Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
ACS Appl Mater Interfaces ; 15(50): 58976-58983, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38062569

RESUMEN

We present a novel iontronic barometric pressure sensor based on a gel polymer electrolyte and interdigital electrodes with a much simpler structure than that of existing devices. By introducing high-density microstructures on the gel polymer electrolyte and one side electrode arrangement configuration, the developed sensor offers high performances with an ultrahigh resolution of 10 Pa, an ultrawide barometric pressure-response range from -92 to 7 kPa, a fast response time of ∼15 ms, and excellent long-term stability. The single pressure sensor is able to detect positive and negative barometric pressures without needing any additional means and can operate as a barometric altimeter with a resolution of about one-floor height. The performances of the sensors significantly surpass those of existing barometric pressure sensors. This work provides a new strategy for making high-performance barometric pressure sensors that are highly sought for commercial applications such as altitude detection, negative pressure ambulance, and consumer electronics.

2.
Environ Sci Pollut Res Int ; 30(49): 108263-108273, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37747605

RESUMEN

In this study, a soft microwave plasma torch (SMPT) combined with a mass spectrometer (MS) was used for the first time as an analytical method to detect and analyze various pharmaceutical and personal care products (PPCPs) in aquatic environments without the need for sample pretreatment. For this purpose, ambient SMPT was used to generate plasma for ionizing the analyte molecules. Accordingly, nine PPCPs were identified by the SMPT-MS, and their identification was verified by collision-induced dissociation (CID). The technique's performance was verified with known PPCP samples, and the limits of detection (LOD) and quantification (LOQ) obtained over a linear range of 50-1 µg/L were 1.56 to 2.81 and 2.07 to 3.62 µg/L, respectively, with the standard addition recovery rate falling between 87.14 and 115.16%. These results show that the method has excellent sensitivity and selectivity, suggesting that SMPT can rapidly and directly detect PPCPs in environmental water, making it a promising method for rapid water quality inspection.


Asunto(s)
Cosméticos , Contaminantes Químicos del Agua , Microondas , Espectrometría de Masas/métodos , Cosméticos/análisis , Preparaciones Farmacéuticas , Contaminantes Químicos del Agua/análisis
3.
Anal Chem ; 2022 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-36562720

RESUMEN

The atmospheric oxidation of chemicals has produced many new unpredicted pollutants. A microwave plasma torch-based ion/molecular reactor (MPTIR) interfacing an online mass spectrometer has been developed for creating and monitoring rapid oxidation reactions. Oxygen in the air is activated by the plasma into highly reactive oxygen radicals, thereby achieving oxidation of thioethers, alcohols, and various environmental pollutants on a millisecond scale without the addition of external oxidants or catalysts (6 orders of magnitude faster than bulk). The direct and real-time oxidation products of polycyclic aromatic hydrocarbons and p-phenylenediamines from the MPTIR match those of the long-term multistep environmental oxidative process. Meanwhile, two unreported environmental compounds were identified with an MPTIR and measured in the actual water samples, which demonstrates the considerable significance of the proposed device for both predicting the environmental pollutants (non-target screening) and studying the mechanism of atmospheric oxidative processes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA