Prospectivos , Resultado del Tratamiento , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/terapia , Neoplasias de la Próstata/patología , Radioisótopos de Galio/uso terapéutico , Estudios Retrospectivos , Antígeno Prostático Específico
5.
Brain ; 146(1): 337-348, 2023 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-36374264

RESUMEN

Higher vascular disease burden increases the likelihood of developing dementia, including Alzheimer's disease. Better understanding the association between vascular risk factors and Alzheimer's disease pathology at the predementia stage is critical for developing effective strategies to delay cognitive decline. In this work, we estimated the impact of six vascular risk factors on the presence and severity of in vivo measured brain amyloid-beta (Aß) plaques in participants from the population-based Rotterdam Study. Vascular risk factors (hypertension, hypercholesterolaemia, diabetes, obesity, physical inactivity and smoking) were assessed 13 (2004-2008) and 7 years (2009-2014) prior to 18F-florbetaben PET (2018-2021) in 635 dementia-free participants. Vascular risk factors were associated with binary amyloid PET status or continuous PET readouts (standard uptake value ratios, SUVrs) using logistic and linear regression models, respectively, adjusted for age, sex, education, APOE4 risk allele count and time between vascular risk and PET assessment. Participants' mean age at time of amyloid PET was 69 years (range: 60-90), 325 (51.2%) were women and 190 (29.9%) carried at least one APOE4 risk allele. The adjusted prevalence estimates of an amyloid-positive PET status markedly increased with age [12.8% (95% CI 11.6; 14) in 60-69 years versus 35% (36; 40.8) in 80-89 years age groups] and APOE4 allele count [9.7% (8.8; 10.6) in non-carriers versus 38.4% (36; 40.8) to 60.4% (54; 66.8) in carriers of one or two risk allele(s)]. Diabetes 7 years prior to PET assessment was associated with a higher risk of a positive amyloid status [odds ratio (95% CI) = 3.68 (1.76; 7.61), P < 0.001] and higher standard uptake value ratios, indicating more severe Aß pathology [standardized beta = 0.40 (0.17; 0.64), P = 0.001]. Hypertension was associated with higher SUVr values in APOE4 carriers (mean SUVr difference of 0.09), but not in non-carriers (mean SUVr difference 0.02; P = 0.005). In contrast, hypercholesterolaemia was related to lower SUVr values in APOE4 carriers (mean SUVr difference -0.06), but not in non-carriers (mean SUVr difference 0.02). Obesity, physical inactivity and smoking were not related to amyloid PET measures. The current findings suggest a contribution of diabetes, hypertension and hypercholesterolaemia to the pathophysiology of Alzheimer's disease in a general population of older non-demented adults. As these conditions respond well to lifestyle modification and drug treatment, further research should focus on the preventative effect of early risk management on the development of Alzheimer's disease neuropathology.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Diabetes Mellitus , Hipercolesterolemia , Hipertensión , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/epidemiología , Enfermedad de Alzheimer/genética , Apolipoproteína E4/genética , Hipercolesterolemia/patología , Tomografía de Emisión de Positrones , Péptidos beta-Amiloides/metabolismo , Disfunción Cognitiva/patología , Encéfalo/patología , Diabetes Mellitus/epidemiología , Diabetes Mellitus/patología , Hipertensión/epidemiología , Hipertensión/patología , Obesidad/patología
7.
EJNMMI Res ; 11(1): 65, 2021 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-34279735

RESUMEN

BACKGROUND: The role of 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography/computed tomography (PET/CT) in children is still expanding. Dedicated paediatric dosage regimens are needed to keep the radiation dose as low as reasonably achievable and reduce the risk of radiation-induced carcinogenesis. The aim of this study is to investigate the relation between patient-dependent parameters and [18F]FDG PET image quality in order to propose a dedicated paediatric dose regimen. METHODS: In this retrospective analysis, 102 children and 85 adults were included that underwent a diagnostic [18F]FDG PET/CT scan. The image quality of the PET scans was measured by the signal-to-noise ratio (SNR) in the liver. The SNR liver was normalized (SNRnorm) for administered activity and acquisition time to apply curve fitting with body weight, body length, body mass index, body weight/body length and body surface area. Curve fitting was performed with two power fits, a nonlinear two-parameter model α p-d and a linear single-parameter model α p-0.5. The fit parameters of the preferred model were combined with a user preferred SNR to obtain at least moderate or good image quality for the dosage regimen proposal. RESULTS: Body weight demonstrated the highest coefficient of determination for the nonlinear (R2 = 0.81) and linear (R2 = 0.80) models. The nonlinear model was preferred by the Akaike's corrected information criterion. We decided to use a SNR of 6.5, based on the expert opinion of three nuclear medicine physicians. Comparison with the quadratic adult protocol confirmed the need for different dosage regimens for both patient groups. In this study, the amount of administered activity can be considerably reduced in comparison with the current paediatric guidelines. CONCLUSION: Body weight has the strongest relation with [18F]FDG PET image quality in children. The proposed nonlinear dosage regimen based on body mass will provide a constant and clinical sufficient image quality with a significant reduction of the effective dose compared to the current guidelines. A dedicated paediatric dosage regimen is necessary, as a universal dosing regimen for paediatric and adult is not feasible.

8.
Neurology ; 97(10): e1017-e1030, 2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-34210823

RESUMEN

OBJECTIVE: To assess the [18F]flortaucipir binding distribution across MAPT mutations in presymptomatic and symptomatic carriers. METHODS: We compared regional [18F]flortaucipir binding potential (BPND) derived from a 130-minute dynamic [18F]flortaucipir PET scan in 9 (pre)symptomatic MAPT mutation carriers (4 with P301L [1 symptomatic], 2 with R406W [1 symptomatic], 1 presymptomatic L315R, 1 presymptomatic S320F, and 1 symptomatic G272V carrier) with 30 cognitively normal controls and 52 patients with Alzheimer disease. RESULTS: [18F]Flortaucipir BPND images showed overall highest binding in the symptomatic carriers. This was most pronounced in the symptomatic R406W carrier in whom tau binding exceeded the normal control range in the anterior cingulate cortex, insula, amygdala, temporal, parietal, and frontal lobe. Elevated medial temporal lobe BPND was observed in a presymptomatic R406W carrier. The single symptomatic carrier and 1 of the 3 presymptomatic P301L carriers showed elevated [18F]flortaucipir BPND in the insula, parietal, and frontal lobe compared to controls. The symptomatic G272V carrier exhibited a widespread elevated cortical BPND, with at neuropathologic examination a combination of 3R pathology and encephalitis. The L315R presymptomatic mutation carrier showed higher frontal BPND compared to controls. The BPND values of the S320F presymptomatic mutation carrier fell within the range of controls. CONCLUSION: Presymptomatic MAPT mutation carriers already showed subtle elevated tau binding, whereas symptomatic MAPT mutation carriers showed a more marked increase in [18F]flortaucipir BPND. Tau deposition was most pronounced in R406W MAPT (pre)symptomatic mutation carriers, which is associated with both 3R and 4R tau accumulation. Thus, [18F]flortaucipir may serve as an early biomarker for MAPT mutation carriers in mutations that cause 3R/4R tauopathies.


Asunto(s)
Encéfalo/diagnóstico por imagen , Demencia Frontotemporal/diagnóstico por imagen , Neuroimagen/métodos , Tomografía de Emisión de Positrones/métodos , Proteínas tau/genética , Adulto , Anciano , Anciano de 80 o más Años , Carbolinas , Medios de Contraste , Diagnóstico Precoz , Femenino , Demencia Frontotemporal/genética , Heterocigoto , Humanos , Masculino , Persona de Mediana Edad , Mutación
9.
Pharmaceutics ; 13(5)2021 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-34068206

RESUMEN

Recently, promising results of the antitumor effects were observed in patients with metastatic castration-resistant prostate cancer treated with 177Lu-labeled PSMA-ligands. Radionuclide therapy efficacy may even be improved by using the alpha emitter Ac-225. Higher efficacy is claimed due to high linear energy transfer specifically towards PSMA positive cells, causing more double-strand breaks. This study aims to manufacture [225Ac]Ac-PSMA-I&T according to good manufacturing practice guidelines for the translation of [225Ac]Ac-PSMA-I&T into a clinical phase 1 dose escalation study. Quencher addition during labeling was investigated. Quality control of [225Ac]Ac-PSMA-I&T was based on measurement of Fr-221 (218 keV), in equilibrium with Ac-225 in approximately six half-lives of Fr-221 (T½ = 4.8 min). Radio-(i)TLC methods were utilized for identification of the different radiochemical forms, gamma counter for concentration determination, and HPGe-detector for the detection of the radiochemical yield. Radiochemical purity was determined by HPLC. The final patient dose was prepared and diluted with an optimized concentration of quenchers as during labeling, with an activity of 8-12 MBq (±5%), pH > 5.5, 100 ± 20 µg/dose, PSMA-I&T, radiochemical yield >95%, radiochemical purity >90% (up to 3 h), endotoxin levels of <5 EU/mL, osmolarity of 2100 mOsmol, and is produced according to current guidelines. The start of the phase I dose escalation study is planned in the near future.

10.
EJNMMI Phys ; 7(1): 69, 2020 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-33226485

RESUMEN

BACKGROUND: Personalized molecular radiotherapy based on theragnostics requires accurate quantification of the amount of radiopharmaceutical activity administered to patients both in diagnostic and therapeutic applications. This international multi-center study aims to investigate the clinical measurement accuracy of radionuclide calibrators for 7 radionuclides used in theragnostics: 99mTc, 111In, 123I, 124I, 131I, 177Lu, and 90Y. METHODS: In total, 32 radionuclide calibrators from 8 hospitals located in the Netherlands, Belgium, and Germany were tested. For each radionuclide, a set of four samples comprising two clinical containers (10-mL glass vial and 3-mL syringe) with two filling volumes were measured. The reference value of each sample was determined by two certified radioactivity calibration centers (SCK CEN and JRC) using two secondary standard ionization chambers. The deviation in measured activity with respect to the reference value was determined for each radionuclide and each measurement geometry. In addition, the combined systematic deviation of activity measurements in a theragnostic setting was evaluated for 5 clinically relevant theragnostic pairs: 131I/123I, 131I/124I, 177Lu/111In, 90Y/99mTc, and 90Y/111In. RESULTS: For 99mTc, 131I, and 177Lu, a small minority of measurements were not within ± 5% range from the reference activity (percentage of measurements not within range: 99mTc, 6%; 131I, 14%; 177Lu, 24%) and almost none were outside ± 10% range. However, for 111In, 123I, 124I, and 90Y, more than half of all measurements were not accurate within ± 5% range (111In, 51%; 123I, 83%; 124I, 63%; 90Y, 61%) and not all were within ± 10% margin (111In, 22%; 123I, 35%; 124I, 15%; 90Y, 25%). A large variability in measurement accuracy was observed between radionuclide calibrator systems, type of sample container (vial vs syringe), and source-geometry calibration/correction settings used. Consequently, we observed large combined deviations (percentage deviation > ± 10%) for the investigated theragnostic pairs, in particular for 90Y/111In, 131I/123I, and 90Y/99mTc. CONCLUSIONS: Our study shows that substantial over- or underestimation of therapeutic patient doses is likely to occur in a theragnostic setting due to errors in the assessment of radioactivity with radionuclide calibrators. These findings underline the importance of thorough validation of radionuclide calibrator systems for each clinically relevant radionuclide and sample geometry.

11.
EJNMMI Res ; 10(1): 27, 2020 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-32201912

RESUMEN

BACKGROUND: Positron emission tomography (PET) imaging with 68Gallium labeled somatostatin analogues (68Ga-DOTA-SSA) plays a key role in neuroendocrine tumor management. The impact of patient size on PET image quality is not well known for PET imaging with 68Ga-DOTA-SSA. The aim of this study is to propose a dose regimen based on patient size that optimizes image quality and yields sufficient image quality for diagnosis. METHODS: Twenty-one patients (12 males, 9 females) were prospectively included for 68Gallium-DOTA-Tyr3-Octreotate (68Ga-DOTA-TATE) PET/CT, which was acquired in whole body list mode using 6 min per bed position (mbp). The list-mode events were randomly sampled to obtain 1 to 6 mbp PET reconstructions. For semi-quantitative assessment of image quality, the signal-to-noise ratio (SNR) was measured in the liver. The SNR normalized (SNRnorm) for administered activity and mbp was correlated with body mass, length, body mass index, body mass/length, and lean body mass. Three experienced nuclear medicine physicians visually graded image quality using a 4-point scale, and categorically scored the number of somatostatin-receptor positive lesions for each reconstruction. To investigate the impact of image quality on lesion quantification, the mean, maximum, and peak standardized uptake values (SUVs) of one abdominal lesion were measured in the 1 to 6 mbp PET reconstructions. RESULTS: Of all patient-dependent parameters, body mass showed the strongest correlation (R2 = 0.6) with SNRnorm. Lesion detectability analysis showed no significant difference for 3-5 mbp compared with the complete 6 mbp PET reconstruction. The SUV measurements showed no significant (p > 0.05) differences across the reconstructions. Visual assessment revealed that an SNR of 6.2 results in PET scans with moderate to good image quality. A non-linear expression was derived to calculate the required (dose × acquisition time) product (DTP) for the chosen SNR level of 6.2 that would yield a more constant image quality. CONCLUSION: Body mass can be used to predict 68Ga-DOTA-TATE PET image quality. The proposed non-linear dose regimen based on body mass standardizes the image quality while maintaining sufficient image quality for diagnosis.

12.
J Nucl Med ; 61(11): 1607-1614, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32169916

RESUMEN

For individual treatment decisions in patients with metastatic prostate cancer (mPC), molecular diagnostics are increasingly used. Bone metastases are frequently the only source for obtaining metastatic tumor tissue. However, the success rate of CT-guided bone biopsies for molecular analyses in mPC patients is approximately only 40%. PET using 68Ga prostate-specific membrane antigen (68Ga-PSMA) is a promising tool to improve the harvest rate of bone biopsies for molecular analyses. The aim of this study was to determine the success rate of 68Ga-PSMA-guided bone biopsies for molecular diagnostics in mPC patients. Methods: Within a prospective multicenter whole-genome sequencing trial (NCT01855477), 69 mPC patients underwent 68Ga-PSMA PET/CT before bone biopsy. The primary endpoint was the success rate (tumor percentage ≥ 30%) of 68Ga-PSMA-guided bone biopsies. At biopsy sites, 68Ga-PSMA uptake was quantified using rigid-body image registration of 68Ga-PSMA PET/CT and interventional CT. Actionable somatic alterations were identified. Results: The success rate of 68Ga-PSMA-guided biopsies for molecular analyses was 70%. At biopsy sites categorized as positive, inconclusive, or negative for 68Ga-PSMA uptake, 70%, 64%, and 36% of biopsies were tumor-positive (≥30%), respectively (P = 0.0610). In tumor-positive biopsies, 68Ga-PSMA uptake was significantly higher (P = 0.008), whereas radiodensity was significantly lower (P = 0.006). With an area under the curve of 0.84 and 0.70, both 68Ga-PSMA uptake (SUVmax) and radiodensity (mean Hounsfield units) were strong predictors for a positive biopsy. Actionable somatic alterations were detected in 73% of the sequenced biopsies. Conclusion: In patients with mPC, 68Ga-PSMA PET/CT improves the success rate of CT-guided bone biopsies for molecular analyses, thereby identifying actionable somatic alterations in more patients. Therefore, 68Ga-PSMA PET/CT may be considered for guidance of bone biopsies in both clinical practice and clinical trials.


Asunto(s)
Neoplasias Óseas/secundario , Huesos/patología , Ácido Edético/análogos & derivados , Biopsia Guiada por Imagen/métodos , Oligopéptidos/farmacocinética , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Radiofármacos/farmacocinética , Anciano , Neoplasias Óseas/patología , Ácido Edético/farmacocinética , Isótopos de Galio , Radioisótopos de Galio , Humanos , Masculino , Persona de Mediana Edad , Técnicas de Diagnóstico Molecular , Estudios Prospectivos
13.
EJNMMI Phys ; 7(1): 9, 2020 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-32048097

RESUMEN

BACKGROUND: Quantitative SPECT imaging in targeted radionuclide therapy with lutetium-177 holds great potential for individualized treatment based on dose assessment. The establishment of dose-effect relations requires a standardized method for SPECT quantification. The purpose of this multi-center study is to evaluate quantitative accuracy and inter-system variations of different SPECT/CT systems with corresponding commercially available quantitative reconstruction algorithms. This is an important step towards a vendor-independent standard for quantitative lutetium-177 SPECT. METHODS: Four state-of-the-art SPECT/CT systems were included: Discovery™ NM/CT 670Pro (GE Healthcare), Symbia Intevo™, and two Symbia™ T16 (Siemens Healthineers). Quantitative accuracy and inter-system variations were evaluated by repeatedly scanning a cylindrical phantom with 6 spherical inserts (0.5 - 113 ml). A sphere-to-background activity concentration ratio of 10:1 was used. Acquisition settings were standardized: medium energy collimator, body contour trajectory, photon energy window of 208 keV (± 10%), adjacent 20% lower scatter window, 2 × 64 projections, 128 × 128 matrix size, and 40 s projection time. Reconstructions were performed using GE Evolution with Q.Metrix™, Siemens xSPECT Quant™, Siemens Broad Quantification™ or Siemens Flash3D™ algorithms using vendor recommended settings. In addition, projection data were reconstructed using Hermes SUV SPECT™ with standardized reconstruction settings to obtain a vendor-neutral quantitative reconstruction for all systems. Volumes of interest (VOI) for the spheres were obtained by applying a 50% threshold of the sphere maximum voxel value corrected for background activity. For each sphere, the mean and maximum recovery coefficient (RCmean and RCmax) of three repeated measurements was calculated, defined as the imaged activity concentration divided by the actual activity concentration. Inter-system variations were defined as the range of RC over all systems. RESULTS: RC decreased with decreasing sphere volume. Inter-system variations with vendor-specific reconstructions were between 0.06 and 0.41 for RCmean depending on sphere size (maximum 118% quantification difference), and improved to 0.02-0.19 with vendor-neutral reconstructions (maximum 38% quantification difference). CONCLUSION: This study shows that eliminating sources of possible variation drastically reduces inter-system variation in quantification. This means that absolute SPECT quantification for 177Lu is feasible in a multi-center and multi-vendor setting; however, close agreement between vendors and sites is key for multi-center dosimetry and quantitative biomarker studies.

14.
EJNMMI Phys ; 6(1): 29, 2019 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-31879813

RESUMEN

Absolute quantification of radiotracer distribution using SPECT/CT imaging is of great importance for dosimetry aimed at personalized radionuclide precision treatment. However, its accuracy depends on many factors. Using phantom measurements, this multi-vendor and multi-center study evaluates the quantitative accuracy and inter-system variability of various SPECT/CT systems as well as the effect of patient size, processing software and reconstruction algorithms on recovery coefficients (RC). METHODS: Five SPECT/CT systems were included: Discovery™ NM/CT 670 Pro (GE Healthcare), Precedence™ 6 (Philips Healthcare), Symbia Intevo™, and Symbia™ T16 (twice) (Siemens Healthineers). Three phantoms were used based on the NEMA IEC body phantom without lung insert simulating body mass indexes (BMI) of 25, 28, and 47 kg/m2. Six spheres (0.5-26.5 mL) and background were filled with 0.1 and 0.01 MBq/mL 99mTc-pertechnetate, respectively. Volumes of interest (VOI) of spheres were obtained by a region growing technique using a 50% threshold of the maximum voxel value corrected for background activity. RC, defined as imaged activity concentration divided by actual activity concentration, were determined for maximum (RCmax) and mean voxel value (RCmean) in the VOI for each sphere diameter. Inter-system variability was expressed as median absolute deviation (MAD) of RC. Acquisition settings were standardized. Images were reconstructed using vendor-specific 3D iterative reconstruction algorithms with institute-specific settings used in clinical practice and processed using a standardized, in-house developed processing tool based on the SimpleITK framework. Additionally, all data were reconstructed with a vendor-neutral reconstruction algorithm (Hybrid Recon™; Hermes Medical Solutions). RESULTS: RC decreased with decreasing sphere diameter for each system. Inter-system variability (MAD) was 16 and 17% for RCmean and RCmax, respectively. Standardized reconstruction decreased this variability to 4 and 5%. High BMI hampers quantification of small lesions (< 10 ml). CONCLUSION: Absolute SPECT quantification in a multi-center and multi-vendor setting is feasible, especially when reconstruction protocols are standardized, paving the way for a standard for absolute quantitative SPECT.

15.
EJNMMI Phys ; 5(1): 17, 2018 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-30069805

RESUMEN

BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 (177Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources-they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. RESULTS: The volumes reported by the participants for the inner section of the source were all within 29% of the true value and within 60% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20% of the true value, whilst those reported for the outer section were up to 83% different to the true value. CONCLUSIONS: A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods.

16.
Mol Imaging Biol ; 20(6): 973-983, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29556947

RESUMEN

PURPOSE: The gastrin-releasing peptide receptor (GRPR), overexpressed on various tumor types, is an attractive target for receptor-mediated imaging and therapy. Another interesting approach would be the use of GRPR radioligands for pre-operative imaging and subsequent radio-guided surgery, with the goal to improve surgical outcome. GRPR radioligands were successfully implemented in clinical studies, especially Sarabesin 3 (SB3) is an appealing GRPR antagonist with high receptor affinity. Gallium-68 labeled SB3 has good in vivo stability, after labeling with Indium-111; however, the molecule shows poor in vivo stability, which negatively impacts tumor-targeting capacity. A novel approach to increase in vivo stability of radiopeptides is by co-administration of the neutral endopeptidase (NEP) inhibitor, phosphoramidon (PA). We studied in vivo stability and biodistribution of [111In]SB3 without/with (-/+) PA in mice. Furthermore, SPECT/MRI on a novel, state-of-the-art platform was performed. PROCEDURES: GRPR affinity of SB3 was determined on PC295 xenograft sections using [125I]Tyr4-bombesin with tracer only or with increasing concentrations of SB3. For in vivo stability, mice were injected with 200/2000 pmol [111In]SB3 -/+ 300 µg PA. Blood was collected and analyzed. Biodistribution and SPECT/MRI studies were performed at 1, 4, and 24 h postinjection (p.i.) of 2.5 MBq/200 pmol or 25 MBq/200 pmol [111In]SB3 -/+ 300 µg PA in PC-3-xenografted mice. RESULTS: SB3 showed high affinity for GRPR (IC50 3.5 nM). Co-administration of PA resulted in twice higher intact peptide in vivo vs [111In]SB3 alone. Biodistribution studies at 1, 4, and 24 h p.i. show higher tumor uptake values with PA co-administration (19.7 ± 3.5 vs 10.2 ± 1.5, 17.6 ± 5.1 vs 8.3 ± 1.1, 6.5 ± 3.3 vs 3.1 ± 1.9 % ID/g tissue (P < 0.0001)). Tumor imaging with SPECT/MRI clearly improved after co-injection of PA. CONCLUSIONS: Co-administration of PA increased in vivo tumor targeting capacity of [111In]SB3, making this an attractive combination for GRPR-targeted tumor imaging.


Asunto(s)
Diagnóstico por Imagen/métodos , Cuidados Intraoperatorios/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Receptores de Bombesina/antagonistas & inhibidores , Animales , Unión Competitiva , Endocitosis , Imagen por Resonancia Magnética , Masculino , Ratones Endogámicos BALB C , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único
17.
Eur J Nucl Med Mol Imaging ; 42(4): 579-96, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25673052

RESUMEN

In view of the trend towards personalized treatment strategies for (cancer) patients, there is an increasing need to noninvasively determine individual patient characteristics. Such information enables physicians to administer to patients accurate therapy with appropriate timing. For the noninvasive visualization of disease-related features, imaging biomarkers are expected to play a crucial role. Next to the chemical development of imaging probes, this requires preclinical studies in animal tumour models. These studies provide proof-of-concept of imaging biomarkers and help determine the pharmacokinetics and target specificity of relevant imaging probes, features that provide the fundamentals for translation to the clinic. In this review we describe biological processes derived from the "hallmarks of cancer" that may serve as imaging biomarkers for diagnostic, prognostic and treatment response monitoring that are currently being studied in the preclinical setting. A number of these biomarkers are also being used for the initial preclinical assessment of new intervention strategies. Uniquely, noninvasive imaging approaches allow longitudinal assessment of changes in biological processes, providing information on the safety, pharmacokinetic profiles and target specificity of new drugs, and on the antitumour effectiveness of therapeutic interventions. Preclinical biomarker imaging can help guide translation to optimize clinical biomarker imaging and personalize (combination) therapies.


Asunto(s)
Biomarcadores de Tumor/metabolismo , Diagnóstico por Imagen , Neoplasias/diagnóstico , Animales , Neoplasias/diagnóstico por imagen , Radiografía , Cintigrafía , Radiofármacos/farmacocinética
18.
Curr Alzheimer Res ; 11(8): 725-32, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25212911

RESUMEN

PURPOSE: [(18)F]fluorodeoxyglucose (FDG) PET imaging of the brain can be used to assist in the differential diagnosis of dementia. Group differences in glucose uptake between patients with dementia and controls are well-known. However, a multivariate analysis technique called scaled subprofile model, principal component analysis (SSM/PCA) aiming at identifying diagnostic neural networks in diseases, have been applied less frequently. We validated an Alzheimer's Disease-related (AD) glucose metabolic brain pattern using the SSM/PCA analysis and applied it prospectively in an independent confirmation cohort. METHODS: We used FDG-PET scans of 18 healthy controls and 15 AD patients (identification cohort) to identify an AD-related glucose metabolic covariance pattern. In the confirmation cohort (n=15), we investigated the ability to discriminate between probable AD and non-probable AD (possible AD, mild cognitive impairment (MCI) or subjective complaints). RESULTS: The AD-related metabolic covariance pattern was characterized by relatively decreased metabolism in the temporoparietal regions and relatively increased metabolism in the subcortical white matter, cerebellum and sensorimotor cortex. Receiver-operating characteristic (ROC) curves showed at a cut-off value of z=1.23, a sensitivity of 93% and a specificity of 94% for correct AD classification. In the confirmation cohort, subjects with clinically probable AD diagnosis showed a high expression of the AD-related pattern whereas in subjects with a non-probable AD diagnosis a low expression was found. CONCLUSION: The Alzheimer's disease-related cerebral glucose metabolic covariance pattern identified by SSM/PCA analysis was highly sensitive and specific for Alzheimer's disease. This method is expected to be helpful in the early diagnosis of Alzheimer's disease in clinical practice.


Asunto(s)
Enfermedad de Alzheimer/patología , Encéfalo/metabolismo , Glucosa/metabolismo , Anciano , Enfermedad de Alzheimer/complicaciones , Enfermedad de Alzheimer/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Trastornos del Conocimiento/diagnóstico , Trastornos del Conocimiento/etiología , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Tomografía de Emisión de Positrones
19.
Magn Reson Med ; 64(2): 546-53, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20665798

RESUMEN

A method to reduce the acoustic noise generated by gradient systems in MRI has been recently proposed; such a method is based on the linear response theory. Since the physical cause of MRI acoustic noise is the time derivative of the gradient current, a common trapezoid current shape produces an acoustic gradient coil response mainly during the rising and falling edge. In the falling edge, the coil acoustic response presents a 180 degrees phase difference compared to the rising edge. Therefore, by varying the width of the trapezoid and keeping the ramps constant, it is possible to suppress one selected frequency and its higher harmonics. This value is matched to one of the prominent resonance frequencies of the gradient coil system. The idea of cancelling a single frequency is extended to a second frequency, using two successive trapezoid-shaped pulses presented at a selected interval. Overall sound pressure level reduction of 6 and 10 dB is found for the two trapezoid shapes and a single pulse shape, respectively. The acoustically optimized pulse shape proposed is additionally tested in a simulated echo planar imaging readout train, obtaining a sound pressure level reduction of 12 dB for the best case.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Ruido , Espectrografía del Sonido/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...