Resultados 1 - 20 de 20
Filtrar
1.
J Cardiovasc Magn Reson ; 26(2): 101068, 2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39079602

RESUMEN

BACKGROUND: Diagnosing myocarditis relies on multimodal data, including cardiovascular magnetic resonance (CMR), clinical symptoms, and blood values. The correct interpretation and integration of CMR findings require radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis. METHODS: This retrospective study includes CMR reports from 396 patients with suspected myocarditis and eight centers, respectively. CMR reports and patient data including blood values, age, and further clinical information were provided to GPT-4 and radiologists with 1 (resident 1), 2 (resident 2), and 4 years (resident 3) of experience in CMR and knowledge of the 2018 Lake Louise Criteria. The final impression of the report regarding the radiological assessment of whether myocarditis is present or not was not provided. The performance of Generative pre-trained transformer 4 (GPT-4) and the human readers were compared to a consensus reading (two board-certified radiologists with 8 and 10 years of experience in CMR). Sensitivity, specificity, and accuracy were calculated. RESULTS: GPT-4 yielded an accuracy of 83%, sensitivity of 90%, and specificity of 78%, which was comparable to the physician with 1 year of experience (R1: 86%, 90%, 84%, p = 0.14) and lower than that of more experienced physicians (R2: 89%, 86%, 91%, p = 0.007 and R3: 91%, 85%, 96%, p < 0.001). GPT-4 and human readers showed a higher diagnostic performance when results from T1- and T2-mapping sequences were part of the reports, for residents 1 and 3 with statistical significance (p = 0.004 and p = 0.02, respectively). CONCLUSION: GPT-4 yielded good accuracy for diagnosing myocarditis based on CMR reports in a large dataset from multiple centers and therefore holds the potential to serve as a diagnostic decision-supporting tool in this capacity, particularly for less experienced physicians. Further studies are required to explore the full potential and elucidate educational aspects of the integration of large language models in medical decision-making.

2.
Int J Nanomedicine ; 19: 2137-2148, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38476277

RESUMEN

Purpose: Magnetic particle imaging (MPI) is an emerging medical imaging modality that is on the verge of clinical use. In recent years, cardiovascular applications have shown huge potential like, e.g., intraprocedural imaging guidance of stent placement through MPI. Due to the lack of signal generation, nano-modifications have been necessary to visualize commercial medical instruments until now. In this work, it is investigated if commercial interventional devices can be tracked with MPI without any nano-modification. Material and Methods: Potential MPI signal generation of nine endovascular metal stents was tested in a commercial MPI scanner. Two of the stents revealed sufficient MPI signal. Because one of the two stents showed relevant heating, the imaging experiments were carried out with a single stent model (Boston Scientific/Wallstent-Uni Endoprothesis, diameter: 16 mm, length: 60 mm). The nitinol stent and its delivery system were investigated in seven different scenarios. Therefore, the samples were placed at 49 defined spatial positions by a robot in a meandering pattern during MPI scans. Image reconstruction was performed, and the mean absolute errors (MAE) between the signals' centers of mass (COM) and ground truth positions were calculated. The stent material was investigated by magnetic particle spectroscopy (MPS) and vibrating sample magnetometry (VSM). To detect metallic components within the delivery system, nondestructive testing via computed tomography was performed. Results: The tracking of the stent and its delivery system was possible without any nano-modification. The MAE of the COM were 1.49 mm for the stent mounted on the delivery system, 3.70 mm for the expanded stent and 1.46 mm for the delivery system without the stent. The results of the MPS and VSM measurements indicate that besides material properties eddy currents seem to be responsible for signal generation. Conclusion: It is possible to image medical instruments with dedicated designs without modifications by means of MPI. This enables a variety of applications without compromising the mechanical and biocompatible properties of the instruments.


Asunto(s)
Stents , Tomografía Computarizada por Rayos X , Procesamiento de Imagen Asistido por Computador/métodos , Magnetismo , Fenómenos Magnéticos
3.
Eur Radiol ; 34(9): 5666-5677, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38418626

RESUMEN

RATIONALE: To provide an overview of the current status of cardiac multimodality imaging practices in Europe and radiologist involvement using data from the European Society of Cardiovascular Radiology (ESCR) MRCT-registry. MATERIALS AND METHODS: Numbers on cardiac CT and MRI examinations were extracted from the MRCT-registry of the ESCR, entered between January 2011 and October 2023 (n = 432,265). Data collection included the total/annual numbers of examinations, indications, complications, and reporting habits. RESULTS: Thirty-two countries contributed to the MRCT-registry, including 29 European countries. Between 2011 and 2022, there was a 4.5-fold increase in annually submitted CT examinations, from 3368 to 15,267, and a 3.8-fold increase in MRI examinations, from 3445 to 13,183. The main indications for cardiac CT were suspected coronary artery disease (CAD) (59%) and transcatheter aortic valve replacement planning (21%). The number of patients with intermediate pretest probability who underwent CT for suspected CAD showed an increase from 61% in 2012 to 82% in 2022. The main MRI indications were suspected myocarditis (26%), CAD (21%), and suspected cardiomyopathy (19%). Adverse event rates were very low for CT (0.3%) and MRI (0.7%) examinations. Reporting of CT and MRI examinations was performed mainly by radiologists (respectively 76% and 71%) and, to a lesser degree, in consensus with non-radiologists (19% and 27%, respectively). The remaining examinations (4.9% CT and 1.7% MRI) were reported by non-radiological specialties or in separate readings of radiologists and non-radiologists. CONCLUSIONS: Real-life data on cardiac imaging in Europe using the largest available MRCT-registry demonstrate a considerable increase in examinations over the past years, the vast majority of which are read by radiologists. These findings indicate that radiologists contribute to meeting the increasing demands of competent and effective care in cardiac imaging to a relevant extent. CLINICAL RELEVANCE STATEMENT: The number of cardiac CT and MRI examinations has risen over the past years, and radiologists read the vast majority of these studies as recorded in the MRCT-registry. KEY POINTS: • The number of cardiac imaging examinations is constantly increasing. • Radiologists play a central role in providing cardiac CT and MR imaging services to a large volume of patients. • Cardiac CT and MR imaging examinations performed and read by radiologists show a good safety profile.


Asunto(s)
Competencia Clínica , Imagen por Resonancia Magnética , Radiólogos , Sistema de Registros , Tomografía Computarizada por Rayos X , Humanos , Europa (Continente) , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Radiólogos/estadística & datos numéricos , Cardiopatías/diagnóstico por imagen , Masculino
4.
Artículo en Inglés | MEDLINE | ID: mdl-38345706

RESUMEN

BACKGROUND: Persistent left superior vena cava (PLSVC) is a rare venous anomaly, affecting 0.3-0.5% of the general population. Cardiac resynchronization therapy (CRT) implantation in patients with PLSVC is challenging due to a complex anatomy. Moreover, data on CRT implantation in this patient population is scarce. Our aim was to report a series of patients with PLSVC and CRT implantation focusing on challenges and pitfalls. METHODS: Electronic medical databases on patients with CRT implantation at the University Heart Centers in Zurich, Switzerland, and Lübeck, Germany, were screened for individuals with a PLSVC. Clinical and demographic characteristics as well as procedural data were reported in all patients. RESULTS: This study presents six cases with a median age of 66 years. CRT implantation was successful in five patients, leading to a reduced QRS duration and improved left ventricular ejection fraction. Atrial fibrillation, ischemic cardiomyopathy, valvular heart disease, and dilated cardiomyopathy were observed in this group as underlying conditions. Specialized tools, such as active fixation left ventricular leads, were utilized. One patient experienced major complications. CONCLUSIONS: This case series shows that although challenging, conventional endovascular CRT implantation is feasible in PLSVC patients. Specialized tools for visualization and fixation may help. Our experiences highlight the importance of preprocedural evaluation of the anatomy and precise intervention planning.

5.
Cancers (Basel) ; 15(15)2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37568823

RESUMEN

Multiple myeloma (MM) frequently induces persisting osteolytic manifestations despite hematologic treatment response. This study aimed to establish a biometrically valid study endpoint for bone remineralization through quantitative and qualitative analyses in sequential CT scans. Twenty patients (seven women, 58 ± 8 years) with newly diagnosed MM received standardized induction therapy comprising the anti-SLAMF7 antibody elotuzumab, carfilzomib, lenalidomide, and dexamethasone (E-KRd). All patients underwent whole-body low-dose CT scans before and after six cycles of E-KRd. Two radiologists independently recorded osteolytic lesion sizes, as well as the presence of cortical destruction, pathologic fractures, rim and trabecular sclerosis. Bland-Altman analyses and Krippendorff's α were employed to assess inter-reader reliability, which was high for lesion size measurement (standard error 1.2 mm) and all qualitative criteria assessed (α ≥ 0.74). After six cycles of E-KRd induction, osteolytic lesion size decreased by 22% (p < 0.001). While lesion size response did not correlate with the initial lesion size at baseline imaging (Pearson's r = 0.144), logistic regression analysis revealed that the majority of responding osteolyses exhibited trabecular sclerosis (p < 0.001). The sum of osteolytic lesion sizes on sequential CT scans defines a reliable study endpoint to characterize bone remineralization. Patient level response is strongly associated with the presence of trabecular sclerosis.

6.
Eur Radiol ; 33(8): 5664-5674, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36897346

RESUMEN

OBJECTIVES: To evaluate work expectations of radiologists at different career levels, their fulfillment, prevalence of exhaustion, and exhaustion-associated factors. METHODS: A standardized digital questionnaire was distributed internationally to radiologists of all career levels in the hospital and in ambulatory care via radiological societies and sent manually to 4500 radiologists of the largest German hospitals between December 2020 and April 2021. Statistics were based on age- and gender-adjusted regression analyses of respondents working in Germany (510 out of 594 total respondents). RESULTS: The most frequent expectations were "joy at work" (97%) and a "good working atmosphere" (97%), which were considered fulfilled by at least 78%. The expectation of a "structured residency within the regular time interval" (79%) was more frequently judged fulfilled by senior physicians (83%, odds ratio (OR) 4.31 [95% confidence interval (95% CI) 1.95-9.52]), chief physicians (85%, 6.81 [95% CI 1.91-24.29]), and radiologists outside the hospital (88%, 7.59 [95% CI 2.40-24.03]) than by residents (68%). Exhaustion was most common among residents (physical exhaustion: 38%; emotional exhaustion: 36%), in-hospital specialists (29%; 38%), and senior physicians (30%; 29%). In contrast to paid extra hours, unpaid extra hours were associated with physical exhaustion (5-10 extra hours: OR 2.54 [95% CI 1.54-4.19]). Fewer opportunities to shape the work environment were related to a higher probability of physical (2.03 [95% CI 1.32-3.13]) and emotional (2.15 [95% CI 1.39-3.33]) exhaustion. CONCLUSIONS: While most radiologists enjoy their work, residents wish for more training structure. Ensuring payment of extra hours and employee empowerment may help preventing burnout in high-risk groups. KEY POINTS: • Most important work expectations of radiologists who work in Germany are "joy at work," a "good working atmosphere," "support for further qualification," and a "structured residency within the regular time interval," with the latter containing potential for improvement according to residents. • Physical and emotional exhaustion are common at all career levels except for chief physicians and for radiologists who work outside the hospital in ambulatory care. • Exhaustion as a major burnout criterion is associated with unpaid extra hours and reduced opportunities to shape the work environment.


Asunto(s)
Agotamiento Profesional , Internado y Residencia , Médicos , Humanos , Motivación , Radiólogos/psicología , Médicos/psicología , Agotamiento Profesional/epidemiología , Agotamiento Profesional/psicología , Encuestas y Cuestionarios
7.
Sensors (Basel) ; 23(4)2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36850766

RESUMEN

Medical ultrasound (US) is a commonly used modality for image-guided procedures. Recent research systems providing an in situ visualization of 2D US images via an augmented reality (AR) head-mounted display (HMD) were shown to be advantageous over conventional imaging through reduced task completion times and improved accuracy. In this work, we continue in the direction of recent developments by describing the first AR HMD application visualizing real-time volumetric (3D) US in situ for guiding vascular punctures. We evaluated the application on a technical level as well as in a mixed-methods user study with a qualitative prestudy and a quantitative main study, simulating a vascular puncture. Participants completed the puncture task significantly faster when using 3D US AR mode compared to 2D US AR, with a decrease of 28.4% in time. However, no significant differences were observed regarding the success rate of vascular puncture (2D US AR-50% vs. 3D US AR-72%). On the technical side, the system offers a low latency of 49.90 ± 12.92 ms and a satisfactory frame rate of 60 Hz. Our work shows the feasibility of a system that visualizes real-time 3D US data via an AR HMD, and our experiments show, furthermore, that this may offer additional benefits in US-guided tasks (i.e., reduced task completion time) over 2D US images viewed in AR by offering a vividly volumetric visualization.


Asunto(s)
Realidad Aumentada , Gafas Inteligentes , Humanos , Punciones , Ultrasonografía
8.
Cardiovasc Intervent Radiol ; 45(11): 1684-1692, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36002537

RESUMEN

OBJECTIVE: Thrombectomy of the aortoiliac segment remains a challenge for surgical and endovascular revision. This study aimed to evaluate the concept of percutaneous thrombectomy in patients with aortoiliac segment occlusions. MATERIALS & METHODS: Eighteen patients with aortoiliac occlusion who underwent percutaneous thrombectomy were retrospectively identified using the local picture archive and divided into the stent-graft (N = 10) and native vessels (N = 8) groups. The procedure was performed by placing a 12-24 French sheath adjacent to the distal end of the occluded vessel segment. The occlusion was passed with a balloon catheter which was retracted after inflation, to deliver the thrombus into the sheath. Technical success (reperfusion of the vessel and no residual thrombus/stenosis < 30%), complications and primary arterial patency were assessed. Follow-up included computed tomography angiography and evaluation of the clinical situation via telephone. RESULTS: Technical success was achieved in 38% (7/18) of patients after percutaneous thrombectomy alone and in 100% after additional procedures. The most common complication was peripheral embolism (44%, 8/18), which was treated successfully in all cases and was linked to a mismatch between the sheath and target vessel of ≥ 1 mm (P < .01). There were no significant differences in the incidence of complications between the two groups. Primary patency was 72% (13/18) with no significant difference between groups (P = .94). Follow-up CT scans were available for 13/18 patients (72%), with a mean follow-up time of 270 ± 146 days. All patients were contacted via phone (follow-up time, 653 ± 264 days). CONCLUSION: Percutaneous thrombectomy appears to be effective for revascularization of the aortoiliac segment, both in stent-grafts and in native vessels. The most common complication is peripheral embolism; however, the risk may be reduced by choosing an adequate sheath size.


Asunto(s)
Embolia , Trombosis , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Trombectomía/métodos , Stents
9.
Discov Oncol ; 13(1): 22, 2022 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-35384584

RESUMEN

Osteosarcomas are the most common primary malignant bone tumors and are classified by the WHO into several intramedullary and surface subtypes. One of these is the rare parosteal osteosarcoma. Liposarcomas are the second most common soft tissue sarcoma and are classified into several types ranging from intermediate to high grade tumors. In one of our recent patients we found an unusual combination of a parosteal osteosarcoma and a large fatty component, which fluorescence-in-situ-hybridization revealed as liposarcoma. Radiologists, pathologists, and surgeons should consider the possibility of bone and soft tissue malignancies consisting of different components, as this may be of paramount importance for oncologically complete resection.

10.
J Med Case Rep ; 16(1): 73, 2022 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-35180884

RESUMEN

BACKGROUND: Splenosis is the heterotopic autotransplantation of splenic tissue after severe splenic trauma and/or splenectomy. The epidemiology is elusive, but splenosis is frequently misdiagnosed as malignant tumors of gastrointestinal, gynecological, or hematological origin before the correct diagnosis is ultimately found. We herein report a rare case of combined, extensive intraabdominal and intrathoracic splenosis initially presenting as pleural mesothelioma. CASE PRESENTATION: A 63-year-old Caucasian male presented with dyspnea and recurring thoracic pain. Initial X-ray and computed tomography scans showed disseminated intrathoracic and intraabdominal lesions. Consequently, thoracoabdominal mesothelioma or a polytopically metastasized cancer of unknown origin was suspected. A thorough examination of the patient's medical history and contrast-enhanced ultrasound by a skilled examiner revealed the diagnosis of extensive abdominal and thoracic splenosis as a consequence of an abdominal gunshot wound with a ruptured diaphragm several decades earlier. Timely diagnosis by noninvasive measures prevented the patient from potential complications of harmful diagnostic procedures, including nuclear imaging and biopsies. The patient is currently treated for hepatitis C and chronic obstructive lung disease, whereas no specific treatment for splenosis is required. CONCLUSIONS: We present a case of rare intrathoracic and intraperitoneal splenosis mimicking mesothelioma. Contrast-enhanced ultrasound and thorough patient history were used for diagnosis and prevented this patient from having to undergo potentially harmful diagnostics. Splenosis can occur after splenic trauma and, consequently, needs to be considered as a rare differential diagnosis to malignant tumors of various origins when a matching patient history is obtained.


Asunto(s)
Traumatismos Abdominales , Mesotelioma , Esplenosis , Heridas por Arma de Fuego , Traumatismos Abdominales/complicaciones , Diagnóstico Diferencial , Humanos , Masculino , Mesotelioma/complicaciones , Mesotelioma/diagnóstico por imagen , Persona de Mediana Edad , Esplenectomía , Esplenosis/diagnóstico por imagen , Esplenosis/etiología , Heridas por Arma de Fuego/complicaciones
11.
J Vasc Interv Radiol ; 33(4): 384-391.e7, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34958860

RESUMEN

PURPOSE: To evaluate the feasibility and accuracy of a radiation-free implantation of a thoracic aortic stent graft employing fiberoptic and electromagnetic tracking in an anthropomorphic phantom. MATERIALS AND METHODS: An anthropomorphic phantom was manufactured based on computed tomography (CT) angiography data from a patient. An aortic stent graft application system was equipped with a fiber Bragg gratings and 3 electromagnetic sensors. The stent graft was navigated in the phantom by 3 interventionalists using the tracking data generated by both technologies. One implantation procedure was performed. The technical success of the procedure was evaluated using digital subtraction angiography and CT angiography (before and after the intervention). Tracking accuracy was determined at various anatomical landmarks based on separately acquired fluoroscopic images. The mean/maximum errors were measured for the stent graft application system and the tip/end of the stent graft. RESULTS: The procedure resulted in technical success with a mean error below 3 mm for the entire application system and <2 mm for the position of the tip of the stent graft. Navigation/implantation and handling of the device were rated sufficiently accurate and on par with comparable, routinely used stent graft application systems. CONCLUSIONS: The study demonstrates successful stent graft implantation during a thoracic endovascular aortic repair procedure employing advanced guidance techniques and avoiding fluoroscopic imaging. This is an essential step in facilitating the implantation of stent grafts and reducing the health risks associated with ionizing radiation during endovascular procedures.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Fenómenos Electromagnéticos , Humanos , Imagenología Tridimensional , Stents , Resultado del Tratamiento
12.
Eur Radiol ; 32(1): 690-701, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34170365

RESUMEN

OBJECTIVES: To develop and validate a deep learning-based algorithm for segmenting and quantifying the physiological and diseased aorta in computed tomography angiographies. METHODS: CTA exams of the aorta of 191 patients (68.1 ± 14 years, 128 male), performed between 2015 and 2018, were retrospectively identified from our imaging archive and manually segmented by two investigators. A 3D U-Net model was trained on the data, which was divided into a training, a validation, and a test group at a ratio of 7:1:2. Cases in the test group (n = 41) were evaluated to compare manual and automatic segmentations. Dice similarity coefficient (DSC), mean surface distance (MSD), and Hausdorff surface distance (HSD) were extracted. Maximum diameter, effective diameter, and area were quantified and compared between both segmentations at eight anatomical landmarks, and at the maximum area of an aneurysms if present (n = 14). Statistics included error calculation, intraclass correlation coefficient, and Bland-Altman analysis. RESULTS: A DSC of 0.95 [0.94; 0.95] and an MSD of 0.76 [0.06; 0.99] indicated close agreement between segmentations. HSD was 8.00 [4.47; 10.00]. The largest absolute errors were found in the ascending aorta with 0.8 ± 1.5 mm for maximum diameter and at the coeliac trunk with - 30.0 ± 81.6 mm2 for area. Results for absolute errors in aneurysms were - 0.5 ± 2.3 mm for maximum diameter, 0.3 ± 1.6 mm for effective diameter, and 64.9 ± 114.9 mm2 for area. ICC showed excellent agreement (> 0.9; p < 0.05) between quantitative measurements. CONCLUSIONS: Automated segmentation of the aorta on CTA data using a deep learning algorithm is feasible and allows for accurate quantification of the aortic lumen even if the vascular architecture is altered by disease. KEY POINTS: • A deep learning-based algorithm can automatically segment the aorta, mostly within acceptable margins of error, even if the vascular architecture is altered by disease. • Quantifications performed in the segmentations were mostly within clinically acceptable limits, even in pathologically altered segments of the aorta.


Asunto(s)
Angiografía por Tomografía Computarizada , Aprendizaje Profundo , Algoritmos , Aorta/diagnóstico por imagen , Humanos , Masculino , Estudios Retrospectivos
13.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-34409435

RESUMEN

OBJECTIVES: This is a comprehensive analysis of haemodynamics after valve-sparing aortic root replacement (VSARR) with anatomically curved prosthesis (CP) compared to straight prosthesis (SP) and age-matched volunteers (VOL) using 4D flow MRI (time-resolved three-dimensional magnetic resonance phase-contrast imaging). METHODS: Nine patients with 90° CP, nine patients with SP, and twelve VOL were examined with 4D flow MRI. Analyses included various characteristic anatomical, qualitative and quantitative haemodynamic parameters. RESULTS: Grading of secondary flow patterns was lower in CP patients than in SP patients (P = 0.09) and more comparable to VOL, albeit not reaching statistical significance. However, it was easy to differentiate between VSARR patients and healthy volunteers: Patients more often had angular aortic arches (CP: 89%, SP: 100%; VOL: 17%; P ≤ 0.002), increased average curvature (CP: 0.17/cm [0.15, 0.18]; SP: 0.15/cm [0.14, 0.16]; VOL: 0.14/cm [0.13, 0.16]; P ≤ 0.007; values given as median [interquartile range]), and more secondary flow patterns (CP: 3 [2, 4] SP: 3 [2, 3] VOL: 2 [1, 2]; P < 0.01). Maximum circulation (CP: 142.7 cm2/s [116.1, 187.3]; SP: 101.8 cm2/s [77.7, 132.5]; VOL: 42.8cm2/s [39.3, 65.6]; P ≤ 0.002), maximum helicity density (CP: 9.6 m/s2 [9.3, 23.9]; SP: 9.7 m/s2 [8.6, 12.5]; VOL 4.9 m/s2 [4.2, 7.7]; P ≤ 0.007), and wall shear stress gradient (e.g., proximal ascending aorta CP: 0.97 N/m2 [0.54, 1.07]; SP: 1.08 N/m2 [0.74, 1.24]; VOL: 0.41 N/m2 [0.32, 0.60]; P ≤ 0.01) were increased in patients. One CP patient had a round aortic arch with physiological haemodynamic parameters. CONCLUSIONS: The restoration of physiological aortic configuration and haemodynamics was not fully achieved with the curved prostheses in our study cohort. However, there was a tendency towards improved haemodynamic conditions in the patients with curved prostheses overall but without statistical significance. A single patient with a CP and near-physiological configuration of the thoracic aorta underlines the importance of optimizing postoperative geometric conditions for allowing for physiological haemodynamics and cardiovascular energetics after VSARR.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Aorta/diagnóstico por imagen , Aorta/fisiología , Aorta/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Velocidad del Flujo Sanguíneo/fisiología , Hemodinámica/fisiología , Humanos , Imagen por Resonancia Magnética/métodos
14.
Rofo ; 194(2): 181-191, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34384112

RESUMEN

PURPOSE: In the light of the increasing importance of cardiovascular cross-sectional imaging in current guidelines, the goal of this study is to provide a comprehensive overview of cardiovascular imaging (CVI) offered by radiological institutions across Germany. MATERIALS AND METHODS: Data were extracted from the national certification program database of the German Roentgen Society (DRG) from 2015-2021. A nationwide online survey among radiology institutes (university hospitals, non-university hospitals, and private practices) was conducted for 2019, and data was extracted from the European Society of Cardiovascular Radiology (ESCR) registry. The data collection's key points included the number of centers and individuals certified for CVI, the number of cardiac CT and MRI examinations performed, the reporting habits, and the participation in the ESCR registry. RESULTS: 71 centers and 1278 persons, both with a substantial increase since 2015, were registered and certified by the DRG to perform CVI. According to the survey, a total of 69,286 CT and 64,281 MRI examinations were performed annually. Data from the survey and the ESCR registry indicated that reporting was mostly done solely by radiologists or, to a lesser degree, in joint consensus meetings with non-radiologists. The overall participation rate in the ESCR registry was 48 % among the survey's participants. CONCLUSION: This comprehensive analysis demonstrates that high-quality CVI by radiologists is available nationwide. The current challenges are to provide the best medical and technical quality of CVI by radiology for patient care and to ensure economic sustainability in the German health care system to accommodate the predicted substantial need for CVI in the future. KEY POINTS: · High-quality advanced CVI service by radiologists is available nationwide.. · Highly qualified specialist knowledge is widely represented from university to private practices.. · Certification programs successfully contribute to the dissemination & deepening of CVI expertise.. · The ESCR registry is an established international tool for the documentation of CVI.. CITATION FORMAT: · Sieren M, Maintz D, Gutberlet M et al. Current Status of Cardiovascular Imaging in Germany: Structured Data from the National Certification Program, ESCR Registry, and Survey among Radiologists. Fortschr Röntgenstr 2022; 194: 181 - 191.


Asunto(s)
Radiología , Certificación , Alemania , Humanos , Imagen por Resonancia Magnética/métodos , Radiólogos , Sistema de Registros
15.
Int J Med Robot ; 17(6): e2327, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34480406

RESUMEN

BACKGROUND: In endovascular aneuysm repair (EVAR) procedures, medical instruments are currently navigated with a two-dimensional imaging based guidance requiring X-rays and contrast agent. METHODS: Novel approaches for obtaining the three-dimensional instrument positions are introduced. Firstly, a method based on fibre optical shape sensing, one electromagnetic sensor and a preoperative computed tomography (CT) scan is described. Secondly, an approach based on image processing using one 2D fluoroscopic image and a preoperative CT scan is introduced. RESULTS: For the tracking based method, average errors from 1.81 to 3.13 mm and maximum errors from 3.21 to 5.46 mm were measured. For the image-based approach, average errors from 3.07 to 6.02 mm and maximum errors from 8.05 to 15.75 mm were measured. CONCLUSION: The tracking based method is promising for usage in EVAR procedures. For the image-based approach are applications in smaller vessels more suitable, since its errors increase with the vessel diameter.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Fluoroscopía , Humanos , Imagenología Tridimensional
16.
Int J Nanomedicine ; 16: 213-221, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33469281

RESUMEN

PURPOSE: Endovascular stents are medical devices, which are implanted in stenosed blood vessels to ensure sufficient blood flow. Due to a high rate of in-stent re-stenoses, there is the need of a noninvasive imaging method for the early detection of stent occlusion. The evaluation of the stent lumen with computed tomography (CT) and magnetic resonance imaging (MRI) is limited by material-induced artifacts. The purpose of this work is to investigate the potential of the tracer-based modality magnetic particle imaging (MPI) for stent lumen visualization and quantification. METHODS: In this in vitro study, 21 endovascular stents were investigated in a preclinical MPI scanner. Therefore, the stents were implanted in vessel phantoms. For the signal analysis, the phantoms were scanned without tracer material, and the signal-to-noise-ratio was analyzed. For the evaluation of potential artifacts and the lumen quantification, the phantoms were filled with diluted tracer agent. To calculate the stent lumen diameter a calibrated threshold value was applied. RESULTS: We can show that it is possible to visualize the lumen of a variety of endovascular stents without material induced artifacts, as the stents do not generate sufficient signals in MPI. The stent lumen quantification showed a direct correlation between the calculated and nominal diameter (r = 0.98). CONCLUSION: In contrast to MRI and CT, MPI is able to visualize and quantify stent lumina very accurately.


Asunto(s)
Procedimientos Endovasculares , Fenómenos Magnéticos , Procesamiento de Señales Asistido por Computador , Stents , Artefactos , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Relación Señal-Ruido , Tomografía Computarizada por Rayos X
17.
J Cardiovasc Magn Reson ; 22(1): 59, 2020 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-32772927

RESUMEN

BACKGROUND: Anatomically pre-shaped sinus prostheses (SP) were developed to mimic the aortic sinus with the goal to preserve near physiological hemodynamic conditions after valve-sparing aortic root replacement. Although SP have shown more physiological flow patterns, a comparison to straight tube prosthesis and the analysis of derived quantitative parameters is lacking. Hence, this study sought to analyze differences in aortic wall shear stress (WSS) between anatomically pre-shaped SP, conventional straight tube prostheses (TP), and age-matched healthy subjects) using time-resolved 3-dimensional flow cardiovascular magnetic resonance (4D Flow CMR). Moreover, the WSS gradient was introduced and analyzed regarding its sensitivity to detect changes in hemodynamics and its dependency on the expression of secondary flow patterns. METHODS: Twelve patients with SP (12 male, 62 ± 9yr), eight patients with TP (6 male, 59 ± 9yr), and twelve healthy subjects (2 male, 55 ± 6yr) were examined at 3 T with a 4D Flow CMR sequence in this case control study. Six analysis planes were placed in the thoracic aorta at reproducible landmarks. The following WSS parameters were recorded: WSSavg (spatially averaged over the contour at peak systole), max. WSSseg (maximum segmental WSS), min. WSSseg (minimum segmental WSS) and the WSS Gradient, calculated as max. WSSseg - min. WSSseg. Kruskal-Wallis- and Mann-Whitney-U-Test were used for statistical comparison of groups. Occurrence and expression of secondary flow patterns were evaluated and correlated to WSS values using Spearman's correlation coefficient. RESULTS: In the planes bordering the prosthesis all WSS values were significantly lower in the SP compared to the TP, approaching the physiological optimum of the healthy subjects. The WSS gradient showed significantly different values in the four proximally localized contours when comparing both prostheses with healthy subjects. Strong correlations between an elevated WSS gradient and secondary flow patterns were found in the ascending aorta and the aortic arch. CONCLUSION: Overall, the SP has a positive impact on WSS, most pronounced at the site and adjacent to the prosthesis. The WSS gradient differed most obviously and the correlation of the WSS gradient with the occurrence of secondary flow patterns provides further evidence for linking disturbed flow, which was markedly increased in patients compared to healthy sub jects, to degenerative remodeling of the vascular wall.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Válvula Aórtica/diagnóstico por imagen , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Hemodinámica , Imagen por Resonancia Magnética , Imagen de Perfusión/métodos , Diseño de Prótesis , Adulto , Anciano , Aorta Torácica/fisiopatología , Válvula Aórtica/fisiopatología , Técnicas de Imagen Sincronizada Cardíacas , Estudios de Casos y Controles , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Estrés Mecánico , Resultado del Tratamiento
18.
JACC Clin Electrophysiol ; 6(7): 773-782, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32703558

RESUMEN

OBJECTIVES: This study sought to assess the incidence, procedural characteristics, contributing factors, and clinical outcome of cryoballoon-based pulmonary vein isolation (CB-PVI)-related hemoptysis in a multicenter study. BACKGROUND: Hemoptysis has been described as a rare complication of CB-PVI. However, the precise mechanism and the etiology of this complication are poorly characterized. METHODS: Consecutive patients undergoing CB-PVI for paroxysmal or persistent atrial fibrillation at 4 German hospitals were included in this observational analysis. RESULTS: A total of 4,331 CB-PVI procedures were performed between 2006 and 2019. Fifteen patients (9 men, mean age 68.1 ± 9.8 years) developed acute hemoptysis during or within 24 h after CB-PVI, resulting in a hemoptysis frequency of 0.35%. Hemoptysis occurred in 6 of 720 procedures using the first-generation CB (0.83%) and in 9 of 3,611 procedures using the second-, third-, or fourth-generation CB (0.25%) (p = 0.015). Bronchoscopy was performed in 8 patients and showed bleeding exclusively due to mucosal injury or due to a coagulum at a bronchus adjacent to the ablation site. Hemoptysis resolved spontaneously without any long-term sequelae in all patients, except for a 92-year-old patient who died 13 days after CB-PVI due to pneumonia. No specific endobronchial treatment was necessary. CONCLUSIONS: Acute hemoptysis after CB-PVI is a rare but potentially life-threatening complication that is usually self-limiting. Direct thermal injury of bronchi adjacent to a pulmonary vein seems to be the most likely mechanism.


Asunto(s)
Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Anciano de 80 o más Años , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Hemoptisis/epidemiología , Hemoptisis/etiología , Humanos , Masculino , Venas Pulmonares/cirugía , Resultado del Tratamiento
19.
Int J Comput Assist Radiol Surg ; 15(6): 1033-1042, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32383105

RESUMEN

PURPOSE: During endovascular aneurysm repair (EVAR) procedures, medical instruments are guided with two-dimensional (2D) fluoroscopy and conventional digital subtraction angiography. However, this requires X-ray exposure and contrast agent is used, and the depth information is missing. To overcome these drawbacks, a three-dimensional (3D) guidance approach based on tracking systems is introduced and evaluated. METHODS: A multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape were integrated into a stentgraft system. A model for obtaining the located shape of the first 38 cm of the stentgraft system with two EM sensors is introduced and compared with a method based on three EM sensors. Both methods were evaluated with a vessel phantom containing a 3D-printed vessel made of silicone and agar-agar simulating the surrounding tissue. RESULTS: The evaluation of the guidance methods resulted in average errors from 1.35 to 2.43 mm and maximum errors from 3.04 to 6.30 mm using three EM sensors, and average errors from 1.57 to 2.64 mm and maximum errors from 2.79 to 6.27 mm using two EM sensors. Moreover, the videos made from the continuous measurements showed that a real-time guidance is possible with both approaches. CONCLUSION: The results showed that an accurate real-time guidance with two and three EM sensors is possible and that two EM sensors are already sufficient. Thus, the introduced 3D guidance method is promising to use it as navigation tool in EVAR procedures. Future work will focus on developing a method with less EM sensors and a detailed latency evaluation of the guidance method.


Asunto(s)
Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Imagenología Tridimensional/métodos , Angiografía de Substracción Digital , Procedimientos Endovasculares/métodos , Fluoroscopía , Humanos , Fantasmas de Imagen
20.
PLoS One ; 14(10): e0224121, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31648286

RESUMEN

PURPOSE: 4D and 2D phase-contrast MRI (2D Flow MRI, 4D Flow MRI, respectively) are increasingly being used to noninvasively assess pulmonary hypertension (PH). The goals of this study were i) to evaluate whether established quantitative parameters in 2D Flow MRI associated with pulmonary hypertension can be assessed using 4D Flow MRI; ii) to compare results from 4D Flow MRI on a digital broadband 3T MR system with data from clinically established MRI-techniques as well as conservation of mass analysis and phantom correction and iii) to elaborate on the added value of secondary flow patterns in detecting PH. METHODS: 11 patients with PH (4f, 63 ± 16y), 15 age-matched healthy volunteers (9f, 56 ± 11y), and 20 young healthy volunteers (13f, 23 ± 2y) were scanned on a 3T MR scanner (Philips Ingenia). Subjects were examined with a 4D Flow, a 2D Flow and a bSSFP sequence. For extrinsic comparison, quantitative parameters measured with 4D Flow MRI were compared to i) a static phantom, ii) 2D Flow acquisitions and iii) stroke volume derived from a bSSFP sequence. For intrinsic comparison conservation of mass-analysis was employed. Dedicated software was used to extract various flow, velocity, and anatomical parameters. Visualization of blood flow was performed to detect secondary flow patterns. RESULTS: Overall, there was good agreement between all techniques, 4D Flow results revealed a considerable spread. Data improved after phantom correction. Both 4D and 2D Flow MRI revealed concordant results to differentiate patients from healthy individuals, especially based on values derived from anatomical parameters. The visualization of a vortex, indicating the presence of PH was achieved in 9 /11 patients and 2/35 volunteers. DISCUSSION: This study confirms that quantitative parameters used for characterizing pulmonary hypertension can be gathered using 4D Flow MRI within clinically reasonable limits of agreement. Despite its unfavorable spatial and lesser temporal resolution and a non-neglible spread of results, the identification of diseased study participants was possible.


Asunto(s)
Algoritmos , Hipertensión Pulmonar/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Adulto , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Femenino , Voluntarios Sanos , Hemodinámica , Humanos , Masculino , Arteria Pulmonar , Volumen Sistólico