Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Biomedicines ; 12(8)2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39200092

RESUMEN

Psoriasis induces systemic atherosclerosis, but its impact on cerebrovascular function remains unclear. However, stroke prevention must be considered in psoriasis, as it is commonly comorbid with classic cardiovascular risk factors. Thus, the aim of the study is to assess cerebral microvasculature function and its confounders in patients with psoriasis. The study protocol included cerebral autoregulation assessment with measurements of vasomotor reactivity reserve (VMRr) on the middle cerebral arteries with the use of a Transcranial Doppler (TCD) in 50 patients with psoriasis without cerebrovascular events (46; 21-74 years) and 26 healthy controls (41; 29-58 years). Analyses of VMRr relationships with the psoriasis course, comorbidities, inflammatory markers and intima-media thickness (IMT) were performed. The study showed that VMRr was lower (64% vs. 76%, p = 0.001), and the IMT was higher (0.65 vs. 0.52 mm, p = 0.001) in patients compared to controls. The patients were also characterized by a higher body mass index (BMI) and a higher level of Il-6 than the controls (29.14 vs. 25.76 kg/m2, p = 0.004 and 585 vs. 204 pg/mL, p < 0.001, respectively), but only BMI was independently impacting VMRr reduction (p = 0.02). In conclusion, early cerebral microvasculature dysfunction may occur in patients with psoriasis, and its extent is associated with an increase in BMI. Thus, body mass reduction should be strongly recommended for stroke prophylaxis in patients with psoriasis.

2.
J Clin Med ; 13(14)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-39064087

RESUMEN

Background/Objectives: To systematically review and summarize the existing scientific evidence on the diagnostic performance of artificial intelligence (AI) in assessing cervical vertebral maturation (CVM). This review aimed to evaluate the accuracy and reliability of AI algorithms in comparison to those of experienced clinicians. Methods: Comprehensive searches were conducted across multiple databases, including PubMed, Scopus, Web of Science, and Embase, using a combination of Boolean operators and MeSH terms. The inclusion criteria were cross-sectional studies with neural network research, reporting diagnostic accuracy, and involving human subjects. Data extraction and quality assessment were performed independently by two reviewers, with a third reviewer resolving any disagreements. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool was used for bias assessment. Results: Eighteen studies met the inclusion criteria, predominantly employing supervised learning techniques, especially convolutional neural networks (CNNs). The diagnostic accuracy of AI models for CVM assessment varied widely, ranging from 57% to 95%. The factors influencing accuracy included the type of AI model, training data, and study methods. Geographic concentration and variability in the experience of radiograph readers also impacted the results. Conclusions: AI has considerable potential for enhancing the accuracy and reliability of CVM assessments in orthodontics. However, the variability in AI performance and the limited number of high-quality studies suggest the need for further research.

3.
J Clin Med ; 13(14)2024 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-39064157

RESUMEN

Background/Objectives: The aim of this study was to assess the diagnostic accuracy of the AI-driven platform Diagnocat for evaluating endodontic treatment outcomes using cone beam computed tomography (CBCT) images. Methods: A total of 55 consecutive patients (15 males and 40 females, aged 12-70 years) referred for CBCT imaging were included. CBCT images were analyzed using Diagnocat's AI platform, which assessed parameters such as the probability of filling, adequate obturation, adequate density, overfilling, voids in filling, short filling, and root canal number. The images were also evaluated by two experienced human readers. Diagnostic accuracy metrics (accuracy, precision, recall, and F1 score) were assessed and compared to the readers' consensus, which served as the reference standard. Results: The AI platform demonstrated high diagnostic accuracy for most parameters, with perfect scores for the probability of filling (accuracy, precision, recall, F1 = 100%). Adequate obturation showed moderate performance (accuracy = 84.1%, precision = 66.7%, recall = 92.3%, and F1 = 77.4%). Adequate density (accuracy = 95.5%, precision, recall, and F1 = 97.2%), overfilling (accuracy = 95.5%, precision = 86.7%, recall = 100%, and F1 = 92.9%), and short fillings (accuracy = 95.5%, precision = 100%, recall = 86.7%, and F1 = 92.9%) also exhibited strong performance. The performance of AI for voids in filling detection (accuracy = 88.6%, precision = 88.9%, recall = 66.7%, and F1 = 76.2%) highlighted areas for improvement. Conclusions: The AI platform Diagnocat showed high diagnostic accuracy in evaluating endodontic treatment outcomes using CBCT images, indicating its potential as a valuable tool in dental radiology.

4.
J Clin Med ; 13(13)2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38999299

RESUMEN

Background: Cephalometric analysis (CA) is an indispensable diagnostic tool in orthodontics for treatment planning and outcome assessment. Manual CA is time-consuming and prone to variability. Methods: This study aims to compare the accuracy and repeatability of CA results among three commercial AI-driven programs: CephX, WebCeph, and AudaxCeph. This study involved a retrospective analysis of lateral cephalograms from a single orthodontic center. Automated CA was performed using the AI programs, focusing on common parameters defined by Downs, Ricketts, and Steiner. Repeatability was tested through 50 randomly reanalyzed cases by each software. Statistical analyses included intraclass correlation coefficients (ICC3) for agreement and the Friedman test for concordance. Results: One hundred twenty-four cephalograms were analyzed. High agreement between the AI systems was noted for most parameters (ICC3 > 0.9). Notable differences were found in the measurements of angle convexity and the occlusal plane, where discrepancies suggested different methodologies among the programs. Some analyses presented high variability in the results, indicating errors. Repeatability analysis revealed perfect agreement within each program. Conclusions: AI-driven cephalometric analysis tools demonstrate a high potential for reliable and efficient orthodontic assessments, with substantial agreement in repeated analyses. Despite this, the observed discrepancies and high variability in part of analyses underscore the need for standardization across AI platforms and the critical evaluation of automated results by clinicians, particularly in parameters with significant treatment implications.

5.
Diagnostics (Basel) ; 14(12)2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38928639

RESUMEN

The field of computed tomography (CT), which is a basic diagnostic tool in clinical practice, has recently undergone rapid technological advances. These include the evolution of dual-energy CT (DECT) and development of photon-counting computed tomography (PCCT). DECT enables the acquisition of CT images at two different energy spectra, which allows for the differentiation of certain materials, mainly calcium and iodine. PCCT is a recent technology that enables a scanner to quantify the energy of each photon gathered by the detector. This method gives the possibility to decrease the radiation dose and increase the spatial and temporal resolutions of scans. Both of these techniques have found a wide range of applications in radiology, including vascular studies. In this narrative review, the authors present the principles of DECT and PCCT, outline their advantages and drawbacks, and briefly discuss the application of these methods in vascular radiology.

6.
Diagnostics (Basel) ; 14(12)2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38928694

RESUMEN

OBJECTIVE: This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. MATERIALS AND METHODS: This retrospective study included 70 patients, 61 of whom were analyzed after excluding those with severe motion artifacts. CBCT scans, performed using a Hyperion X9 PRO 13 × 10 CBCT machine, included images with dental implants, amalgam fillings, orthodontic appliances, root canal fillings, and crowns. Images were processed with the ClariCT.AI deep learning model (DLM) for noise reduction. Objective image quality was assessed using metrics such as the differentiation between voxel values (ΔVVs), the artifact index (AIx), and the contrast-to-noise ratio (CNR). Subjective assessments were performed by two experienced readers, who rated overall image quality and artifact intensity on predefined scales. RESULTS: Compared with native images, DLM reconstructions significantly reduced the AIx and increased the CNR (p < 0.001), indicating improved image clarity and artifact reduction. Subjective assessments also favored DLM images, with higher ratings for overall image quality and lower artifact intensity (p < 0.001). However, the ΔVV values were similar between the native and DLM images, indicating that while the DLM reduced noise, it maintained the overall density distribution. Orthodontic appliances produced the most pronounced artifacts, while implants generated the least. CONCLUSIONS: AI-based noise reduction using ClariCT.AI significantly enhances CBCT image quality by reducing noise and metal artifacts, thereby improving diagnostic accuracy and treatment planning. Further research with larger, multicenter cohorts is recommended to validate these findings.

7.
J Clin Med ; 13(12)2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38929931

RESUMEN

Background/Objectives: The purpose of this preliminary study was to evaluate the diagnostic performance of an AI-driven platform, Diagnocat (Diagnocat Ltd., San Francisco, CA, USA), for assessing endodontic treatment outcomes using panoramic radiographs (PANs). Materials and Methods: The study included 55 PAN images of 55 patients (15 males and 40 females, aged 12-70) who underwent imaging at a private dental center. All images were acquired using a Hyperion X9 PRO digital cephalometer and were evaluated using Diagnocat, a cloud-based AI platform. The AI system assessed the following endodontic treatment features: filling probability, obturation adequacy, density, overfilling, voids in filling, and short filling. Two human observers independently evaluated the images, and their consensus served as the reference standard. The diagnostic accuracy metrics were calculated. Results: The AI system demonstrated high accuracy (90.72%) and a strong F1 score (95.12%) in detecting the probability of endodontic filling. However, the system showed variable performance in other categories, with lower accuracy metrics and unacceptable F1 scores for short filling and voids in filling assessments (8.33% and 14.29%, respectively). The accuracy for detecting adequate obturation and density was 55.81% and 62.79%, respectively. Conclusions: The AI-based system showed very high accuracy in identifying endodontically treated teeth but exhibited variable diagnostic accuracy for other qualitative features of endodontic treatment.

8.
J Clin Med ; 13(12)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38930132

RESUMEN

Background: This study evaluates the diagnostic accuracy of an AI-assisted tool in assessing the proximity of the mandibular canal (MC) to the root apices (RAs) of mandibular teeth using computed tomography (CT). Methods: This study involved 57 patients aged 18-30 whose CT scans were analyzed by both AI and human experts. The primary aim was to measure the closest distance between the MC and RAs and to assess the AI tool's diagnostic performance. The results indicated significant variability in RA-MC distances, with third molars showing the smallest mean distances and first molars the greatest. Diagnostic accuracy metrics for the AI tool were assessed at three thresholds (0 mm, 0.5 mm, and 1 mm). Results: The AI demonstrated high specificity but generally low diagnostic accuracy, with the highest metrics at the 0.5 mm threshold with 40.91% sensitivity and 97.06% specificity. Conclusions: This study underscores the limited potential of tested AI programs in reducing iatrogenic damage to the inferior alveolar nerve (IAN) during dental procedures. Significant differences in RA-MC distances between evaluated teeth were found.

9.
Magn Reson Imaging ; 112: 63-81, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38914147

RESUMEN

This review examines the advancements in magnetic resonance imaging (MRI) techniques and their pivotal role in diagnosing and managing gliomas, the most prevalent primary brain tumors. The paper underscores the importance of integrating modern MRI modalities, such as diffusion-weighted imaging and perfusion MRI, which are essential for assessing glioma malignancy and predicting tumor behavior. Special attention is given to the 2021 WHO Classification of Tumors of the Central Nervous System, emphasizing the integration of molecular diagnostics in glioma classification, significantly impacting treatment decisions. The review also explores radiogenomics, which correlates imaging features with molecular markers to tailor personalized treatment strategies. Despite technological progress, MRI protocol standardization and result interpretation challenges persist, affecting diagnostic consistency across different settings. Furthermore, the review addresses MRI's capacity to distinguish between tumor recurrence and pseudoprogression, which is vital for patient management. The necessity for greater standardization and collaborative research to harness MRI's full potential in glioma diagnosis and personalized therapy is highlighted, advocating for an enhanced understanding of glioma biology and more effective treatment approaches.


Asunto(s)
Neoplasias Encefálicas , Glioma , Imagen por Resonancia Magnética , Humanos , Glioma/diagnóstico por imagen , Glioma/genética , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/genética , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen de Difusión por Resonancia Magnética/métodos , Biomarcadores de Tumor/genética
10.
J Clin Med ; 13(9)2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38731237

RESUMEN

Background/Objectives: Periapical lesions (PLs) are frequently detected in dental radiology. Accurate diagnosis of these lesions is essential for proper treatment planning. Imaging techniques such as orthopantomogram (OPG) and cone-beam CT (CBCT) imaging are used to identify PLs. The aim of this study was to assess the diagnostic accuracy of artificial intelligence (AI) software Diagnocat for PL detection in OPG and CBCT images. Methods: The study included 49 patients, totaling 1223 teeth. Both OPG and CBCT images were analyzed by AI software and by three experienced clinicians. All the images were obtained in one patient cohort, and findings were compared to the consensus of human readers using CBCT. The AI's diagnostic accuracy was compared to a reference method, calculating sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and F1 score. Results: The AI's sensitivity for OPG images was 33.33% with an F1 score of 32.73%. For CBCT images, the AI's sensitivity was 77.78% with an F1 score of 84.00%. The AI's specificity was over 98% for both OPG and CBCT images. Conclusions: The AI demonstrated high sensitivity and high specificity in detecting PLs in CBCT images but lower sensitivity in OPG images.

11.
J Clin Med ; 13(5)2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38592413

RESUMEN

Background: Temporomandibular joint disorder (TMD) is a common medical condition. Cone beam computed tomography (CBCT) is effective in assessing TMD-related bone changes, but image noise may impair diagnosis. Emerging deep learning reconstruction algorithms (DLRs) could minimize noise and improve CBCT image clarity. This study compares standard and deep learning-enhanced CBCT images for image quality in detecting osteoarthritis-related degeneration in TMJs (temporomandibular joints). This study analyzed CBCT images of patients with suspected temporomandibular joint degenerative joint disease (TMJ DJD). Methods: The DLM reconstructions were performed with ClariCT.AI software. Image quality was evaluated objectively via CNR in target areas and subjectively by two experts using a five-point scale. Both readers also assessed TMJ DJD lesions. The study involved 50 patients with a mean age of 28.29 years. Results: Objective analysis revealed a significantly better image quality in DLM reconstructions (CNR levels; p < 0.001). Subjective assessment showed high inter-reader agreement (κ = 0.805) but no significant difference in image quality between the reconstruction types (p = 0.055). Lesion counts were not significantly correlated with the reconstruction type (p > 0.05). Conclusions: The analyzed DLM reconstruction notably enhanced the objective image quality in TMJ CBCT images but did not significantly alter the subjective quality or DJD lesion diagnosis. However, the readers favored DLM images, indicating the potential for better TMD diagnosis with CBCT, meriting more study.

12.
Pol J Radiol ; 89: e161-e171, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38550960

RESUMEN

Radiological procedures utilising intravascular contrast media (ICM) are fundamental to modern medicine, enhancing diagnostics and treatment in diverse medical fields. However, the application of ICM has been constrained in patients with compromised kidney function due to perceived nephrotoxic risks, called contrast-induced nephropathy or contrastinduced acute kidney injury. Historical evidence marked ICM as a possible contributor to kidney damage. This led to restrictive guidelines advocating limited ICM use in patients with impaired renal function, preventing crucial radiographic interventions in patients with acute kidney injury (AKI) and chronic kidney disease. Recent advances challenge these traditional views. In particular, no direct causal relationship has been confirmed between contrast admi-nistration and elevated serum creatinine concentrations in humans. Furthermore, contemporary research models and meta-analyses do not associate AKI with contrast usage. This paper, prepared by a cross-disciplinary team of nephrologists and radiologists, presents updated guidelines for ICM application amid renal function impairments, emphasising the reduced nephrotoxic risks currently understood and loosening the previous restrictive approach in patients with renal dysfunction.

13.
Diagnostics (Basel) ; 14(6)2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38534992

RESUMEN

The purpose of this study was to evaluate whether intravoxel incoherent motion (IVIM) parameters can enhance the diagnostic performance of MRI in differentiating normal pancreatic parenchyma from solid pancreatic adenocarcinomas. This study included 113 participants: 66 patients diagnosed with pancreatic adenocarcinoma and 47 healthy volunteers. An MRI was conducted at 1.5 T MR unit, using nine b-values. Postprocessing involved analyzing both conventional monoexponential apparent diffusion coefficient (ADC) and IVIM parameters (diffusion coefficient D-pure molecular diffusion coefficient, perfusion-dependent diffusion coefficient D*-pseudodiffusion coeffitient, and perfusion fraction coefficient (f)) across four different b-value selections. Significantly higher parameters were found in the control group when using high b-values for the pure diffusion analysis and all b-values for the monoexponential analysis. Conversely, in the study group, the parameters were affected by low b-values. Most parameters could differentiate between normal and cancerous tissue, with D* showing the highest diagnostic performance (AUC 98-100%). A marked decrease in perfusion in the patients with pancreatic cancer, indicated by the significant differences in the D* medians between groups, was found. In conclusion, standard ADC maps alone may not suffice for a definitive pancreatic cancer diagnosis, and incorporating IVIM into MRI protocols is recommended, as the reduced tissue perfusion detected by the IVIM parameters is a promising marker for pancreatic adenocarcinoma.

14.
Neurol Neurochir Pol ; 58(2): 176-184, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38324117

RESUMEN

INTRODUCTION: Cognitive impairment occurs from the earliest stages of multiple sclerosis (MS) and progresses over time. The introduction of disease modifying therapies (DMTs) has changed the prognosis for MS patients, offering a potential opportunity for improvement in the cognitive arena as well. MATERIAL AND METHODS: 41 patients with relapsing-remitting multiple sclerosis (MS) were recruited to the study. Thirty patients were available for final follow-up and were included in the analysis. Baseline (BL) brain MRI including volumetry and neuropsychological tests were performed. Blood samples were collected at BL and follow-up (FU) and were tested for: vascular endothelial growth factor (VEGF), soluble vascular cell adhesion molecule-1 (sVCAM1), soluble platelet-endothelial CAM-1 (sPECAM1), and soluble intercellular CAM-1 (sICAM-1). Patients were invited for a final neuropsychological follow-up after a median of 6 years. Disease activity (relapses, EDSS increase, new/active brain lesions on MRI) was analysed between BL and FU. RESULTS: The study group deteriorated in the Rey-Osterrieth Complex Figure (ROCF) test (p = 0.001), but improved significantly in three other tests, i.e. semantic fluency test (p = 0.013), California Verbal Learning Test (CVLT, p = 0.016), and Word Comprehension Test (WCT, p < 0.001). EDSS increase correlated negatively with semantic fluency and WCT scores (r = -0.579, p = 0.001 and r = -0.391, p = 0.033, respectively). Improvements in semantic fluency test and WCT correlated positively with baseline deep grey matter, grey matter, and cortical volumes (p < 0.05, r > 0). Higher EDSS on FU correlated significantly negatively with baseline left and right pallidum, right caudate, right putamen, right accumbens, and cortical volume (p < 0.05, r < 0). No significant relationship was found between the number of relapses and EDSS on FU or neuropsychological deteriorations. Improvements in WCT and CVLT correlated positively with baseline sPECAM1 and sVCAM1 results, respectively (r > 0, p < 0.05). Deterioration in ROCF test correlated significantly with higher levels of baseline VEGF and sVCAM1 (p < 0.05). CONCLUSIONS: Brain volume is an important predictor of future EDSS and cognitive functions outcome. MS patients have a potential for improving in neuropsychological tests over time. It remains to be established whether this is related to successful disease modification with immunotherapy. Baseline volumetric measures are stronger predictors of cognitive performance than relapse activity, which yet again highlights the importance of atrophy in MS prognosis.


Asunto(s)
Disfunción Cognitiva , Progresión de la Enfermedad , Imagen por Resonancia Magnética , Esclerosis Múltiple Recurrente-Remitente , Pruebas Neuropsicológicas , Humanos , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/complicaciones , Esclerosis Múltiple Recurrente-Remitente/fisiopatología , Esclerosis Múltiple Recurrente-Remitente/sangre , Esclerosis Múltiple Recurrente-Remitente/psicología , Femenino , Masculino , Adulto , Estudios de Seguimiento , Disfunción Cognitiva/etiología , Persona de Mediana Edad , Pronóstico , Factor A de Crecimiento Endotelial Vascular/sangre
15.
Sci Rep ; 14(1): 3845, 2024 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-38360941

RESUMEN

To assess the image quality parameters of dual-energy computed tomography angiography (DECTA) 40-, and 60 keV virtual monoenergetic images (VMIs) combined with deep learning-based image reconstruction model (DLM) and iterative reconstructions (IR). CT scans of 28 post EVAR patients were enrolled. The 60 s delayed phase of DECTA was evaluated. Objective [noise, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR)] and subjective (overall image quality and endoleak conspicuity - 3 blinded readers assessment) image quality analyses were performed. The following reconstructions were evaluated: VMI 40, 60 keV VMI; IR VMI 40, 60 keV; DLM VMI 40, 60 keV. The noise level of the DLM VMI images was approximately 50% lower than that of VMI reconstruction. The highest CNR and SNR values were measured in VMI DLM images. The mean CNR in endoleak in 40 keV was accounted for as 1.83 ± 1.2; 2.07 ± 2.02; 3.6 ± 3.26 in VMI, VMI IR, and VMI DLM, respectively. The DLM algorithm significantly reduced noise and increased lesion conspicuity, resulting in higher objective and subjective image quality compared to other reconstruction techniques. The application of DLM algorithms to low-energy VMIs significantly enhances the diagnostic value of DECTA in evaluating endoleaks. DLM reconstructions surpass traditional VMIs and IR in terms of image quality.


Asunto(s)
Endofuga , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Endofuga/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Relación Señal-Ruido
16.
Pol J Radiol ; 89: e49-e53, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38371891

RESUMEN

Purpose: Medical imaging is one of the main methods of diagnosing COVID-19, along with real-time reverse trans-cription-polymerase chain reaction (RT-PCR) tests. The purpose of the study was to analyse the texture parameters of chest X-rays (CXR) of patients suspected of having COVID-19. Material and methods: Texture parameters of the CXRs of 70 patients with symptoms typical of COVID-19 infection were analysed using LIFEx software. The regions of interest (ROIs) included each lung separately, for which 57 para-meters were tested. The control group consisted of 30 healthy, age-matched patients with no pathological findings in CXRs. Results: According to the ROC analysis, 13 of the tested parameters differentiate the radiological image of lungs with COVID-19 features from the image of healthy lungs: GLRLM_LRHGE (AUC 0.91); DISCRETIZED_Q3 (AUC 0.90); GLZLM_HGZE (AUC 0.90); GLRLM_HGRE (AUC 0.89); DISCRETIZED_mean (AUC 0.89); DISCRETIZED_Q2 (AUC 0.61); GLRLM_SRHGE (AUC 0.87); GLZLM_LZHGE (AUC 0.87); GLZLM_SZHGE (AUC 0.84); DISCRETIZED_Q1 (AUC 0.81); NGLDM_Coarseness (AUC 0.70); DISCRETIZED_std (AUC 0.64); CONVENTIONAL_Q2 (AUC 0.61). Conclusions: Selected texture parameters of radiological CXRs make it possible to distinguish COVID-19 features from healthy ones.

17.
Pol J Radiol ; 89: e1-e5, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38371889

RESUMEN

The year 2023 marks 60 years since the first pacemaker was implanted in Poland. The number of implantable cardiac electrotherapy devices (CIEDs), including pacemakers, cardioverter-defibrillators, and resynchronization therapy systems, has been systematically increasing in the subsequent decades. It is estimated that nearly 500,000 Poles have an implanted cardiac electrotherapy device, making optimal diagnostic imaging with the use of magnetic resonance imaging (MRI) a clinically and epidemiologically important issue. MRI has become a gold diagnostic standard in many disease states. In this situation, it is believed that 50-70% of patients who have a cardiac electrotherapy device may have indications for an MRI examination later in life. For many years, an implanted cardiac electrotherapy device was considered a definite contraindication to MRI. However, MRI has become possible in most patients with CIED if certain procedures and precautions are followed. In these guidelines, we describe the basic rules that should be followed in order to perform a safe MRI examination in patients with different CIEDs. Despite all the risks and organizational factors described in the text, it seems that for many MRI departments, MRI in patients with CIEDs is achievable and should be implemented immediately. A second important issue is the need for dedicated financial support for these procedures from public health insurance.

18.
Dentomaxillofac Radiol ; 53(1): 52-59, 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38214946

RESUMEN

OBJECTIVES: To compare artificial intelligence (AI)-driven web-based platform and manual measurements for analysing facial asymmetry in craniofacial CT examinations. METHODS: The study included 95 craniofacial CT scans from patients aged 18-30 years. The degree of asymmetry was measured based on AI platform-predefined anatomical landmarks: sella (S), condylion (Co), anterior nasal spine (ANS), and menton (Me). The concordance between the results of automatic asymmetry reports and manual linear 3D measurements was calculated. The asymmetry rate (AR) indicator was determined for both automatic and manual measurements, and the concordance between them was calculated. The repeatability of manual measurements in 20 randomly selected subjects was assessed. The concordance of measurements of quantitative variables was assessed with interclass correlation coefficient (ICC) according to the Shrout and Fleiss classification. RESULTS: Erroneous AI tracings were found in 16.8% of cases, reducing the analysed cases to 79. The agreement between automatic and manual asymmetry measurements was very low (ICC < 0.3). A lack of agreement between AI and manual AR analysis (ICC type 3 = 0) was found. The repeatability of manual measurements and AR calculations showed excellent correlation (ICC type 2 > 0.947). CONCLUSIONS: The results indicate that the rate of tracing errors and lack of agreement with manual AR analysis make it impossible to use the tested AI platform to assess the degree of facial asymmetry.


Asunto(s)
Inteligencia Artificial , Asimetría Facial , Humanos , Asimetría Facial/diagnóstico por imagen , Reproducibilidad de los Resultados , Imagenología Tridimensional/métodos , Cefalometría/métodos
19.
J Clin Med ; 13(2)2024 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-38256478

RESUMEN

The advent of artificial intelligence (AI) in medicine has transformed various medical specialties, including orthodontics. AI has shown promising results in enhancing the accuracy of diagnoses, treatment planning, and predicting treatment outcomes. Its usage in orthodontic practices worldwide has increased with the availability of various AI applications and tools. This review explores the principles of AI, its applications in orthodontics, and its implementation in clinical practice. A comprehensive literature review was conducted, focusing on AI applications in dental diagnostics, cephalometric evaluation, skeletal age determination, temporomandibular joint (TMJ) evaluation, decision making, and patient telemonitoring. Due to study heterogeneity, no meta-analysis was possible. AI has demonstrated high efficacy in all these areas, but variations in performance and the need for manual supervision suggest caution in clinical settings. The complexity and unpredictability of AI algorithms call for cautious implementation and regular manual validation. Continuous AI learning, proper governance, and addressing privacy and ethical concerns are crucial for successful integration into orthodontic practice.

20.
J Clin Med ; 12(24)2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38137834

RESUMEN

Abdominal aortic aneurysms (AAAs) are a significant cause of mortality in developed countries. Endovascular aneurysm repair (EVAR) is currently the leading treatment method for AAAs. Due to the high sensitivity and specificity of post-EVAR complication detection, CT angiography (CTA) is the reference method for imaging surveillance in patients after EVAR. Many studies have shown the advantages of dual-energy CT (DECT) over standard polyenergetic CTA in vascular applications. In this article, the authors briefly discuss the technical principles and summarize the current body of literature regarding dual-energy computed tomography angiography (DECTA) in patients after EVAR. The authors point out the most useful applications of DECTA in this group of patients and its advantages over conventional CTA. To conduct this review, a search was performed using the PubMed, Google Scholar, and Web of Science databases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...