Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Lung India ; 40(4): 368-400, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37417095

RESUMEN

Over the past decade, endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has become an indispensable tool in the diagnostic armamentarium of the pulmonologist. As the expertise with EBUS-TBNA has evolved and several innovations have occurred, the indications for its use have expanded. However, several aspects of EBUS-TBNA are still not standardized. Hence, evidence-based guidelines are needed to optimize the diagnostic yield and safety of EBUS-TBNA. For this purpose, a working group of experts from India was constituted. A detailed and systematic search was performed to extract relevant literature pertaining to various aspects of EBUS-TBNA. The modified GRADE system was used for evaluating the level of evidence and assigning the strength of recommendations. The final recommendations were framed with the consensus of the working group after several rounds of online discussions and a two-day in-person meeting. These guidelines provide evidence-based recommendations encompassing indications of EBUS-TBNA, pre-procedure evaluation, sedation and anesthesia, technical and procedural aspects, sample processing, EBUS-TBNA in special situations, and training for EBUS-TBNA.

2.
Pediatr Pulmonol ; 58(9): 2670-2674, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37265423

RESUMEN

Foreign body (FB) aspiration is a potentially life-threatening accident in children. Traditionally, rigid bronchoscopy has been the procedure of choice for FB removal, however it may miss distally lodged FBs. We report two pediatric cases with distal impacted FBs that could not be retrieved by rigid bronchoscopy (RB) and were mobilised using Fogarty balloon followed by flexible bronchoscopic cryoextraction. The advantage of a cryoprobe is lower risk of fragmentation of FB that may occur with forceps. Cryoextraction is particularly advantageous for removing water-containing FBs. In both patients, FB was removed more than 2 weeks following aspiration, leading to the formation of granulation tissue around the FB, which considerably hampered the process. Using a laryngeal mask airway to secure the airway, FB removal by flexible bronchoscopy may be a safe and effective technique in skilled hands, especially for FBs impacted in distal airways with granulation tissue where RB fails.


Asunto(s)
Bronquios , Cuerpos Extraños , Niño , Humanos , Broncoscopía/métodos , Tejido de Granulación , Cuerpos Extraños/cirugía , Estudios Retrospectivos
3.
Breathe (Sheff) ; 13(3): 217-224, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28894482

RESUMEN

Can you diagnose this middle-aged man with generalised weakness and dyspnoea? http://ow.ly/mSuQ30dxQ5o.

4.
Breathe (Sheff) ; 12(3): e64-e74, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28210311

RESUMEN

A rare cause for cough and fever http://ow.ly/d6zy301yYDJ.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...