Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Nat Med ; 30(7): 1832-1833, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38918631
2.
J Clin Transl Endocrinol ; 36: 100352, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38860154

RESUMEN

Objectives: To report the safety and side effects associated with taking verapamil for beta-cell preservation in children with newly-diagnosed T1D. Research Design and Methods: Eighty-eight participants aged 8.5 to 17.9 years weighing ≥ 30 kg were randomly assigned to verapamil (N = 47) or placebo (N = 41) within 31 days of T1D diagnosis and followed for 12 months from diagnosis, main CLVer study. Drug dosing was weight-based with incremental increases to full dosage. Side effect monitoring included serial measurements of pulse, blood pressure, liver enzymes, and electrocardiograms (ECGs). At study end, participants were enrolled in an observational extension study (CLVerEx), which is ongoing. No study drug is provided during the extension, but participants may use verapamil if prescribed by their diabetes care team. Results: Overall rates of adverse events were low and comparable between verapamil and placebo groups. There was no difference in the frequency of liver function abnormalities. Three CLVer participants reduced or discontinued medication due to asymptomatic ECG changes. One CLVerEx participant (18 years old), treated with placebo during CLVer, who had not had a monitoring ECG, experienced complete AV block with a severe hypotensive episode 6 weeks after reaching his maximum verapamil dose following an inadvertent double dose on the day of the event. Conclusions: The use of verapamil in youth newly-diagnosed with T1D appears generally safe and well tolerated with appropriate monitoring. We strongly recommend monitoring for potential side effects including an ECG at screening and an additional ECG once full dosage is reached.ClinicalTrials.gov number: NCT04233034.

3.
JMIR Pediatr Parent ; 7: e57198, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38889077

RESUMEN

Background: Regular physical activity and exercise are fundamental components of a healthy lifestyle for youth living with type 1 diabetes (T1D). Yet, few youth living with T1D achieve the daily minimum recommended levels of physical activity. For all youth, regardless of their disease status, minutes of physical activity compete with other daily activities, including digital gaming. There is an emerging area of research exploring whether digital games could be displacing other physical activities and exercise among youth, though, to date, no studies have examined this question in the context of youth living with T1D. Objective: We examined characteristics of digital gaming versus nondigital gaming (other exercise) sessions and whether youth with T1D who play digital games (gamers) engaged in less other exercise than youth who do not (nongamers), using data from the Type 1 Diabetes Exercise Initiative Pediatric study. Methods: During a 10-day observation period, youth self-reported exercise sessions, digital gaming sessions, and insulin use. We also collected data from activity wearables, continuous glucose monitors, and insulin pumps (if available). Results: The sample included 251 youths with T1D (age: mean 14, SD 2 y; self-reported glycated hemoglobin A1c level: mean 7.1%, SD 1.3%), of whom 105 (41.8%) were female. Youth logged 123 digital gaming sessions and 3658 other exercise (nondigital gaming) sessions during the 10-day observation period. Digital gaming sessions lasted longer, and youth had less changes in glucose and lower mean heart rates during these sessions than during other exercise sessions. Youth described a greater percentage of digital gaming sessions as low intensity (82/123, 66.7%) when compared to other exercise sessions (1104/3658, 30.2%). We had 31 youths with T1D who reported at least 1 digital gaming session (gamers) and 220 youths who reported no digital gaming (nongamers). Notably, gamers engaged in a mean of 86 (SD 43) minutes of other exercise per day, which was similar to the minutes of other exercise per day reported by nongamers (mean 80, SD 47 min). Conclusions: Digital gaming sessions were longer in duration, and youth had less changes in glucose and lower mean heart rates during these sessions when compared to other exercise sessions. Nevertheless, gamers reported similar levels of other exercise per day as nongamers, suggesting that digital gaming may not fully displace other exercise among youth with T1D.

4.
Diabet Med ; 41(8): e15332, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38751219

RESUMEN

Diabetes is unique among chronic diseases because clinical outcomes are intimately tied to how the person living with diabetes reacts to and implements treatment recommendations. It is further characterised by widespread social stigma, judgement and paternalism. This physical, social and psychological burden collectively influences self-management behaviours. It is widely recognised that the individual's perspective about the impact of trying to manage the disease and the burden that self-management confers must be addressed to achieve optimal health outcomes. Standardised, rigorous assessment of mental and behavioural health status, in interaction with physical health outcomes is crucial to aid understanding of person-reported outcomes (PROs). Whilst tempting to conceptualise PROs as an issue of perceived quality of life (QoL), in fact health-related QoL is multi-dimensional and covers indicators of physical or functional health status, psychological and social well-being. This complexity is illuminated by the large number of person reported outcome measures (PROMs) that have been developed across multiple psychosocial domains. Often measures are used inappropriately or because they have been used in the scientific literature rather than based on methodological or outcome assessment rigour. Given the broad nature of psychosocial functioning/mental health, it is important to broadly define PROs that are evaluated in the context of therapeutic interventions, real-life and observational studies. This report summarises the central themes and lessons derived in the assessment and use of PROMs amongst adults with diabetes. Effective assessment of PROMs routinely in clinical research is crucial to understanding the true impact of any intervention. Selecting appropriate measures, relevant to the specific factors of PROs important in the research study will provide valuable data alongside physical health data.


Asunto(s)
Diabetes Mellitus , Medición de Resultados Informados por el Paciente , Calidad de Vida , Humanos , Diabetes Mellitus/terapia , Diabetes Mellitus/psicología , Adulto , Consenso , Estado de Salud
5.
Artículo en Inglés | MEDLINE | ID: mdl-38669475

RESUMEN

Objective: To predict hypoglycemia and hyperglycemia risk during and after activity for adolescents with type 1 diabetes (T1D) using real-world data from the Type 1 Diabetes Exercise Initiative Pediatric (T1DEXIP) study. Methods: Adolescents with T1D (n = 225; [mean ± SD] age = 14 ± 2 years; HbA1c = 7.1 ± 1.3%; T1D duration = 5 ± 4 years; 56% using hybrid closed loop), wearing continuous glucose monitors (CGMs), logged 3738 total activities over 10 days. Repeated Measures Random Forest (RMRF) and Repeated Measures Logistic Regression (RMLR) models were used to predict a composite risk of hypoglycemia (<70 mg/dL) and hyperglycemia (>250 mg/dL) within 2 h after starting exercise. Results: RMRF achieved high precision predicting composite risk and was more accurate than RMLR Area under the receiver operating characteristic curve (AUROC 0.737 vs. 0.661; P < 0.001). Activities with minimal composite risk had a starting glucose between 132 and 160 mg/dL and a glucose rate of change at activity start between -0.4 and -1.9 mg/dL/min. Time <70 mg/dL and time >250 mg/dL during the prior 24 h, HbA1c level, and insulin on board at activity start were also predictive. Separate models explored factors at the end of activity; activities with glucose between 128 and 133 mg/dL and glucose rate of change between 0.4 and -0.6 mg/dL/min had minimal composite risk. Conclusions: Physically active adolescents with T1D should aim to start exercise with an interstitial glucose between 130 and 160 mg/dL with a flat or slightly decreasing CGM trend to minimize risk for developing dysglycemia. Incorporating factors such as historical glucose and insulin can improve prediction modeling for the acute glucose responses to exercise.

7.
Diabetes Care ; 47(5): 849-857, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38412033

RESUMEN

OBJECTIVE: To explore 24-h postexercise glycemia and hypoglycemia risk, data from the Type 1 Diabetes Exercise Initiative Pediatric (T1DEXIP) study were analyzed to examine factors that may influence glycemia. RESEARCH DESIGN AND METHODS: This was a real-world observational study with participant self-reported physical activity, food intake, and insulin dosing (multiple daily injection users). Heart rate, continuous glucose data, and available pump data were collected. RESULTS: A total of 251 adolescents (42% females), with a mean ± SD age of 14 ± 2 years, and hemoglobin A1c (HbA1c) of 7.1 ± 1.3% (54 ± 14.2 mmol/mol), recorded 3,319 activities over ∼10 days. Trends for lower mean glucose after exercise were observed in those with shorter disease duration and lower HbA1c; no difference by insulin delivery modality was identified. Larger glucose drops during exercise were associated with lower postexercise mean glucose levels, immediately after activity (P < 0.001) and 12 to <16 h later (P = 0.02). Hypoglycemia occurred on 14% of nights following exercise versus 12% after sedentary days. On nights following exercise, more hypoglycemia occurred when average total activity was ≥60 min/day (17% vs. 8% of nights, P = 0.01) and on days with longer individual exercise sessions. Higher nocturnal hypoglycemia rates were also observed in those with longer disease duration, lower HbA1c, conventional pump use, and if time below range was ≥4% in the previous 24 h. CONCLUSIONS: In this large real-world pediatric exercise study, nocturnal hypoglycemia was higher on nights when average activity duration was higher. Characterizing both participant- and event-level factors that impact glucose in the postexercise recovery period may support development of new guidelines, decision support tools, and refine insulin delivery algorithms to better support exercise in youth with diabetes.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Adolescente , Niño , Femenino , Humanos , Masculino , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Ejercicio Físico/fisiología , Glucosa , Hemoglobina Glucada , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Insulina Regular Humana
8.
Diabetes Technol Ther ; 26(S3): 53-65, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38377315

RESUMEN

Objective: Pivotal trials of automated insulin delivery (AID) closed-loop systems have demonstrated a consistent picture of glycemic benefit, supporting approval of multiple systems by the Food and Drug Administration or Conformité Européenne mark receipt. To assess how pivotal trial findings translate to commercial AID use, a systematic review of retrospective real-world studies was conducted. Methods: PubMed and EMBASE were searched for articles published after 2018 with more than five nonpregnant individuals with type 1 diabetes (T1D). Data were screened/extracted in duplicate for sample size, AID system, glycemic outcomes, and time in automation. Results: Of 80 studies identified, 20 met inclusion criteria representing 171,209 individuals. Time in target range 70-180 mg/dL (3.9-10.0 mmol/L) was the primary outcome in 65% of studies, with the majority of reports (71%) demonstrating a >10% change with AID use. Change in hemoglobin A1c (HbA1c) was reported in nine studies (range 0.1%-0.9%), whereas four reported changes in glucose management indicator (GMI) with a 0.1%-0.4% reduction noted. A decrease in HbA1c or GMI of >0.2% was achieved in two-thirds of the studies describing change in HbA1c and 80% of articles where GMI was described. Time below range <70 mg/dL (<3.9 mmol/L) was reported in 16 studies, with all but 1 study showing stable or reduced levels. Most systems had >90% time in automation. Conclusion: With larger and more diverse populations, and follow-up periods of longer duration (∼9 months vs. 3-6 months for pivotal trials), real-world retrospective analyses confirm pivotal trial findings. Given the glycemic benefits demonstrated, AID is rapidly becoming the standard of care for all people living with T1D. Individuals should be informed of these systems and differences between them, have access to and coverage for these technologies, and receive support as they integrate this mode of insulin delivery into their lives.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38375861

RESUMEN

Background: The Omnipod® 5 Automated Insulin Delivery System was associated with favorable glycemic outcomes for people with type 1 diabetes (T1D) in two pivotal clinical trials. Real-world evidence is needed to explore effectiveness in nonstudy conditions. Methods: A retrospective analysis of the United States Omnipod 5 System users (aged ≥2 years) with T1D and sufficient data (≥90 days of data; ≥75% of days with ≥220 continuous glucose monitor readings/day) available in Insulet Corporation's device and person-reported datasets as of July 2023 was performed. Target glucose setting usage (i.e., 110-150 mg/dL in 10 mg/dL increments) was summarized and glycemic outcomes were examined. Subgroup analyses of those using the lowest average glucose target (110 mg/dL) and stratification by baseline characteristics (e.g., age, prior therapy, health insurance coverage) were conducted. Results: In total, 69,902 users were included. Multiple and higher glucose targets were more commonly used in younger age groups. Median percentage of time in range (TIR; 70-180 mg/dL) was 68.8%, 61.3%, and 53.6% for users with average glucose targets of 110, 120, and 130-150 mg/dL, respectively, with minimal time <70 mg/dL (all median <1.13%). Among those with an average glucose target of 110 mg/dL (n = 37,640), median TIR was 65.0% in children and adolescents (2-17 years) and 69.9% in adults (≥18 years). Subgroup analyses of users transitioning from Omnipod DASH or multiple daily injections and of Medicaid/Medicare users demonstrated favorable glycemic outcomes among these groups. Conclusion: These glycemic outcomes from a large and diverse sample of nearly 70,000 children and adults demonstrate effective use of the Omnipod 5 System under real-world conditions.

10.
Diabetes Care ; 47(6): 941-947, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38295397

RESUMEN

OBJECTIVE: To determine how diabetes technologies, including continuous glucose monitoring (CGM) and automated insulin delivery (AID) systems, impact glycemic metrics, prevalence of severe hypoglycemic events (SHEs), and impaired awareness of hypoglycemia (IAH) in people with type 1 diabetes in a real-world setting within the U.S. RESEARCH DESIGN AND METHODS: In this retrospective, observational study with cross-sectional elements, participants aged ≥18 years were enrolled from the T1D Exchange Registry/online community. Participants completed a one-time online survey describing glycemic metrics, SHEs, and IAH. The primary objective was to determine the proportions of participants who reported achieving glycemic targets (assessed according to self-reported hemoglobin A1c) and had SHEs and/or IAH. We performed additional subgroup analyses focusing on the impact of CGM and insulin delivery modality. RESULTS: A total of 2,074 individuals with type 1 diabetes were enrolled (mean ± SD age 43.0 ± 15.6 years and duration of type 1 diabetes 26.3 ± 15.3 years). The majority of participants (91.7%) were using CGM, with one-half (50.8%) incorporating AID. Despite high use of diabetes technologies, only 57.7% reported achieving glycemic targets (hemoglobin A1c <7%). SHEs and IAH still occurred, with ∼20% of respondents experiencing at least one SHE within the prior 12 months and 30.7% (95% CI 28.7, 32.7) reporting IAH, regardless of CGM or AID use. CONCLUSIONS: Despite use of advanced diabetes technologies, a high proportion of people with type 1 diabetes do not achieve glycemic targets and continue to experience SHEs and IAH, suggesting an ongoing need for improved treatment strategies.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Estudios Transversales , Femenino , Adulto , Masculino , Hipoglucemia/epidemiología , Persona de Mediana Edad , Estudios Retrospectivos , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Insulina/administración & dosificación , Glucemia/metabolismo , Hemoglobina Glucada/metabolismo , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación
11.
Diabetes Technol Ther ; 26(6): 383-393, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38277156

RESUMEN

Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hemoglobina Glucada , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Preescolar , Insulina/administración & dosificación , Insulina/uso terapéutico , Femenino , Masculino , Glucemia/análisis , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada/análisis , Hipoglucemia/prevención & control , Resultado del Tratamiento , Control Glucémico/métodos , Automonitorización de la Glucosa Sanguínea
12.
Nutrients ; 16(1)2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38201991

RESUMEN

We explored the association between macronutrient intake and postprandial glucose variability in a large sample of youth living with T1D and consuming free-living meals. In the Type 1 Diabetes Exercise Initiative Pediatric (T1DEXIP) Study, youth took photographs before and after their meals on 3 days during a 10 day observation period. We used the remote food photograph method to obtain the macronutrient content of youth's meals. We also collected physical activity, continuous glucose monitoring, and insulin use data. We measured glycemic variability using standard deviation (SD) and coefficient of variation (CV) of glucose for up to 3 h after meals. Our sample included 208 youth with T1D (mean age: 14 ± 2 years, mean HbA1c: 54 ± 14.2 mmol/mol [7.1 ± 1.3%]; 40% female). We observed greater postprandial glycemic variability (SD and CV) following meals with more carbohydrates. In contrast, we observed less postprandial variability following meals with more fat (SD and CV) and protein (SD only) after adjusting for carbohydrates. Insulin modality, exercise after meals, and exercise intensity did not influence associations between macronutrients and postprandial glycemic variability. To reduce postprandial glycemic variability in youth with T1D, clinicians should encourage diversified macronutrient meal content, with a goal to approximate dietary guidelines for suggested carbohydrate intake.


Asunto(s)
Diabetes Mellitus Tipo 1 , Glucosa , Adolescente , Femenino , Humanos , Niño , Masculino , Automonitorización de la Glucosa Sanguínea , Glucemia , Comidas , Insulina
13.
Diabetes Care ; 47(1): 132-139, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37922335

RESUMEN

OBJECTIVE: Data from the Type 1 Diabetes Exercise Initiative Pediatric (T1DEXIP) study were evaluated to understand glucose changes during activity and identify factors that may influence changes. RESEARCH DESIGN AND METHODS: In this real-world observational study, adolescents with type 1 diabetes self-reported physical activity, food intake, and insulin dosing (multiple-daily injection users) using a smartphone application. Heart rate and continuous glucose monitoring data were collected, as well as pump data downloads. RESULTS: Two hundred fifty-one adolescents (age 14 ± 2 years [mean ± SD]; HbA1c 7.1 ± 1.3% [54 ± 14.2 mmol/mol]; 42% female) logged 3,738 activities over ∼10 days of observation. Preactivity glucose was 163 ± 66 mg/dL (9.1 ± 3.7 mmol/L), dropping to 148 ± 66 mg/dL (8.2 ± 3.7 mmol/L) by end of activity; median duration of activity was 40 min (20, 75 [interquartile range]) with a mean and peak heart rate of 109 ± 16 bpm and 130 ± 21 bpm. Drops in glucose were greater in those with lower baseline HbA1c levels (P = 0.002), shorter disease duration (P = 0.02), less hypoglycemia fear (P = 0.04), and a lower BMI (P = 0.05). Event-level predictors of greater drops in glucose included self-classified "noncompetitive" activities, insulin on board >0.05 units/kg body mass, glucose already dropping prior to the activity, preactivity glucose >150 mg/dL (>8.3 mmol/L) and time 70-180 mg/dL >70% in the 24 h before the activity (all P < 0.001). CONCLUSIONS: Participant-level and activity event-level factors can help predict the magnitude of drop in glucose during real-world physical activity in youth with type 1 diabetes. A better appreciation of these factors may improve decision support tools and self-management strategies to reduce activity-induced dysglycemia in active adolescents living with the disease.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Adolescente , Femenino , Niño , Masculino , Glucemia , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Insulina/uso terapéutico , Insulina Regular Humana , Ejercicio Físico/fisiología , Hipoglucemiantes/uso terapéutico
14.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37850941

RESUMEN

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Niño , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Hemoglobina Glucada , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea
15.
Diabetologia ; 67(2): 236-245, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38041737

RESUMEN

People living with diabetes have many medical devices available to assist with disease management. A critical aspect that must be considered is how systems for continuous glucose monitoring and insulin pumps communicate with each other and how the data generated by these devices can be downloaded, integrated, presented and used. Not only is interoperability associated with practical challenges, but also devices must adhere to all aspects of regulatory and legal frameworks. Key issues around interoperability in terms of data ownership, privacy and the limitations of interoperability include where the responsibility/liability for device and data interoperability lies and the need for standard data-sharing protocols to allow the seamless integration of data from different sources. There is a need for standardised protocols for the open and transparent handling of data and secure integration of data into electronic health records. Here, we discuss the current status of interoperability in medical devices and data used in diabetes therapy, as well as regulatory and legal issues surrounding both device and data interoperability, focusing on Europe (including the UK) and the USA. We also discuss a potential future landscape in which a clear and transparent framework for interoperability and data handling also fulfils the needs of people living with diabetes and healthcare professionals.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus , Humanos , Glucemia , Diabetes Mellitus/tratamiento farmacológico , Registros Electrónicos de Salud , Reino Unido
16.
Diabetes Technol Ther ; 25(11): 755-764, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37782145

RESUMEN

Background: During MiniMed™ advanced hybrid closed-loop (AHCL) use by adolescents and adults in the pivotal trial, glycated hemoglobin (A1C) was significantly reduced, time spent in range (TIR) was significantly increased, and there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA). The present study investigated the same primary safety and effectiveness endpoints during AHCL use by a younger cohort with type 1 diabetes (T1D). Methods: An intention-to-treat population (N = 160, aged 7-17 years) with T1D was enrolled in a single-arm study at 13 investigational centers. There was a run-in period (∼25 days) using HCL or sensor-augmented pump with/without predictive low-glucose management, followed by a 3-month study period with AHCL activated at two glucose targets (GTs; 100 and 120 mg/dL) for ∼45 days each. The mean ± standard deviation values of A1C, TIR, mean sensor glucose (SG), coefficient of variation (CV) of SG, time at SG ranges, and insulin delivered between run-in and study were analyzed (Wilcoxon signed-rank test or t-test). Results: Compared with baseline, AHCL use was associated with reduced A1C from 7.9 ± 0.9% (N = 160) to 7.4 ± 0.7% (N = 136) (P < 0.001) and overall TIR increased from the run-in 59.4 ± 11.8% to 70.3 ± 6.5% by end of study (P < 0.001), without change in CV, time spent below range (TBR) <70 mg/dL, or TBR <54 mg/dL. Relative to longer active insulin time (AIT) settings (N = 52), an AIT of 2 h (N = 19) with the 100 mg/dL GT increased mean TIR to 73.4%, reduced TBR <70 mg/dL from 3.5% to 2.2%, and reduced time spent above range (TAR) >180 mg/dL from 28.7% to 24.4%. During AHCL use, there was no severe hypoglycemia or DKA. Conclusions: In children and adolescents with T1D, MiniMed AHCL system use was safe, A1C was lower, and TIR was increased. The lowest GT and shortest AIT were associated with the highest TIR and lowest TBR and TAR, all of which met consensus-recommended glycemic targets. ClinicalTrials.gov ID: NCT03959423.


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Hipoglucemia , Adolescente , Adulto , Niño , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Cetoacidosis Diabética/etiología , Glucosa , Hemoglobina Glucada , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemia/complicaciones , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Resultado del Tratamiento
17.
Commun Med (Lond) ; 3(1): 132, 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37794113

RESUMEN

BACKGROUND: The greatest change in the treatment of people living with type 1 diabetes in the last decade has been the explosion of technology assisting in all aspects of diabetes therapy, from glucose monitoring to insulin delivery and decision making. As such, the aim of our systematic review was to assess the utility of these technologies as well as identify any precision medicine-directed findings to personalize care. METHODS: Screening of 835 peer-reviewed articles was followed by systematic review of 70 of them (focusing on randomized trials and extension studies with ≥50 participants from the past 10 years). RESULTS: We find that novel technologies, ranging from continuous glucose monitoring systems, insulin pumps and decision support tools to the most advanced hybrid closed loop systems, improve important measures like HbA1c, time in range, and glycemic variability, while reducing hypoglycemia risk. Several studies included person-reported outcomes, allowing assessment of the burden or benefit of the technology in the lives of those with type 1 diabetes, demonstrating positive results or, at a minimum, no increase in self-care burden compared with standard care. Important limitations of the trials to date are their small size, the scarcity of pre-planned or powered analyses in sub-populations such as children, racial/ethnic minorities, people with advanced complications, and variations in baseline glycemic levels. In addition, confounders including education with device initiation, concomitant behavioral modifications, and frequent contact with the healthcare team are rarely described in enough detail to assess their impact. CONCLUSIONS: Our review highlights the potential of technology in the treatment of people living with type 1 diabetes and provides suggestions for optimization of outcomes and areas of further study for precision medicine-directed technology use in type 1 diabetes.


In the last decade, there have been significant advances in how technology is used in the treatment of people living with type 1 diabetes. These technologies primarily aim to help manage blood sugar levels. Here, we reviewed research published over the last decade to evaluate the impact of such technologies on type 1 diabetes treatment. We find that various types of novel technologies, such as devices to monitor blood sugar levels continuously or deliver insulin, improve important diabetes-related measures and can reduce the risk of having low blood sugar levels. Importantly, several studies showed a positive impact of technologies on quality of life in people living with diabetes. Our findings highlight the benefits of novel technologies in the treatment of type 1 diabetes and identify areas for further research to optimize and personalize diabetes care.

18.
J Clin Endocrinol Metab ; 109(1): 57-67, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-37572381

RESUMEN

CONTEXT: The value of continuous glucose monitoring (CGM) for monitoring autoantibody (AAB)-positive individuals in clinical trials for progression of type 1 diabetes (T1D) is unknown. OBJECTIVE: Compare CGM with oral glucose tolerance test (OGTT)-based metrics in prediction of T1D. METHODS: At academic centers, OGTT and CGM data from multiple-AAB relatives were evaluated for associations with T1D diagnosis. Participants were multiple-AAB-positive individuals in a TrialNet Pathway to Prevention (TN01) CGM ancillary study (n = 93). The intervention was CGM for 1 week at baseline, 6 months, and 12 months. Receiver operating characteristic (ROC) curves of CGM and OGTT metrics for prediction of T1D were analyzed. RESULTS: Five of 7 OGTT metrics and 29/48 CGM metrics but not HbA1c differed between those who subsequently did or did not develop T1D. ROC area under the curve (AUC) of individual CGM values ranged from 50% to 69% and increased when adjusted for age and AABs. However, the highest-ranking metrics were derived from OGTT: 4/7 with AUC ∼80%. Compared with adjusted multivariable models using CGM data, OGTT-derived variables, Index60 and DPTRS (Diabetes Prevention Trial-Type 1 Risk Score), had higher discriminative ability (higher ROC AUC and positive predictive value with similar negative predictive value). CONCLUSION: Every 6-month CGM measures in multiple-AAB-positive individuals are predictive of subsequent T1D, but less so than OGTT-derived variables. CGM may have feasibility advantages and be useful in some settings. However, our data suggest there is insufficient evidence to replace OGTT measures with CGM in the context of clinical trials.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/diagnóstico , Prueba de Tolerancia a la Glucosa , Glucemia/metabolismo , Autoanticuerpos , Automonitorización de la Glucosa Sanguínea , Monitoreo Continuo de Glucosa
19.
Diabetes Technol Ther ; 25(9): 652-658, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37252734

RESUMEN

Background: Safety and significant improvement in overall glycated hemoglobin (A1C) and percentage of time spent in (TIR), below (TBR), and above (TAR) glucose range were demonstrated in the pivotal trial of adolescents and adults using the MiniMed™ advanced hybrid closed-loop (AHCL) system with the adjunctive, calibration-required Guardian™ Sensor 3. The present study evaluated early outcomes of continued access study (CAS) participants who transitioned from the pivotal trial investigational system to the approved MiniMed™ 780G system with the non-adjunctive, calibration-free Guardian™ 4 Sensor (MM780G+G4S). Study data were presented alongside those of real-world MM780G+G4S users from Europe, the Middle East, and Africa. Methods: The CAS participants (N = 109, aged 7-17 years and N = 67, aged >17 years) used the MM780G+G4S for 3 months and data of real-world MM780G+G4S system users (N = 10,204 aged ≤15 years and N = 26,099 aged >15 years) were uploaded from September 22, 2021 to December 02, 2022. At least 10 days of real-world continuous glucose monitoring (CGM) data were required for analyses. Glycemic metrics, delivered insulin and system use/interactions underwent descriptive analyses. Results: Time in AHCL and CGM use were >90% for all groups. AHCL exits averaged 0.1/day and there were few blood glucose measurements (BGMs) (0.8/day-1.0/day). Adults in both cohorts met most consensus recommendations for glycemic targets. Pediatric groups met recommendations for %TIR and %TBR, although not those for mean glucose variability and %TAR, possibly due to low use of recommended glucose target (100 mg/dL) and active insulin time (2 h) settings (28.4% in the CAS cohort and 9.4% in the real-world cohort). The CAS pediatric and adult A1C were 7.2% ± 0.7% and 6.8% ± 0.7%, respectively, and there were no serious adverse events. Conclusions: Early clinical use of the MM780G+G4S was safe and involved minimal BGMs and AHCL exits. Consistent with real-world pediatric and adult use, outcomes were associated with achievement of recommended glycemic targets. Clinical Trial Registration number: NCT03959423.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Niño , Humanos , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa , Hemoglobina Glucada , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina
20.
Diabet Med ; 40(10): e15123, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37078999

RESUMEN

BACKGROUND: In youth with type 1 diabetes (T1D), high haemoglobin A1c (HbA1c) levels are associated with an increased risk for diabetic ketoacidosis (DKA). AIMS: This study examined whether daily school-supervised basal insulin injections were feasible and if they reduced the risk of morning ketosis in children and adolescents with high HbA1c levels. We hypothesized that supervised glargine and degludec would reduce the risk of ketosis and that the prolonged action of degludec would protect from ketosis after consecutive days of unsupervised injections. MATERIALS & METHODS: After a 2-4-week run-in, youth (10-18 years, HbA1c ≥ 8.5%) managing T1D with injections were randomized to school-supervised administration of degludec or glargine for 4 months. School nurses observed daily blood ß-hydroxybutyrate (BHB) and glucose checks. During COVID closures, the research team supervised procedures remotely. RESULTS: Data from 28 youth (age 14.3 ± 2.3 years, HbA1c 11.4 ± 1.9%, 64% F) were analysed. School-supervised injections of both basal insulins for 1-4 days progressively lowered the percent of participants with elevated BHB. The percent of participants with elevated BHB (≥0.6 mmol/L) after 2 days of unsupervised basal insulin doses at home was greater in the glargine than degludec group but had a high p-value (17.2% vs. 9.0%, p = 0.3). HbA1c was unchanged in both groups. DISCUSSION: In youth with T1D at high risk for DKA, daily supervised long-acting insulin administration decreased the probability of elevated ketone levels on subsequent school days, regardless of basal insulin type. A larger sample size may have demonstrated that the longer action profile of degludec would offer additional protection from ketosis during days of not attending school. CONCLUSION: Engaging school-based caregivers in management of youth with T1D on injected insulin may decrease clinically significant ketosis and minimize acute complications of diabetes.


Asunto(s)
COVID-19 , Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Neoplasias , Niño , Humanos , Adolescente , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina Glargina , Hemoglobina Glucada , Hipoglucemiantes , Proyectos Piloto , Insulina/uso terapéutico , Glucemia/análisis , Cetoacidosis Diabética/epidemiología , Cetoacidosis Diabética/prevención & control , Cetoacidosis Diabética/inducido químicamente , Neoplasias/inducido químicamente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...