Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39001730

RESUMEN

BACKGROUND: Global longitudinal strain (GLS) is reported to be more reproducible and prognostic than ejection fraction. Automated, transparent methods may increase trust and uptake. OBJECTIVES: The authors developed open machine-learning-based GLS methodology and validate it using multiexpert consensus from the Unity UK Echocardiography AI Collaborative. METHODS: We trained a multi-image neural network (Unity-GLS) to identify annulus, apex, and endocardial curve on 6,819 apical 4-, 2-, and 3-chamber images. The external validation dataset comprised those 3 views from 100 echocardiograms. End-systolic and -diastolic frames were each labelled by 11 experts to form consensus tracings and points. They also ordered the echocardiograms by visual grading of longitudinal function. One expert calculated global strain using 2 proprietary packages. RESULTS: The median GLS, averaged across the 11 individual experts, was -16.1 (IQR: -19.3 to -12.5). Using each case's expert consensus measurement as the reference standard, individual expert measurements had a median absolute error of 2.00 GLS units. In comparison, the errors of the machine methods were: Unity-GLS 1.3, proprietary A 2.5, proprietary B 2.2. The correlations with the expert consensus values were for individual experts 0.85, Unity-GLS 0.91, proprietary A 0.73, proprietary B 0.79. Using the multiexpert visual ranking as the reference, individual expert strain measurements found a median rank correlation of 0.72, Unity-GLS 0.77, proprietary A 0.70, and proprietary B 0.74. CONCLUSIONS: Our open-source approach to calculating GLS agrees with experts' consensus as strongly as the individual expert measurements and proprietary machine solutions. The training data, code, and trained networks are freely available online.

2.
Open Heart ; 11(1)2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38890128

RESUMEN

BACKGROUND: Neurocardiogenic syncope is a common condition with significant associated psychological and physical morbidity. The effectiveness of therapeutic options for neurocardiogenic syncope beyond placebo remains uncertain. METHODS: The primary endpoint was the risk ratio (RR) of spontaneously recurring syncope following any therapeutic intervention. We also examined the effect of blinding on treatment efficacy. We identified all randomised trials which evaluated the effect of any pharmacological, device-based or supportive intervention on patients with a history of syncope. A systematic search was conducted on Medline, Embase, PubMed databases and Cochrane Central Register for Controlled Trials from 1950 to 25 April 2023. Event rates, their RRs and 95% CIs were calculated, and a random-effects meta-analysis was conducted for each intervention. Data analysis was performed in R using RStudio. RESULTS: We identified 47 eligible trials randomising 3518 patients. Blinded trials assessing syncope recurrence were neutral for beta blockers, fludrocortisone and conventional dual-chamber pacing but were favourable for selective serotonin reuptake inhibitors (SSRIs) (RR 0.40, 95% CI 0.26 to 0.63, p<0.001), midodrine (RR 0.70, 95% CI 0.53 to 0.94, p=0.016) and closed-loop stimulation (CLS) pacing (RR 0.15, 95% CI 0.07 to 0.35, p<0.001). Unblinded trials reported significant benefits for all therapy categories other than beta blockers and consistently showed larger benefits than blinded trials. CONCLUSIONS: Under blinded conditions, SSRIs, midodrine and CLS pacing significantly reduced syncope recurrence. Future trials for syncope should be blinded to avoid overestimating treatment effects. PROSPERO REGISTRATION NUMBER: CRD42022330148.


Asunto(s)
Ensayos Clínicos Controlados Aleatorios como Asunto , Síncope Vasovagal , Humanos , Síncope Vasovagal/terapia , Síncope Vasovagal/diagnóstico , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos , Resultado del Tratamiento , Recurrencia
3.
J Am Coll Cardiol ; 84(1): 1-12, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38752902

RESUMEN

BACKGROUND: In stable coronary artery disease, 30% to 60% of patients remain symptomatic despite successful revascularization. Perhaps not all symptoms reported by a patient with myocardial ischemia are, in fact, angina. OBJECTIVES: This study sought to determine whether independent symptom verification using a placebo-controlled ischemic stimulus could distinguish which patients achieve greatest symptom relief from percutaneous coronary intervention (PCI). METHODS: ORBITA-STAR was a multicenter, n-of-1, placebo-controlled study in patients undergoing single-vessel PCI for stable symptoms. Participants underwent 4 episodes (60 seconds each) of low-pressure balloon occlusion across their coronary stenosis, randomly paired with 4 episodes of placebo inflation. Following each episode, patients reported the similarity of the induced symptom in comparison with their usual symptom. The similarity score ranged from -10 (placebo replicated the symptom more than balloon occlusion) to +10 (balloon occlusion exactly replicated the symptom). The primary endpoint was the ability of the similarity score to predict symptom relief with PCI. RESULTS: Fifty-one patients were recruited, aged 62.9 ± 8.6 years. The median fractional flow reserve was 0.68 (Q1-Q3: 0.57-0.79), and the instantaneous wave-free ratio was 0.80 (Q1-Q3: 0.48-0.89). The median similarity score was 3 (Q1-Q3: 0.875-5.25). The similarity score was a strong predictor of symptom improvement following PCI: a patient with an upper quartile similarity score of 5.25 was significantly more likely to have lower angina frequency at follow-up (OR: 8.01; 95% credible interval: 2.39-15.86) than a patient with a lower quartile similarity score of 0.875 (OR: 1.31; 95% credible interval: 0.71-1.99), Pr(difference) >99.9%. CONCLUSIONS: Similarity score powerfully predicted symptom improvement from PCI. These data lay the foundation for independent symptom mapping to target PCI to those patients most likely to benefit. (Systematic Trial of Angina Assessment Before Revascularization [ORBITA-STAR]; NCT04280575).


Asunto(s)
Angina de Pecho , Intervención Coronaria Percutánea , Humanos , Masculino , Persona de Mediana Edad , Femenino , Intervención Coronaria Percutánea/métodos , Angina de Pecho/terapia , Anciano , Resultado del Tratamiento
4.
J Am Coll Cardiol ; 84(1): 13-24, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38759906

RESUMEN

BACKGROUND: Placebo-controlled evidence from ORBITA-2 (Objective Randomised Blinded Investigation with Optimal Medical Therapy of Angioplasty in Stable Angina-2) found that percutaneous coronary intervention (PCI) in stable coronary artery disease with little or no antianginal medication relieved angina, but residual symptoms persisted in many patients. The reason for this was unclear. OBJECTIVES: This ORBITA-2 secondary analysis investigates the relationship between presenting symptoms and disease severity (anatomic, noninvasive, and invasive ischemia) and the ability of symptoms to predict the placebo-controlled efficacy of PCI. METHODS: Prerandomization symptom severity and nature were assessed using the ORBITA smartphone application and symptom and quality of life questionnaires including the World Health Organization Rose angina questionnaire (Rose). Disease severity was assessed using quantitative coronary angiography, stress echocardiography, fractional flow reserve, and instantaneous wave-free ratio. Bayesian ordinal regression was used. RESULTS: At prerandomization, the median number of daily angina episodes was 0.8 (Q1-Q3: 0.4-1.6), 64% had Rose angina, quantitative coronary angiography diameter stenosis was 61% (Q1-Q3: 49%-74%), stress echocardiography score was 1.0 (Q1-Q3: 0.0-2.7), fractional flow reserve was 0.63 (Q1-Q3: 0.49-0.75), and instantaneous wave-free ratio was 0.78 (Q1-Q3: 0.55-0.87). There was little relationship between symptom severity and nature and disease severity: angina symptom score with quantitative coronary angiography ordinal correlation coefficient: 0.06 (95% credible interval [CrI]: 0.00-0.08); stress echocardiography: 0.09 (95% CrI: 0.02-0.10); fractional flow reserve: 0.04 (95% CrI: -0.03 to 0.07); and instantaneous wave-free ratio: 0.04 (95% CrI: -0.01 to 0.07). However, Rose angina and guideline-based typical angina were strong predictors of placebo-controlled PCI efficacy (angina symptom score: OR: 1.9; 95% CrI: 1.6-2.1; probability of interaction [PrInteraction] = 99.9%; and OR: 1.8; 95% CrI: 1.6-2.1; PrInteraction = 99.9%, respectively). CONCLUSIONS: Although symptom severity and nature were poorly associated with disease severity, the nature of symptoms powerfully predicted the placebo-controlled efficacy of PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Intervención Coronaria Percutánea/métodos , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico , Anciano , Resultado del Tratamiento , Angiografía Coronaria , Índice de Severidad de la Enfermedad , Angina Estable/terapia , Angina Estable/diagnóstico , Angina Estable/fisiopatología , Calidad de Vida
5.
Lancet ; 403(10436): 1543-1553, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38604209

RESUMEN

BACKGROUND: The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS: ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS: Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR group (n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION: ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING: Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.


Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Seno Coronario , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/terapia , Angina Estable/tratamiento farmacológico , Seno Coronario/diagnóstico por imagen , Teorema de Bayes , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Método Doble Ciego , Isquemia , Adenosina
6.
Artículo en Inglés | MEDLINE | ID: mdl-38649588

RESUMEN

BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.

7.
Comput Methods Programs Biomed ; 248: 108111, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38479147

RESUMEN

BACKGROUND AND OBJECTIVE: Training deep learning models for medical image segmentation require large annotated datasets, which can be expensive and time-consuming to create. Active learning is a promising approach to reduce this burden by strategically selecting the most informative samples for segmentation. This study investigates the use of active learning for efficient left ventricle segmentation in echocardiography with sparse expert annotations. METHODS: We adapt and evaluate various sampling techniques, demonstrating their effectiveness in judiciously selecting samples for segmentation. Additionally, we introduce a novel strategy, Optimised Representativeness Sampling, which combines feature-based outliers with the most representative samples to enhance annotation efficiency. RESULTS: Our findings demonstrate a substantial reduction in annotation costs, achieving a remarkable 99% upper bound performance while utilising only 20% of the labelled data. This equates to a reduction of 1680 images needing annotation within our dataset. When applied to a publicly available dataset, our approach yielded a remarkable 70% reduction in required annotation efforts, representing a significant advancement compared to baseline active learning strategies, which achieved only a 50% reduction. Our experiments highlight the nuanced performance of diverse sampling strategies across datasets within the same domain. CONCLUSIONS: The study provides a cost-effective approach to tackle the challenges of limited expert annotations in echocardiography. By introducing a distinct dataset, made publicly available for research purposes, our work contributes to the field's understanding of efficient annotation strategies in medical image segmentation.


Asunto(s)
Ecocardiografía , Ventrículos Cardíacos , Ventrículos Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador
8.
J Vet Intern Med ; 38(2): 922-930, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38362960

RESUMEN

BACKGROUND: Artificial intelligence (AI) could improve accuracy and reproducibility of echocardiographic measurements in dogs. HYPOTHESIS: A neural network can be trained to measure echocardiographic left ventricular (LV) linear dimensions in dogs. ANIMALS: Training dataset: 1398 frames from 461 canine echocardiograms from a single specialist center. VALIDATION: 50 additional echocardiograms from the same center. METHODS: Training dataset: a right parasternal 4-chamber long axis frame from each study, labeled by 1 of 18 echocardiographers, marking anterior and posterior points of the septum and free wall. VALIDATION DATASET: End-diastolic and end-systolic frames from 50 studies, annotated twice (blindly) by 13 experts, producing 26 measurements of each site from each frame. The neural network also made these measurements. We quantified its accuracy as the deviation from the expert consensus, using the individual-expert deviation from consensus as context for acceptable variation. The deviation of the AI measurement away from the expert consensus was assessed on each individual frame and compared with the root-mean-square-variation of the individual expert opinions away from that consensus. RESULTS: For the septum in end-diastole, individual expert opinions deviated by 0.12 cm from the consensus, while the AI deviated by 0.11 cm (P = .61). For LVD, the corresponding values were 0.20 cm for experts and 0.13 cm for AI (P = .65); for the free wall, experts 0.20 cm, AI 0.13 cm (P < .01). In end-systole, there were no differences between individual expert and AI performances. CONCLUSIONS AND CLINICAL IMPORTANCE: An artificial intelligence network can be trained to adequately measure linear LV dimensions, with performance indistinguishable from that of experts.


Asunto(s)
Inteligencia Artificial , Ecocardiografía , Perros , Animales , Reproducibilidad de los Resultados , Ecocardiografía/veterinaria , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Diástole
9.
Comput Biol Med ; 171: 108192, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38417384

RESUMEN

Doppler echocardiography is a widely utilised non-invasive imaging modality for assessing the functionality of heart valves, including the mitral valve. Manual assessments of Doppler traces by clinicians introduce variability, prompting the need for automated solutions. This study introduces an innovative deep learning model for automated detection of peak velocity measurements from mitral inflow Doppler images, independent from Electrocardiogram information. A dataset of Doppler images annotated by multiple expert cardiologists was established, serving as a robust benchmark. The model leverages heatmap regression networks, achieving 96% detection accuracy. The model discrepancy with the expert consensus falls comfortably within the range of inter- and intra-observer variability in measuring Doppler peak velocities. The dataset and models are open-source, fostering further research and clinical application.


Asunto(s)
Aprendizaje Profundo , Velocidad del Flujo Sanguíneo , Ecocardiografía Doppler/métodos , Válvula Mitral/diagnóstico por imagen , Ultrasonografía Doppler
10.
Cardiovasc Revasc Med ; 59: 60-66, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37612169

RESUMEN

BACKGROUND: Landmark trials showed that invasive pressure measurement (Fractional Flow Reserve, FFR) was a better guide to coronary stenting than visual assessment. However, present-day interventionists have benefited from extensive research and personal experience of mapping anatomy to hemodynamics. AIMS: To determine if visual assessment of the angiogram performs as well as invasive measurement of coronary physiology. METHODS: 25 interventional cardiologists independently visually assessed the single vessel coronary disease of 200 randomized participants in The Objective Randomized Blinded Investigation with optimal medical Therapy of Angioplasty in stable angina trial (ORBITA). They gave a visual prediction of the FFR and Instantaneous Wave-free Ratio (iFR), denoted vFFR and viFR respectively. Each judged each lesion on 2 occasions, so that every lesion had 50 vFFR, and 50 viFR assessments. The group consensus visual estimates (vFFR-group and viFR-group) and individual cardiologists' visual estimates (vFFR-individual and viFR-individual) were tested alongside invasively measured FFR and iFR for their ability to predict the placebo-controlled reduction in stress echo ischemia with stenting. RESULTS: Placebo-controlled ischemia improvement with stenting was predicted by vFFR-group (p < 0.0001) and viFR-group (p < 0.0001), vFFR-individual (p < 0.0001) and viFR-individual (p < 0.0001). There were no significant differences between the predictive performance of the group visual estimates and their invasive counterparts: p = 0.53 for vFFR vs FFR and p = 0.56 for viFR vs iFR. CONCLUSION: Visual assessment of the angiogram by contemporary experts, provides significant additional information on the amount of ischaemia which can be relieved by placebo-controlled stenting in single vessel coronary artery disease.


Asunto(s)
Cardiólogos , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Isquemia , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
11.
Artículo en Inglés | MEDLINE | ID: mdl-38124803

RESUMEN

Background: The prognostic impact of ventricular tachycardia (VT) catheter ablation is an important outstanding research question. We undertook a reconstructed individual patient data meta-analysis of randomised controlled trials comparing ablation to medical therapy in patients developing VT after MI. Methods: We systematically identified all trials comparing catheter ablation to medical therapy in patients with VT and prior MI. The prespecified primary endpoint was reconstructed individual patient assessment of all-cause mortality. Prespecified secondary endpoints included trial-level assessment of all-cause mortality, VT recurrence or defibrillator shocks and all-cause hospitalisations. Prespecified subgroup analysis was performed for ablation approaches involving only substrate modification without VT activation mapping. Sensitivity analyses were performed depending on the proportion of patients with prior MI included. Results: Eight trials, recruiting a total of 874 patients, were included. Of these 874 patients, 430 were randomised to catheter ablation and 444 were randomised to medical therapy. Catheter ablation reduced all-cause mortality compared with medical therapy when synthesising individual patient data (HR 0.63; 95% CI [0.41-0.96]; p=0.03), but not in trial-level analysis (RR 0.91; 95% CI [0.67-1.23]; p=0.53; I2=0%). Catheter ablation significantly reduced VT recurrence, defibrillator shocks and hospitalisations compared with medical therapy. Sensitivity analyses were consistent with the primary analyses. Conclusion: In patients with postinfarct VT, catheter ablation reduces mortality.

12.
N Engl J Med ; 389(25): 2319-2330, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38015442

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) is frequently performed to reduce the symptoms of stable angina. Whether PCI relieves angina more than a placebo procedure in patients who are not receiving antianginal medication remains unknown. METHODS: We conducted a double-blind, randomized, placebo-controlled trial of PCI in patients with stable angina. Patients stopped all antianginal medications and underwent a 2-week symptom assessment phase before randomization. Patients were then randomly assigned in a 1:1 ratio to undergo PCI or a placebo procedure and were followed for 12 weeks. The primary end point was the angina symptom score, which was calculated daily on the basis of the number of angina episodes that occurred on a given day, the number of antianginal medications prescribed on that day, and clinical events, including the occurrence of unblinding owing to unacceptable angina or acute coronary syndrome or death. Scores range from 0 to 79, with higher scores indicating worse health status with respect to angina. RESULTS: A total of 301 patients underwent randomization: 151 to the PCI group and 150 to the placebo group. The mean (±SD) age was 64±9 years, and 79% were men. Ischemia was present in one cardiac territory in 242 patients (80%), in two territories in 52 patients (17%), and in three territories in 7 patients (2%). In the target vessels, the median fractional flow reserve was 0.63 (interquartile range, 0.49 to 0.75), and the median instantaneous wave-free ratio was 0.78 (interquartile range, 0.55 to 0.87). At the 12-week follow-up, the mean angina symptom score was 2.9 in the PCI group and 5.6 in the placebo group (odds ratio, 2.21; 95% confidence interval, 1.41 to 3.47; P<0.001). One patient in the placebo group had unacceptable angina leading to unblinding. Acute coronary syndromes occurred in 4 patients in the PCI group and in 6 patients in the placebo group. CONCLUSIONS: Among patients with stable angina who were receiving little or no antianginal medication and had objective evidence of ischemia, PCI resulted in a lower angina symptom score than a placebo procedure, indicating a better health status with respect to angina. (Funded by the National Institute for Health and Care Research Imperial Biomedical Research Centre and others; ORBITA-2 ClinicalTrials.gov number, NCT03742050.).


Asunto(s)
Angina Estable , Intervención Coronaria Percutánea , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Síndrome Coronario Agudo , Angina Estable/tratamiento farmacológico , Angina Estable/cirugía , Fármacos Cardiovasculares/uso terapéutico , Reserva del Flujo Fraccional Miocárdico , Estado de Salud , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Método Doble Ciego , Isquemia Miocárdica
13.
Europace ; 25(10)2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37815462

RESUMEN

AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Masculino , Humanos , Anciano , Femenino , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco , Hemodinámica , Ventrículos Cardíacos , Electrocardiografía/métodos
14.
Eur Heart J Digit Health ; 4(4): 291-301, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37538145

RESUMEN

Aims: Coronary flow reserve (CFR) assessment has proven clinical utility, but Doppler-based methods are sensitive to noise and operator bias, limiting their clinical applicability. The objective of the study is to expand the adoption of invasive Doppler CFR, through the development of artificial intelligence (AI) algorithms to automatically quantify coronary Doppler quality and track flow velocity. Methods and results: A neural network was trained on images extracted from coronary Doppler flow recordings to score signal quality and derive values for coronary flow velocity and CFR. The outputs were independently validated against expert consensus. Artificial intelligence successfully quantified Doppler signal quality, with high agreement with expert consensus (Spearman's rho: 0.94), and within individual experts. Artificial intelligence automatically tracked flow velocity with superior numerical agreement against experts, when compared with the current console algorithm [AI flow vs. expert flow bias -1.68 cm/s, 95% confidence interval (CI) -2.13 to -1.23 cm/s, P < 0.001 with limits of agreement (LOA) -4.03 to 0.68 cm/s; console flow vs. expert flow bias -2.63 cm/s, 95% CI -3.74 to -1.52, P < 0.001, 95% LOA -8.45 to -3.19 cm/s]. Artificial intelligence yielded more precise CFR values [median absolute difference (MAD) against expert CFR: 4.0% for AI and 7.4% for console]. Artificial intelligence tracked lower-quality Doppler signals with lower variability (MAD against expert CFR 8.3% for AI and 16.7% for console). Conclusion: An AI-based system, trained by experts and independently validated, could assign a quality score to Doppler traces and derive coronary flow velocity and CFR. By making Doppler CFR more automated, precise, and operator-independent, AI could expand the clinical applicability of coronary microvascular assessment.

15.
J Am Heart Assoc ; 12(8): e028661, 2023 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-37042261

RESUMEN

Background Idiopathic ventricular fibrillation (VF) is a diagnosis of exclusion following normal cardiac investigations. We sought to determine if exercise-induced changes in electrical substrate could distinguish patient groups with various ventricular arrhythmic pathophysiological conditions and identify patients susceptible to VF. Methods and Results Computed tomography and exercise testing in patients wearing a 252-electrode vest were combined to determine ventricular conduction stability between rest and peak exercise, as previously described. Using ventricular conduction stability, conduction heterogeneity in idiopathic VF survivors (n=14) was compared with those surviving VF during acute ischemia with preserved ventricular function following full revascularization (n=10), patients with benign ventricular ectopy (n=11), and patients with normal hearts, no arrhythmic history, and negative Ajmaline challenge during Brugada family screening (Brugada syndrome relatives; n=11). Activation patterns in normal subjects (Brugada syndrome relatives) are preserved following exercise, with mean ventricular conduction stability of 99.2±0.9%. Increased heterogeneity of activation occurred in the idiopathic VF survivors (ventricular conduction stability: 96.9±2.3%) compared with the other groups combined (versus 98.8±1.6%; P=0.001). All groups demonstrated periodic variation in activation heterogeneity (frequency, 0.3-1 Hz), but magnitude was greater in idiopathic VF survivors than Brugada syndrome relatives or patients with ventricular ectopy (7.6±4.1%, 2.9±2.9%, and 2.8±1.2%, respectively). The cause of this periodicity is unknown and was not replicable by introducing exercise-induced noise at comparable frequencies. Conclusions In normal subjects, ventricular activation patterns change little with exercise. In contrast, patients with susceptibility to VF experience activation heterogeneity following exercise that requires further investigation as a testable manifestation of underlying myocardial abnormalities otherwise silent during routine testing.


Asunto(s)
Síndrome de Brugada , Complejos Prematuros Ventriculares , Humanos , Síndrome de Brugada/complicaciones , Síndrome de Brugada/diagnóstico , Sistema de Conducción Cardíaco , Complejos Prematuros Ventriculares/etiología , Complejos Prematuros Ventriculares/complicaciones , Electrocardiografía , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Sobrevivientes
16.
Europace ; 25(3): 1060-1067, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36734205

RESUMEN

AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Electrocardiografía/métodos , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hemodinámica , Estimulación Cardíaca Artificial/métodos
17.
J Cardiovasc Electrophysiol ; 34(6): 1431-1440, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36786511

RESUMEN

INTRODUCTION: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration. METHODS: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms. RESULTS: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg). CONCLUSION: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Terapia de Resincronización Cardíaca/efectos adversos , Hemodinámica/fisiología , Bloqueo de Rama , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Función Ventricular Izquierda/fisiología , Estimulación Cardíaca Artificial
18.
Med Biol Eng Comput ; 61(5): 911-926, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36631666

RESUMEN

Tissue Doppler imaging is an essential echocardiographic technique for the non-invasive assessment of myocardial blood velocity. Image acquisition and interpretation are performed by trained operators who visually localise landmarks representing Doppler peak velocities. Current clinical guidelines recommend averaging measurements over several heartbeats. However, this manual process is both time-consuming and disruptive to workflow. An automated system for accurate beat isolation and landmark identification would be highly desirable. A dataset of tissue Doppler images was annotated by three cardiologist experts, providing a gold standard and allowing for observer variability comparisons. Deep neural networks were trained for fully automated predictions on multiple heartbeats and tested on tissue Doppler strips of arbitrary length. Automated measurements of peak Doppler velocities show good Bland-Altman agreement (average standard deviation of 0.40 cm/s) with consensus expert values; less than the inter-observer variability (0.65 cm/s). Performance is akin to individual experts (standard deviation of 0.40 to 0.75 cm/s). Our approach allows for > 26 times as many heartbeats to be analysed, compared to a manual approach. The proposed automated models can accurately and reliably make measurements on tissue Doppler images spanning several heartbeats, with performance indistinguishable from that of human experts, but with significantly shorter processing time. HIGHLIGHTS: • Novel approach successfully identifies heartbeats from Tissue Doppler Images • Accurately measures peak velocities on several heartbeats • Framework is fast and can make predictions on arbitrary length images • Patient dataset and models made public for future benchmark studies.


Asunto(s)
Algoritmos , Ecocardiografía Doppler , Humanos , Ecocardiografía Doppler/métodos , Redes Neurales de la Computación , Ecocardiografía , Miocardio
20.
Eur J Heart Fail ; 25(2): 274-283, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36404397

RESUMEN

AIMS: Excessive prolongation of PR interval impairs coupling of atrio-ventricular (AV) contraction, which reduces left ventricular pre-load and stroke volume, and worsens symptoms. His bundle pacing allows AV delay shortening while maintaining normal ventricular activation. HOPE-HF evaluated whether AV optimized His pacing is preferable to no-pacing, in a double-blind cross-over fashion, in patients with heart failure, left ventricular ejection fraction (LVEF) ≤40%, PR interval ≥200 ms and either QRS ≤140 ms or right bundle branch block. METHODS AND RESULTS: Patients had atrial and His bundle leads implanted (and an implantable cardioverter-defibrillator lead if clinically indicated) and were randomized to 6 months of pacing and 6 months of no-pacing utilizing a cross-over design. The primary outcome was peak oxygen uptake during symptom-limited exercise. Quality of life, LVEF and patients' holistic symptomatic preference between arms were secondary outcomes. Overall, 167 patients were randomized: 90% men, 69 ± 10 years, QRS duration 124 ± 26 ms, PR interval 249 ± 59 ms, LVEF 33 ± 9%. Neither peak oxygen uptake (+0.25 ml/kg/min, 95% confidence interval [CI] -0.23 to +0.73, p = 0.3) nor LVEF (+0.5%, 95% CI -0.7 to 1.6, p = 0.4) changed with pacing but Minnesota Living with Heart Failure quality of life improved significantly (-3.7, 95% CI -7.1 to -0.3, p = 0.03). Seventy-six percent of patients preferred His bundle pacing-on and 24% pacing-off (p < 0.0001). CONCLUSION: His bundle pacing did not increase peak oxygen uptake but, under double-blind conditions, significantly improved quality of life and was symptomatically preferred by the clear majority of patients. Ventricular pacing delivered via the His bundle did not adversely impact ventricular function during the 6 months.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Masculino , Humanos , Femenino , Fascículo Atrioventricular , Estudios Cruzados , Volumen Sistólico , Calidad de Vida , Tolerancia al Ejercicio , Función Ventricular Izquierda , Oxígeno , Resultado del Tratamiento , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...