Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 207
Filtrar
1.
Clin Nutr ESPEN ; 63: 540-550, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39047869

RESUMEN

BACKGROUND & AIMS: Bioelectrical impedance analysis (BIA) for body composition estimation is increasingly used in clinical and field settings to guide nutrition and training programs. Due to variations among BIA devices and the proprietary prediction equations used, studies have recommended the use of raw measures of resistance (R) and reactance (Xc) within population-specific equations to predict body composition. OBJECTIVE: We compared raw measures from three BIA devices to assess inter-device variation and the impact of differences on body composition estimations. METHODS: Raw R, Xc, impedance (Z) parameters were measured on a calibrated phantom and athletes using tetrapolar supine (BIASUP4), octapolar supine (BIASUP8), and octapolar standing (BIASTA8) devices. Measures of R and Xc were compared across devices and graphed using BIA vector analysis (BIVA) and raw parameters were entered into recommended athlete-specific equations for predicting fat-free mass (FFM) and appendicular lean soft tissue (ALST). Whole-body FFM and regional ALST were compared across devices and to a criterion five-compartment (5C) model and dual energy X-ray absorptiometry for ALST. RESULTS: Data from 73 (23.2 ± 4.8 y) athletes were included in the analyses. Technical differences were observed between Z (range 12.2-50.1Ω) measures on the calibrated phantom. Differences in whole-body impedance were apparent due to posture (technological) and electrode placement (biological) factors. This resulted in raw measures for all three devices showing greater dehydration on BIVA compared to published norms for athletes using a separate BIA device. Compared to the 5C FFM, significant differences (p < 0.05) were observed on all three equations for BIASUP8 and BIASTA8, with constant error (CE) from -2.7 to -4.6 kg; no difference was observed for BIASUP4 or when device-specific algorithms were used. Published equations resulted in differences as large as 8.8 kg FFM among BIA devices. For ALST, even after a correction in the error of the published empirical equation, all three devices showed significant (p < 0.01) CE from -1.6 to -2.9 kg. CONCLUSIONS: Raw bioimpedance measurements differ among devices due to technical, technological, and biological factors, limiting interchangeability of data across BIA systems. Professionals should be aware of these factors when purchasing systems, comparing data to published reference ranges, or when applying published empirical body composition prediction equations.

2.
PLoS One ; 19(7): e0306606, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39024224

RESUMEN

BACKGROUND: We previously developed a prediction score for MRI-quantified abdominal visceral adipose tissue (VAT) based on concurrent measurements of height, body mass index (BMI), and nine blood biomarkers, for optimal performance in five racial/ethnic groups. Here we evaluated the VAT score for prediction of future VAT and examined if enhancement with additional biomarkers, lifestyle behavior information, and medical history improves the prediction. METHODS: We examined 500 participants from the Multiethnic Cohort (MEC) with detailed data (age 50-66) collected 10 years prior to their MRI assessment of VAT. We generated three forecasted VAT prediction models: first by applying the original VAT equation to the past data on the predictors ("original"), second by refitting the past data on anthropometry and biomarkers ("refit"), and third by building a new prediction model based on the past data enhanced with lifestyle and medical history ("enhanced"). We compared the forecasted prediction scores to future VAT using the coefficient of determination (R2). In independent nested case-control data in MEC, we applied the concurrent and forecasted VAT models to assess association of the scores with subsequent incident breast cancer (950 pairs) and colorectal cancer (831 pairs). RESULTS: Compared to the VAT prediction by the concurrent VAT score (R2 = 0.70 in men, 0.68 in women), the forecasted original VAT score (R2 = 0.54, 0.48) performed better than past anthropometry alone (R2 = 0.47, 0.40) or two published scores (VAI, METS-VF). The forecasted refit (R2 = 0.61, 0.51) and enhanced (R2 = 0.62, 0.55) VAT scores each showed slight improvements. Similar to the concurrent VAT score, the forecasted VAT scores were associated with breast cancer, but not colorectal cancer. Both the refit score (adjusted OR for tertile 3 vs. 1 = 1.27; 95% CI: 1.00-1.62) and enhanced score (1.27; 0.99-1.62) were associated with breast cancer independently of BMI. CONCLUSIONS: Predicted VAT from midlife data can be used as a surrogate to assess the effect of VAT on incident diseases associated with obesity, as illustrated for postmenopausal breast cancer.


Asunto(s)
Adiposidad , Grasa Intraabdominal , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Índice de Masa Corporal , Estudios de Casos y Controles , Estudios de Cohortes , Etnicidad , Grasa Intraabdominal/diagnóstico por imagen , Imagen por Resonancia Magnética , Neoplasias/diagnóstico por imagen , Grupos Raciales
3.
NPJ Microgravity ; 10(1): 72, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914554

RESUMEN

Individuals in isolated and extreme environments can experience debilitating side-effects including significant decreases in fat-free mass (FFM) from disuse and inadequate nutrition. The objective of this study was to determine the strengths and weaknesses of three-dimensional optical (3DO) imaging for monitoring body composition in either simulated or actual remote environments. Thirty healthy adults (ASTRO, male = 15) and twenty-two Antarctic Expeditioners (ABCS, male = 18) were assessed for body composition. ASTRO participants completed duplicate 3DO scans while standing and inverted by gravity boots plus a single dual-energy X-ray absorptiometry (DXA) scan. The inverted scans were an analog for fluid redistribution from gravity changes. An existing body composition model was used to estimate fat mass (FM) and FFM from 3DO meshes. 3DO body composition estimates were compared to DXA with linear regression and reported with the coefficient of determination (R2) and root mean square error (RMSE). ABCS participants received only duplicate 3DO scans on a monthly basis. Standing ASTRO meshes achieved an R2 of 0.76 and 0.97 with an RMSE of 2.62 and 2.04 kg for FM and FFM, while inverted meshes achieved an R2 of 0.52 and 0.93 with an RMSE of 2.84 and 3.23 kg for FM and FFM, respectively, compared to DXA. For the ABCS arm, mean weight, FM, and FFM changes were -0.47, 0.06, and -0.54 kg, respectively. Simulated fluid redistribution decreased the accuracy of estimated body composition values from 3DO scans. However, FFM stayed robust. 3DO imaging showed good absolute accuracy for body composition assessment in isolated and remote environments.

4.
J Vis Exp ; (208)2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38912781

RESUMEN

The body size and composition assessment is commonly included in the routine management of healthy athletes as well as of different types of patients to personalize the training or rehabilitation strategy. The digital anthropometric analyses described in the following protocol can be performed with recently introduced systems. These new tools and approaches have the potential to be widely used in clinical settings because they are very simple to operate and enable the rapid collection of accurate and reproducible data. One system consists of a rotating platform with a weight measurement plate, three infrared cameras, and a tablet built into a tower, while the other system consists of a tablet mounted on a holder. After image capture, the software of both systems generates a de-identified three-dimensional humanoid avatar with associated anthropometric and body composition variables. The measurement procedures are simple: a subject can be tested in a few minutes and a comprehensive report (including the three-dimensional scan and body size, shape, and composition measurements) is automatically generated.


Asunto(s)
Antropometría , Composición Corporal , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Antropometría/métodos , Imagen Óptica/métodos
5.
Nutrition ; 125: 112494, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38843564

RESUMEN

BACKGROUND AND AIMS: Measurement of body composition using computed tomography (CT) scans may be a viable clinical tool for low muscle mass assessment in oncology. However, longitudinal assessments are often infeasible with CT. Clinically accessible body composition technologies can be used to track changes in fat-free mass (FFM) or muscle, though their accuracy may be impacted by cancer-related physiological changes. The purpose of this study was to examine the agreement among accessible body composition method with criterion methods for measures of whole-body FFM measurements and, when possible, muscle mass for the classification of low muscle in patients with cancer. METHODS: Patients with colorectal cancer were recruited to complete measures of whole-body DXA, air displacement plethysmography (ADP), and bioelectrical impedance analysis (BIA). These measures were used alone, or in combination to construct the criterion multicompartment (4C) mode for estimating FFM. Patients also underwent abdominal CT scans as part of routine clinical assessment. Agreement of each method with 4C model was analyzed using mean constant error (CE = criterion - alternative), linear regression including root mean square error (RMSE), Bland-Altman limits of agreement (LoA) and mean percentage difference (MPD). Additionally, appendicular lean soft tissue index (ALSTI) measured by DXA and predicted by CT were compared for the absolute agreement, while the ALSTI values and skeletal muscle index by CT were assessed for agreement on the classification of low muscle mass. RESULTS: Forty-five patients received all measures for the 4C model and 25 had measures within proximity of clinical CT measures. Compared to 4C, DXA outperformed ADP and BIA by showing the strongest overall agreement (CE = 1.96 kg, RMSE = 2.45 kg, MPD = 98.15 ± 2.38%), supporting its use for body composition assessment in patients with cancer. However, CT cutoffs for skeletal muscle index or CT-estimated ALSTI were lower than DXA ALSTI (average 1.0 ± 1.2 kg/m2) with 24.0% to 32.0% of patients having a different low muscle classification by CT when compared to DXA. CONCLUSIONS: Despite discrepancies between clinical body composition assessment and the criterion multicompartment model, DXA demonstrates the strongest agreement with 4C. Disagreement between DXA and CT for low muscle mass classification prompts further evaluation of the measures and cutoffs used with each technique. Multicompartment models may enhance our understanding of body composition variations at the individual patient level and improve the applicability of clinically accessible technologies for classification and monitoring change over time.


Asunto(s)
Absorciometría de Fotón , Composición Corporal , Neoplasias Colorrectales , Impedancia Eléctrica , Músculo Esquelético , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Persona de Mediana Edad , Absorciometría de Fotón/métodos , Anciano , Tomografía Computarizada por Rayos X/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiopatología , Pletismografía/métodos , Adulto
6.
Obes Rev ; 25(9): e13767, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38761009

RESUMEN

Beyond obesity, excess levels of visceral adipose tissue (VAT) significantly contribute to the risk of developing metabolic syndrome (MetS), although thresholds for increased risk vary based on population, regions of interest, and units of measure employed. We sought to determine whether a common threshold exists that is indicative of heightened MetS risk across all populations, accounting for sex, age, BMI, and race/ethnicity. A systematic literature review was conducted in September 2023, presenting threshold values for elevated MetS risk. Standardization equations harmonized the results from DXA, CT, and MRI systems to facilitate a comparison of threshold variations across studies. A total of 52 papers were identified. No single threshold could accurately indicate elevated risk for both males and females across varying BMI, race/ethnicity, and age groups. Thresholds fluctuated from 70 to 165.9 cm2, with reported values consistently lower in females. Generally, premenopausal females and younger adults manifested elevated risks at lower VAT compared to their older counterparts. Notably, Asian populations exhibited elevated risks at lower VAT areas (70-136 cm2) compared to Caucasian populations (85.6-165.9 cm2). All considered studies reported associations of VAT without accommodating covariates. No single VAT area threshold for elevated MetS risk was discernible post-harmonization by technology, units of measure, and region of interest. This review summarizes available evidence for MetS risk assessment in clinical practice. Further exploration of demographic-specific interactions between VAT area and other risk factors is imperative to comprehensively delineate overarching MetS risk.


Asunto(s)
Grasa Intraabdominal , Síndrome Metabólico , Humanos , Femenino , Factores de Riesgo , Índice de Masa Corporal , Masculino
7.
Int J Cancer ; 155(4): 627-636, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38567797

RESUMEN

Whether trace metals modify breast density, the strongest predictor for breast cancer, during critical developmental stages such as puberty remains understudied. Our study prospectively evaluated the association between trace metals at Tanner breast stage B1 (n = 291) and at stages both B1 and B4 (n = 253) and breast density at 2 years post-menarche among Chilean girls from the Growth and Obesity Cohort Study. Dual-energy x-ray absorptiometry assessed the volume of dense breast tissue (absolute fibroglandular volume [FGV]) and percent breast density (%FGV). Urine trace metals included arsenic, barium, cadmium, cobalt, cesium, copper, magnesium, manganese, molybdenum, nickel, lead, antimony, selenium, tin, thallium, vanadium, and zinc. At B1, a doubling of thallium concentration resulted in 13.69 cm3 increase in absolute FGV (ß: 13.69, 95% confidence interval [CI]: 2.81, 24.52), while a doubling of lead concentration resulted in a 7.76 cm3 decrease in absolute FGV (ß: -7.76, 95%CI: -14.71, -0.73). At B4, a doubling of barium concentration was associated with a 10.06 cm3 increase (ß: 10.06, 95% CI: 1.44, 18.60), copper concentration with a 12.29 cm3 increase (ß: 12.29, 95% CI: 2.78, 21.56), lead concentration with a 9.86 cm3 increase (ß: 9.86, 95% CI: 0.73, 18.98), antimony concentration with a 12.97 cm3 increase (ß: 12.97, 95% CI: 1.98, 23.79) and vanadium concentration with a 13.14 cm3 increase in absolute FGV (ß: 13.14, 95% CI: 2.73, 23.58). Trace metals may affect pubertal breast density at varying developmental stages with implications for increased susceptibility for breast cancer.


Asunto(s)
Absorciometría de Fotón , Densidad de la Mama , Oligoelementos , Humanos , Femenino , Chile/epidemiología , Adolescente , Densidad de la Mama/efectos de los fármacos , Oligoelementos/análisis , Oligoelementos/orina , Estudios Prospectivos , Niño , Mama/efectos de los fármacos , Mama/crecimiento & desarrollo , Neoplasias de la Mama/epidemiología
8.
Patterns (N Y) ; 5(3): 100924, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38487799

RESUMEN

Combining classification systems potentially improves predictive accuracy, but outcomes have proven impossible to predict. Similar to improving binary classification with fusion, fusing ranking systems most commonly increases Pearson or Spearman correlations with a target when the input classifiers are "sufficiently good" (generalized as "accuracy") and "sufficiently different" (generalized as "diversity"), but the individual and joint quantitative influence of these factors on the final outcome remains unknown. We resolve these issues. Building on our previous empirical work establishing the DIRAC (DIversity of Ranks and ACcuracy) framework, which accurately predicts the outcome of fusing binary classifiers, we demonstrate that the DIRAC framework similarly explains the outcome of fusing ranking systems. Specifically, precise geometric representation of diversity and accuracy as angle-based distances within rank-based combinatorial structures (permutahedra) fully captures their synergistic roles in rank approximation, uncouples them from the specific metrics of a given problem, and represents them as generally as possible.

9.
J Clin Densitom ; 27(2): 101480, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38401238

RESUMEN

BACKGROUND: Artificial intelligence (AI) large language models (LLMs) such as ChatGPT have demonstrated the ability to pass standardized exams. These models are not trained for a specific task, but instead trained to predict sequences of text from large corpora of documents sourced from the internet. It has been shown that even models trained on this general task can pass exams in a variety of domain-specific fields, including the United States Medical Licensing Examination. We asked if large language models would perform as well on a much narrower subdomain tests designed for medical specialists. Furthermore, we wanted to better understand how progressive generations of GPT (generative pre-trained transformer) models may be evolving in the completeness and sophistication of their responses even while generational training remains general. In this study, we evaluated the performance of two versions of GPT (GPT 3 and 4) on their ability to pass the certification exam given to physicians to work as osteoporosis specialists and become a certified clinical densitometrists. The CCD exam has a possible score range of 150 to 400. To pass, you need a score of 300. METHODS: A 100-question multiple-choice practice exam was obtained from a 3rd party exam preparation website that mimics the accredited certification tests given by the ISCD (International Society for Clinical Densitometry). The exam was administered to two versions of GPT, the free version (GPT Playground) and ChatGPT+, which are based on GPT-3 and GPT-4, respectively (OpenAI, San Francisco, CA). The systems were prompted with the exam questions verbatim. If the response was purely textual and did not specify which of the multiple-choice answers to select, the authors matched the text to the closest answer. Each exam was graded and an estimated ISCD score was provided from the exam website. In addition, each response was evaluated by a rheumatologist CCD and ranked for accuracy using a 5-level scale. The two GPT versions were compared in terms of response accuracy and length. RESULTS: The average response length was 11.6 ±19 words for GPT-3 and 50.0±43.6 words for GPT-4. GPT-3 answered 62 questions correctly resulting in a failing ISCD score of 289. However, GPT-4 answered 82 questions correctly with a passing score of 342. GPT-3 scored highest on the "Overview of Low Bone Mass and Osteoporosis" category (72 % correct) while GPT-4 scored well above 80 % accuracy on all categories except "Imaging Technology in Bone Health" (65 % correct). Regarding subjective accuracy, GPT-3 answered 23 questions with nonsensical or totally wrong responses while GPT-4 had no responses in that category. CONCLUSION: If this had been an actual certification exam, GPT-4 would now have a CCD suffix to its name even after being trained using general internet knowledge. Clearly, more goes into physician training than can be captured in this exam. However, GPT algorithms may prove to be valuable physician aids in the diagnoses and monitoring of osteoporosis and other diseases.


Asunto(s)
Inteligencia Artificial , Certificación , Humanos , Osteoporosis/diagnóstico , Competencia Clínica , Evaluación Educacional/métodos , Estados Unidos
10.
Cancer Epidemiol Biomarkers Prev ; 33(4): 567-575, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38270539

RESUMEN

BACKGROUND: Folate is the primary methyl donor and B vitamins are cofactors for one-carbon metabolism that maintain DNA integrity and epigenetic signatures implicated in carcinogenesis. Breast tissue is particularly susceptible to stimuli in early life. Only limited data are available on associations of one-carbon metabolism-related vitamin intake during youth and young adulthood with breast density, a strong risk factor for breast cancer. METHODS: Over 18 years in the DISC and DISC06 Follow-up Study, diets of 182 young women were assessed by three 24-hour recalls on five occasions at ages 8 to 18 years and once at 25 to 29 years. Multivariable-adjusted linear mixed-effects regression was used to examine associations of intakes of one-carbon metabolism-related vitamins with MRI-measured percent dense breast volume (%DBV) and absolute dense breast volume (ADBV) at ages 25 to 29 years. RESULTS: Folate intake in youth was inversely associated with %DBV (Ptrend = 0.006) and ADBV (Ptrend = 0.02). These inverse associations were observed with intake during post-, though not premenarche. In contrast, premenarche vitamin B2 intake was positively associated with ADBV (Ptrend < 0.001). Young adult folate and vitamin B6 intakes were inversely associated with %DBV (all Ptrend ≤ 0.04), whereas vitamins B6 and B12 were inversely associated with ADBV (all Ptrend ≤ 0.04). CONCLUSIONS: Among these DISC participants intakes of one-carbon metabolism-related vitamins were associated with breast density. Larger prospective studies among diverse populations are needed to replicate these findings. IMPACT: Our results suggest the importance of one-carbon metabolism-related vitamin intakes early in life with development of breast density and thereby potentially breast cancer risk later in life.


Asunto(s)
Neoplasias de la Mama , Vitaminas , Adolescente , Adulto Joven , Femenino , Humanos , Adulto , Densidad de la Mama , Neoplasias de la Mama/etiología , Estudios de Seguimiento , Estudios Prospectivos , Mamografía , Ácido Fólico , Vitamina A , Vitamina K , Carbono
11.
Obes Sci Pract ; 10(1): e734, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38259353

RESUMEN

Background: There are established links between the accumulation of body fat as visceral adipose tissue (VAT) and the risk of developing obesity-associated metabolic disease. Previous studies have suggested that levels of intake of specific foods and nutrients are associated with VAT accumulation after accounting for total energy intake. Objective: This study assessed associations between a priori selected dietary factors on VAT quantified using abdominal magnetic resonance imaging. Methods: The cross-sectional Multiethnic Cohort Adiposity Phenotype Study included n = 395 White, n = 274 Black, n = 269 Native Hawaiian, n = 425 Japanese American and n = 358 Latino participants (mean age = 69 years ± 3 SD). Participants were enrolled stratified on sex, race, ethnicity and body mass index. General linear models were used to estimate the mean VAT area (cm2) for participants categorized into quartiles based on their dietary intake of selected foods/nutrients adjusting for age, sex, racial and ethnic groups, the total percentage fat from whole-body dual energy X-ray absorptiometry and total energy. Results: There were significant inverse associations with VAT for dietary intake of total vegetables, total fruits (including juice), cereals, whole grains, calcium, copper and dietary fiber (p-trend ≤0.04). Positive trends were observed for VAT for participants who reported higher intake of potatoes, total fat and saturated fatty acids (SFA) (p-trend ≤0.02). Foods/nutrients that met the multiple testing significance threshold were total fruits, whole grains, copper, dietary fiber and SFA intake. Conclusions: These results highlight foods and nutrients including SFA, total fruit, whole grains, fiber and copper as potential candidates for future research to inform dietary guidelines for the prevention of chronic disease among older adults.

12.
Nutr Metab Cardiovasc Dis ; 34(3): 799-806, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38218711

RESUMEN

BACKGROUND AND AIMS: Body fat distribution, i.e., visceral (VAT), subcutaneous adipose tissue (SAT) and intramuscular fat, is important for disease prevention, but sex and ethnic differences are not well understood. Our aim was to identify anthropometric, demographic, and lifestyle predictors for these outcomes. METHODS AND RESULTS: The cross-sectional ShapeUp!Kids study was conducted among five ethnic groups aged 5-18 years. All participants completed questionnaires, anthropometric measurements, and abdominal MRI scans. VAT and SAT areas at four lumbar levels and muscle density were assessed manually. General linear models were applied to estimate coefficients of determination (R2) and to compare the fit of VAT and SAT prediction models. After exclusions, the study population had 133 male and 170 female participants. Girls had higher BMI-z scores, waist circumference (WC), and SAT than boys but lower VAT/SAT and muscle density. SAT, VAT, and VAT/SAT but not muscle density differed significantly by ethnicity. R2 values were higher for SAT than VAT across groups and improved slightly after adding WC. For SAT, R2 increased from 0.85 to 0.88 (girls) and 0.62 to 0.71 (boys) when WC was added while VAT models improved from 0.62 to 0.65 (girls) and 0.57 to 0.62 (boys). VAT values were significantly lower among Blacks than Whites with little difference for the other groups. CONCLUSION: This analysis in a multiethnic population identified BMI-z scores and WC as the major predictors of MRI-derived SAT and VAT and highlights the important ethnic differences that need to be considered in diverse populations.


Asunto(s)
Músculos , Grasa Subcutánea , Humanos , Masculino , Femenino , Estudios Transversales , Grasa Subcutánea/diagnóstico por imagen , Antropometría/métodos , Circunferencia de la Cintura
13.
Commun Med (Lond) ; 4(1): 13, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38287144

RESUMEN

BACKGROUND: Body shape, an intuitive health indicator, is deterministically driven by body composition. We developed and validated a deep learning model that generates accurate dual-energy X-ray absorptiometry (DXA) scans from three-dimensional optical body scans (3DO), enabling compositional analysis of the whole body and specified subregions. Previous works on generative medical imaging models lack quantitative validation and only report quality metrics. METHODS: Our model was self-supervised pretrained on two large clinical DXA datasets and fine-tuned using the Shape Up! Adults study dataset. Model-predicted scans from a holdout test set were evaluated using clinical commercial DXA software for compositional accuracy. RESULTS: Predicted DXA scans achieve R2 of 0.73, 0.89, and 0.99 and RMSEs of 5.32, 6.56, and 4.15 kg for total fat mass (FM), fat-free mass (FFM), and total mass, respectively. Custom subregion analysis results in R2s of 0.70-0.89 for left and right thigh composition. We demonstrate the ability of models to produce quantitatively accurate visualizations of soft tissue and bone, confirming a strong relationship between body shape and composition. CONCLUSIONS: This work highlights the potential of generative models in medical imaging and reinforces the importance of quantitative validation for assessing their clinical utility.


Body composition, measured quantities of muscle, fat, and bone, is typically assessed through dual energy X-ray absorptiometry (DXA) scans, which requires specialized equipment, trained technicians and involves exposure to radiation. Exterior body shape is dependent on body composition and recent technological advances have made three-dimensional (3D) scanning for body shape accessible and virtually ubiquitous. We developed a model which uses 3D body surface scan inputs to generate DXA scans. When analyzed with commercial software that is used clinically, our model generated images yielded accurate quantities of fat, lean, and bone. Our work highlights the strong relationship between exterior body shape and interior composition. Moreover, it suggests that with enhanced accuracy, such medical imaging models could be more widely adopted in clinical care, making the analysis of body composition more accessible and easier to obtain.

14.
Eur J Clin Nutr ; 78(5): 452-454, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38142263

RESUMEN

Currently available anthropometric body composition prediction equations were often developed on small participant samples, included only several measured predictor variables, or were prepared using conventional statistical regression methods. Machine learning approaches are increasingly publicly available and have key advantages over statistical modeling methods when developing prediction algorithms on large datasets with multiple complex covariates. This study aimed to test the feasibility of predicting DXA-measured appendicular lean mass (ALM) with a neural network (NN) algorithm developed on a sample of 576 participants using 10 demographic (sex, age, 7 ethnic groupings) and 43 anthropometric dimensions generated with a 3D optical scanner. NN-predicted and measured ALM were highly correlated (n = 116; R2, 0.95, p < 0.001, non-significant bias) with small mean, absolute, and root-mean square errors (X ± SD, -0.17 ± 1.64 kg and 1.28 ± 1.04 kg; 1.64). These observations demonstrate the application of NN body composition prediction algorithms to rapidly emerging large and complex digital anthropometric datasets. Clinical Trial Registration: NCT03637855, NCT05217524, NCT03771417, and NCT03706612.


Asunto(s)
Algoritmos , Antropometría , Composición Corporal , Redes Neurales de la Computación , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Absorciometría de Fotón/métodos , Antropometría/métodos
15.
Eur J Clin Nutr ; 78(3): 236-242, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38097807

RESUMEN

INTRODUCTION: As several behaviors captured by the Lifestyle Risk Factor Index (LSRI) are protective against Type 2 diabetes (T2D) and may affect body fat distribution, we examined its relation with both outcomes. METHODS: In a subset of the Multiethnic Cohort, participants from five ethnic groups (60-77 years) were assigned LSRI scores (one point each for consuming <1 (women)/<2 (men) alcoholic drinks/day, ≥1.5 physical activity hours/week, not smoking, and adhering to ≥3/7 dietary recommendations). All participants completed an extensive Quantitative Food Frequency Questionnaire to allow estimation of adherence to intake recommendations for fruits, vegetables, refined and whole grains, fish, processed and non-processed meat. Glycemic/T2D status was classified according to self-reports and fasting glucose. We estimated prevalence odds ratios (POR) of LSRI with glycemic/T2D status and DXA- and MRI-based body fat distribution using logistic regression. RESULTS: Of 1713 participants, 43% had normoglycemia, 30% Pre-T2D, 9% Undiagnosed T2D, and 18% T2D. Overall, 39% scored 0-2, 49% 3, and 12% 4 LSRI points. T2D prevalence was 55% (POR 0.45; 95% confidence intervals 0.27, 0.76) lower for 4 vs. 0-2 LSRI points with weaker associations for abnormal glycemic status. Despite the low adherence to dietary recommendations (22%), this was the only component related to lower T2D prevalence. The inverse LSRI-T2D association was only observed among Latinos and Japanese Americans in ethnic-specific models. Visceral fat measures were higher in T2D patients and attenuated the LSRI-T2D association. CONCLUSION: These findings support the role of a healthy lifestyle, especially diet, in T2D prevention with differences across ethnicity.


Asunto(s)
Diabetes Mellitus Tipo 2 , Masculino , Animales , Humanos , Femenino , Diabetes Mellitus Tipo 2/epidemiología , Estudios Transversales , Dieta , Factores de Riesgo , Estilo de Vida Saludable
16.
Clin Nutr ; 43(1): 284-294, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38104490

RESUMEN

BACKGROUND: Athletes vary in hydration status due to ongoing training regimes, diet demands, and extreme exertion. With water being one of the largest body composition compartments, its variation can cause misinterpretation of body composition assessments meant to monitor strength and training progress. In this study, we asked what accessible body composition approach could best quantify body composition in athletes with a variety of hydration levels. METHODS: The Da Kine Study recruited collegiate and intramural athletes to undergo a variety of body composition assessments including air-displacement plethysmography (ADP), deuterium-oxide dilution (D2O), dual-energy X-ray absorptiometry (DXA), underwater-weighing (UWW), 3D-optical (3DO) imaging, and bioelectrical impedance (BIA). Each of these methods generated 2- or 3-compartment body composition estimates of fat mass (FM) and fat-free mass (FFM) and was compared to equivalent measures of the criterion 6-compartment model (6CM) that accounts for variance in hydration. Body composition by each method was used to predict abdominal and thigh strength, assessed by isokinetic/isometric dynamometry. RESULTS: In total, 70 (35 female) athletes with a mean age of 21.8 ± 4.2 years were recruited. Percent hydration (Body Water6CM/FFM6CM) had substantial variation in both males (63-73 %) and females (58-78 %). ADP and DXA FM and FF M had moderate to substantial agreement with the 6C model (Lin's Concordance Coefficient [CCC] = 0.90-0.95) whereas the other measures had lesser agreement (CCC <0.90) with one exception of 3DO FFM in females (CCC = 0.91). All measures of FFM produced excellent precision with %CV < 1.0 %. However, FM measures in general had worse precision (% CV < 2.0 %). Increasing quartiles (significant p < 0.001 trend) of 6CM FFM resulted in increasing strength measures in males and females. Moreover, the stronger the agreement between the alternative methods to the 6CM, the more robust their correlation with strength, irrespective of hydration status. CONCLUSION: The criterion 6CM showed the best association to strength regardless of the hydration status of the athletes for both males and females. Simpler methods showed high precision for both FM and FFM and those with the strongest agreement to the 6CM had the highest strength associations. SUMMARY BOX: This study compared various body composition analysis methods in 70 athletes with varying states of hydration to the criterion 6-compartment model and assessed their relationship to muscle strength. The results showed that accurate and precise estimates of body composition can be determined in athletes, and a more accurate body composition measurement produces better strength estimates. The best laboratory-based techniques were air displacement plethysmography and dual-energy x-ray absorptiometry, while the commercial methods had moderate-poor agreement. Prioritizing accurate body composition assessment ensures better strength estimates in athletes.


Asunto(s)
Composición Corporal , Agua Corporal , Masculino , Humanos , Femenino , Adolescente , Adulto Joven , Adulto , Composición Corporal/fisiología , Atletas , Absorciometría de Fotón/métodos , Impedancia Eléctrica , Fuerza Muscular , Reproducibilidad de los Resultados
17.
Clin Nutr ; 43(2): 346-356, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38142479

RESUMEN

BACKGROUND & AIMS: The multicompartment approach to body composition modeling provides a more precise quantification of body compartments in healthy and clinical populations. We sought to develop and validate a simplified and accessible multicompartment body composition model using 3-dimensional optical (3DO) imaging and bioelectrical impedance analysis (BIA). METHODS: Samples of adults and collegiate-aged student-athletes were recruited for model calibration. For the criterion multicompartment model (Wang-5C), participants received measures of scale weight, body volume (BV) via air displacement, total body water (TBW) via deuterium dilution, and bone mineral content (BMC) via dual energy x-ray absorptiometry. The candidate model (3DO-5C) used stepwise linear regression to derive surrogate measures of BV using 3DO, TBW using BIA, and BMC using demographics. Test-retest precision of the candidate model was assessed via root mean square error (RMSE). The 3DO-5C model was compared to criterion via mean difference, concordance correlation coefficient (CCC), and Bland-Altman analysis. This model was then validated using a separate dataset of 20 adults. RESULTS: 67 (31 female) participants were used to build the 3DO-5C model. Fat-free mass (FFM) estimates from Wang-5C (60.1 ± 13.4 kg) and 3DO-5C (60.3 ± 13.4 kg) showed no significant mean difference (-0.2 ± 2.0 kg; 95 % limits of agreement [LOA] -4.3 to +3.8) and the CCC was 0.99 with a similar effect in fat mass that reflected the difference in FFM measures. In the validation dataset, the 3DO-5C model showed no significant mean difference (0.0 ± 2.5 kg; 95 % LOA -3.6 to +3.7) for FFM with almost perfect equivalence (CCC = 0.99) compared to the criterion Wang-5C. Test-retest precision (RMSE = 0.73 kg FFM) supports the use of this model for more frequent testing in order to monitor body composition change over time. CONCLUSIONS: Body composition estimates provided by the 3DO-5C model are precise and accurate to criterion methods when correcting for field calibrations. The 3DO-5C approach offers a rapid, cost-effective, and accessible method of body composition assessment that can be used broadly to guide nutrition and exercise recommendations in athletic settings and clinical practice.


Asunto(s)
Composición Corporal , Densidad Ósea , Adulto , Humanos , Femenino , Anciano , Impedancia Eléctrica , Absorciometría de Fotón/métodos , Imagen Óptica , Reproducibilidad de los Resultados
18.
Sci Rep ; 13(1): 20734, 2023 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-38007571

RESUMEN

Digital anthropometry by three-dimensional optical imaging systems and smartphones has recently been shown to provide non-invasive, precise, and accurate anthropometric and body composition measurements. To our knowledge, no previous study performed smartphone-based digital anthropometric assessments in young athletes. The aim of this study was to investigate the reproducibly and validity of smartphone-based estimation of anthropometric and body composition parameters in youth soccer players. A convenience sample of 124 male players and 69 female players (median ages of 16.2 and 15.5 years, respectively) was recruited. Measurements of body weight and height, one whole-body Dual-Energy X-ray Absorptiometry (DXA) scan, and acquisition of optical images (performed in duplicate by the Mobile Fit app to obtain two avatars for each player) were performed. The reproducibility analysis showed percent standard error of measurement values < 10% for all anthropometric and body composition measurements, thus indicating high agreement between the measurements obtained for the two avatars. Mobile Fit app overestimated the body fat percentage with respect to DXA (average overestimation of + 3.7% in males and + 4.6% in females), while it underestimated the total lean mass (- 2.6 kg in males and - 2.5 kg in females) and the appendicular lean mass (- 10.5 kg in males and - 5.5 kg in females). Using data of the soccer players, we reparameterized the equations previously proposed to estimate the body fat percentage and the appendicular lean mass and we obtained new equations that can be used in youth athletes for body composition assessment through conventional anthropometrics-based prediction models.


Asunto(s)
Adiposidad , Fútbol , Humanos , Masculino , Adolescente , Femenino , Teléfono Inteligente , Reproducibilidad de los Resultados , Grosor de los Pliegues Cutáneos , Obesidad , Antropometría/métodos , Composición Corporal , Absorciometría de Fotón
19.
Obesity (Silver Spring) ; 31(12): 2936-2946, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37789584

RESUMEN

OBJECTIVE: Excess visceral adipose tissue (VAT) is a major risk factor for metabolic syndrome (MetS) and clinical guidelines have been proposed to define VAT levels associated with increased risk. The aim was to standardize VAT measures between two dual-energy x-ray absorptiometry (DXA) manufacturers who provide different VAT estimates to support standardization of measures across imaging modalities. METHODS: Scans from 114 individuals (ages 18-81 years) on GE HealthCare (GEHC) and Hologic DXA systems were compared via Deming regression to standardize VAT between the two systems, validated in a separate sample (n = 15), with κ statistics to assess agreement of VAT measurements for classifying patients into risk categories. RESULTS: The GEHC and Hologic VAT measures were highly correlated and validated in the separate data set (r2 = 0.97). VAT area measures substantially agreed for metabolic risk classification (weighted κ = 0.76) with no significant differences in the population mean values. CONCLUSIONS: VAT measures can be estimated from GEHC and Hologic scans that classify individuals in a substantially similar way into metabolic risk categories, and systematic bias between the measures can be removed using simple regression equations. These findings allow for DXA VAT measures to be used in complement to other imaging modalities, regardless of whether scans used GEHC or Hologic systems.


Asunto(s)
Tejido Adiposo , Grasa Intraabdominal , Humanos , Grasa Intraabdominal/diagnóstico por imagen , Rayos X , Absorciometría de Fotón/métodos , Estándares de Referencia , Factores de Riesgo
20.
Obesity (Silver Spring) ; 31(12): 2947-2959, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37795576

RESUMEN

OBJECTIVE: The National Health and Nutrition Examination Survey (NHANES) characterizes body composition representative of the US population using dual-energy x-ray absorptiometry (DXA) scans. These population-level trends of abdominal subcutaneous and visceral adipose tissue (SAT and VAT) are useful for identifying measures associated with increased disease risk. Recently, VAT and SAT data collected by Hologic DXA in NHANES were published online; however, there are known differences in the absolute calibration of DXA systems by make. The purpose of this study was to create reference tables suitable for calculating z scores and percentile values for GE HealthCare (GEHC) DXA systems. METHODS: DXA scans were acquired on participants aged 8 to 59 years using Hologic systems. DXA measures were converted to GEHC and described using the least median squares curve fitting method in pediatrics (aged <20 years) and adults (aged 20-59 years). RESULTS: A total of 11,972 adults and 7298 pediatrics were included for this analysis. Adult and pediatric curves were generated by sex and by ethnicity (non-Hispanic White, non-Hispanic Black, Hispanic, Asian, Other) and were derived as a function of age. CONCLUSIONS: These results show the ability to generate VAT and SAT reference data for GEHC systems using Hologic DXA data representative of the US youth and adult population.


Asunto(s)
Composición Corporal , Grasa Intraabdominal , Adulto , Adolescente , Humanos , Niño , Absorciometría de Fotón/métodos , Encuestas Nutricionales , Grasa Intraabdominal/diagnóstico por imagen , Etnicidad , Tejido Adiposo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...