Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Pract Radiat Oncol ; 9(2): e180-e186, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30342181

RESUMEN

PURPOSE: We assessed the effect of elective extended field radiation (EFRT) and nodal dose escalation on locoregional control and survival in patients with node-positive cervical cancer treated with definitive chemoradiation at 2 academic institutions. METHODS AND MATERIALS: Patients with cervical cancer with pelvic and/or paraortic lymph node (PALN) metastases treated with definitive chemoradiation between 2004 and 2011 were retrospectively reviewed. Patterns of failure were recorded. The impact of tumor and treatment on survival or recurrence were evaluated. RESULTS: A total of 78 patients were included. Median follow-up in surviving patients was 34 months. The 3-year overall survival (OS) and disease-free survival (DFS) were 65% and 50%, respectively (all patients), 68% and 52% (pelvic lymph nodes), and 59% and 48% (PALN). OS or DFS in pelvic-only versus PALN-positive patients was not significantly different (log-rank P = .24). Recurrences were distant (n = 22), PALN (n = 6), central pelvis (n = 5), pelvic lymph node (n = 3), and suspended ovary (n = 1). Higher nodal prescribed dose (range, 45-60 Gy) and elective EFRT did not affect DFS or OS (Cox proportional hazards P > .05). There was a trend toward decreased regional recurrence with higher nodal dose (hazard ratio, 0.85 per Gy increase; Cox proportional hazards P = .08). Elective EFRT did not affect PALN failure rate, OS, or DFS (Cox proportional hazards P > .05). CONCLUSIONS: Survival of patients with PALN involvement was similar to those with pelvic-only nodes. Higher nodal dose may improve regional control but did not affect survival. Elective extended-field radiation did not affect outcomes in this cohort. Most failures were distant, emphasizing the potential role of systemic therapy to improve outcomes.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Ganglios Linfáticos/efectos de la radiación , Metástasis Linfática/radioterapia , Recurrencia Local de Neoplasia/epidemiología , Neoplasias del Cuello Uterino/terapia , Adulto , Anciano , Quimioradioterapia/métodos , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Ganglios Linfáticos/patología , Metástasis Linfática/patología , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Recurrencia Local de Neoplasia/prevención & control , Estadificación de Neoplasias , Pelvis , Dosificación Radioterapéutica , Estudios Retrospectivos , Neoplasias del Cuello Uterino/mortalidad , Neoplasias del Cuello Uterino/patología
2.
Brachytherapy ; 17(5): 742-746, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29861268

RESUMEN

PURPOSE: Doppler ultrasound (US) gives real-time information regarding anatomy and blood vessel location to guide needle placement for gynecologic interstitial (IS) brachytherapy (BT). We retrospectively assessed Doppler US images for vessel quantity, size, and distribution in cervical cancer patients undergoing high-dose-rate BT at our institution. METHODS AND MATERIALS: Eleven consecutive patients undergoing IS high-dose-rate BT implants for cervical cancer between 2015 and 2017 were included. Transrectal Doppler US was used for real-time image guidance. US images were retrospectively evaluated. Vessel quantity, size, and distribution at superior and inferior levels of the cervix were recorded. Correlation of vessel quantity with tumor size and International Federation of Gynecology and Obstetrics stage was evaluated. RESULTS: Average vessel quantity was 4.2 in the inferior cervix and 3.8 in the superior cervix (range 1-11). Median vessel diameter was 2 mm in the inferior cervix and 2 mm in the superior cervix (range 1-6 mm). The most common location was posterolateral (3:00-5:00 and 7:00-9:00), outer third (78% of vessels inferiorly, 64% of vessels superiorly). Vessel quantity was correlated to initial tumor size superiorly (p = 0.04, paired t-test) but not inferiorly (p = 0.31, paired t-test). There was no correlation between vessel quantity and International Federation of Gynecology and Obstetrics stage (p > 0.05, analysis of variance). Doppler US was successfully used to guide needle placement away from visualized blood vessels with no incidents of hemorrhage in these patients. CONCLUSIONS: Doppler US is a useful tool to guide needle placement for IS BT for cervical cancer. Vessel quantity varied with increased vessel quantity seen higher in the cervix for larger tumors. Vessels were most commonly distributed in the outer third of the posterolateral cervix.


Asunto(s)
Braquiterapia/métodos , Endosonografía/métodos , Agujas , Radioterapia Guiada por Imagen/métodos , Ultrasonografía Doppler/métodos , Neoplasias del Cuello Uterino/radioterapia , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Dosificación Radioterapéutica , Recto , Estudios Retrospectivos , Neoplasias del Cuello Uterino/irrigación sanguínea , Neoplasias del Cuello Uterino/diagnóstico
3.
J Contemp Brachytherapy ; 8(3): 208-14, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27504130

RESUMEN

PURPOSE: Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS: Three brachytherapy patients with unique clinical needs were identified as likely to benefit from a customized vaginal applicator. Patient 1 underwent intracavitary vaginal cuff brachytherapy after hysterectomy and chemotherapy for stage IA papillary serous endometrial cancer using a custom printed 2.75 cm diameter segmented vaginal cylinder with a central channel. Patient 2 underwent interstitial brachytherapy for a vaginal cuff recurrence of endometrial cancer after prior hysterectomy, whole pelvis radiotherapy, and brachytherapy boost. We printed a 2 cm diameter vaginal cylinder with one central and six peripheral catheter channels to fit a narrow vaginal canal. Patient 3 underwent interstitial brachytherapy boost for stage IIIA vulvar cancer with vaginal extension. For more secure applicator fit within a wide vaginal canal, we printed a 3.5 cm diameter solid cylinder with one central tandem channel and ten peripheral catheter channels. The applicators were printed in a biocompatible, sterilizable thermoplastic. RESULTS: Patient 1 received 31.5 Gy to the surface in three fractions over two weeks. Patient 2 received 36 Gy to the CTV in six fractions over two implants one week apart, with interstitial hyperthermia once per implant. Patient 3 received 18 Gy in three fractions over one implant after 45 Gy external beam radiotherapy. Brachytherapy was tolerated well with no grade 3 or higher toxicity and no local recurrences. CONCLUSIONS: We established a workflow to rapidly manufacture and implement customized vaginal applicators that can be sterilized and are made of biocompatible material, resulting in high-quality brachytherapy for patients whose anatomy is not ideally suited for standard, commercially available applicators.

4.
Clin Breast Cancer ; 16(5): 396-401, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27292181

RESUMEN

INTRODUCTION/BACKGROUND: We evaluated heart dose from left breast radiotherapy with 2-dimensional (2D) versus 3-dimensional (3D) plans. PATIENTS AND METHODS: Treatment plans from patients treated with standard fractionation for left breast cancer from 2003 to 2013 were reviewed, with patients grouped into 3 cohorts: 2003 to 2004 ("2D", with computed tomography scans for dose calculation but fields defined using simulation films; n = 29), 2005 to 2006 ("2D-post," after several influential articles on heart dose were published; n = 31), and 2007 to 2013 ("3D"; n = 256). All patients were treated with free-breathing technique. Heart volumes were retrospectively contoured for the earlier 2 cohorts. Mean heart dose (MHD) and percentage of structure receiving at least 25 Gy (V25 Gy) and percentage of structure receiving at least 5 Gy for the whole heart, left ventricle (LV), right ventricle (RV), and both ventricles were recorded and compared among cohorts. RESULTS: MHD was 345 cGy (2D), 213 cGy (2D-post) and 213 cGy (3D). LV V25 Gy was 6.3%, 1.5%, and 1.1%, respectively. Lower doses were seen over time for all indices (analysis of variance, P < .0001). Post hoc tests indicated significantly higher doses for 2D versus 2D-post or 3D cohorts (P ≤ .001) for all parameters except RV V25 Gy (P = .24). CONCLUSION: Heart doses were higher with 2D versus 3D plans. Cardiac doses and resulting toxicity with modern 3D planning might be lower than those in previous reports.


Asunto(s)
Corazón/efectos de la radiación , Traumatismos por Radiación/prevención & control , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Adyuvante/efectos adversos , Neoplasias de Mama Unilaterales/radioterapia , Mama/diagnóstico por imagen , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Imagenología Tridimensional , Dosificación Radioterapéutica , Radioterapia Adyuvante/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Neoplasias de Mama Unilaterales/diagnóstico por imagen
5.
Am J Clin Oncol ; 38(6): 600-4, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26595685

RESUMEN

OBJECTIVE: Dose-response relationships for meningioma radiosurgery are poorly characterized. We evaluated determinants of local recurrence for meningiomas treated with Gamma Knife radiosurgery (GKRS), to guide future treatment approaches to optimize tumor control. MATERIALS AND METHODS: A total of 101 consecutive patients (108 tumors) who underwent GKRS for benign, atypical, or malignant meningiomas between 1998 and 2011 were studied. Local recurrence was assessed. Cox proportional hazards and logistic regression analyses were used to determine the association of patient-related, tumor-related, and treatment-related characteristics with local recurrence. Acute and late toxicity was evaluated. RESULTS: World Health Organization (2007 classification) tumor grade was I (82%), II (11%), or III (7%). Median dose was 14 Gy (range, 10 to 18 Gy) for grade I tumors and 16 Gy (range, 12 to 20 Gy) for grade II and III tumors. Median follow-up was 25 months (maximum, 17 y). Two- /5-year actuarial local control rates were 100%/98% for grade I tumors and 76%/56% for grade II/III tumors. Higher tumor grade and lower GKRS dose were associated with local failure. In this cohort, there was a 42% relative reduction in local recurrence for each 1 Gy of dose escalation. CONCLUSIONS: Treatment was well tolerated with no moderate or severe toxicity. Tumor control was excellent in benign tumors and suboptimal in higher grade tumors. Because the main determinant of local recurrence was GKRS dose, we recommend dose escalation for atypical or malignant tumors to doses between 16 and 20 Gy where critical structures allow.


Asunto(s)
Neoplasias Meníngeas/cirugía , Meningioma/cirugía , Recurrencia Local de Neoplasia , Radiocirugia/métodos , Adulto , Anciano , Anciano de 80 o más Años , Edema Encefálico/etiología , Estudios de Cohortes , Relación Dosis-Respuesta en la Radiación , Femenino , Cefalea/etiología , Humanos , Hipoestesia/etiología , Modelos Logísticos , Masculino , Neoplasias Meníngeas/patología , Meningioma/patología , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Radiocirugia/efectos adversos , Estudios Retrospectivos , Cuero Cabelludo , Carga Tumoral , Trastornos de la Visión/etiología
6.
Int J Radiat Oncol Biol Phys ; 92(5): 1093-1100, 2015 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-26194683

RESUMEN

PURPOSE: Evaluate the efficacy and toxicity of image guided brachytherapy using inverse planning simulated annealing (IPSA) high-dose-rate brachytherapy (HDRB) boost for locoregionally advanced cervical cancer. METHODS AND MATERIALS: From December 2003 through September 2009, 111 patients with primary cervical cancer were treated definitively with IPSA-planned HDRB boost (28 Gy in 4 fractions) after external radiation at our institution. We performed a retrospective review of our experience using image guided brachytherapy. Of the patients, 70% had a tumor size >4 cm, 38% had regional nodal disease, and 15% had clinically evident distant metastasis, including nonregional nodal disease, at the time of diagnosis. Surgical staging involving pelvic lymph node dissection was performed in 15% of patients, and 93% received concurrent cisplatin-based chemotherapy. Toxicities are reported according to the Common Terminology Criteria for Adverse Events version 4.0 guidelines. RESULTS: With a median follow-up time of 42 months (range, 3-84 months), no acute or late toxicities of grade 4 or higher were observed, and grade 3 toxicities (both acute and late) developed in 8 patients (1 constitutional, 1 hematologic, 2 genitourinary, 4 gastrointestinal). The 4-year Kaplan-Meier estimate of late grade 3 toxicity was 8%. Local recurrence developed in 5 patients (4 to 9 months after HDRB), regional recurrence in 3 (6, 16, and 72 months after HDRB), and locoregional recurrence in 1 (4 months after HDR boost). The 4-year estimates of local, locoregional, and distant control of disease were 94.0%, 91.9%, and 69.1%, respectively. The overall and disease-free survival rates at 4 years were 64.3% (95% confidence interval [CI] of 54%-73%) and 61.0% (95% CI, 51%-70%), respectively. CONCLUSIONS: Definitive radiation by use of inverse planned HDRB boost for locoregionally advanced cervical cancer is well tolerated and achieves excellent local control of disease. However, overall survival continues to be limited by the high rates of distant metastasis.


Asunto(s)
Braquiterapia/métodos , Radioterapia Guiada por Imagen/métodos , Neoplasias del Cuello Uterino/patología , Neoplasias del Cuello Uterino/radioterapia , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/tratamiento farmacológico , Adenocarcinoma/mortalidad , Adenocarcinoma/patología , Adenocarcinoma/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Braquiterapia/efectos adversos , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/tratamiento farmacológico , Carcinoma de Células Escamosas/mortalidad , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/radioterapia , Estudios de Cohortes , Intervalos de Confianza , Supervivencia sin Enfermedad , Femenino , Hematuria/etiología , Humanos , Estimación de Kaplan-Meier , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Traumatismos por Radiación/patología , Radiografía , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Factores de Tiempo , Carga Tumoral , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/tratamiento farmacológico , Neoplasias del Cuello Uterino/mortalidad
7.
J Appl Clin Med Phys ; 16(1): 5168, 2015 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-25679174

RESUMEN

The purpose of this study was to evaluate the radiation attenuation properties of PC-ISO, a commercially available, biocompatible, sterilizable 3D printing material, and its suitability for customized, single-use gynecologic (GYN) brachytherapy applicators that have the potential for accurate guiding of seeds through linear and curved internal channels. A custom radiochromic film dosimetry apparatus was 3D-printed in PC-ISO with a single catheter channel and a slit to hold a film segment. The apparatus was designed specifically to test geometry pertinent for use of this material in a clinical setting. A brachytherapy dose plan was computed to deliver a cylindrical dose distribution to the film. The dose plan used an 192Ir source and was normalized to 1500 cGy at 1 cm from the channel. The material was evaluated by comparing the film exposure to an identical test done in water. The Hounsfield unit (HU) distributions were computed from a CT scan of the apparatus and compared to the HU distribution of water and the HU distribution of a commercial GYN cylinder applicator. The dose depth curve of PC-ISO as measured by the radiochromic film was within 1% of water between 1 cm and 6 cm from the channel. The mean HU was -10 for PC-ISO and -1 for water. As expected, the honeycombed structure of the PC-ISO 3D printing process created a moderate spread of HU values, but the mean was comparable to water. PC-ISO is sufficiently water-equivalent to be compatible with our HDR brachytherapy planning system and clinical workflow and, therefore, it is suitable for creating custom GYN brachytherapy applicators. Our current clinical practice includes the use of custom GYN applicators made of commercially available PC-ISO when doing so can improve the patient's treatment. 


Asunto(s)
Braquiterapia/instrumentación , Braquiterapia/métodos , Dosimetría por Película , Neoplasias de los Genitales Femeninos/radioterapia , Radioisótopos de Iridio/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Simulación por Computador , Femenino , Humanos , Método de Montecarlo , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X
9.
Nucleic Acids Res ; 41(17): 8308-18, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23821664

RESUMEN

Dyskerin is a nucleolar protein encoded by the DKC1 gene that (i) stabilizes the RNA component of the telomerase complex, and (ii) drives the site-specific pseudouridilation of rRNA. It is known that the partial lack of dyskerin function causes a defect in the translation of a subgroup of mRNAs containing internal ribosome entry site (IRES) elements such as those encoding for the tumor suppressors p27 and p53. In this study, we aimed to analyze what is the effect of the lack of dyskerin on the IRES-mediated translation of mRNAs encoding for vascular endothelial growth factor (VEGF). We transiently reduced dyskerin expression and measured the levels of the IRES-mediated translation of the mRNA encoding for VEGF in vitro in transformed and primary cells. We demonstrated a significant increase in the VEGF IRES-mediated translation after dyskerin knock-down. This translational modulation induces an increase in VEGF production in the absence of a significant upregulation in VEGF mRNA levels. The analysis of a list of viral and cellular IRESs indicated that dyskerin depletion can differentially affect IRES-mediated translation. These results indicate for the first time that dyskerin inhibition can upregulate the IRES translation initiation of specific mRNAs.


Asunto(s)
Regiones no Traducidas 5' , Proteínas de Ciclo Celular/fisiología , Proteínas Nucleares/fisiología , Iniciación de la Cadena Peptídica Traduccional , Factor A de Crecimiento Endotelial Vascular/genética , Proteínas de Ciclo Celular/antagonistas & inhibidores , Proteínas de Ciclo Celular/genética , Línea Celular Tumoral , Técnicas de Silenciamiento del Gen , Humanos , Proteínas Nucleares/antagonistas & inhibidores , Proteínas Nucleares/genética , Interferencia de ARN , ARN Mensajero/química , ARN Viral/química , Regulación hacia Arriba , Factor A de Crecimiento Endotelial Vascular/biosíntesis
10.
Front Oncol ; 3: 3, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23386995

RESUMEN

OBJECTIVES: Some patients are medically unfit for or averse to undergoing a brachytherapy boost as part of cervical cancer radiotherapy. In order to be able to definitively treat these patients, we assessed whether we could achieve a boost plan that would mimic our brachytherapy plans using external beam radiotherapy. METHODS: High dose rate brachytherapy plans of 20 patients with stage IIB cervical cancer treated with definitive chemoradiotherapy were included in this study. Patients had undergone computer tomography (CT) simulations with tandem and ovoids in place. Point "A" dose was 600-700 cGy. We attempted to replicate the boost dose distribution from brachytherapy plans using intensity-modulated radiotherapy (Varian Medical Systems, Palo Alto, CA, USA), volumetric modulated arc therapy (Rapid Arc, Varian Medical Systems, Palo Alto, CA, USA), or TomoTherapy (Accuray, Inc., Sunnyvale, CA, USA) with the brachytherapy 100% isodose line as our target. Target coverage, normal tissue dose, and brachytherapy point doses were compared with ANOVA. Two-sided p-values ≤0.05 were considered significant. RESULTS: External beam plans had excellent planning target volume (PTV) coverage, with no difference in mean PTV V95% among planning techniques (range 98-100%). External beam plans had lower bladder Dmax, small intestine Dmax, and vaginal mucosal point dose than brachytherapy plans, with no difference in bladder point dose, mean bladder dose, mean small intestine dose, or rectal dose. Femoral head dose, parametria point dose, and pelvic sidewall point dose were higher with external beam techniques than brachytherapy. CONCLUSIONS: External beam plans had comparable target coverage and potential for improved sparing of most normal tissues compared to tandem and ovoid brachytherapy.

11.
Radiother Oncol ; 102(1): 74-81, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21993404

RESUMEN

BACKGROUND AND PURPOSE: To determine the optimal method of targeting breast and regional nodes in selected breast cancer patients after axillary dissection, we compared the results of IMRT versus no IMRT, and CT-informed versus clinically-placed fields, in supine and prone positions. MATERIALS AND METHODS: Twelve consecutive breast cancer patients simulated both prone and supine provided the images for this study. Four techniques were used to target breast, level III axilla, and supraclavicular fossa in either position: a traditional three-field three-dimensional conformal radiotherapy (3DCRT) plan, a four-field 3DCRT plan using a posterior axillary boost field, and two techniques using a CT-informed target volume consisting of an optimized 3DCRT plan (CT-planned 3D) and an intensity-modulated radiotherapy (IMRT) plan. The prescribed dose was 50 Gy in 25 fractions. RESULTS: CT-planned 3D and IMRT techniques improved nodal PTV coverage. Supine, mean nodal PTV V50 was 50% (3-field), 59% (4-field), 92% (CT-planned 3D), and 94% (IMRT). Prone, V50 was 29% (3-field), 42% (4-field), 97% (CT-planned 3D), and 95% (IMRT). Prone positioning, compared to supine, and IMRT technique, compared to 3D, lowered ipsilateral lung V20. CONCLUSIONS: Traditional 3DCRT plans provide inadequate nodal coverage. Prone IMRT technique resulted in optimal target coverage and reduced ipsilateral lung V20.


Asunto(s)
Neoplasias de la Mama/radioterapia , Irradiación Linfática/métodos , Metástasis Linfática/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Análisis de Varianza , Axila , Femenino , Humanos , Posicionamiento del Paciente , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
12.
J Neurooncol ; 102(1): 121-7, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20623246

RESUMEN

Prognosis of diffuse intrinsic pontine gliomas (DIPGs) remains poor. Failure has been predominantly local, with leptomeningeal dissemination (LD) occurring in 4-33% of patients in pre-MRI era series. Routine craniospinal imaging after initial treatment may reveal other relapse patterns relapse. Sixteen consecutive pediatric patients with DIPG treated between 2006 and 2009 were retrospectively reviewed. Treatment regimens, recurrence patterns, survival, and pathologic diagnosis were recorded. Fourteen patients received involved-field radiotherapy to 54 Gy, and two patients received craniospinal irradiation for LD at presentation. Neuraxis MRI was performed at diagnosis and at 4 month intervals following radiotherapy. Fifteen patients have had progression of disease (median progression-free survival 5.0 ± 1.2 months), and 13 patients have died (median survival 9.0 ± 1.4 months). Local failure occurred in 12 patients (75%). LD occurred in nine patients (56%). LD was present at diagnosis in three patients, after initial staging and treatment in six patients, and during autopsy in two patients. Median overall survival was 12.0 ± 3.3 months without LD and 8.0 ± 2.1 months with LD (P = 0.059, log rank test). Median progression-free survival was 9.5 ± 3.9 months without LD and 3.0 ± 2.1 months with LD (P = 0.012, log rank test). The high incidence of LD probably reflects liberal use of spine MRI surveillance. All patients should undergo routine craniospinal imaging at diagnosis and follow-up. Central nervous system prophylaxis should be considered in future clinical trials.


Asunto(s)
Neoplasias del Tronco Encefálico/radioterapia , Imagen por Resonancia Magnética , Neoplasias Meníngeas/radioterapia , Recurrencia Local de Neoplasia/radioterapia , Puente , Adolescente , Adulto , Neoplasias del Tronco Encefálico/diagnóstico , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Masculino , Neoplasias Meníngeas/diagnóstico , Neoplasias Meníngeas/secundario , Recurrencia Local de Neoplasia/diagnóstico , Pronóstico , Estudios Prospectivos , Dosificación Radioterapéutica , Estudios Retrospectivos , Tasa de Supervivencia , Adulto Joven
13.
Pract Radiat Oncol ; 1(3): 156-62, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-24673945

RESUMEN

PURPOSE: To review our initial clinical experience with image-guided radiation therapy (IGRT) using cone-beam computed tomography (CBCT) for prostate bed localization in post-radical prostatectomy (RP) patients and to compare shift and acute toxicity results to our previously published IGRT experience with daily kV planar imaging. METHODS AND MATERIALS: Fifty patients treated with intensity modulated radiation therapy (IMRT) who had image guidance using either CBCT (n = 23) or kV planar imaging (n = 27) following RP were analyzed. Shifts were recorded in anterior-posterior, superior-inferior, and left-right axes. Total error was defined as the shift from initial setup based on skin markings to isocenter. Prostate bed motion (PBM) was defined as the change in prostate bed position relative to bones. Acute toxicity was graded according to the Radiation Therapy Oncology Group morbidity criteria. RESULTS: Total error (TE) was measured in 752 CBCTs and 725 kV planar image pairs. PBM was measured in 585 CBCTs and 384 kV planar image pairs. The average magnitudes of TE and PBM in the anterior-posterior, superior-inferior, and left-right axes were greater with kV planar imaging compared to CBCT. Frequencies of acute grade 2 gastrointestinal (13% vs 7%, P = .7) and genitourinary (9% vs 11%, P = 1.0) were similar for CBCT and kV planar imaging patients. No toxicities greater than grade 2 were seen. CONCLUSIONS: These results suggest that although the magnitudes of TE and PBM were larger with kV planar compared to CBCT, the levels of acute toxicity were acceptable and comparable between the two. The reasons for the differences are unclear, but we postulate that discernment of the prostate bed on the CBCT is more difficult. Further investigation is necessary to determine the reason for the shift differences and to evaluate the benefits and risks of CBCT in this setting.

14.
Laryngoscope ; 120(7): 1336-41, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20564718

RESUMEN

OBJECTIVES/HYPOTHESIS: Compliance to intensive multiweek radiation therapy (RT) regimens in head and neck cancer (HNC) patients is challenging, particularly among medically underserved patients with fewer financial and social resources. Treatment prolongation reduces local control and overall survival rates, making adherence to treatment a key factor in optimal outcome. We evaluated factors affecting compliance in medically underserved patients who received RT for HNC in a large municipal hospital setting in New York City. STUDY DESIGN: Retrospective review. METHODS: Treatment records of patients treated between July 2004 and August 2008 were reviewed. Number of and reasons for missed treatments were identified. Several demographic, toxicity, and treatment variables were analyzed for impact on compliance. RESULTS: Eighty consecutive HNC patients who underwent RT with a 5- to 7-week regimen were identified. Thirty-two patients (40%) missed no treatments, 36 (45%) missed one to six treatments, six (8%) missed seven to 14 treatments, two (3%) missed more than 14 treatments, and four (5%) did not complete treatment. Reasons for missed treatments were hospitalization (31% of events) and toxicity (20%). Patients with percutaneous endoscopic gastrostomy tube were more likely to miss treatments (P = .01, chi(2) test). No other variable showed a significant association with missed treatments (chi(2) test). CONCLUSIONS: Intensive RT for HNC can be delivered with very good adherence within a medically underserved population. Eighty-five percent of patients completed treatment with 0 to 6 days of interruption. Efforts to further improve adherence in this population are ongoing.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Cooperación del Paciente , Humanos , Ciudad de Nueva York , Clase Social
15.
Clin Interv Aging ; 4: 259-67, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19554097

RESUMEN

Hormonal deprivation therapy is well established for the treatment of locally advanced and metastatic prostate cancer, as well as the adjuvant treatment of some patients with localized disease. Long-acting gonadotropin releasing hormone (GnRH) agonists have become a mainstay of androgen deprivation therapy, due to their efficacy, tolerability, and convenience of use. One-month, 3-month, and 4-month depot leuprorelin formulations are well established and widely used to this end. Recently, a 6-month depot leuprorelin has been approved for use in advanced and metastatic prostate cancer patients. With similar efficacy and side effect profiles to earlier formulations, 6-month depot leuprorelin is a convenient treatment option for these patients. This review will highlight the role of GnRH agonists in the treatment of prostate cancer with a focus on the clinical efficacy, pharmacology, and patient-focused outcomes of the newer 6-month 45 mg depot leuprorelin formulation in comparison to available shorter-acting products.


Asunto(s)
Antineoplásicos Hormonales/administración & dosificación , Leuprolida/administración & dosificación , Neoplasias de la Próstata/tratamiento farmacológico , Antineoplásicos Hormonales/farmacología , Preparaciones de Acción Retardada , Relación Dosis-Respuesta a Droga , Humanos , Leuprolida/farmacología , Masculino , Estados Unidos
16.
Radiother Oncol ; 88(1): 20-5, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18524399

RESUMEN

OBJECTIVES: To report our experience using Image-Guided Radiation Therapy (IGRT) in patients undergoing post-prostatectomy irradiation. METHODS: Twenty-six patients were treated with radiotherapy following radical prostatectomy using Intensity Modulated Radiation Therapy (IMRT). Prostate bed localization was done using image guidance to align surgical clips relative to the reference isocenter on the planning digitally reconstructed radiographs. Assuming surgical clips to be surrogate for prostate bed, daily shifts in their position were calculated after aligning with the bony anatomy. Shifts were recorded in three dimensions. The acute toxicity was measured during and after completion of treatment. RESULTS: The average (standard deviation) prostate bed motion in anterior-posterior, superior-inferior and left-right directions were: 2.7mm (2.1), 2.4mm (2.1) and 1.0mm (1.7), respectively. The majority of patients experienced only grade 1 symptoms, two patients had grade 2 symptoms and none had grade 3 or higher acute toxicity. CONCLUSIONS: Daily IGRT is recommended for accurate target localization during radiation delivery to improve efficacy of treatment and enhance therapeutic ratio. Larger studies with longer follow-up are necessary to make definitive recommendations regarding magnitude of margin reduction around clinical target volume.


Asunto(s)
Prostatectomía , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/cirugía , Radiografía Intervencional , Planificación de la Radioterapia Asistida por Computador , Radioterapia Adyuvante/métodos , Anciano , Humanos , Masculino , Persona de Mediana Edad , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Radioterapia Adyuvante/efectos adversos , Terapia Recuperativa , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
18.
J Med Entomol ; 39(1): 115-20, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11931242

RESUMEN

We measured the abundance of mosquitoes [primarily Aedes vexans (Meigen) and Culex tarsalis Coquillett] at cliff swallow (Petrochelidon pyrrhonota Vieillot) colonies of different sizes in southwestern Nebraska in 1999. Using CO2 traps placed inside and outside of colonies, we found that total mosquito abundance increased significantly with the number of active cliff swallow nests at a colony site. We found no effect of date or weather conditions on the number of mosquitoes caught it the different sites. By classifying the landscape from aerial photographs within a 2-km-diameter circle centered on each colony site, we found no significant relationships between habitat type near a colony site and cliff swallow colony size or mosquito abundance. Proximity to livestock could not account for our results. Culex tarsalis was proportionately more likely to be caught inside a colony than at traps 30 in away, but the proportion of C. tarsalis inside a colony did not vary with colony size. Our results cannot be explained by date- or weather-related sampling artifacts or by differences in habitat between sites. Most likely, mosquitoes, especially A. vexans, are attracted to the vicinity of large cliff swallow colonies.


Asunto(s)
Aedes , Culex , Culicidae , Pájaros Cantores , Aedes/clasificación , Animales , Culex/clasificación , Culicidae/clasificación , Femenino , Densidad de Población
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA