Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Philos Trans A Math Phys Eng Sci ; 374(2064): 20150045, 2016 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-26903100

RESUMEN

We describe the design, construction, calibration and use of a near-infrared thermodynamic radiation thermometer to measure blackbodies from 400 K to 1300 K. The motivation for this work is the pending redefinition of the kelvin and the need for direct, thermodynamic temperature measurements of the fixed-point blackbodies presently used in the realization of the temperature scale. The challenges of accurately measuring Planck radiances which vary greatly in radiance level and spectral shape are discussed. Methods to characterize the components used in the radiation thermometer design are described. The use of this radiation thermometer as a relative primary thermometer and the resulting residuals are shown. We describe radiometric calibration procedures for using the radiation thermometer as an absolute primary thermometer. Preliminary data showing the initial radiometric calibration steps are discussed.

2.
Appl Opt ; 49(10): 1859-64, 2010 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-20357870

RESUMEN

Results are presented for modeling of the shape of the internal quantum efficiency (IQE) versus wavelength for silicon photodiodes in the 400 nm to 900 nm wavelength range. The IQE data are based on measurements of the external quantum efficiencies of three transmission optical trap detectors using an extensive set of laser wavelengths, along with the transmittance of the traps. We find that a simplified version of a previously reported IQE model fits the data with an accuracy of better than 0.01%. These results provide an important validation of the National Institute of Standards and Technology (NIST) spectral radiant power responsivity scale disseminated through the NIST Spectral Comparator Facility, as well as those scales disseminated by other National Metrology Institutes who have employed the same model.

3.
Ann Hum Genet ; 71(Pt 3): 308-11, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17166181

RESUMEN

Interferon regulatory factor 5 (IRF5) belongs to a family of transcription factors that control the transactivation of type I interferon system-related genes, as well as the expression of several other genes involved in immune response, cell signalling, cell cycle control and apoptosis. Two recent studies reported a significant association between the IRF5/rs2004640 T allele and systemic lupus erythematosus (SLE). The purpose of this study was to determine whether the reported rs2004640 T allele association could be replicated in our independent SLE case-control sample. We genotyped DNA samples from 370 white SLE-affected female subjects and 462 white healthy female controls using the TaqMan Assay-on-Demand for rs2004640, and performed a case-control genetic association analysis. Frequency of the rs2004640 T allele was significantly higher in cases than in controls (56.5% vs. 50%; P= 0.008). The odds ratio for T allele carriers was 1.68 (95% CI: 1.20 - 2.34; P= 0.003). Our results in an independent case-control sample confirm the robust association of the IRF5/rs2004640 T allele with SLE risk, and further support the relevance of the type I interferon system in the pathogenesis of SLE and autoimmunity.


Asunto(s)
Factores Reguladores del Interferón/genética , Lupus Eritematoso Sistémico/genética , Lupus Eritematoso Sistémico/inmunología , Adolescente , Adulto , Alelos , Empalme Alternativo , Estudios de Casos y Controles , Estudios de Cohortes , Femenino , Variación Genética , Humanos , Persona de Mediana Edad , Polimorfismo de Nucleótido Simple , Factores de Riesgo
4.
J Res Natl Inst Stand Technol ; 105(5): 689-700, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-27551631

RESUMEN

A cryogenic radiometer-based system was constructed at the National Institute of Standards and Technology for absolute radiometric measurements to improve detector spectral power responsivity scales in the wavelength range from 900 nm to 1800 nm. In addition to the liquid-helium-cooled cryogenic radiometer, the system consists of a 100 W quartz-tungsten-halogen lamp light source and a 1 m single-grating monochromator for wavelength selection. The system was characterized and the uncertainty in spectral power responsivity measurements evaluated. A variety of photodetectors, including indium gallium arsenide photodiodes (InGaAs), germanium (Ge) photodiodes, and pyroelectric detectors, were subsequently calibrated. Over most of the spectral range, the spectral power responsivity of the photodetectors can be measured with a combined relative standard uncertainty of 0.4 % or less. This is more than a factor of two smaller than our previous capabilities, and represents a significant improvement in the near infrared (NIR) spectral power responsivity scale maintained at NIST. We discuss the characterization of the monochromator-based system and present results of photodetector spectral power responsivity calibrations.

5.
Appl Opt ; 38(1): 18-28, 1999 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-18305582

RESUMEN

The combination of a cryogenic radiometer and synchrotron radiation enables detector scale realization in spectral regions that are otherwise difficult to access. Cryogenic radiometry is the most accurate primary detector-based standard available to date, and synchrotron radiation gives a unique broadband and continuous spectrum that extends from x ray to far IR. We describe a new cryogenic radiometer-based UV radiometry facility at the Synchrotron Ultraviolet Radiation Facility II at the National Institute of Standards and Technology. The facility is designed to perform a variety of detector and optical materials characterizations. The facility combines a high-throughput, normal incidence monochromator with an absolute cryogenic radiometer optimized for UV measurements to provide absolute radiometric measurements in the spectral range from 125 nm to approximately 320 nm. We discuss results on photodetector characterizations, including absolute spectroradiometric calibration, spatial responsivity mapping, spectroreflectance, and internal quantum efficiency. In addition, such characterizations are used to study UV radiation damage in photodetectors that can shed light on the mechanism of the damage process. Examples are also given for UV optical materials characterization.

6.
Cancer Res ; 47(13): 3577-83, 1987 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-3555775

RESUMEN

Murine variable and human constant region exons were fused to produce "chimeric" immunoglobulin gamma and kappa genes. These constructs were cotransfected into murine myeloma cells which then produced and secreted intact, functional antibody. Cells secreting the chimeric antibody were introduced into mice. The engineered immunoglobulin was subsequently harvested from ascites fluid and was purified by affinity chromatography. Its immunological properties were compared to those of the parental murine monoclonal (B6.2), which exhibits specificity for human breast, lung, and colon carcinoma cells. Competitive binding, immunofluorescent cell staining, and analysis of immunoprecipitated antigen gave similar results for the chimeric and murine B6.2. The biodistribution of chimeric and murine B6.2 after injection into mice bearing human tumors was found to be identical. These results suggest that murine/human chimeric antibodies may be viable clinical replacements for murine monoclonals with the potential for better immunological tolerance and pharmacological efficacy.


Asunto(s)
Anticuerpos Monoclonales/genética , Anticuerpos Antineoplásicos/genética , Animales , Anticuerpos Monoclonales/inmunología , Anticuerpos Antineoplásicos/inmunología , Especificidad de Anticuerpos , Antígenos de Neoplasias/inmunología , Unión Competitiva , Quimera , Técnica del Anticuerpo Fluorescente , Ingeniería Genética , Humanos , Hibridomas , Ratones , Trasplante de Neoplasias , Neoplasias Experimentales/diagnóstico por imagen , Cintigrafía , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...