Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Colorectal Dis ; 26(6): 1271-1284, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38750621

RESUMEN

AIM: Although proximal faecal diversion is standard of care to protect patients with high-risk colorectal anastomoses against septic complications of anastomotic leakage, it is associated with significant morbidity. The Colovac device (CD) is an intraluminal bypass device intended to avoid stoma creation in patients undergoing low anterior resection. A preliminary study (SAFE-1) completed in three European centres demonstrated 100% protection of colorectal anastomoses in 15 patients, as evidenced by the absence of faeces below the CD. This phase III trial (SAFE-2) aims to evaluate the safety and effectiveness of the CD in a larger cohort of patients undergoing curative rectal cancer resection. METHODS: SAFE-2 is a pivotal, multicentre, prospective, open-label, randomized, controlled trial. Patients will be randomized in a 1:1 ratio to either the CD arm or the diverting loop ileostomy arm, with a recruitment target of 342 patients. The co-primary endpoints are the occurrence of major postoperative complications within 12 months of index surgery and the effectiveness of the CD in reducing stoma creation rates. Data regarding quality of life and patient's acceptance and tolerance of the device will be collected. DISCUSSION: SAFE-2 is a multicentre randomized, control trial assessing the efficacy and the safety of the CD in protecting low colorectal anastomoses created during oncological resection relative to standard diverting loop ileostomy. TRIAL REGISTRATION: NCT05010850.


Asunto(s)
Anastomosis Quirúrgica , Fuga Anastomótica , Colon , Neoplasias del Recto , Recto , Humanos , Anastomosis Quirúrgica/instrumentación , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Fuga Anastomótica/prevención & control , Estudios Prospectivos , Neoplasias del Recto/cirugía , Recto/cirugía , Colon/cirugía , Femenino , Masculino , Resultado del Tratamiento , Ileostomía/instrumentación , Ileostomía/efectos adversos , Ileostomía/métodos , Persona de Mediana Edad , Calidad de Vida , Adulto , Anciano , Proctectomía/efectos adversos , Proctectomía/métodos , Proctectomía/instrumentación , Complicaciones Posoperatorias/prevención & control
2.
Surg Laparosc Endosc Percutan Tech ; 33(2): 207-210, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36971520

RESUMEN

INTRODUCTION: Anastomotic margin tissue perfusion is recognized as critical to successful colorectal anastomosis creation. Near-infrared (NIR) fluorescence imaging with indocyanine green (ICG) is the most common modality used by surgeons as an adjunct to clinical assessment in confirming the adequacy of tissue perfusion. Tissue oxygenation as a surrogate for tissue perfusion has been described in a variety of surgical specialties but its use in colorectal surgery has been limited. Here, we report our experience using a handheld tissue-oxygen meter, IntraOx, for the evaluation of colorectal tissue bed oxygen saturation (StO 2 ) and compared its utility with NIR-ICG in identifying the viability of colonic tissue before anastomosis in a range of colorectal procedures. MATERIALS AND METHODS: This was an institutional review board-approved multicenter trial consisting of 100 patients undergoing elective colon resections. After specimen mobilization, a clinical margin was chosen based on the oncologic, anatomic, and clinical assessment as per the clinicians' standard technique. The IntraOx device was then used to take a baseline reading of colonic tissue oxygenation on a normal segment of perfused colon. Following this, measurements were taken circumferentially at 5 cm intervals along the bowel proximally and distally to the clinical margin. A StO 2 margin was then determined based on the point at which the StO 2 dropped off by ≥10 percentage points. This was then compared with the NIR-ICG margin using the Spy-Phi system. RESULTS: StO 2 was found to have a sensitivity and specificity of 94.8% and 93.1%, respectively, and a positive predictive value and negative predictive value of 93.5% and 94.5%, respectively when compared with NIR-ICG. At the 4-week follow-up, no significant complications or leaks were reported. CONCLUSIONS: The IntraOx handheld device was found to be similar to NIR-ICG in identifying a well-perfused margin of colonic tissue while having the added benefits of high portability and reduced costs. Further studies looking at the effect of the IntraOx on preventing colonic anastomotic complications such as leak and stricture are warranted.


Asunto(s)
Neoplasias Colorrectales , Laparoscopía , Humanos , Verde de Indocianina/farmacología , Fuga Anastomótica/etiología , Colorantes/farmacología , Laparoscopía/métodos , Anastomosis Quirúrgica/métodos , Colectomía/métodos , Perfusión/efectos adversos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/complicaciones , Oximetría
3.
Surgery ; 172(6S): S21-S28, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36427926

RESUMEN

BACKGROUND: Published empirical data have increasingly suggested that using near-infrared fluorescence cholangiography during laparoscopic cholecystectomy markedly increases biliary anatomy visualization. The technology is rapidly evolving, and different equipment and doses may be used. We aimed to identify areas of consensus and nonconsensus in the use of incisionless near-infrared fluorescent cholangiography during laparoscopic cholecystectomy. METHODS: A 2-round Delphi survey was conducted among 28 international experts in minimally invasive surgery and near-infrared fluorescent cholangiography in 2020, during which respondents voted on 62 statements on patient preparation and contraindications (n = 12); on indocyanine green administration (n = 14); on potential advantages and uses of near-infrared fluorescent cholangiography (n = 18); comparing near-infrared fluorescent cholangiography with intraoperative x-ray cholangiography (n = 7); and on potential disadvantages of and required training for near-infrared fluorescent cholangiography (n = 11). RESULTS: Expert consensus strongly supports near-infrared fluorescent cholangiography superiority over white light for the visualization of biliary structures and reduction of laparoscopic cholecystectomy risks. It also offers other advantages like enhancing anatomic visualization in obese patients and those with moderate to severe inflammation. Regarding indocyanine green administration, consensus was reached that dosing should be on a milligrams/kilogram basis, rather than as an absolute dose, and that doses >0.05 mg/kg are necessary. Although there is no consensus on the optimum preoperative timing of indocyanine green injections, the majority of participants consider it important to administer indocyanine green at least 45 minutes before the procedure to decrease the light intensity of the liver. CONCLUSION: Near-infrared fluorescent cholangiography experts strongly agree on its effectiveness and safety during laparoscopic cholecystectomy and that it should be used routinely, but further research is necessary to establish optimum timing and doses for indocyanine green.


Asunto(s)
Colecistectomía Laparoscópica , Verde de Indocianina , Humanos , Colecistectomía Laparoscópica/métodos , Colangiografía/métodos , Imagen Óptica , Colorantes
4.
Surgery ; 172(6S): S29-S37, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36427927

RESUMEN

BACKGROUND: Understanding the extent of tumor spread to local lymph nodes is critical to managing early-stage gastric cancer. Recently, fluorescence imaging with indocyanine green has been used to identify and characterize sentinel lymph nodes during gastric cancer surgery, but no published guidelines exist. We sought to identify areas of consensus among international experts in the use of fluorescence imaging with indocyanine green for mapping sentinel lymph nodes during gastric-cancer surgery. METHODS: In this 2-round, online Delphi survey, 27 international experts voted on 79 statements pertaining to patient preparation and contraindications to fluorescence imaging with indocyanine green during gastric cancer surgery; indications; technical aspects; advantages/disadvantages and limitations; and training and research. Methodological steps were adopted during survey design to minimize bias. RESULTS: Consensus was reached on 61 of 79 statements, including giving single injections of indocyanine green into each of the 4 quadrants peritumorally, administering indocyanine green on the same day as surgery, injecting a total of 1 to 5 mL of 5 mg/mL indocyanine green, injecting endoscopically into submucosa, and repeating indocyanine green injections a second time if sentinel lymph node visualization remains inadequate. Consensus also was reached that fluorescence imaging with indocyanine green is an acceptable single-agent modality for sentinel lymph node identification and that the sentinel lymph node basin method is preferred. However, sentinel lymph node dissection should be limited to T1 gastric cancer and tumors ≤4 cm in diameter, and further research is necessary to optimize the technique and render fluorescence-guided sentinel lymph nodes dissection acceptable for routine clinical use. CONCLUSION: Although considerable consensus was achieved, further research is necessary before this technology should be used in routine practice.


Asunto(s)
Ganglio Linfático Centinela , Neoplasias Gástricas , Humanos , Verde de Indocianina , Neoplasias Gástricas/diagnóstico por imagen , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/patología , Biopsia del Ganglio Linfático Centinela , Imagen Óptica/métodos , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/cirugía , Ganglio Linfático Centinela/patología
6.
Surgery ; 172(6S): S38-S45, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36427929

RESUMEN

BACKGROUND: Fluorescence imaging with indocyanine green is increasingly being used in colorectal surgery to assess anastomotic perfusion, and to detect sentinel lymph nodes. METHODS: In this 2-round, online, Delphi survey, 35 international experts were asked to vote on 69 statements pertaining to patient preparation and contraindications to fluorescence imaging during colorectal surgery, indications, technical aspects, potential advantages/disadvantages, and effectiveness versus limitations, and training and research. Methodological steps were adopted during survey design to minimize risk of bias. RESULTS: More than 70% consensus was reached on 60 of 69 statements, including moderate-strong consensus regarding fluorescence imaging's value assessing anastomotic perfusion and leak risk, but not on its value mapping sentinel nodes. Similarly, although consensus was reached regarding most technical aspects of its use assessing anastomoses, little consensus was achieved for lymph-node assessments. Evaluating anastomoses, experts agreed that the optimum total indocyanine green dose and timing are 5 to 10 mg and 30 to 60 seconds pre-evaluation, indocyanine green should be dosed milligram/kilogram, lines should be flushed with saline, and indocyanine green can be readministered if bright perfusion is not achieved, although how long surgeons should wait remains unknown. The only consensus achieved for lymph-node assessments was that 2 to 4 injection points are needed. Ninety-six percent and 100% consensus were reached that fluorescence imaging will increase in practice and research over the next decade, respectively. CONCLUSION: Although further research remains necessary, fluorescence imaging appears to have value assessing anastomotic perfusion, but its value for lymph-node mapping remains questionable.


Asunto(s)
Cirugía Colorrectal , Procedimientos Quirúrgicos del Sistema Digestivo , Humanos , Verde de Indocianina , Imagen Óptica , Biopsia del Ganglio Linfático Centinela
7.
Surgery ; 172(6S): S54-S59, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36427931

RESUMEN

BACKGROUND: Despite exponentially growing evidence supporting the use of intraoperative fluorescence imaging + indocyanine green dye, considerable variability exists in how and when it is used, and no published consensus guidelines exist. We have conducted Delphi surveys of international experts in the use of intraoperative fluorescence imaging covering 6 distinct surgical scenarios: laparoscopic cholecystectomy; colorectal, lymphedema, gastric cancer, and plastic surgery; and thyroid and parathyroid resections. Although each survey asked experts to vote on field-specific consensus statements, they also had 29 shared statements to permit some analysis spanning the 6 specialties. This article summarizes these results. METHODS: Data on the 29 shared statements from 6 two-round Delphi consensus surveys were compiled to identify areas of overall consensus and compare the different specialties. As with the individual surveys, consensus was defined as ≥70% intervoter agreement. RESULTS: Among 140 participating experts, overall consensus was achieved on 16 statements, including strong agreement that using indocyanine green is extremely safe, that it can be used even when informed written consent cannot be provided, that it significantly enhances anatomical visualization and impacts how procedures are performed, and that it significantly reduces overall procedural risk. However, indocyanine green dosing and timing are procedure-specific, with considerable variability persisting for some applications, and the overall consensus is that further research is necessary to optimize this facet of intraoperative fluorescence imaging. CONCLUSION: Fluorescence imaging is gaining traction across multiple surgical specialties as an invaluable intraoperative tool. Its use in clinical practice and research seems destined to increase.


Asunto(s)
Verde de Indocianina , Cirugía Plástica , Humanos , Imagen Óptica , Consenso , Etnicidad
8.
Cureus ; 14(3): e23370, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35475073

RESUMEN

Colonic lipomas are rare, benign neoplasms, typically asymptomatic, and predominantly found incidentally during autopsy or routine surveillance. Symptomatic lesions are usually those greater than 2 cm in diameter while "giant" lesions are characterized as those over 4 cm. Presentations can vary from asymptomatic to more severe sequelae, including obstruction, gastrointestinal bleeding, or intussusception. Resection of these lesions has historically been restricted to large or symptomatic lesions. However, recent reports suggest lipomas may retain the ability to grow and can become symptomatic over time despite being inconsequential initially. This series provides a review of the clinical manifestations of colonic lipomas, radiographic characteristics, and a treatment recommendation for management of these lesions using minimally invasive surgical techniques whilst advocating for consideration of resection prior to the development of symptoms or more emergent complications.

9.
Surg Endosc ; 36(3): 2192-2196, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34550436

RESUMEN

BACKGROUND: Adequate tissue oxygenation and perfusion remain fundamental to safe bowel resection surgery. Near infrared (NIR) imaging using indocyanine green has proven itself superior to clinical evaluation alone in assessing bowel perfusion, but requires expensive equipment not readily available in many centers. METHODS: We studied the IntraOx device (Vioptix Inc, Newark, CA USA), a handheld, tissue oxygen saturation assessment tool, to assess whether tissue bed oxygen saturation (StO2) is comparable to NIR assessment of bowel viability. Patients undergoing elective colon resection for benign and malignant disease were included. After choosing a clinical margin (CM) and dividing the mesentery, StO2 was measured at 5-cm intervals along the colon. A tissue oxygen saturation margin (TOM) was assigned where StO2 dropped off by at least 10 percentage points. NIR perfusion was then assessed to determine NIR margin (NIRM). Intraoperative and postoperative data were collected. RESULTS: 32 consecutive patients undergoing colectomies were analyzed. IntraOx sensitivity was 90.6%, specificity was 94.3%. The mean StO2 difference across the NIRM was 23.1%. In all but one case, the TOM matched the NIRM. In 3 cases, the TOM and NIRM concurred, but were a mean of 3.3 cm proximal to the CM and altered the surgical plan. At 4-week follow-up, no significant complications were reported. CONCLUSIONS: The IntraOx device consistently identified a margin of significant saturation "drop-off" which correlated with the findings on NIR perfusion and clinical assessment. These early data indicate that StO2 measurement may be equivalent to NIR assessment of bowel perfusion. In addition, the IntraOx device may be a more cost-effective solution for surgeons looking for adjunctive evaluation of bowel viability. More study is warranted in a larger group of patients to confirm these preliminary findings and to judge the impact of StO2 assessment on reducing anastomotic leaks.


Asunto(s)
Fuga Anastomótica , Verde de Indocianina , Anastomosis Quirúrgica/métodos , Fuga Anastomótica/etiología , Colectomía/métodos , Humanos , Oxígeno , Supervivencia Tisular
10.
Ann Surg ; 275(4): 685-691, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33214476

RESUMEN

BACKGROUND: In recent decades, the use of near-infrared light and fluorescence-guidance during open and laparoscopic surgery has exponentially expanded across various clinical settings. However, tremendous variability exists in how it is performed. OBJECTIVE: In this first published survey of international experts on fluorescence-guided surgery, we sought to identify areas of consensus and nonconsensus across 4 areas of practice: fundamentals; patient selection/preparation; technical aspects; and effectiveness and safety. METHODS: A Delphi survey was conducted among 19 international experts in fluorescence-guided surgery attending a 1-day consensus meeting in Frankfurt, Germany on September 8th, 2019. Using mobile phones, experts were asked to anonymously vote over 2 rounds of voting, with 70% and 80% set as a priori thresholds for consensus and vote robustness, respectively. RESULTS: Experts from 5 continents reached consensus on 41 of 44 statements, including strong consensus that near-infrared fluorescence-guided surgery is both effective and safe across a broad variety of clinical settings, including the localization of critical anatomical structures like vessels, detection of tumors and sentinel nodes, assessment of tissue perfusion and anastomotic leaks, delineation of segmented organs, and localization of parathyroid glands. Although the minimum and maximum safe effective dose of ICG were felt to be 1 to 2 mg and >10 mg, respectively, there was strong consensus that determining the optimum dose, concentration, route and timing of ICG administration should be an ongoing research focus. CONCLUSIONS: Although fluorescence imaging was almost unanimously perceived to be both effective and safe across a broad range of clinical settings, considerable further research remains necessary to optimize its use.


Asunto(s)
Verde de Indocianina , Ganglio Linfático Centinela , Consenso , Técnica Delphi , Humanos , Imagen Óptica/métodos
11.
Ann Transl Med ; 9(10): 908, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34164542

RESUMEN

The use of indocyanine green (ICG) fluorescence near-infrared (NIR) imaging during gastrointestinal surgery has surged in recent years. Its use in esophageal surgery is actively being studied both in the clinical setting and in the lab. NIR imaging has several important applications in esophageal surgery including assessing perfusion of the gastrointestinal-esophageal anastomosis, lymphatic drainage and tracheal blood flow after mediastinal dissection. This is a review of the modern literature summarizing the current knowledge on fluorescence-guided surgery of the esophagus.

12.
J Surg Case Rep ; 2020(11): rjaa445, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33214868

RESUMEN

HeartMate II left ventricular assist device (LVAD) assists heart failure patients by generating continuous flow via axial flow pump placed in the left ventricle. Little is known of the effect of continuous flow on intestinal anastomoses. This is the first case visually documenting altered perfusion patterns in patients with LVADs using indocyanine green (ICG). A 72-year-old male required a colon resection, for adenocarcinoma, following implantation of an LVAD. Perfusion of the anastomosis was evaluated using indocyanine. During the assessment, an unusual perfusion pattern was noticed. Normally, flow as measured by SPY is seen as an initial blush of contrast followed by a gradual, pulsatile increase in the progression of the indocyanine through the tissues. In this patient, instead of the usual initial blush, a continuous beam of ICG was seen to flow though the blood vessels. This novel perfusion pattern is consistent with flow generated from LVAD.

13.
J Laparoendosc Adv Surg Tech A ; 30(2): 103-109, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31166832

RESUMEN

Every field of surgery has seen an explosion of new technologies aimed at improving surgical technique and reducing complications. The use of near-infrared (NIR) fluorescence to assess perfusion has been described in several surgical disciplines. NIR provides the surgeon with real-time perfusion assessment of a target organ or anastomosis and can be invaluable in aiding decision-making during the index operation. In the following article we discuss the use of fluorescence-guided perfusion assessment during colonic interposition for esophageal replacement. To our knowledge this is the first description of the use of fluorescence-guided perfusion assessment during colonic interposition.


Asunto(s)
Anastomosis Quirúrgica/métodos , Colon/cirugía , Diagnóstico por Imagen/métodos , Procedimientos Quirúrgicos del Sistema Digestivo , Endoscopía/métodos , Esófago/cirugía , Fluorescencia , Colon/diagnóstico por imagen , Toma de Decisiones , Esófago/diagnóstico por imagen , Humanos , Rayos Infrarrojos , Perfusión , Complicaciones Posoperatorias
14.
J Surg Case Rep ; 2018(8): rjy204, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30094000

RESUMEN

Adenomyomatous hyperplasia (AH) is commonly found in the gallbladder and is considered a tumor-like inflammatory lesion arising from Rokitansky-Aschoff sinus. It is extremely rare in the extrahepatic bile duct and only 15 cases have been reported to date. We describe a 63-year-old male patient who presented with cholangitis, underwent an extensive diagnostic workup, and ultimately had a Whipple procedure. Final pathology showed a 2.0 × 1.5 × 0.5 cm3 granular lesion in the distal common bile duct. There was prominent biliary epithelial proliferation with tubular-papillary architecture and minimal nuclear atypia in association with chronic inflammation, stroma reaction and smooth muscle proliferation. AH of the extrahepatic bile duct is a benign process but often requires a major operation to definitively diagnose.

15.
J Thorac Dis ; 9(9): E767-E770, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29221339

RESUMEN

Peritoneopericardial diaphragmatic hernia is a rare entity involving herniation of abdominal viscera through the diaphragm into the pericardial sac. It is most often seen after blunt abdominal trauma, but can occur following any trans-diaphragmatic intervention. We report on a 56-year-old female with peritoneopericardial diaphragmatic hernia secondary to a convergent procedure for the treatment of atrial fibrillation, who underwent a laparoscopic repair. An anterior abdominal wall laparoscopic approach was employed. Transverse colon and greater omentum were within the hernia sac. The defect measuring 3 cm × 3 cm was repaired using a composite hernia mesh. The total operative time was 78 minutes. No intra-operative and no post-operative complications were observed. Patient remained asymptomatic at a 6-month follow-up. Laparoscopic mesh repair of peritoneopericardial diaphragmatic hernia is safe, feasible and is the procedure of choice for treating these complex hernias.

18.
J Am Coll Surg ; 220(1): 82-92.e1, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25451666

RESUMEN

BACKGROUND: Our primary objective was to demonstrate the utility and feasibility of the intraoperative assessment of colon and rectal perfusion using fluorescence angiography (FA) during left-sided colectomy and anterior resection. Anastomotic leak (AL) after colorectal resection increases morbidity, mortality, and, in cancer cases, recurrence rates. Inadequate perfusion may contribute to AL. The PINPOINT Endoscopic Fluorescence Imaging System allows for intraoperative assessment of anastomotic perfusion. STUDY DESIGN: This is a prospective, multicenter, open-label, clinical trial that assessed the feasibility and utility of FA for intraoperative perfusion assessment during left-sided colectomy and anterior resection at 11 centers in the United States. RESULTS: A total of 147 patients were enrolled, of whom 139 were eligible for analysis. Diverticulitis (44%), rectal cancer (25%), and colon cancer (21%) were the most prevalent indications for surgery. The mean level of anastomosis was 10 ± 4 cm from the anal verge. Splenic-flexure mobilization was performed in 81% and high ligation of the inferior mesenteric artery in 61.9% of patients. There was a 99% success rate for FA, and FA changed surgical plans in 11 (8%) patients, with the majority of changes occurring at the time of transection of the proximal margin (7%). Overall morbidity rates were 17%. The anastomotic leak rate was 1.4% (n = 2). There were no anastomotic leaks in the 11 patients who had a change in surgical plan based on intraoperative perfusion assessment with FA. CONCLUSIONS: PINPOINT is a safe and feasible tool for intraoperative assessment of tissue perfusion during colorectal resection. There were no anastomotic leaks in patients in whom the anastomosis was revised based on inadequate perfusion with FA.


Asunto(s)
Fuga Anastomótica/prevención & control , Colectomía/métodos , Colon/irrigación sanguínea , Cuidados Intraoperatorios/métodos , Laparoscopía/métodos , Imagen Óptica/métodos , Recto/irrigación sanguínea , Adulto , Anciano , Anciano de 80 o más Años , Fuga Anastomótica/etiología , Colon/cirugía , Estudios de Factibilidad , Femenino , Colorantes Fluorescentes , Humanos , Verde de Indocianina , Cuidados Intraoperatorios/instrumentación , Masculino , Persona de Mediana Edad , Imagen Óptica/instrumentación , Estudios Prospectivos , Recto/cirugía , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos , Resultado del Tratamiento
19.
Surg Innov ; 20(4): 411-3, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23060533

RESUMEN

The rigid sigmoidoscope is an important tool in a surgeon's armamentarium, yet it has remained essentially unchanged despite poor imaging and the inability to project or record the images. Herein we report our initial experience with a novel introducer built from readily available operating room supplies and designed to convert any standard laparoscope into a high-definition rigid sigmoidoscope.


Asunto(s)
Laparoscopios , Sigmoidoscopios , Sigmoidoscopía/instrumentación , Anastomosis Quirúrgica/instrumentación , Anastomosis Quirúrgica/métodos , Diseño de Equipo , Humanos , Neoplasias del Recto/cirugía , Sigmoidoscopía/métodos
20.
Surg Laparosc Endosc Percutan Tech ; 22(5): 433-6, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23047388

RESUMEN

The influence of perfusion on colorectal anastomotic healing and, conversely, the role of ischemia in anastomotic dehiscence have been reported by many investigators, and yet identifying a modality that can evaluate perfusion in real time and thus guide intraoperative management has proven elusive. This study describes our initial experience using transanal near-infrared (NIR) imaging to evaluate anastomotic perfusion after colorectal anastomoses. Patients undergoing colectomy with an anastomosis within 25 cm of the anal verge were included in this study. A transanal NIR system was used to assess mucosal perfusion at the level of the anastomoses. The rectum was easily navigated under direct vision and the anastomotic staple line visualized. High-quality NIR mucosal angiography was obtained in all subjects, confirming that transanal NIR angiography is feasible and simple to perform. Although NIR mucosal angiography is a promising modality, further study is needed to correlate this technique to the clinical outcome.


Asunto(s)
Canal Anal/cirugía , Colectomía/métodos , Colon/cirugía , Colonoscopía/métodos , Verde de Indocianina , Recto/cirugía , Anciano , Anciano de 80 o más Años , Canal Anal/patología , Anastomosis Quirúrgica/métodos , Colon/patología , Colorantes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recto/patología , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...