1.
Radiography (Lond) ; 27(1): 136-141, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32727709

RESUMEN

INTRODUCTION: The protocol for preparation of computed tomography urography (CTU) examinations at our hospital was changed in 2013 to improve the quality of urinary bladder filling in the excretory phase. The aim of this study was to evaluate the quality of urinary bladder filling on CTU after different doses of furosemide were administered to patients with macroscopic hematuria. METHODS: The cohort was 215 patients who underwent elective CTU due to macroscopic hematuria between 2014 and 2018. 5 mg furosemide were administrated to 100 patients, 2.5 mg to 100 patients and 0 mg to 15 patients. Contrast medium layered bladders were excluded, leaving 193 patients: 92, 89 and 12 in each group. Urinary bladder volume was calculated in corticomedullary (CMP) and excretory phase (EP). Bladder distension was classified as satisfactory or not. Attenuation of bladder content in EP was noted. RESULTS: Average volume in EP was 370 ± 224 ml (28-1052) after 5 mg furosemide, 274 ± 120 ml (43-628) after 2.5 mg and 180 ± 104 ml (53-351) after 0 mg. 85% of the bladders were satisfactory distended after 5 mg, 80% after 2.5 mg and 58% after 0 mg. Average attenuation was 266 ± 89 HU (103-524) after 5 mg, 362 ± 156 HU (118-948) after 2.5 mg and 761 ± 331 HU (347-1206) after 0 mg. The differences in volume and attenuation were significant. CONCLUSION: 5 mg furosemide is preferred rather than 2.5 mg in preparation for CTU examinations of patients with macroscopic hematuria. There was no difference between the doses concerning rate of satisfactory bladder distension, but the higher dose resulted in larger bladder volume and more suitable attenuation of bladder content. IMPLICATIONS FOR PRACTICE: Development of CTU-image quality could improve bladder cancer diagnostics.


Asunto(s)
Furosemida , Vejiga Urinaria , Hematuria/diagnóstico por imagen , Humanos , Tomografía Computarizada por Rayos X , Vejiga Urinaria/diagnóstico por imagen , Urografía
2.
Acta Radiol ; 50(4): 446-54, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19308762

RESUMEN

BACKGROUND: Since computed tomography (CT) urography began to replace excretory urography as the primary imaging technique in uroradiology, the collective radiation dose to the patients has increased. PURPOSE: To examine the changes in the CT urography protocol for investigating suspected urinary tract malignancy between the years 1997 and 2008, and how these changes have influenced the mean effective dose. MATERIAL AND METHODS: The study was based on 102 patients (mean age 66.1+/-14.8 years, range 31-89 years; 30 female, 72 male) divided into five groups (groups A-E) corresponding to the time points at which changes were made to the CT urography protocol. The mean effective doses were estimated using the ImPACT CT Patient Dosimetry Calculator. RESULTS: The number of scan phases at CT urography was reduced from four to three in 1999, resulting in a reduction of the mean effective dose from 29.9/22.5 (female [F]/male [M]) mSv (group A) to 26.1/18.9 (F/M) mSv (group B). In 2001, mAs settings were adapted to patient size, and the mean effective dose was reduced to 16.8/12.0 (F/M) mSv (group C). In 2005, scans were performed with a multidetector-row CT equipped with automatic tube current modulation in the x- and y-axis (CARE Dose). The effective mAs was also lowered in the unenhanced and excretory phase, yet the mean effective dose increased to 18.2/13.1 (F/M) mSv (group D), since the effective mAs had to be increased in the corticomedullary phase to maintain image quality. In 2008, as tube current modulation in the x-, y-, and z-axis was introduced (CARE Dose4D), the mean effective dose was reduced to 11.7/8.8 (F/M) mSv (group E). CONCLUSION: This study shows that the individual mean effective dose to patients undergoing CT urography has decreased by 60%, from 29.9/22.5 (F/M) mSv in 1997 to 11.7/8.8 (F/M) mSv in 2008.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X , Urografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Urológicas/diagnóstico por imagen