Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Clin J Sport Med ; 34(3): 247-255, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38180057

RESUMEN

OBJECTIVE: To determine whether an investigational head-neck cooling device, Pro2cool, can better reduce symptom severity compared with standard postconcussion care in early adolescent athletes after a sports-related concussion. DESIGN: Prospective, longitudinal, randomized trial design conducted over a 28-day period. SETTING: Six pediatric medical centers in Ohio and Michigan. PARTICIPANTS: The study enrolled 167 male and female 12- to 19-year-old athletes who experienced a sports-related concussion within 8 days of study enrollment and registering a Sports Concussion Assessment Tool 5 (SCAT5) composite score >7. INTERVENTIONS: Pro2cool, an investigational head-neck cooling therapy device, was applied at 2 postinjury time points compared with postconcussion standard of care only. MAIN OUTCOME MEASURES: Baseline SCAT5 composite symptom severity scores were determined for all subjects. Sports Concussion Assessment Tool 5 scores for concussed athletes receiving cooling treatment were analyzed across 6 independent postenrollment time points compared with subjects who did not receive cooling therapy and only standard care. Adverse reactions and participate demographics were also compared. RESULTS: Athletes who received Pro2cool cooling therapy (n = 79) experienced a 14.4% greater reduction in SCAT5 symptom severity scores at the initial visit posttreatment, a 25.5% greater reduction at the 72-hour visit posttreatment, and a 3.4% greater reduction at the 10-day visit compared with subjects receiving only standard care (n = 88). Overall, 36 adverse events (increased blood pressure, decreased pulse, and dizziness) were reported, with 13 events associated with the device, of which 3 were classified as moderate in severity. CONCLUSIONS: This study demonstrates the efficacy and safety of head and neck cooling for the management of concussion symptoms in adolescent athletes of an age group for which little to no prior data are available.


Asunto(s)
Traumatismos en Atletas , Conmoción Encefálica , Hipotermia Inducida , Humanos , Masculino , Adolescente , Femenino , Conmoción Encefálica/terapia , Conmoción Encefálica/diagnóstico , Traumatismos en Atletas/terapia , Traumatismos en Atletas/diagnóstico , Estudios Prospectivos , Hipotermia Inducida/instrumentación , Hipotermia Inducida/métodos , Niño , Adulto Joven , Estudios Longitudinales , Carga Sintomática
2.
Cardiol Young ; 33(5): 754-759, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35673794

RESUMEN

BACKGROUND: Electroanatomic mapping systems are increasingly used during ablations to decrease the need for fluoroscopy and therefore radiation exposure. For left-sided arrhythmias, transseptal puncture is a common procedure performed to gain access to the left side of the heart. We aimed to demonstrate the radiation exposure associated with transseptal puncture. METHODS: Data were retrospectively collected from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry. Patients with left-sided accessory pathway-mediated tachycardia, with a structurally normal heart, who had a transseptal puncture, and were under 22 years of age were included. Those with previous ablations, concurrent diagnostic or interventional catheterisation, and missing data for fluoroscopy use or procedural outcomes were excluded. Patients with a patent foramen ovale who did not have a transseptal puncture were selected as the control group using the same criteria. Procedural outcomes were compared between the two groups. RESULTS: There were 284 patients in the transseptal puncture group and 70 in the patent foramen ovale group. The transseptal puncture group had a significantly higher mean procedure time (158.8 versus 131.4 minutes, p = 0.002), rate of fluoroscopy use (38% versus 7%, p < 0.001), and mean fluoroscopy time (2.4 versus 0.6 minutes, p < 0.001). The acute success and complication rates were similar. CONCLUSIONS: Performing transseptal puncture remains a common reason to utilise fluoroscopy in the era of non-fluoroscopic ablation. Better tools are needed to make non-fluoroscopic transseptal puncture more feasible.


Asunto(s)
Ablación por Catéter , Foramen Oval Permeable , Exposición a la Radiación , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Punciones/métodos , Ablación por Catéter/métodos
3.
Cardiol Young ; 32(10): 1580-1584, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34789361

RESUMEN

BACKGROUND: Patients with CHD can be exposed to high levels of cumulative ionising radiation. Utilisation of electroanatomic mapping during catheter ablation leads to reduced radiation exposure in the general population but has not been well studied in patients with CHD. This study evaluated the radiation sparing benefit of using three-dimensional mapping in patients with CHD. METHODS: Data were retrospectively collected from the Catheter Ablation with Reduction or Elimination of Fluoroscopy multi-institutional registry. Patients with CHD were selected. Those with previous ablations, concurrent diagnostic or interventional catheterisation and unknown arrhythmogenic foci were excluded. The control cohort was matched for operating physician, arrhythmia mechanism, arrhythmia location, weight and age. The procedure time, rate of fluoroscopy use, fluoroscopy time, procedural success, complications, and distribution of procedures per year were compared between the two groups. RESULTS: Fifty-six patients with congenital heart disease and 56 matched patients without CHD were included. The mean total procedure time was significantly higher in patients with CHD (212.6 versus 169.5 minutes, p = 0.003). Their median total fluoroscopy time was 4.4 minutes (compared to 1.8 minutes), and their rate of fluoroscopy use was 23% (compared to 13%). The acute success and minor complication rates were similar and no major complications occurred. CONCLUSIONS: With the use of electroanatomic mapping during catheter ablation, fluoroscopy use can be reduced in patients with CHD. The majority of patients with CHD received zero fluoroscopy.


Asunto(s)
Ablación por Catéter , Exposición a la Radiación , Humanos , Mapeo del Potencial de Superficie Corporal/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Exposición a la Radiación/prevención & control , Fluoroscopía/métodos , Ablación por Catéter/métodos , Arritmias Cardíacas/epidemiología
4.
Cardiol Young ; 31(12): 1923-1928, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33766172

RESUMEN

BACKGROUND: Catheter ablation is a safe and effective therapy for the treatment of supraventricular tachycardia in children. Current improvements in technology have allowed progressive reduction in radiation exposure associated with the procedure. To assess the impact of three-dimensional mapping, we compared acute procedural results collected from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry to published results from the Prospective Assessment after Pediatric Cardiac Ablation study. METHODS: Inclusion and exclusion criteria from the Prospective Assessment after Pediatric Cardiac Ablation study were used as guidelines to select patient data from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry to compare acute procedural outcomes between cohorts. Outcomes assessed include procedural and fluoroscopy exposure times, success rates of procedure, and complications. RESULTS: In 786 ablation procedures, targeting 498 accessory pathways and 288 atrioventricular nodal reentrant tachycardia substrates, average procedural time (156.5 versus 206.7 minutes, p < 0.01), and fluoroscopy time (1.2 versus 38.3 minutes, p < 0.01) were significantly shorter in the study group. Success rates for the various substrates were similar except for manifest accessory pathways which had a significantly higher success rate in the study group (96.4% versus 93.0%, p < 0.01). Major complication rates were significantly lower in the study group (0.3% versus 1.6%, p < 0.01). CONCLUSIONS: In a large, multicentre study, three-dimensional systems show favourable improvements in clinical outcomes in children undergoing catheter ablation of supraventricular tachycardia compared to the traditional fluoroscopic approach. Further improvements are anticipated as technology advances.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Niño , Fluoroscopía , Humanos , Estudios Prospectivos , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA