Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Semin Ophthalmol ; : 1-12, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38643350

RESUMEN

Glaucoma is the leading cause of irreversible vision loss and comprises a group of chronic optic neuropathies characterized by progressive retinal ganglion cell (RGC) loss. Various etiologies, including impaired blood supply to the optic nerve, have been implicated for glaucoma pathogenesis. Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality for visualizing the ophthalmic microvasculature. Using blood flow as an intrinsic contrast agent, it distinguishes blood vessels from the surrounding tissue. Vessel density (VD) is mainly used as a metric for quantifying the ophthalmic microvasculature. The key anatomic regions for OCTA in glaucoma are the optic nerve head area including the peripapillary region, and the macular region. Specifically, VD of the superficial peripapillary and superficial macular microvasculature is reduced in glaucoma patients compared to unaffected subjects, and VD correlates with functional deficits measured by visual field (VF). This renders OCTA similar in diagnostic capabilities compared to structural retinal nerve fiber layer (RNFL) thickness measurements, especially in early glaucoma. Furthermore, in cases where RNFL thickness measurements are limited due to artifact or floor effect, OCTA technology can be used to evaluate and monitor glaucoma, such as in eyes with high myopia and eyes with advanced glaucoma. However, the clinical utility of OCTA in glaucoma management is limited due to the prevalence of imaging artifacts. Overall, OCTA can play a complementary role in structural OCT imaging and VF testing to aid in the diagnosis and monitoring of glaucoma.

2.
IEEE Trans Med Imaging ; 43(7): 2623-2633, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38478455

RESUMEN

Fairness (also known as equity interchangeably) in machine learning is important for societal well-being, but limited public datasets hinder its progress. Currently, no dedicated public medical datasets with imaging data for fairness learning are available, though underrepresented groups suffer from more health issues. To address this gap, we introduce Harvard Glaucoma Fairness (Harvard-GF), a retinal nerve disease dataset including 3,300 subjects with both 2D and 3D imaging data and balanced racial groups for glaucoma detection. Glaucoma is the leading cause of irreversible blindness globally with Blacks having doubled glaucoma prevalence than other races. We also propose a fair identity normalization (FIN) approach to equalize the feature importance between different identity groups. Our FIN approach is compared with various state-of-the-art fairness learning methods with superior performance in the racial, gender, and ethnicity fairness tasks with 2D and 3D imaging data, demonstrating the utilities of our dataset Harvard-GF for fairness learning. To facilitate fairness comparisons between different models, we propose an equity-scaled performance measure, which can be flexibly used to compare all kinds of performance metrics in the context of fairness. The dataset and code are publicly accessible via https://ophai.hms.harvard.edu/datasets/harvard-gf3300/.


Asunto(s)
Glaucoma , Aprendizaje Automático , Humanos , Glaucoma/diagnóstico por imagen , Masculino , Bases de Datos Factuales , Femenino , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Persona de Mediana Edad , Anciano
4.
Ophthalmol Glaucoma ; 7(2): 206-215, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37783274

RESUMEN

PURPOSE: To determine the clinical utility of OCT retinal nerve fiber layer (OCT RNFL) imaging for glaucoma evaluation in patients with Boston keratoprosthesis type 1 (KPro) by investigating imaging artifacts. DESIGN: Case-control study. SUBJECTS: Patients with KPro and without KPro (controls) matched for age, gender, and glaucoma diagnosis. METHODS: The most recent Cirrus OCT RNFL scan from 1 eye was categorized as having good signal strength (SS; ≥ 6 out of 10) or poor SS (< 6). Those with good SS were analyzed by 2 independent reviewers for artifacts. Images with good SS and no artifacts affecting the scanning circle were considered useful for glaucoma evaluation. MAIN OUTCOME MEASURES: The incidence of poor SS and artifacts in OCT RNFL images; patient characteristics associated with useful scans. RESULTS: Sixty-five patients with KPro and 75 controls were included; 89.2% of KPro patients and 89.3% of control subjects had glaucoma (P = 0.98). Forty percent of KPro patients and 5.3% of controls had poor SS (P < 0.001). The proportion of images with either poor SS or artifacts was similar in KPro (76.9%) vs. controls (72.0%, P = 0.51). The most common artifacts in both groups were missing data (43.6%, 53.2%, respectively, P = 0.32) and motion artifact (25.6%, 19.7%, respectively, P = 0.47). Images were useful for glaucoma evaluation in 43.1% of KPro patients and in 69.3% of controls (P = 0.002). In the KPro group, patients with useful OCT scans, compared with those without, had better visual acuity (0.4 ± 0.3 vs. 0.9 ± 0.7 logarithm of the minimum angle of resolution, P = 0.004), and did not have congenital corneal pathologies (0.0% vs. 24.3%, P = 0.008). A multivariate analysis showed that KPro patients with older age had higher odds of useful OCT images (odds ratio, 1.05; P = 0.03). Among KPro patients with useful OCT scans, retinal nerve fiber layer thickness correlated with observed cup-to-disc ratio (Pearson correlation: r = -0.42, P = 0.03). CONCLUSIONS: The rate of OCT RNFL images with either poor signal strength or artifacts in the KPro and control population was comparable. In patients with KPro, where intraocular pressure measurements are difficult and glaucoma is highly prevalent and often severe, OCT RNFL imaging can be useful for glaucoma evaluation. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Enfermedades de la Córnea , Glaucoma , Humanos , Córnea/cirugía , Artefactos , Tomografía de Coherencia Óptica/métodos , Estudios de Casos y Controles , Prótesis e Implantes , Presión Intraocular , Células Ganglionares de la Retina/patología , Enfermedades de la Córnea/diagnóstico , Enfermedades de la Córnea/cirugía , Enfermedades de la Córnea/patología , Glaucoma/diagnóstico , Glaucoma/cirugía , Glaucoma/patología , Fibras Nerviosas/patología
5.
J Glaucoma ; 33(4): 254-261, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38031290

RESUMEN

PRCIS: Using a large data set, we showed structural and functional differences between primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG). Primary angle closure glaucoma has relative structural preservation and worse functional loss inferiorly. PURPOSE: To identify structural and functional differences in PACG and POAG. MATERIALS AND METHODS: In this large cross-sectional study, differences in structural and functional damage were assessed among patients with POAG and PACG with optical coherence tomography and reliable visual field testing. RESULTS: In all, 283 patients with PACG and 4110 patients with POAG were included. Despite similar mean deviation on visual fields (mean [SD] -7.73 [7.92] vs. -7.53 [6.90] dB, P =0.72), patients with PACG had thicker global retinal nerve fiber layer (RNFL), smaller cup volume, smaller cup-to-disc ratio, and larger rim area than POAG (77 [20] vs. 71 [14] µm, 0.32 [0.28] vs. 0.40 [0.29] mm 3 , 0.6 [0.2] vs. 0.7 [0.1], 1.07 [0.40] vs. 0.89 [0.30] mm 2 , P <0.001 for all), while patients with POAG had more pronounced inferior RNFL thinning (82 [24] vs. 95 [35] µm, P <0.001). In a multivariable analysis, hyperopia [odds ratio (OR): 1.24, confidence interval (CI): 1.13-1.37], smaller cup-to-disc ratio (OR: 0.69, CI: 0.61-0.78), thicker inferior RNFL (OR: 1.15, CI: 1.06-1.26) and worse mean deviation (OR: 0.95, CI: 0.92-0.98) were associated with PACG. Functionally, POAG was associated with superior paracentral loss and PACG with inferior field loss. After adjusting for average RNFL thickness, PACG was associated with more diffuse loss than POAG (total deviation differences 1.26-3.2 dB). CONCLUSIONS: Patients with PACG had less structural damage than patients with POAG despite similar degrees of functional loss. Regional differences in patterns of functional and structural loss between POAG and PACG may improve disease monitoring for these glaucoma subtypes.


Asunto(s)
Glaucoma de Ángulo Cerrado , Glaucoma de Ángulo Abierto , Humanos , Estudios Transversales , Presión Intraocular , Pruebas del Campo Visual/métodos , Tomografía de Coherencia Óptica/métodos
6.
Transl Vis Sci Technol ; 12(11): 12, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37934137

RESUMEN

Purpose: Correcting retinal nerve fiber layer thickness (RNFLT) artifacts in glaucoma with deep learning and evaluate its clinical usefulness. Methods: We included 24,257 patients with optical coherence tomography and reliable visual field (VF) measurements within 30 days and 3,233 patients with reliable VF series of at least five measurements over ≥4 years. The artifacts are defined as RNFLT less than the known floor value of 50 µm. We selected 27,319 high-quality RNFLT maps with an artifact ratio (AR) of <2% as the ground truth. We created pseudo-artifacts from 21,722 low-quality RNFLT maps with AR of >5% and superimposed them on high-quality RNFLT maps to predict the artifact-free ground truth. We evaluated the impact of artifact correction on the structure-function relationship and progression forecasting. Results: The mean absolute error and Pearson correlation of the artifact correction were 9.89 µm and 0.90 (P < 0.001), respectively. Artifact correction improved R2 for VF prediction in RNFLT maps with AR of >10% and AR of >20% up to 0.03 and 0.04 (P < 0.001), respectively. Artifact correction improved (P < 0.05) the AUC for progression prediction in RNFLT maps with AR of ≤10%, >10%, and >20%: (1) total deviation pointwise progression: 0.68 to 0.69, 0.62 to 0.63, and 0.62 to 0.64; and (2) mean deviation fast progression: 0.67 to 0.68, 0.54 to 0.60, and 0.45 to 0.56. Conclusions: Artifact correction for RNFLTs improves VF and progression prediction in glaucoma. Translational Relevance: Our model improves clinical usability of RNFLT maps with artifacts.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Humanos , Artefactos , Retina , Fibras Nerviosas
7.
Clin Ophthalmol ; 17: 2803-2814, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37771393

RESUMEN

Purpose: To assess the rates of postoperative steroid response following dropless cataract surgery using a subconjunctival depot of triamcinolone versus conventional cataract surgery using topical prednisolone. Patients and Methods: We reviewed consecutive cataract surgery cases performed by a single surgeon to determine the likelihood of steroid response, defined as intraocular pressure (IOP) 50% above baseline or IOP > 24 mmHg postoperatively, excluding the first 72 hours. Logistic regression models were performed including baseline characteristics as exposures in the model and steroid response as the outcome. Main outcome measures were the proportion of eyes developing steroid response, risk factors for developing steroid response, and duration of steroid response. Results: Of the 150 dropless and 218 conventional cases, 26 eyes developed steroid response (15 dropless and 11 conventional cases [10% vs 5%, P=0.096]). Risk factors for steroid response included dropless surgery (OR=2.43, 95% CI=1.03-6.02], P=0.046) and prior diagnosis of glaucoma (OR=7.18, 95% CI=2.66-19.22], P<0.001). Baseline IOP, age, sex, race, and axial length did not increase risk for steroid response. Of the eyes with steroid response, more dropless cases had an IOP elevation ≥30 days (9/15 eyes vs 1/11 eyes; P=0.008), including one patient with refractory IOP elevation in the dropless group who required urgent bilateral trabeculectomy for IOP control. Conclusion: Dropless cataract surgery increases the risk of prolonged steroid response postoperatively. Patients with glaucoma have an increased risk of steroid response and may not be good candidates for dropless cataract surgery with subconjunctival triamcinolone.

8.
IEEE J Biomed Health Inform ; 27(9): 4329-4340, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37347633

RESUMEN

Ophthalmic images, along with their derivatives like retinal nerve fiber layer (RNFL) thickness maps, play a crucial role in detecting and monitoring eye diseases such as glaucoma. For computer-aided diagnosis of eye diseases, the key technique is to automatically extract meaningful features from ophthalmic images that can reveal the biomarkers (e.g., RNFL thinning patterns) associated with functional vision loss. However, representation learning from ophthalmic images that links structural retinal damage with human vision loss is non-trivial mostly due to large anatomical variations between patients. This challenge is further amplified by the presence of image artifacts, commonly resulting from image acquisition and automated segmentation issues. In this paper, we present an artifact-tolerant unsupervised learning framework called EyeLearn for learning ophthalmic image representations in glaucoma cases. EyeLearn includes an artifact correction module to learn representations that optimally predict artifact-free images. In addition, EyeLearn adopts a clustering-guided contrastive learning strategy to explicitly capture the affinities within and between images. During training, images are dynamically organized into clusters to form contrastive samples, which encourage learning similar or dissimilar representations for images in the same or different clusters, respectively. To evaluate EyeLearn, we use the learned representations for visual field prediction and glaucoma detection with a real-world dataset of glaucoma patient ophthalmic images. Extensive experiments and comparisons with state-of-the-art methods confirm the effectiveness of EyeLearn in learning optimal feature representations from ophthalmic images.


Asunto(s)
Glaucoma , Disco Óptico , Humanos , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica/métodos , Retina
9.
Ophthalmol Sci ; 3(3): 100310, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37197701

RESUMEN

Objective: Previous laboratory reports implicate heat shock protein (HSP)-specific T-cell responses in glaucoma pathogenesis; here, we aimed to provide direct clinical evidence by correlating systemic HSP-specific T-cell levels with glaucoma severity in patients with primary open-angle glaucoma (POAG). Design: Cross-sectional case-control study. Subjects: Thirty-two adult patients with POAG and 38 controls underwent blood draw and optic nerve imaging. Methods: Peripheral blood monocytes (PBMC) were stimulated in culture with HSP27, α-crystallin, a member of the small HSP family, or HSP60. Both interferon-γ (IFN-γ)+ CD4+ T helper type 1 cells (Th1) and transforming growth factor-ß1 (TGF-ß1)+ CD4+ regulatory T cells (Treg) were quantified by flow cytometry and presented as a percentage of total PBMC counts. Relevant cytokines were measured using enzyme-linked immunosorbent assays. Retinal nerve fiber layer thickness (RNFLT) was measured with OCT. Pearson's correlation (r) was used to assess correlations. Main Outcome Measures: Correlations of HSP-specific T-cell counts, and serum levels of corresponding cytokine levels with RNFLT. Results: Patients with POAG (visual field mean deviation, -4.7 ± 4.0 dB) and controls were similar in age, gender, and body mass index. Moreover, 46.9% of POAG and 60.0% of control subjects had prior cataract surgery (P = 0.48). Although no significant difference in total nonstimulated CD4+ Th1 or Treg cells was detected, patients with POAG exhibited significantly higher frequencies of Th1 cells specific for HSP27, α-crystallin, or HSP60 than controls (7.3 ± 7.9% vs. 2.6 ± 2.0%, P = 0.004; 5.8 ± 2.7% vs. 1.8 ± 1.3%, P < 0.001; 13.2 ± 13.3 vs. 4.3 ± 5.2, P = 0.01; respectively), but similar Treg specific for the same HSPs compared with controls (P ≥ 0.10 for all). Concordantly, the serum levels of IFN-γ were higher in POAG than in controls (36.2 ± 12.1 pg/ml vs. 10.0 ± 4.3 pg/ml; P < 0.001), but TGF-ß1 levels did not differ. Average RNFLT of both eyes negatively correlated with HSP27- and α-crystallin-specific Th1 cell counts, and IFN-γ levels in all subjects after adjusting for age (partial correlation coefficient r = -0.31, P = 0.03; r = -0.52, p = 0.002; r = -0.72, P < 0.001, respectively). Conclusions: Higher levels of HSP-specific Th1 cells are associated with thinner RNFLT in patients with POAG and control subjects. The significant inverse relationship between systemic HSP-specific Th1 cell count and RNFLT supports the role of these T cells in glaucomatous neurodegeneration. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

10.
BMC Ophthalmol ; 23(1): 129, 2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-36997879

RESUMEN

PURPOSE: To compare the effectiveness and safety of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco/ECP), phacoemulsification combined with MicroPulse transscleral cyclophotocoagulation (phaco/MP-TSCPC), and phacoemulsification alone (phaco) in the treatment of coexisting cataract and glaucoma. METHODS: Retrospective cohort study of consecutive cases at Massachusetts Eye & Ear. The main outcome measures were the cumulative probabilities of failure between the phaco/ECP group, phaco/MP-TSCPC group, and the phaco alone group with failure defined as reaching NLP vision at any point postoperatively, undergoing additional glaucoma surgery, or the inability to maintain ≥ 20% IOP reduction from baseline with IOP between 5-18 mmHg while maintaining ≤ baseline medications. Additional outcome measures included changes in average IOP, number of glaucoma medications, and complication rates. RESULTS: Sixty-four eyes from 64 patients (25 phaco/ECP, 20 phaco/MPTSCPC, 19 phaco alone) were included in this study. The groups did not differ in age (mean 71.04 ± 6.7 years) or length of follow-up time. Baseline IOPs were significantly different between groups (15.78 ± 4.7 mmHg phaco/ECP, 18.37 ± 4.6 mmHg phaco/MP-TSCPC, 14.30 ± 4.2 mmHg phaco alone, p = 0.02). Primary open-angle glaucoma was the most common type of glaucoma in the phaco alone (42%) and phaco/ECP (48%) groups while mixed-mechanism glaucoma was the most common type in the phaco/MP-TSCPC group (40%). Surgical failure was less likely in eyes in the phaco/MP-TSCPC (3.40 times, p = 0.005) and phaco/ECP (1.40 times, p = 0.044) groups compared to phaco alone based on the Kaplan-Meier survival criteria. These differences maintained statistical significance when differences in preoperative IOP were taken into account using the Cox PH model (p = 0.011 and p = 0.004, respectively). Additionally, surgical failure was 1.98 times less likely following phaco/MP-TSCPC compared to phaco/ECP (p = 0.038). This difference only approached significance once differences in preoperative IOP were accounted for (p = 0.052). There was no significant difference in IOP reduction at 1 year between groups. Mean IOP reductions at 1 year were 3.07 ± 5.3 mmHg from a baseline of 15.78 ± 4.7 in the phaco/ECP group, 6.0 ± 4.3 mmHg from a baseline of 18.37 ± 4.6 in the phaco/MP-TSCPC group and 1.0 ± 1.6 from a baseline of 14.30 ± 4.2 mmHg in the phaco alone group. There were no differences in complication rates among the three groups. CONCLUSIONS: Both Phaco/MP-TSCPC and phaco/ECP appear to provide superior efficacy for IOP control when compared to phaco alone. All three procedures had similar safety profiles.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Hipotensión Ocular , Facoemulsificación , Humanos , Persona de Mediana Edad , Anciano , Facoemulsificación/métodos , Presión Intraocular , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/cirugía , Estudios Retrospectivos , Coagulación con Láser/métodos , Glaucoma/cirugía , Resultado del Tratamiento
11.
Curr Opin Ophthalmol ; 34(2): 95-102, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36730770

RESUMEN

PURPOSE OF REVIEW: Advances in surgical techniques and postoperative care have significantly improved rates of short-term complications following keratoplasty; however, glaucoma remains a highly prevalent long-term and potentially devastating complication for postkeratoplasty patients. In this review, we provide an overview of recent literature on glaucoma management in patients who have undergone penetrating keratoplasty or the Boston keratoprosthesis type I (KPro) implantation. RECENT FINDINGS: New research suggests an inflammatory cause underlying glaucoma following KPro. Accurate IOP measurement is difficult in patients postkeratoplasty; study of objective techniques such as PDCT or Tono-Pen in penetrating keratoplasty eyes and trans-palpebral Diaton tonometry in KPro eyes have shown promising results. Early glaucoma surgical intervention should be considered for patients undergoing penetrating keratoplasty and KPro. SUMMARY: Patients who have undergone penetrating keratoplasty or implantation of the Boston keratoprosthesis type I should be monitored frequently for elevated intraocular pressure and for other signs of glaucomatous optic nerve damage. Intraocular pressure elevation should be treated promptly either medically or surgically while minimizing risk to the corneal graft. Further research into inflammatory causes and other treatment modalities is promising for the long-term visual success in these patients.


Asunto(s)
Enfermedades de la Córnea , Glaucoma , Humanos , Córnea/cirugía , Queratoplastia Penetrante/efectos adversos , Queratoplastia Penetrante/métodos , Enfermedades de la Córnea/etiología , Prótesis e Implantes/efectos adversos , Glaucoma/cirugía , Glaucoma/etiología , Presión Intraocular , Estudios Retrospectivos
12.
Curr Opin Ophthalmol ; 34(2): 168-175, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36730773

RESUMEN

PURPOSE OF REVIEW: The purpose of this review is to examine contemporary techniques for detecting the progression of glaucoma. We provide a general overview of detection principles and review evidence-based diagnostic strategies and specific considerations for detecting glaucomatous progression in patients with mild, moderate and severe disease. RECENT FINDINGS: Diagnostic techniques and technologies for glaucoma have dramatically evolved in recent years, affording clinicians an expansive toolkit with which to detect glaucoma progression. Each stage of glaucoma, however, presents unique diagnostic challenges. In mild disease, either structural or functional changes can develop first in disease progression. In moderate disease, structural or functional changes can occur either in tandem or in isolation. In severe disease, standard techniques may fail to detect further disease progression, but such detection can still be measured using other modalities. SUMMARY: Detecting disease progression is central to the management of glaucoma. Glaucomatous progression has both structural and functional elements, both of which must be carefully monitored at all disease stages to determine when interventions are warranted.


Asunto(s)
Glaucoma , Humanos , Progresión de la Enfermedad , Glaucoma/diagnóstico
13.
Semin Ophthalmol ; : 1-11, 2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36662128

RESUMEN

Black patients are more affected by glaucoma and suffer from more advanced disease. Diagnostic challenges among black patients with glaucoma include lower rates of diagnostic testing and thinner average central corneal thickness, the latter of which affects intraocular pressure measurement. Treatment challenges include poor follow-up, medication adherence, and trust in providers. Black patients undergoing trabeculectomy have higher rates of failure compared to white patients. Race is not a definitive factor affecting success for tube shunts, laser trabeculoplasty, cyclophotocoagulation, and micro-invasive glaucoma surgeries, but the body of evidence is limited by low inclusion of black patients in these studies. Future steps should include increased attention toward improving trust between patients and providers, improving access to care, and increased representation of black patients in glaucoma research to better understand factors affecting racial disparities in glaucoma management and outcomes in this population disproportionately affected by the disease.

14.
Semin Ophthalmol ; 38(1): 65-75, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36453915

RESUMEN

Black patients are more affected by glaucoma and suffer from more advanced disease. Diagnostic challenges among black patients with glaucoma include lower rates of diagnostic testing and thinner average central corneal thickness, the latter of which affects intraocular pressure measurement. Treatment challenges include poor follow-up, medication adherence, and trust in providers. Black patients undergoing trabeculectomy have higher rates of failure compared to white patients. Race is not a definitive factor affecting success for tube shunts, laser trabeculoplasty, cyclophotocoagulation, and micro-invasive glaucoma surgeries, but the body of evidence is limited by low inclusion of black patients in these studies. Future steps should include increased attention toward improving trust between patients and providers, improving access to care, and increased representation of black patients in glaucoma research to better understand factors affecting racial disparities in glaucoma management and outcomes in this population disproportionately affected by the disease.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Terapia por Láser , Trabeculectomía , Humanos , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular , Glaucoma/terapia , Glaucoma/cirugía , Población Negra
15.
Ophthalmol Glaucoma ; 6(3): 255-265, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36252920

RESUMEN

PURPOSE: To assess a model combining OCT angiography (OCTA) and OCT parameters to predict the severity of paracentral visual field (VF) loss in primary open-angle glaucoma (POAG). DESIGN: Cross-sectional study. PARTICIPANTS: Forty-four patients with POAG and 42 control subjects underwent OCTA and OCT imaging with a swept-source OCT device. METHODS: The circumpapillary microvasculature was quantified for vessel density (cpVD) and flow (cpFlow) after delineation of Bruch's membrane opening and removal of large vessels. Retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening-minimum rim width (BMO-MRW) were measured from structural OCT. Paracentral total deviation (PaTD) was defined as the average of the total deviation values within the central 10 degrees on Humphrey VF testing (24-2) for upper and lower hemifields. The OCT and OCTA parameters were measured in the affected hemisphere corresponding to the hemifield with lower PaTD for POAG patients. Models were created to predict affected PaTD based on RNFLT alone; RNFLT and BMO-MRW; OCTA alone; or RNFLT, BMO-MRW and OCTA parameters. The models were compared using coefficient of determination (r2) and Bayesian information criterion (BIC) score. Bayesian information criterion decrease of ≥6 indicates strong evidence for model improvement. MAIN OUTCOME MEASURES: Performance of models containing OCT and OCTA parameters in predicting PaTD. RESULTS: Patients with POAG and controls were similar in age and sex (65.9 ± 9.5 years and 38.4% male overall, P ≥ 0.56 for both). Average RNFLT, minimum RNFLT, average BMO-MRW, minimum BMO-MRW, cpVD, and cpFlow were all significantly lower (all P < 0.001) in the affected hemisphere in patients with POAG than in controls. In patients with POAG, the average mean deviation was -4.33 ± 3.25 dB; the PaTD of the affected hemifield averaged -4.55 ± 5.26 dB and correlated significantly with both OCTA and structural OCT parameters (r ≥ 0.43, P ≤ 0.004 for all). The model containing RNFLT, BMO-MRW, and OCTA parameters was superior in predicting affected PaTD (r2 = 0.47, BIC = 290.7), with higher r2 and lower BIC compared with all 3 other models. CONCLUSIONS: A combined model of OCTA and structural OCT parameters can predict the severity of paracentral VF loss of the affected hemifield, supporting clinical utility of OCTA in patients with POAG with paracentral VF loss. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Asunto(s)
Glaucoma de Ángulo Abierto , Disco Óptico , Humanos , Masculino , Femenino , Glaucoma de Ángulo Abierto/diagnóstico , Disco Óptico/irrigación sanguínea , Campos Visuales , Tomografía de Coherencia Óptica/métodos , Estudios Transversales , Teorema de Bayes , Presión Intraocular , Células Ganglionares de la Retina , Escotoma , Angiografía
16.
Eye (Lond) ; 37(10): 2117-2125, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36329167

RESUMEN

OBJECTIVE: To assess the cumulative incidence and risk factors for glaucoma development and progression within 1-2 years following corneal transplant surgery. DESIGN: Retrospective cohort study. METHODS: Patients undergoing penetrating keratoplasty (PK), deep anterior lamellar keratoplasty (DALK), Descemet stripping endothelial keratoplasty (DSEK), Descemet membrane endothelial keratoplasty (DMEK), Boston keratoprosthesis type I (KPro) implantation, or endothelial keratoplasty (DSEK or DMEK) under previous PK (EK under previous PK) at one academic institution with at least 1 year of follow-up were included. Primary outcome measures were cumulative incidence of glaucoma development and progression after corneal transplant, in patients without and with preoperative glaucoma, respectively. Risk factors for glaucoma development and progression were also assessed. RESULTS: Four hundred and thirty-one eyes of 431 patients undergoing PK (113), DALK (17), DSEK (71), DMEK (168), KPro (35) and EK under previous PK (27) with a mean follow-up of 22.9 months were analyzed. The 1-year cumulative incidence for glaucoma development and progression was 28.0% and 17.8% in patients without and with preoperative glaucoma, respectively. In a Cox proportional hazards analysis, DSEK surgery, KPro implantation, average intraocular pressure (IOP) through follow-up and postoperative IOP spikes of ≥30 mmHg were each independently associated with glaucoma development or progression (p < 0.04 for all). CONCLUSIONS: A significant proportion of patients developed glaucoma or exhibited glaucoma progression within 1 year after corneal transplantation. Patient selection for DSEK may partly explain the higher risk for glaucoma in these patients. Postoperative IOP spikes should be minimized and may indicate the need for co-management with a glaucoma specialist.


Asunto(s)
Enfermedades de la Córnea , Queratoplastia Endotelial de la Lámina Limitante Posterior , Glaucoma , Humanos , Incidencia , Estudios Retrospectivos , Córnea , Enfermedades de la Córnea/epidemiología , Enfermedades de la Córnea/cirugía , Enfermedades de la Córnea/complicaciones , Queratoplastia Endotelial de la Lámina Limitante Posterior/efectos adversos , Prótesis e Implantes/efectos adversos , Glaucoma/epidemiología , Glaucoma/etiología , Glaucoma/cirugía , Queratoplastia Penetrante/efectos adversos , Factores de Riesgo , Estudios de Seguimiento
17.
Ophthalmol Sci ; 2(3): 100161, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36245761

RESUMEN

Purpose: To assess 3-dimensional surface shape patterns of the optic nerve head (ONH) and peripapillary retinal nerve fiber layer (RNFL) in glaucoma with unsupervised artificial intelligence (AI). Design: Retrospective study. Participants: Patients with OCT scans obtained between 2016 and 2020 from Massachusetts Eye and Ear. Methods: The first reliable Cirrus (Carl Zeiss Meditec, Inc) ONH OCT scans from each eye were selected. The ONH and RNFL surface shape was represented by the vertical positions of the inner limiting membrane (ILM) relative to the lowest ILM vertical position in each eye. Nonnegative matrix factorization was applied to determine the ONH and RNFL surface shape patterns, which then were correlated with OCT and visual field (VF) loss parameters and subsequent VF loss rate. We tested whether using ONH and RNFL surface shape patterns improved the prediction accuracy for associated VF loss and subsequent VF loss rates measured by adjusted r 2 and Bayesian information criterion (BIC) difference compared with using established OCT parameters alone. Main Outcome Measures: Optic nerve head and RNFL surface shape patterns and prediction of the associated VF loss and subsequent VF loss rates. Results: We determined 14 ONH and RNFL surface shape patterns using 9854 OCT scans from 5912 participants. Worse mean deviation (MD) was most correlated (r = 0.29 and r = 0.24, Pearson correlation; each P < 0.001) with lower coefficients of patterns 10 and 12 representing inferior and superior para-ONH nerve thinning, respectively. Worse MD was associated most with higher coefficients of patterns 5, 4, and 9 (r = -0.16, r = -0.13, and r = -0.13, respectively), representing higher peripheral ONH and RNFL surfaces. In addition to established ONH summary parameters and 12-clock-hour RNFL thickness, using ONH and RNFL surface patterns improved (BIC decrease: 182, 144, and 101, respectively; BIC decrease ≥ 6; strong model improvement) the prediction of accompanied MD (r 2 from 0.32 to 0.37), superior (r 2 from 0.27 to 0.31), and inferior (r 2 from 0.17 to 0.21) paracentral loss and improved (BIC decrease: 8 and 8, respectively) the prediction of subsequent VF MD loss rates (r 2 from 0 to 0.13) and inferior paracentral loss rates (r 2 from 0 to 0.16). Conclusions: The ONH and RNFL surface shape patterns quantified by unsupervised AI techniques improved the structure-function relationship and subsequent VF loss rate prediction.

18.
Cornea ; 41(12): 1584-1599, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36197335

RESUMEN

ABSTRACT: Endothelial keratoplasty (EK), including Descemet stripping endothelial keratoplasty and Descemet membrane endothelial keratoplasty, is now the most performed corneal transplant procedure in the United States. Intraocular pressure (IOP) elevation and glaucoma are common complications and can cause irreversible vision loss and corneal graft failure. This review will cover the incidence, risk factors, and management of glaucoma and IOP elevation after EK. Higher preoperative IOP, preoperative glaucoma, and certain indications for EK, such as bullous keratopathy, are associated with increased risk of glaucoma and glaucoma progression in patients undergoing EK. In addition, we summarize the studies assessing graft outcomes in EK patients with glaucoma or glaucoma surgery. Finally, we provide future directions to improve clinical care in EK patients with glaucoma.


Asunto(s)
Enfermedades de la Córnea , Queratoplastia Endotelial de la Lámina Limitante Posterior , Glaucoma , Humanos , Queratoplastia Endotelial de la Lámina Limitante Posterior/efectos adversos , Agudeza Visual , Estudios Retrospectivos , Glaucoma/cirugía , Glaucoma/etiología , Tonometría Ocular , Presión Intraocular , Enfermedades de la Córnea/cirugía , Enfermedades de la Córnea/complicaciones , Endotelio Corneal
19.
Am J Ophthalmol ; 243: 42-54, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35850253

RESUMEN

PURPOSE: To assess clinical outcomes of patients with severe, cicatricial ocular surface disease (OSD) implanted with the currently marketed design of the Boston keratoprosthesis type II (BK2). DESIGN: Retrospective cohort study. METHODS: Records of consecutive patients undergoing BK2 implantation from June 2009 to March 2021 were assessed for postoperative visual acuity, postoperative complications, device replacement, and additional surgeries. RESULTS: Fifty-six eyes of 53 patients with a mean follow-up of 45.8 months (range, 0.2-134.7 months) were included. Stevens-Johnson syndrome/toxic epidermal necrolysis was the most common indication (49.1%), followed by mucous membrane pemphigoid (39.6%) and other OSD (11.3%). Visual acuity improved from logMAR 2.2 ± 0.5 preoperatively to 1.5 ± 1.2 at final follow-up. Of 56 eyes, 50 saw ≥20/200 at some point postoperatively. Of the eyes with a follow-up of more than 5 years, 50.0% retained a visual acuity of ≥20/200 at their final follow-up. The most common complications over the entire postoperative course (mean ∼4 years) were de novo or worsening glaucoma (41.1%), choroidal effusions (30.3%), retinal detachment (25.0%), and end-stage glaucoma (25.0%). In a univariate analysis, patients who experienced irreversible loss of ≥20/200 visual acuity were more likely to have been previously implanted with an older design of BK2, less likely to be on preoperative systemic immunosuppressive therapy, and less likely to have undergone concurrent glaucoma tube implantation, compared to patients who retained ≥20/200 acuity (P < .04 for all). CONCLUSIONS: Advances in device design and postoperative care have made implantation of BK2 a viable option for corneal blindness in the setting of severe cicatricial OSD.


Asunto(s)
Enfermedades de la Córnea , Glaucoma , Humanos , Córnea/cirugía , Prótesis e Implantes , Enfermedades de la Córnea/cirugía , Estudios Retrospectivos , Implantación de Prótesis , Glaucoma/cirugía
20.
Ophthalmol Glaucoma ; 5(2): 128-136, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34416426

RESUMEN

PURPOSE: To assess the prevalence of autoimmune disease (AiD) in patients with primary open-angle glaucoma (POAG) undergoing ophthalmic surgery. DESIGN: Retrospective, cross-sectional study. PARTICIPANTS: Patients with POAG undergoing any ophthalmic surgery and control subjects undergoing cataract surgery at the Massachusetts Eye and Ear from March 2019 to April 2020. METHODS: All available medical records with patient demographics, ocular, and medical conditions were reviewed. Differences in AiD prevalence were assessed and adjusted for covariates using multiple logistic regression. Additionally, a subgroup analysis comparing the POAG patients with and without AiD was performed. MAIN OUTCOME MEASURES: To assess the prevalence of AiD based on the American Autoimmune Related Diseases Association list. RESULTS: A total of 172 patients with POAG and 179 controls were included. The overall prevalence of AiD was 17.4% in the POAG group and 10.1% in the controls (P = 0.044); 6.4% of POAG patients and 3.4% of controls had more than 1 AiD (P = 0.18). The most prevalent AiDs in POAG group were rheumatoid arthritis (4.6%) and psoriasis (4.1%), which were also the most common in controls (2.8% each). In a fully adjusted multiple logistic regression analysis accounting for steroid use, having an AiD was associated with 2.62-fold increased odds of POAG relative to controls (95% confidence interval, 1.27-5.36, P = 0.009); other risk factors for POAG derived from the analysis included age (odds ratio [OR], 1.04, P = 0.006), diabetes mellitus (OR, 2.31, P = 0.008), and non-White ethnicity (OR, 4.75, P < 0.001). In a case-only analysis involving the eye with worse glaucoma, there was no statistical difference in visual field mean deviation or retinal nerve fiber layer (RNFL) thickness in POAG patients with AiD (n = 30) and without AiD (n = 142, P > 0.13, for both). CONCLUSIONS: A higher prevalence of AiD was found in POAG patients compared with control patients undergoing ophthalmic surgery. The presence of AiD was associated with increased risk for POAG after adjusting for covariates. Additional factors may have prevented a difference in RNFL thickness in POAG patients with and without AiD. Autoimmunity should be explored further in the pathogenesis of POAG.


Asunto(s)
Enfermedades Autoinmunes , Glaucoma de Ángulo Abierto , Enfermedades Autoinmunes/complicaciones , Enfermedades Autoinmunes/epidemiología , Estudios Transversales , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/epidemiología , Glaucoma de Ángulo Abierto/cirugía , Humanos , Prevalencia , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...