Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 175
Filtrar
1.
bioRxiv ; 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38558964

RESUMEN

Magnetoencephalography (MEG) measures brain function via assessment of magnetic fields generated by neural currents. Conventional MEG uses superconducting sensors, which place significant limitations on performance, practicality, and deployment; however, the field has been revolutionised in recent years by the introduction of optically-pumped-magnetometers (OPMs). OPMs enable measurement of the MEG signal without cryogenics, and consequently the conception of 'OPM-MEG' systems which ostensibly allow increased sensitivity and resolution, lifespan compliance, free subject movement, and lower cost. However, OPM-MEG remains in its infancy with limitations on both sensor and system design. Here, we report a new OPM-MEG design with miniaturised and integrated electronic control, a high level of portability, and improved sensor dynamic range (arguably the biggest limitation of existing instrumentation). We show that this system produces equivalent measures when compared to an established instrument; specifically, when measuring task-induced beta-band, gamma-band and evoked neuro-electrical responses, source localisations from the two systems were highly comparable and temporal correlation was >0.7 at the individual level and >0.9 for groups. Using an electromagnetic phantom, we demonstrate improved dynamic range by running the system in background fields up to 8 nT. We show that the system is effective in gathering data during free movement (including a sitting-to-standing paradigm) and that it is compatible with simultaneous electroencephalography (EEG - the clinical standard). Finally, we demonstrate portability by moving the system between two laboratories. Overall, our new system is shown to be a significant step forward for OPM-MEG technology and offers an attractive platform for next generation functional medical imaging.

2.
ACS Med Chem Lett ; 15(4): 486-492, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38628796

RESUMEN

Neuropsychiatric disorders such as major depressive disorders and schizophrenia are often associated with disruptions to the normal 24 h sleep wake cycle. Casein kinase 1 (CK1δ) is an integral part of the molecular machinery that regulates circadian rhythms. Starting from a cluster of bicyclic pyrazoles identified from a virtual screening effort, we utilized structure-based drug design to identify and reinforce a unique "hinge-flip" binding mode that provides a high degree of selectivity for CK1δ versus the kinome. Pharmacokinetics, brain exposure, and target engagement as measured by ex vivo autoradiography are described for advanced analogs.

3.
Materials (Basel) ; 17(7)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38612100

RESUMEN

We demonstrate the growth of 3C-SiC with reduced planar defects on a micro-scale compliant substrate. Heteroepitaxial growth of 3C-SiC on trenches with a width and separation of 2 µm, etched into a Si(001) substrate, is found to suppress defect propagation through the epilayer. Stacking faults and other planar defects are channeled away from the center of the patterned structures, which are rounded through the use of H2 annealing at 1100 °C. Void formation between the columns of 3C-SiC growth acts as a termination point for defects, and coalescence of these columns into a continuous epilayer is promoted through the addition of HCl in the growth phase. The process of fabricating these compliant substrates utilizes standard processing techniques found within the semiconductor industry and is independent of the substrate orientation and offcut.

4.
ACS Nano ; 18(8): 6162-6175, 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38359902

RESUMEN

Nanomedicines exhibit multifaceted performances, yet their biopharmaceutics remain poorly understood and present several challenges in the translation from preclinical to clinical research. To address this issue and promote the production of high-quality nanomedicines, a systematic screening of the design space and in vivo performance is necessary. Establishing formulation performance specifications early on enables an informed selection of candidates and promotes the development of nanosimilars. The deconvolution of the pharmacokinetics enables the identification of key characteristics that influence their performances and disposition. Using an in vitro-in vivo rank-order relationship for doxorubicin nanoformulations, we defined in vitro release specifications for Doxil/Caelyx-like follow-on products. Additionally, our model predictions were used to establish the bioequivalence of Lipodox, a nanosimilar of Doxil/Caelyx. Furthermore, a virtual safe space was established, providing crucial insights into expected disposition kinetics and informing formulation development. By addressing bottlenecks in biopharmaceutics and formulation screening, our research advances the translation of nanomedicine from bench to bedside.


Asunto(s)
Doxorrubicina , Doxorrubicina/análogos & derivados , Polietilenglicoles , Doxorrubicina/farmacocinética , Polietilenglicoles/farmacocinética
5.
bioRxiv ; 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38260246

RESUMEN

Neural oscillations mediate the coordination of activity within and between brain networks, supporting cognition and behaviour. How these processes develop throughout childhood is not only an important neuroscientific question but could also shed light on the mechanisms underlying neurological and psychiatric disorders. However, measuring the neurodevelopmental trajectory of oscillations has been hampered by confounds from instrumentation. In this paper, we investigate the suitability of a disruptive new imaging platform - Optically Pumped Magnetometer-based magnetoencephalography (OPM-MEG) - to study oscillations during brain development. We show how a unique 192-channel OPM-MEG device, which is adaptable to head size and robust to participant movement, can be used to collect high-fidelity electrophysiological data in individuals aged between 2 and 34 years. Data were collected during a somatosensory task, and we measured both stimulus-induced modulation of beta oscillations in sensory cortex, and whole-brain connectivity, showing that both modulate significantly with age. Moreover, we show that pan-spectral bursts of electrophysiological activity drive task-induced beta modulation, and that their probability of occurrence and spectral content change with age. Our results offer new insights into the developmental trajectory of beta oscillations and provide clear evidence that OPM-MEG is an ideal platform for studying electrophysiology in neurodevelopment.

6.
Eye (Lond) ; 38(7): 1386-1389, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38200322

RESUMEN

BACKGROUND: Cataract surgical safety has improved over recent decades, with endophthalmitis rates before 2006 typically 0.13-0.15% compared with the most recent UK national estimate of 0.02%. There remains, however, substantial variation in reported rates from different centres. Due to the low event rate, this disparity may not be noticed and opportunities to improve therefore be missed. We propose a method of monitoring post-cataract endophthalmitis rates that would help centres with higher rates identify this. METHODS: A statistical tool, available to download or use online, permits comparison of local endophthalmitis rate with the estimated UK rate of 0.02%. Centres are encouraged to maintain a register of endophthalmitis cases, and when the number reaches a threshold (X cases), either in a certain time period or in a fixed number of procedures, then the centre can consider itself as an outlier and trigger local investigations to improve infection control. RESULTS: Example outputs are offered, such as for a unit doing 5000 cataracts annually, a value of X is suggested such that the third case of endophthalmitis (X = 3) in a 12-month period would give 85% confidence, the fourth case 90% confidence and the fifth case 95% confidence that the true endophthalmitis rate for that unit was higher than the national average. CONCLUSIONS: This statistical tool provides a basis for units to set a threshold number of cases of endophthalmitis within a given period that would trigger local processes, thus helping inform local monitoring processes for this rare but potentially catastrophic complication of cataract surgery.


Asunto(s)
Extracción de Catarata , Bases de Datos Factuales , Endoftalmitis , Oftalmología , Humanos , Endoftalmitis/epidemiología , Endoftalmitis/prevención & control , Endoftalmitis/etiología , Extracción de Catarata/efectos adversos , Extracción de Catarata/estadística & datos numéricos , Reino Unido/epidemiología , Oftalmología/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Sociedades Médicas
7.
Innovations (Phila) ; 19(1): 39-45, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38087894

RESUMEN

OBJECTIVE: Upper hemisternotomy (UHS) for supracoronary ascending aorta replacement (scAAR) with concomitant aortic valve replacement (AVR) results in less trauma and potentially faster convalescence compared with full sternotomy (FS). Direct head-to-head studies are lacking. We compared a group of UHS patients with a matched group of FS patients undergoing scAAR and AVR. METHODS: There were 198 patients who underwent scAAR and AVR procedures by a single surgeon between 1999 and 2020. After matching 6 preoperative characteristics, there were 50 UHS and 50 FS patients. Patients who required acute type A aortic dissection repair, reoperations, concomitant procedures, or hypothermic circulatory arrest were excluded. RESULTS: In the matched sample, the hospital mortality rate was 1% (1 of 100). The median cardiopulmonary bypass time was 150 (interquartile range [IQR], 131 to 172) min and 164.5 (IQR, 138 to 190) min, respectively, for the UHS and FS groups (P = 0.08). The median aortic cross-clamp time was 121 (IQR, 107 to 139) min during UHS and 131 (IQR, 115 to 159) min during FS (P = 0.05). The median ventilation time was 7 (IQR, 3 to 14) h versus 17 (IQR, 10 to 24) h, respectively, after UHS and FS (P = 0.005). The median hospital length of stay was 7 (IQR, 6 to 9) days after UHS and 8 (IQR, 7 to 11) days after FS (P = 0.05). CONCLUSIONS: The low morbidity and mortality support the wider use of UHS for scAAR and AVR in appropriately selected patients. Larger studies are needed to confirm these initial findings.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Válvula Aórtica/cirugía , Esternotomía/métodos , Aorta Torácica/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos
8.
J Immigr Minor Health ; 26(2): 385-394, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37612453

RESUMEN

Cancer screening rates among immigrant and refugee populations in high income countries is significantly lower than native born populations. The objective of this study is to systematically review the effectiveness of interventions to improve screening adherence for breast, cervical and colorectal cancer among Somali immigrants. A literature search was conducted for the years 2000-2021 and eight studies met eligibility criteria. The following intervention components were found to increase adherence to cervical cancer screening: home HPV test, educational workshop for women and education for general practitioners. A patient navigator intervention was found to increase screening for breast cancer. Educational workshops motivated or increased knowledge regarding cancer screening for breast, cervical and colorectal cancer. However, most of the studies had limitations due to methodology with potential for introduction of bias. Therefore, future studies comparing effectiveness of specific intervention components to reduce disparities in cancer screening among Somali immigrants and refugees are encouraged.


Asunto(s)
Neoplasias Colorrectales , Emigrantes e Inmigrantes , Neoplasias del Cuello Uterino , Humanos , Femenino , Detección Precoz del Cáncer/métodos , Somalia , Neoplasias del Cuello Uterino/diagnóstico , Europa (Continente)
9.
J Pharm Technol ; 39(6): 281-285, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37974597

RESUMEN

Background: Pharmacist order verification is a critical step in ensuring medication safety for patients. While the second pharmacist verification (SPV) before dispensing anticancer therapies has been a longstanding practice, its continued necessity in the context of modern electronic health systems lacks robust evidence. Objective: This study aimed to assess the frequency of interventions performed by a second pharmacist to determine the ongoing effectiveness of the SPV process. Methods: This retrospective chart review was conducted at the Mayo Clinic, encompassing all anticancer therapy orders that necessitated an SPV. The study period extended from January 1, 2019, to June 30, 2021, and included inpatient and outpatient anticancer orders. The quantification and reporting of alterations made to discrete order fields subsequent to initial pharmacist verification of clinical significance were performed, utilizing the total number of anticancer therapy orders as the denominator. Results: Approximately 300 000 anticancer therapy orders were screened for inclusion criteria and 2.6% (N = 7634) of orders were modified on the SPV. Most changes were in the categories of rate (N = 1962), order start time (N = 1219), and pharmacy communication note (N = 777). Dosing changes greater than 10% accounted for 0.03% (N = 99) of the orders, with 10 anticancer therapies responsible for more than 50% of these changes. Conclusion and relevance: This study represents the largest report on the impact of SPV in a modern era. Our results suggest the SPV may be valuable for a small proportion of chemotherapy orders but raises questions about the necessity for broad application of this practice.

11.
Materials (Basel) ; 16(15)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37570104

RESUMEN

The characterization of silicon carbide (SiC) by specific electrical atomic force microscopy (AFM) modes is highly appreciated for revealing its structure and properties at a nanoscale. However, during the conductive AFM (C-AFM) measurements, the strong electric field that builds up around and below the AFM conductive tip in ambient atmosphere may lead to a direct anodic oxidation of the SiC surface due to the formation of a water nanomeniscus. In this paper, the underlying effects of the anodization are experimentally investigated for SiC multilayers with different doping levels by studying gradual SiC epitaxial-doped layers with nitrogen (N) from 5 × 1017 to 1019 at/cm3. The presence of the water nanomeniscus is probed by the AFM and analyzed with the force-distance curve when a negative bias is applied to the AFM tip. From the water meniscus breakup distance measured without and with polarization, the water meniscus volume is increased by a factor of three under polarization. AFM experimental results are supported by electrostatic modeling to study oxide growth. By taking into account the presence of the water nanomeniscus, the surface oxide layer and the SiC doping level, a 2D-axisymmetric finite element model is developed to calculate the electric field distribution nearby the tip contact and the current distributions at the nanocontact. The results demonstrate that the anodization occurred for the conductive regime in which the current depends strongly to the doping; its threshold value is 7 × 1018 at/cm3 for anodization. Finally, the characterization of a classical planar SiC-MOSFET by C-AFM is examined. Results reveal the local oxidation mechanism of the SiC material at the surface of the MOSFET structure. AFM topographies after successive C-AFM measurements show that the local oxide created by anodization is located on both sides of the MOS channel; these areas are the locations of the highly n-type-doped zones. A selective wet chemical etching confirms that the oxide induced by local anodic oxidation is a SiOCH layer.

12.
Sensors (Basel) ; 23(12)2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37420622

RESUMEN

The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substrates remain poorly understood. Hyperscanning employs functional neuroimaging to simultaneously assess brain activity in two individuals and offers the best means to understand the neural basis of social interaction. However, present technologies are limited, either by poor performance (low spatial/temporal precision) or an unnatural scanning environment (claustrophobic scanners, with interactions via video). Here, we describe hyperscanning using wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs). We demonstrate our approach by simultaneously measuring brain activity in two subjects undertaking two separate tasks-an interactive touching task and a ball game. Despite large and unpredictable subject motion, sensorimotor brain activity was delineated clearly, and the correlation of the envelope of neuronal oscillations between the two subjects was demonstrated. Our results show that unlike existing modalities, OPM-MEG combines high-fidelity data acquisition and a naturalistic setting and thus presents significant potential to investigate neural correlates of social interaction.


Asunto(s)
Magnetoencefalografía , Dispositivos Electrónicos Vestibles , Humanos , Magnetoencefalografía/métodos , Neuroimagen Funcional , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología
14.
J Natl Cancer Inst ; 115(9): 1011-1019, 2023 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-37289549

RESUMEN

BACKGROUND: Early-stage breast cancer is among the most common cancer diagnoses. Adjuvant radiotherapy is an essential component of breast-conserving therapy, and several options exist for tailoring its extent and duration. This study assesses the comparative effectiveness of partial-breast irradiation (PBI) compared with whole-breast irradiation (WBI). METHODS: A systematic review was completed to identify relevant randomized clinical trials and comparative observational studies. Independent reviewers working in pairs selected studies and extracted data. Randomized trial results were pooled using a random effects model. Prespecified main outcomes were ipsilateral breast recurrence (IBR), cosmesis, and adverse events (AEs). RESULTS: Fourteen randomized clinical trials and 6 comparative observational studies with 17 234 patients evaluated the comparative effectiveness of PBI. PBI was not statistically significantly different from WBI for IBR at 5 years (RR = 1.34, 95% CI = 0.83 to 2.18; high strength of evidence [SOE]) and 10 years (RR = 1.29, 95% CI = 0.87 to 1.91; high SOE). Evidence for cosmetic outcomes was insufficient. Statistically significantly fewer acute AEs were reported with PBI compared with WBI, with no statistically significant difference in late AEs. Data from subgroups according to patient, tumor, and treatment characteristics were insufficient. Intraoperative radiotherapy was associated with higher IBR at 5, 10, and over than 10 years (high SOE) compared with WBI. CONCLUSIONS: Ipsilateral breast recurrence was not statistically significantly different between PBI and WBI. Acute AEs were less frequent with PBI. This evidence supports the effectiveness of PBI among selected patients with early-stage, favorable-risk breast cancer who are similar to those represented in the included studies.


Asunto(s)
Neoplasias de la Mama , Mama , Humanos , Femenino , Mama/patología , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/patología , Mastectomía Segmentaria , Radioterapia Adyuvante/efectos adversos
15.
Neuroimage ; 274: 120157, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37149237

RESUMEN

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements.


Asunto(s)
Magnetoencefalografía , Dispositivos Electrónicos Vestibles , Humanos , Magnetoencefalografía/métodos , Movimiento , Campos Magnéticos , Fenómenos Electromagnéticos , Encéfalo/fisiología
16.
J Clin Oncol ; 41(21): 3712-3723, 2023 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-37192435

RESUMEN

PURPOSE: Compared with people living without HIV (PWOH), people living with HIV (PWH) and cancer have traditionally been excluded from immune checkpoint inhibitor (ICI) trials. Furthermore, there is a paucity of real-world data on the use of ICIs in PWH and cancer. METHODS: This retrospective study included PWH treated with anti-PD-1- or anti-PD-L1-based therapies for advanced cancers. Kaplan-Meier method was used to estimate overall survival (OS) and progression-free survival (PFS). Objective response rates (ORRs) were measured per RECIST 1.1 or other tumor-specific criteria, whenever feasible. Restricted mean survival time (RMST) was used to compare OS and PFS between matched PWH and PWOH with metastatic NSCLC (mNSCLC). RESULTS: Among 390 PWH, median age was 58 years, 85% (n = 331) were males, 36% (n = 138) were Black; 70% (n = 274) received anti-PD-1/anti-PD-L1 monotherapy. Most common cancers were NSCLC (28%, n = 111), hepatocellular carcinoma ([HCC]; 11%, n = 44), and head and neck squamous cell carcinoma (HNSCC; 10%, n = 39). Seventy percent (152/216) had CD4+ T cell counts ≥200 cells/µL, and 94% (179/190) had HIV viral load <400 copies/mL. Twenty percent (79/390) had any grade immune-related adverse events (irAEs) and 7.7% (30/390) had grade ≥3 irAEs. ORRs were 69% (nonmelanoma skin cancer), 31% (NSCLC), 16% (HCC), and 11% (HNSCC). In the matched mNSCLC cohort (61 PWH v 110 PWOH), 20% (12/61) PWH and 22% (24/110) PWOH had irAEs. Adjusted 42-month RMST difference was -0.06 months (95% CI, -5.49 to 5.37; P = .98) for PFS and 2.23 months (95% CI, -4.02 to 8.48; P = .48) for OS. CONCLUSION: Among PWH, ICIs demonstrated differential activity across cancer types with no excess toxicity. Safety and activity of ICIs were similar between matched cohorts of PWH and PWOH with mNSCLC.


Asunto(s)
Carcinoma Hepatocelular , Carcinoma de Pulmón de Células no Pequeñas , Infecciones por VIH , Neoplasias de Cabeza y Cuello , Neoplasias Hepáticas , Neoplasias Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Femenino , Inhibidores de Puntos de Control Inmunológico/efectos adversos , Estudios Retrospectivos , Carcinoma de Células Escamosas de Cabeza y Cuello , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Neoplasias Pulmonares/tratamiento farmacológico , Infecciones por VIH/tratamiento farmacológico
17.
Biomedicines ; 11(3)2023 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-36979929

RESUMEN

OBJECTIVE: This study is a comprehensive review of the clinical pharmacology, pharmacokinetics, efficacy, safety, and clinical applicability of amivantamab-vmjw for metastatic non-small cell lung cancer (NSCLC) with epidermal growth factor receptor (EGFR) exon 20 insertion (exon20ins) mutation. DATA SYNTHESIS: The literature search to identify clinical trials returned only the CHRYSALIS phase 1 study. In a phase I trial, amivantamab-vmjw was associated with an overall response rate (ORR) of 40% (95% CI, 29-51) in the EGFR exon20ins NSCLC patient population (n = 81) after platinum-based chemotherapy. There were 3 complete responses (CRs) and 29 partial responses (PRs). The median duration of response (DOR) was 11.1 months (95% CI, 6.9-not reached; NR). The median progression-free survival (PFS) was 8.3 months (95% CI, 6.5-10.9), and overall survival (OS) was 22.8 months (95% CI, 14.6-NR). APPLICATION TO CLINICAL PRACTICE: This review summarizes the pharmacology, clinical evidence, and use of amivantamab-vmjw for patients with locally advanced or metastatic NSCLC with EGFR exon20ins mutation. CONCLUSION: The FDA approval of amivantamab-vmjw, the first bispecific antibody to target the exon20ins mutation, represents an important advancement in the treatment of patients with NSCLC with limited effective treatment options. The initial findings of the CHRYSALIS trial demonstrate an overall tumor response benefit with an acceptable safety profile.

18.
Neuroimage ; 271: 120024, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36918138

RESUMEN

Optically pumped magnetometers (OPMs) are an emerging lightweight and compact sensor that can measure magnetic fields generated by the human brain. OPMs enable construction of wearable magnetoencephalography (MEG) systems, which offer advantages over conventional instrumentation. However, when trying to measure signals at low frequency, higher levels of inherent sensor noise, magnetic interference and movement artefact introduce a significant challenge. Accurate characterisation of low frequency brain signals is important for neuroscientific, clinical, and paediatric MEG applications and consequently, demonstrating the viability of OPMs in this area is critical. Here, we undertake measurement of theta band (4-8 Hz) neural oscillations and contrast a newly developed 174 channel triaxial wearable OPM-MEG system with conventional (cryogenic-MEG) instrumentation. Our results show that visual steady state responses at 4 Hz, 6 Hz and 8 Hz can be recorded using OPM-MEG with a signal-to-noise ratio (SNR) that is not significantly different to conventional MEG. Moreover, we measure frontal midline theta oscillations during a 2-back working memory task, again demonstrating comparable SNR for both systems. We show that individual differences in both the amplitude and spatial signature of induced frontal-midline theta responses are maintained across systems. Finally, we show that our OPM-MEG results could not have been achieved without a triaxial sensor array, or the use of postprocessing techniques. Our results demonstrate the viability of OPMs for characterising theta oscillations and add weight to the argument that OPMs can replace cryogenic sensors as the fundamental building block of MEG systems.


Asunto(s)
Encéfalo , Magnetoencefalografía , Humanos , Niño , Magnetoencefalografía/métodos , Encéfalo/fisiología , Campos Magnéticos , Relación Señal-Ruido
19.
Rev. bras. cir. cardiovasc ; 38(1): 71-78, Jan.-Feb. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1423079

RESUMEN

ABSTRACT Introduction: The Impella ventricular support system is a device that can be inserted percutaneously or directly across the aortic valve to unload the left ventricle. The purpose of this study is to determine the role of Impella devices in patients with acute cardiogenic shock in the perioperative period of cardiac surgery. Methods: A retrospective single-surgeon review of 11 consecutive patients who underwent placement of Impella devices in the perioperative period of cardiac surgery was performed. Patient records were evaluated for demographics, indications for placement, and postoperative outcomes. Results: Impella devices were placed for refractory cardiogenic shock preoperatively in 6 patients, intraoperatively in 4 patients, and postoperatively as a rescue in 1 patient. Seven patients received Impella CP, 1 Impella RP, 1 Impella CP and RP, and 2 Impella 5.0. Additionally, 3 patients required preoperative venovenous extracorporeal membrane oxygenation (VV-ECMO), and 1 patient required intraoperative venoarterial extracorporeal membrane oxygenation (VA-ECMO). All Impella devices were removed 1 to 28 days after implantation. Length of stay in the intensive care unit stay ranged from 2 to 53 days (average 23.9±14.6). The 30-day and 1-year mortality were 0%. Ten of 11 patients were alive at 2 years. Also, 1 patient died 18 months after surgery from complications of coronavirus disease (Covid-19). Device-related complications included varying degrees> of hemolysis in 8 patients (73%) and device malfunction in 1 patient (9%). Conclusions: The Impella ventricular support system can be combined with other mechanical support devices for additional hemodynamic support. All patients demonstrated myocardial recovery with no deaths in the perioperative period and in 1-year of follow-up. Larger studies are necessary to validate these findings.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA