Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biophys J ; 120(13): 2657-2664, 2021 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-34087217

RESUMEN

The question of how much information the photoplethysmogram (PPG) signal contains on the autonomic regulation of blood pressure (BP) remains unsolved. This study aims to compare the low-frequency (LF) and high-frequency components of PPG and BP and assess their correlation with oscillations in interbeat (RR) intervals at similar frequencies. The PPG signal from the distal phalanx of the right index finger recorded using a reflective PPG sensor at green light, the BP signal from the left hand recorded using a Finometer, and RR intervals were analyzed. These signals were simultaneously recorded within 15 min in a supine resting condition in 17 healthy subjects (12 males and 5 females) aged 33 ± 9 years (mean ± SD). The study revealed the high coherence of LF components of PPG and BP with the LF component of RR intervals. The high-frequency components of these signals had low coherence. The analysis of the signal instantaneous phases revealed the presence of high-phase coherence between the LF components of PPG and BP. It is shown that the LF component of PPG is determined not only by local myogenic activity but also reflects the processes of autonomic control of BP.


Asunto(s)
Fotopletismografía , Presión Sanguínea , Femenino , Frecuencia Cardíaca , Humanos , Masculino
2.
Sci Rep ; 10(1): 16525, 2020 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-33020530

RESUMEN

A mathematical model is proposed for the autonomic control of cardiovascular system, which takes into account two separated self-exciting sympathetic control loops of heart rate and peripheral vascular tone. The control loops are represented by self-exciting time-delay systems and their tone depends on activity of the aortic, carotid, and lower-body baroreceptors. The model is used to study the dynamics of the adaptive processes that manifest in a healthy cardiovascular system during the passive head-up tilt test. Computer simulation provides continuous observation of the dynamics of the indexes and variables that cannot be measured in the direct experiment, including the noradrenaline concentration in vessel wall and heart muscle, tone of the sympathetic and parasympathetic control, peripheral vascular resistance, and blood pressure. In the supine and upright positions, we estimated the spectral characteristics of the model variables, especially in the low-frequency band, and the original index of total percent of phase synchronization between the low-frequency oscillations in heart rate and blood pressure signals. The model demonstrates good quantitative agreement with the dynamics of the experimentally observed indexes of cardiovascular system that were averaged for 50 healthy subjects.


Asunto(s)
Sistema Nervioso Autónomo/fisiología , Sistema Cardiovascular/inervación , Adulto , Barorreflejo/fisiología , Presión Sanguínea/fisiología , Simulación por Computador , Femenino , Cabeza , Voluntarios Sanos , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Modelos Teóricos , Postura/fisiología , Pruebas de Mesa Inclinada
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...