Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Sep Sci ; 40(15): 3120-3129, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28618213

RESUMEN

A novel analytical method for the simultaneous determination of the concentration of sildenafil and its five analogues in dietary supplements using solid-phase extraction assisted reversed-phase dispersive liquid-liquid microextraction based on solidification of floating organic droplet combined with ion-pairing liquid chromatography with an ultraviolet detector was developed. Parameters that affect extraction efficiency were systematically investigated, including the type of solid-phase extraction cartridge, pH of the extraction environment, and the type and volume of extraction and dispersive solvent. The method linearity was in the range of 5.0-100 ng/mL for sildenafil, homosildenafil, udenafil, benzylsildenafil, and thiosildenafil and 10-100 ng/mL for acetildenafil. The coefficients of determination were ≥0.996 for all regression curves. The sensitivity values expressed as limit of detection were between 2.5 and 7.5 ng/mL. Furthermore, intraday and interday precisions expressed as relative standard deviations were less than 5.7 and 9.9%, respectively. The proposed method was successfully applied to the analysis of sildenafil and its five analogues in complex dietary supplements.


Asunto(s)
Suplementos Dietéticos/análisis , Microextracción en Fase Líquida , Citrato de Sildenafil/análogos & derivados , Citrato de Sildenafil/análisis , Extracción en Fase Sólida , Límite de Detección
2.
J Pharm Biomed Anal ; 51(4): 973-8, 2010 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-20004074

RESUMEN

Recently, charged aerosol detection (CAD), a new kind of universal detection method, has been widely employed in the HPLC system. In the present study, four kinds of anti-diabetic drug standards, glipizide, gliclazide, glibenclamide and glimepiride were determined by ultraviolet (UV) detection, evaporative light scattering detection (ELSD) and the aforementioned CAD. The results were compared with reference to linearity, accuracy, precision and limit of detection (LOD). All of the experiments were performed on a reverse phase column with water and acetonitrile as the mobile phase. Separations were achieved under the same chromatographic conditions for each detection method. As a result, CAD generated nearly uniform responses compared with UV detection and ELSD. It showed the best accuracy and LOD among 3 detectors and had similar precision with UV detection at higher concentrations while UV detection showed a better precision at lower concentrations than did CAD or ELSD. The LOD of CAD, in fact, can be up to two times higher than that of ELSD. The UV and ELSD linearity was satisfactory at R(2)>0.99, though in the case of CAD, a log-log transformation was needed. The proposed methods were also applied to the real anti-diabetic drugs and diabetes-related dietary supplements.


Asunto(s)
Cromatografía Líquida de Alta Presión , Cromatografía de Fase Inversa , Hipoglucemiantes/análisis , Luz , Dispersión de Radiación , Espectrofotometría Ultravioleta , Aerosoles , Gliclazida/análisis , Glipizida/análisis , Gliburida/análisis , Reproducibilidad de los Resultados , Compuestos de Sulfonilurea/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...