Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Dig Dis Sci ; 69(5): 1722-1730, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38594432

RESUMEN

INTRODUCTION: Patients with gastroparesis (Gp) have symptoms with or without a cyclic pattern. This retrospective study evaluates differences in cyclic vs. non-cyclic symptoms of Gp by analyzing mucosal electrogastrogram (mEG), familial dysautonomias, and response to gastric stimulation. METHODS: 37 patients with drug refractory Gp, 7 male and 30 female, with a mean age of 41.4 years, were studied. 18 had diabetes mellitus, 25 had cyclic (Cyc), and 12 had a non-cyclic (NoCyc) pattern of symptoms. Patients underwent temporary mucosal gastric stimulator (tGES) placement, which was done as a trial before permanent stimulator (GES) placement. Electrogastrogram (EGG) by mucosal (mEG) measures, including frequency, amplitude, and frequency-amplitude ratio (FAR), were pre- and post-tGES. Patients' history of personal and familial dysautonomias, quality of life, and symptom scores were recorded. Baseline vs. follow-ups were compared by paired t tests and McNemar's tests. T tests contrasted symptom scores, gastric emptying tests (GET), and mEG measures, while chi-squared tests deciphered comorbidity differences between two groups and univariate and multivariate analyses. RESULTS: There were significantly more patients with diabetes in the Cyc group vs. the NoCyc group. Using a 1 point in symptom outcome, 18 patients did not improve and 19 did improve with tGES. Using univariable analysis, with the cyclic pattern as a predictor, patients exhibiting a cyclic pattern had an odds ratio of 0.22 (95% CI 0.05-0.81, p = 0.054) for achieving an improvement of at least one unit in vomiting at follow-up from baseline. The mucosal electrogastrogram frequency to amplitude ratio (FAR) for the "not Improved" group was 19.6 [3.5, 33.6], whereas, for the "Improved" group, it was 54.3 [25.6, 72.5] with a p-value of 0.049. For multivariate logistic regression, accounting for sex and age squared, patients exhibiting a cyclic pattern had an adjusted odds ratio (OR) of 0.16 (95% CI 0.03-0.81, p = 0.027) for achieving an improvement of at least one unit in vomiting at follow-up from baseline. The two groups had no significant differences in the personal or inherited history of investigated familial patterns. CONCLUSION: This study shows differences in Gp patients with Cyc vs. NoCyc symptoms in several areas. Larger studies are needed to elicit further differences between the two groups about cycles of symptoms, EGG, findings, familial patterns, and response to mucosal GES.


Asunto(s)
Terapia por Estimulación Eléctrica , Vaciamiento Gástrico , Gastroparesia , Humanos , Gastroparesia/terapia , Gastroparesia/fisiopatología , Gastroparesia/diagnóstico , Femenino , Masculino , Adulto , Estudios Retrospectivos , Persona de Mediana Edad , Vaciamiento Gástrico/fisiología , Terapia por Estimulación Eléctrica/métodos , Resultado del Tratamiento
2.
Proc (Bayl Univ Med Cent) ; 36(1): 99-100, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36578602

RESUMEN

Takotsubo cardiomyopathy involves transient systolic dysfunction of the left ventricle thought to be caused by a physiologic stress response and associated catecholamine release. We present a previously undocumented cause of this stress response involving a 53-year-old man with hepatocellular carcinoma and alcohol-associated cirrhosis who initially presented for liver transplantation. Shortly after successful transplantation, the patient developed a COVID-19 infection and takotsubo cardiomyopathy.

3.
Ther Adv Gastrointest Endosc ; 15: 26317745221136775, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36531201

RESUMEN

Background: Clinically significant serrated polyp detection rate (CSSDR) and proximal serrated polyp detection rate (PSDR) have been suggested as the potential quality benchmarks for colonoscopy (CSSDR = 7% and PSDR = 11%) in comparison to the established benchmark adenoma detection rate (ADR). Another emerging milestone is the detection rate of lateral spreading lesions (LSLs). Objectives: This study aimed to evaluate CSSDR, PSDR, ADR, and LSL detection rates among gastrointestinal (GI) fellows performing a colonoscopy. A secondary aim was to evaluate patient factors associated with the detection rates of these lesions. Design and Methods: A retrospective review of 799 colonoscopy reports was performed. GI fellow details, demographic data, and pathology found on colonoscopy were collected. Multiple logistic regression analysis was performed to identify the factors associated with CSSDR, PSDR, ADR, and LSL detection rates. A p value < 0.05 was considered statistically significant. Results: For our patient population, the median age was 58 years; 396 (49.8%) were male and 386 (48.6%) were African American. The 15 GI fellows ranged from first (F1), second (F2), or third (F3) year of training. We found an overall CSSDR of 4.4%, PSDR of 10.5%, ADR of 42.1%, and LSL detection rate of 3.2%. Female gender was associated with CSSDR, while only age was associated with PSDR. GI fellow level of training was associated with LSL detection rate, with the odds of detecting them expected to be four times higher in F2/F3s than F1s. Conclusion: Although GI fellows demonstrated an above-recommended ADR and nearly reached target PSDR, they failed to achieve target CSSDR. Future studies investigating a benchmark for LSL detection rate are needed to quantify if GI fellows are detecting these lesions at adequate rates.

4.
Neuromodulation ; 25(8): 1150-1159, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35183451

RESUMEN

INTRODUCTION: Gastric electrical stimulation (GES) is a widely accepted therapy for gastroparesis symptoms, but how a brief cutaneous electrogastrogram (EGG) can be used in conjunction with GES has not been well defined. We evaluated the clinical importance of EGG, its correlation with mucosal electrograms (mEGs), gastric emptying tests (GETs), and gastrointestinal symptoms before and after temporary GES (tGES). MATERIALS AND METHODS: We studied 1345 patients; 991 had complete data. EGG measurements like frequency and amplitude were recorded at baseline and five days post-tGES using short recording periods. A total of 266 participants having additional cutaneous propagation values were separately analyzed. Patients underwent solid GET before and after tGES and self-reported symptoms using standardized traditional patient-reported outcomes (TradPRO) scores. Pearson correlations were assessed at baseline, post-stimulation, and their changes over the follow-up period. RESULTS: EGG measures correlated with symptoms and GET results. Patients with abnormal baseline cutaneous frequency had higher baseline total symptom scores (p < 0.003). Post-tGES, one-hour gastric emptying was significantly changed (p < 0.0001) and was mainly observed with abnormal baseline cutaneous frequencies (p < 0.0001). Cutaneous frequency significantly increased after tGES (p < 0.0001), correlating positively with TradPRO scores and one-hour gastric emptying. Mucosal and cutaneous measures correlated pre- and post-treatment. Of the 266 patients, 153 changed propagation states between baseline and temporary; changing states from lower at baseline to higher at temporary was more likely than vice versa. Short EGG recording times can demonstrate changes after the bioelectric therapy of GES. CONCLUSION: EGG is valuable in the diagnosis of delayed gastric emptying and comparable with mEG. It is less invasive and can identify patients who may require GES. Frequency, amplitude, their ratio (frequency-amplitude ratio), and propagation appear to be reliable measures of EGG. EGG provides cost-effective measurement of electrophysiological properties and significantly correlates with important clinical measures. Shorter EGG recording times may be adequate to see changes from bioelectric therapies. CLINICAL TRIAL REGISTRATION: The Clinicaltrials.gov registration number for the study is NCT03876288.


Asunto(s)
Terapia por Estimulación Eléctrica , Gastroparesia , Humanos , Gastroparesia/diagnóstico , Gastroparesia/terapia , Terapia por Estimulación Eléctrica/métodos , Piel , Estimulación Eléctrica , Vaciamiento Gástrico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA