Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Polymers (Basel) ; 16(4)2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38399910

RESUMEN

The cross-linker methylene-bis-acrylamide is usually present in nanoMIPs obtained by solid-phase polymerization synthesis at 2 mol% concentration, with very few exceptions. Here, we studied the influence of variable amounts of methylene-bis-acrylamide in the range between 0 (no cross-linker) and 50 mol% concentration on the binding properties of rabbit IgG nanoMIPs. The binding parameters were determined by equilibrium binding experiments and the results show that the degree of cross-linking defines three distinct types of nanoMIPs: (i) those with a low degree of cross-linking, including nanoMIPs without cross-linker (0-05 mol%), showing a low binding affinity, high density of binding sites, and low selectivity; (ii) nanoMIPs with a medium degree of cross-linking (1-18 mol%), showing higher binding affinity, low density of binding sites, and high selectivity; (iii) nanoMIPs with a high degree of cross-linking (32-50 mol%), characterized by non-specific nanopolymer-ligand interactions, with low binding affinity, high density of binding sites, and no selectivity. In conclusion, the results are particularly relevant in the synthesis of high-affinity, high-selectivity nanoMIPs as they demonstrate that a significant gain in affinity and selectivity could be achieved with pre-polymerization mixtures containing quantities of cross-linker up to 10-20 mol%, well higher than those normally used in this technique.

2.
J Mater Chem B ; 12(8): 2139-2149, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38315042

RESUMEN

The lateral flow immunoassay (LFIA) technique is largely employed for the point-of-care detection of antibodies especially for revealing the immune response in serum. Visual LFIAs usually provide the qualitative yes/no detection of antibodies, while quantification requires some equipment, making the assay more expensive and complicated. To achieve visual semi-quantification, the alignment of several lines (made of the same antigen) along a LFIA strip has been proposed. The numbering of the reacting lines has been used to correlate with the quantity of some biomarkers in serum. Here, we designed the first semiquantitative LFIA for detecting antibodies and applied it to classify the immune response to SARS-CoV-2 raised by vaccination or natural infection. We used a recombinant spike receptor-binding domain (RBD) as the specific capture reagent to draw two test lines. The detection reagent was selected among three possible ligands that are able to bind to anti-spike human antibodies: the same RBD, staphylococcal protein A, and anti-human immunoglobulin G antibodies. The most convenient detector, adsorbed on gold nanoparticles, was chosen based on the highest correlation with an antibody titre of 171 human sera, measured by a reference serological method, and was the RBD (Spearman's rho = 0.84). Incorporated into the semiquantitative LFIA, it confirmed the ability to discriminate high- and low-titre samples and to classify them into two classes (Dunn's test, P < 0.05). The proposed approach enabled the semiquantification of the immune response to SARS-CoV-2 by the unaided eye observation, thus overcoming the requirement of costly and complicated equipment, and represents a general strategy for the development of semiquantitative serological LFIAs.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Humanos , SARS-CoV-2 , Estudios de Seguimiento , Oro , COVID-19/diagnóstico , Inmunoensayo , Vacunación , Anticuerpos , Inmunidad
3.
Anal Chem ; 96(6): 2297-2302, 2024 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-38289028

RESUMEN

The COVID-19 pandemic highlighted lateral flow immunoassay (LFIA) strips as the most known point-of-care (POC) devices enabling rapid and easy detection of relevant biomarkers by nonspecialists. However, these diagnostic tests are usually associated with the qualitative detection of the biomarker of interest. Alternatively, electrochemical-based diagnostics, especially known for diabetes care, enable quantitative determination of biomarkers. From an analytical point perspective, the combination of the two approaches might represent a step forward for the POC world: in fact, electrochemical transduction is attractive to be integrated into LFIA strips due to its simplicity, high sensitivity, fast signal generation, and cost effectiveness. In this work, a LFIA strip has been combined with an electrochemical transduction, yielding an electrochemical LFIA (eLFIA). As a proof-of-concept method, the detection of prostate-specific antigen has been carried out by combining a printed-electrochemical strip with the traditional LFIA tests. The electrochemical detection has been based on the measurement of Au ions produced from the dissolution of the gold nanoparticles previously captured on the test line. The analytical performances obtained at LFIA and eLFIA were compared, highlighting how the use of differential pulse voltammetry allowed for a lower detection limit (2.5-fold), respectively, 0.38 and 0.15 ng/mL, but increasing the time of analysis. Although the correlation between the two architectures confirmed the satisfactory agreement of outputs, this technical note has been thought to provide the reader a fair statement with regard to the strength and drawbacks about combining the two (apparently) competitor devices in a diagnostics field, namely, LFIA and electrochemical strips.


Asunto(s)
Nanopartículas del Metal , Antígeno Prostático Específico , Humanos , Masculino , Oro , Pandemias , Inmunoensayo/métodos , Biomarcadores , Límite de Detección
4.
Mikrochim Acta ; 191(1): 9, 2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38052755

RESUMEN

Antigenic lateral flow immunoassays (LFIAs) rely on the non-competitive sandwich format, including a detection (labelled) antibody and a capture antibody immobilised onto the analytical membrane. When the same antibody is used for the capture and the detection (single epitope immunoassay), the saturation of analyte epitopes by the probe compromises the capture and lowers the sensitivity. Hence, several factors, including the amount of the probe, the antibody-to-label ratio, and the contact time between the probe and the analyte before reaching the capture antibody, must be adjusted. We explored different designs of experiments (full-factorial, optimal, sub-optimal models) to optimise a multiplex sandwich-type LFIA for the diagnosis and serotyping of two Southern African Territory (SAT) serotypes of the foot-and-mouth disease virus, and to evaluate the reduction of the number of experiments in the development. Both assays employed single epitope sandwich, so most influencing variables on the sensitivity were studied and individuated. We upgraded a previous device increasing the sensitivity by a factor of two and reached the visual limit of detection of 103.7 and 104.0 (TCID/mL) for SAT 1 and SAT 2, respectively. The positioning of the capture region along the LFIA strip was the most influent variable to increase the detectability. Furthermore, we confirmed that the 13-optimal DoE was the most convenient approach for designing the device.


Asunto(s)
Virus de la Fiebre Aftosa , Animales , Serogrupo , Proyectos de Investigación , Inmunoensayo , Antígenos , Anticuerpos , Epítopos
5.
Biosensors (Basel) ; 13(6)2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37367032

RESUMEN

Highly active antiretroviral therapy (HAART) includes very potent drugs that are often characterized by high toxicity. Tenofovir (TFV) is a widely used drug prescribed mainly for pre-exposure prophylaxis (PreP) and the treatment of human immunodeficiency virus (HIV). The therapeutic range of TFV is narrow, and adverse effects occur with both underdose and overdose. The main factor contributing to therapeutic failure is the improper management of TFV, which may be caused by low compliance or patient variability. An important tool to prevent inappropriate administration is therapeutic drug monitoring (TDM) of compliance-relevant concentrations (ARCs) of TFV. TDM is performed routinely using time-consuming and expensive chromatographic methods coupled with mass spectrometry. Immunoassays, such as enzyme-linked immunosorbent assays (ELISAs) and lateral flow immunoassays (LFIAs), are based on antibody-antigen specific recognition and represent key tools for real-time quantitative and qualitative screening for point-of-care testing (POCT). Since saliva is a non-invasive and non-infectious biological sample, it is well-suited for TDM. However, saliva is expected to have a very low ARC for TFV, so tests with high sensitivity are required. Here, we have developed and validated a highly sensitive ELISA (IC50 1.2 ng/mL, dynamic range 0.4-10 ng/mL) that allows the quantification of TFV in saliva at ARCs and an extremely sensitive LFIA (visual LOD 0.5 ng/mL) that is able to distinguish between optimal and suboptimal ARCs of TFV in untreated saliva.


Asunto(s)
Fármacos Anti-VIH , Infecciones por VIH , Humanos , Tenofovir/uso terapéutico , Fármacos Anti-VIH/uso terapéutico , Infecciones por VIH/tratamiento farmacológico , Saliva , Ensayo de Inmunoadsorción Enzimática , Inmunoensayo
6.
Talanta ; 258: 124443, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36933298

RESUMEN

African swine fever (ASF) is a severe haemorrhagic infectious disease affecting suids, thus representing a great economic concern. Considering the importance of the early diagnosis, rapid point of care testing (POCT) for ASF is highly demanded. In this work, we developed two strategies for the rapid onsite diagnosis of ASF, based on Lateral Flow Immunoassay (LFIA) and Recombinase Polymerase Amplification (RPA) techniques. The LFIA was a sandwich-type immunoassay exploiting a monoclonal antibody directed towards the p30 protein of the virus (Mab). The Mab was anchored onto the LFIA membrane to capture the ASFV and was also labelled with gold nanoparticles for staining the antibody-p30 complex. However, the use of the same antibody for capturing and as detector ligand showed a significant competitive effect for antigen binding, so required an experimental design to minimize reciprocal interference and maximize the response. The RPA assay, employing primers to the capsid protein p72 gene and an exonuclease III probe, was performed at 39 °C. The limit of detection of the method was assessed using a plasmid encoding the target gene and resulted in 5 copy/µL. The new LFIA and RPA were applied for ASFV detection in the animal tissues usually analysed by conventional assays (i.e., real-time PCR), such as kidney, spleen, and lymph nodes. A simple and universal virus extraction protocol was applied for sample preparation, followed by DNA extraction and purification for the RPA. The LFIA only required the addition of 3% H2O2 to limit matrix interference and prevent false positive results. The two rapid methods (25 min and 15 min were needed to complete the analysis for RPA and LFIA, respectively) showed high diagnostic specificity (100%) and sensitivity (93% and 87% for LFIA and RPA, respectively) for samples with high viral load (Ct < 27). False negative results were observed for samples with low viral load (Ct > 28) and/or also containing specific antibodies to ASFV, which decreased antigen availability and were indicative of a chronic, poorly transmissible infection. The simple and rapid sample preparation and the diagnostic performance of the LFIA suggested its large practical applicability for POC diagnosis of ASF.


Asunto(s)
Virus de la Fiebre Porcina Africana , Fiebre Porcina Africana , Nanopartículas del Metal , Porcinos , Animales , Virus de la Fiebre Porcina Africana/genética , Fiebre Porcina Africana/diagnóstico , Oro , Peróxido de Hidrógeno , Recombinasas , Anticuerpos Monoclonales
7.
Polymers (Basel) ; 14(23)2022 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-36501605

RESUMEN

In molecularly imprinted polymers, non-specific interactions are generally based on weak forces between the polymer surface and the sample matrix. Thus, additives able to interfere with such interactions should be able to significantly reduce any non-specific binding effect. Surfactants represent an interesting class of substances as they are cheap and easily available. Here, we present a study of the effect of three surfactants (the anionic sodium dodecylsulphate, SDS, the cationic cetyltrimethylammonium bromide (CTAB) and the non-ionic polyoxyethylene-(20)-sorbitan monolaurate Tween 20) on the binding affinity of a 2,4,5-trichlorophenoxyacetic acid (2,4,5-T)-imprinted polymer for the template and its analogue 2,4-dichlorophenoxyacetic acid (2,4-D). The experimental results indicate that increasing amounts of surfactant decrease the binding affinity for the ligands strongly for the ionic ones, and more weakly for the non-ionic one. This effect is general, as it occurs for both 2,4,5-T and 2,4-D and for both the imprinted and the not-imprinted polymers. It also proves that the magnitude of this effect mainly depends on the presence or absence of an ionic charge, and that the hydrophobic "tail" of surfactants plays only a minor role.

8.
Toxins (Basel) ; 14(12)2022 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-36548748

RESUMEN

A new green competitive ELISA for aflatoxin M1 quantification in raw milk was developed. This diagnostic tool is based on an anti AFM1 mAb produced by plant molecular farming in alternative to classical systems. Our assay, showing an IC50 below 25 ng/L, fits with the requirements of EU legislation limits for AFM1 (50 ng/L). Optimal accuracy was achieved in correspondence of the decision levels (25 and 50 ng/L), and the assay enabled AFM1 quantification in the range 5-110 ng/L, with limit of detection 3 ng/L. Moreover, to evaluate a real applicability in diagnostics, raw milk-spiked samples were analysed, achieving satisfactory recovery rates of AFM1. In conclusion, an efficient and ready-to-use diagnostic assay for the quantification of aflatoxin M1 in milk, based on a plant-produced recombinant mAb, has been successfully developed.


Asunto(s)
Aflatoxina M1 , Anticuerpos , Animales , Ensayo de Inmunoadsorción Enzimática , Aflatoxina M1/análisis , Inmunoensayo , Leche/química , Contaminación de Alimentos/análisis
9.
Biosensors (Basel) ; 12(9)2022 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-36140124

RESUMEN

Lumpy skin disease (LSD) is an infectious disease affecting bovine with severe symptomatology. The implementation of effective control strategies to prevent infection outbreak requires rapid diagnostic tools. Two monoclonal antibodies (mAbs), targeting different epitopes of the LSDV structural protein p32, and gold nanoparticles (AuNPs) were used to set up a colorimetric sandwich-type lateral flow immunoassay (LFIA). Combinations including one or two mAbs, used either as the capture or detection reagent, were explored to investigate the hook effect due to antigen saturation by the detector antibody. The mAb-AuNP preparations were optimized by a full-factorial design of experiment to achieve maximum sensitivity. Opposite optimal conditions were selected when one Mab was used for capture and detection instead of two mAbs; thus, two rational routes for developing a highly sensitive LFIA according to Mab availability were outlined. The optimal LFIA for LSDV showed a low limit of detection (103.4 TCID50/mL), high inter- and intra-assay repeatability (CV% < 5.3%), and specificity (no cross-reaction towards 12 other viruses was observed), thus proving to be a good candidate as a useful tool for the point-of-need diagnosis of LSD.


Asunto(s)
Virus de la Dermatosis Nodular Contagiosa , Nanopartículas del Metal , Animales , Bovinos , Anticuerpos Monoclonales , Epítopos , Oro/química , Inmunoensayo , Nanopartículas del Metal/química
10.
J Mater Chem B ; 10(35): 6724-6731, 2022 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-35343553

RESUMEN

Solid phase synthesis (SPS) of molecularly imprinted nanopolymers (nanoMIPs) represents an innovative method to prepare nanomaterials with tailor-made molecular recognition properties towards peptides and proteins. The synthesis of nanoMIPs by SPS usually involves a pre-polymerization formulation, where the cross-linker is invariably N,N'-methylen-bis-acrylamide (BIS). To date, the effect of cross-linkers on the binding properties of nanoMIPs prepared using cross-linkers other than BIS has never been reported. In this work, in order to investigate the effect of different cross-linkers in protein-imprinted nanoMIPs prepared by SPS, alongside BIS we considered other similar cross-linkers: N,N'-ethylene dimethacrylamide (EDAM), N,O-bis-methacryloylethanolamine (NOBE), ethylene glycol dimethacrilate (EDMA) and glycerol dimethacrylate (GDMA), replacing BIS with them in pre-polymerization mixtures. The synthetized nanoMIPs were homogeneous, with a polydispersity index of 0.24-0.30 and a mean diameter of 129-169 nm in water. The binding properties of the nanoMIPs were measured via equilibrium partition experiments with the template, rabbit IgG (RIgG), and the selectivity was evaluated with respect to bovine IgG (BIgG), bovine serum albumin (BSA) and hen egg lysozyme (LZM). The experimental results show that all the cross-linkers, with the exception of EDMA, endowed nanoMIPs with high binding affinities for the template (BIS: 16.0 × 106 mol-1 L, EDAM: 8.8 × 106 mol-1 L, NOBE: 15.8 × 106 mol-1 L, and GDMA: 12.8 × 106 mol-1 L), medium to high imprinting factors (BIS: 12.3, EDAM: 5.5, NOBE: 7.2, and GDMA: 11.6) and good selectivity towards other proteins but markedly dependent on the structure of the cross-linker, confirming the importance of the latter in the SPS of imprinted nanopolymers.


Asunto(s)
Impresión Molecular , Acrilamidas , Animales , Glicoles de Etileno , Etilenos , Glicerol , Inmunoglobulina G , Impresión Molecular/métodos , Polímeros/química , Conejos , Albúmina Sérica Bovina , Agua
11.
Anal Bioanal Chem ; 414(18): 5473-5482, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35149878

RESUMEN

Lateral flow immunoassay (LFIA) is widely employed as point-of-care tests (POCT) for the diagnosis of infectious diseases. The accuracy of LFIA largely depends on the quality of the immunoreagents used. Typical LFIAs to reveal the immune response to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) employ anti-human immunoglobulin (hIG) antibodies and recombinant viral antigens, which usually are unstable and poorly soluble. Broad selective bacterial proteins, such as Staphylococcal protein A (SpA) and Streptococcal protein G (SpG) can be considered alternatives to anti-hIG to increase versatility and sensitivity of serological LFIAs because of their high binding capacity, interspecies reactivity, and robustness. We developed two colorimetric LFA devices including SpA and SpG linked to gold nanoparticles (GNP) as detectors and explored the use of a specific, stable, and soluble immunodominant fraction of the nucleocapsid protein from SARS-CoV-2 as the capturing agent. The optimal amount of SpA-GNP and SpG-GNP conjugates and the protein-to-GNP ratios were defined through a full factorial experimental design to maximize the diagnostic sensitivity of the LFIAs. The new LFA devices were applied to analyze 105 human serum samples (69 positive and 36 negatives according to reference molecular diagnostic methods). The results showed higher sensitivity (89.9%, 95% CI 82.7-97.0) and selectivity (91.7%, 82.6-100) for the SpA-based compared to the SpG-based LFA. In addition, 18 serum samples from cats and dogs living with COVID-19 patients were analyzed and 14 showed detectable levels of anti-SARS-CoV-2 antibodies, thus illustrating the flexibility of the SpA- and SpG-based LFAs.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Animales , Anticuerpos Antivirales , COVID-19/diagnóstico , Gatos , Perros , Oro/química , Inmunoensayo/métodos , Nanopartículas del Metal/química , SARS-CoV-2 , Sensibilidad y Especificidad
12.
Talanta ; 240: 123155, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34942474

RESUMEN

The foot-and-mouth disease (FMD) is the most important transboundary viral disease of livestock in the international context, because of its extreme contagiousness, widespread diffusion, and severe impact on animal trade and animal productions. The rapid and on-field detection of the virus responsible for the FMD represents an urgent demand to efficiently control the diffusion of the infection, especially in low resource setting where the FMD is endemic. Colorimetric lateral flow immunoassay (LFIA) is largely used for the development of rapid tests, due to the extreme simplicity, cost-effectiveness, and on-field operation. In this work, two multiplex LFIA devices were designed for the diagnosis of FMD and the simultaneous identification of major circulating serotypes of the FMD virus. The LFIAs relied on the sandwich-type immunoassay and combined a set of well-characterised monoclonal antibodies (mAb) pairs. One LFIA aimed at detecting and identifying O, A and Asia-1 serotypes, the second device enabled the detection and differentiation of the SAT 1 and SAT 2 serotypes. Both devices also incorporated a broad-specific test line reporting on infection from FMDV, regardless the strain and the serotype involved. Accordingly, five and four reactive zones were arranged in the two devices to achieve a total of six simultaneous analyses. The development of the two multiplex systems highlighted for the first time the relevance of the mAb positioning along the LFIA strip in connection with the use of the same or different mAb as capture and detector ligands. In fact, the excess of detector mAb typically employed for increasing the sensitivity of sandwich immunoassay induced a new type of hook effect when combined with the same ligand used as the capture. This effect strongly impacted assay sensitivity, which could be improved by an intelligent alignment of the mAb pairs along the LFIA strip. The analytical and diagnostic performances of the two LFIAs were studied by testing reference FMDV strains grown in cell cultures and some representative field samples (epithelium homogenates). Almost equivalent sensitivity and specificity to those of a reference Ag-ELISA kit were shown, except for the serotype SAT 2. These simple devices are suitable in endemic regions for in-field diagnosis of FMD accompanied by virus serotyping and, moreover, could be deployed and used for rapid confirmation of secondary outbreaks after FMD incursions in free-areas, thus contributing to promptly implement control measures.


Asunto(s)
Virus de la Fiebre Aftosa , Fiebre Aftosa , Animales , Anticuerpos Monoclonales , Anticuerpos Antivirales , Fiebre Aftosa/diagnóstico , Inmunoensayo , Serogrupo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...