Biomed Mater ; 15(3): 035003, 2020 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-31918424

RESUMEN

Artificial nerve guidance conduits (NGCs) are being investigated as an alternative to autografts, since autografts are limited in supply. A polycaprolactone (PCL)-based spiral NGC with crosslinked laminin on aligned nanofibers was evaluated in vivo post a successful in vitro assessment. PC-12 cell assays confirmed that the aligned nanofibers functionalized with laminin were able to guide and enhance neurite outgrowth. In the rodent model, the data demonstrated that axons were able to regenerate across the critical nerve gap, when laminin was present. Without laminin, the spiral NGC with aligned nanofibers group resulted in a random cluster of extracellular matrix tissue following injuries. The reversed autograft group performed best, showing the most substantial improvement based on nerve histological assessment and gastrocnemius muscle measurement. Nevertheless, the recovery time was too short to obtain meaningful data for the motor functional assessments. A full motor recovery may take up to years. An interesting observation was noted in the crosslinked laminin group. Numerous new blood capillary-like structures were found around the regenerated nerve. Owing to recent studies, we hypothesized that new blood vessel formation could be one of the key factors to increase the successful rate of nerve regeneration in the current study. Overall, these findings indicated that the incorporation of laminin into polymeric nerve conduits is a promising strategy for enhancing peripheral nerve regeneration. However, the best combination of contact-guidance cues, haptotactic cues, and chemotactic cues have yet to be realized. The natural sequence of nerve regeneration should be studied more in-depth before modulating any strategies.


Asunto(s)
Laminina/química , Regeneración Nerviosa , Nervios Periféricos/fisiología , Polímeros/química , Animales , Diferenciación Celular , Reactivos de Enlaces Cruzados/química , Electrofisiología , Matriz Extracelular/metabolismo , Regeneración Tisular Dirigida/métodos , Cinética , Masculino , Músculo Esquelético/patología , Nanofibras/química , Neuritas/metabolismo , Células PC12 , Poliésteres/química , Ratas , Ratas Sprague-Dawley , Nervio Ciático/lesiones , Andamios del Tejido/química
2.
J Biomed Mater Res B Appl Biomater ; 107(5): 1410-1419, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30265781

RESUMEN

Nerve guidance conduits (NGCs) are artificial substitutes for autografts, which serve as the gold standard in treating peripheral nerve injury. A recurring challenge in tissue engineered NGCs is optimizing the cross-sectional surface area to achieve a balance between allowing nerve infiltration while supporting maximum axonal extension from the proximal to distal stump. In this study, we address this issue by investigating the efficacy of an NGC with a higher cross-sectional surface composed of spiral structures and multi-channels, coupled with inner longitudinally aligned nanofibers and protein on aiding nerve repair in critical sized nerve defect. The NGCs were implanted into 15-mm-long rat sciatic nerve injury gaps for 4 weeks. Nerve regeneration was assessed using an established set of assays, including the walking track analysis, electrophysiological testing, pinch reflex assessment, gastrocnemius muscle measurement, and histological assessment. The results indicated that the novel NGC design yielded promising data in encouraging nerve regeneration within a relatively short recovery time. The performance of the novel NGC for nerve regeneration was superior to that of the control nerve conduits with tubular structures. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1410-1419, 2019.


Asunto(s)
Orientación del Axón , Regeneración Tisular Dirigida , Nanofibras/química , Regeneración Nerviosa , Traumatismos de los Nervios Periféricos , Nervio Ciático , Animales , Masculino , Traumatismos de los Nervios Periféricos/metabolismo , Traumatismos de los Nervios Periféricos/patología , Traumatismos de los Nervios Periféricos/terapia , Ratas , Ratas Sprague-Dawley , Nervio Ciático/lesiones , Nervio Ciático/patología , Nervio Ciático/fisiología
3.
Acta Biomater ; 73: 302-311, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29702292

RESUMEN

Recently in peripheral nerve regeneration, preclinical studies have shown that the use of nerve guidance conduits (NGCs) with multiple longitudinally channels and intra-luminal topography enhance the functional outcomes when bridging a nerve gap caused by traumatic injury. These features not only provide guidance cues for regenerating nerve, but also become the essential approaches for developing a novel NGC. In this study, a novel spiral NGC with aligned nanofibers and wrapped with an outer nanofibrous tube was first developed and investigated. Using the common rat sciatic 10-mm nerve defect model, the in vivo study showed that a novel spiral NGC (with and without inner nanofibers) increased the successful rate of nerve regeneration after 6 weeks recovery. Substantial improvements in nerve regeneration were achieved by combining the spiral NGC with inner nanofibers and outer nanofibrous tube, based on the results of walking track analysis, electrophysiology, nerve histological assessment, and gastrocnemius muscle measurement. This demonstrated that the novel spiral NGC with inner aligned nanofibers and wrapped with an outer nanofibrous tube provided a better environment for peripheral nerve regeneration than standard tubular NGCs. Results from this study will benefit for future NGC design to optimize tissue-engineering strategies for peripheral nerve regeneration. STATEMENT OF SIGNIFICANCE: We developed a novel spiral nerve guidance conduit (NGC) with coated aligned nanofibers. The spiral structure increases surface area by 4.5 fold relative to a tubular NGC. Furthermore, the aligned nanofibers was coated on the spiral walls, providing cues for guiding neurite extension. Finally, the outside of spiral NGC was wrapped with randomly nanofibers to enhance mechanical strength that can stabilize the spiral NGC. Our nerve histological data have shown that the spiral NGC had 50% more myelinated axons than a tubular structure for nerve regeneration across a 10 mm gap in a rat sciatic nerve. Results from this study can help further optimize tissue engineering strategies for peripheral nerve repair.


Asunto(s)
Regeneración Tisular Dirigida/métodos , Regeneración Nerviosa , Sistema Nervioso Periférico/fisiología , Nervio Ciático/patología , Ingeniería de Tejidos/métodos , Animales , Axones , Electrofisiología , Masculino , Microscopía Electrónica de Rastreo , Músculo Esquelético/fisiología , Nanofibras , Condicionamiento Físico Animal , Ratas , Ratas Sprague-Dawley , Solventes , Andamios del Tejido/química