Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
PLoS One ; 11(10): e0163704, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27727294

RESUMEN

Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI) using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.


Asunto(s)
Imagen por Resonancia Magnética , Calibración , Radioisótopos de Flúor/química , Gadolinio/química , Límite de Detección , Imagen por Resonancia Magnética/normas , Modelos Teóricos , Relación Señal-Ruido
2.
Proc Natl Acad Sci U S A ; 113(12): 3164-8, 2016 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-26961001

RESUMEN

Hyperpolarized (hp) (83)Kr is a promising MRI contrast agent for the diagnosis of pulmonary diseases affecting the surface of the respiratory zone. However, the distinct physical properties of (83)Kr that enable unique MRI contrast also complicate the production of hp (83)Kr. This work presents a previously unexplored approach in the generation of hp (83)Kr that can likewise be used for the production of hp (129)Xe. Molecular nitrogen, typically used as buffer gas in spin-exchange optical pumping (SEOP), was replaced by molecular hydrogen without penalty for the achievable hyperpolarization. In this particular study, the highest obtained nuclear spin polarizations were P =29% for(83)Kr and P= 63% for (129)Xe. The results were reproduced over many SEOP cycles despite the laser-induced on-resonance formation of rubidium hydride (RbH). Following SEOP, the H2 was reactively removed via catalytic combustion without measurable losses in hyperpolarized spin state of either (83)Kr or (129)Xe. Highly spin-polarized (83)Kr can now be purified for the first time, to our knowledge, to provide high signal intensity for the advancement of in vivo hp (83)Kr MRI. More generally, a chemical reaction appears as a viable alternative to the cryogenic separation process, the primary purification method of hp(129)Xe for the past 2 1/2 decades. The inherent simplicity of the combustion process will facilitate hp (129)Xe production and should allow for on-demand continuous flow of purified and highly spin-polarized (129)Xe.


Asunto(s)
Medios de Contraste , Hidrógeno/química , Criptón/química , Xenón/química , Catálisis , Imagen por Resonancia Magnética
3.
Magn Reson Med ; 76(4): 1224-35, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-26507239

RESUMEN

PURPOSE: Asthma is a disease of increasing worldwide importance that calls for new investigative methods. Ex vivo lung tissue is being increasingly used to study functional respiratory parameters independent of confounding systemic considerations but also to reduce animal numbers and associated research costs. In this work, a straightforward laboratory method is advanced to probe dynamic changes in gas inhalation patterns by using an ex vivo small animal ovalbumin (OVA) model of human asthma. METHODS: Hyperpolarized (hp) (129) Xe was actively inhaled by the excised lungs exposed to a constant pressure differential that mimicked negative pleural cavity pressure. The method enabled hp (129) Xe MRI of airway responsiveness to intravenous methacholine (MCh) and airway challenge reversal through salbutamol. RESULTS: Significant differences were demonstrated between control and OVA challenged animals on global lung hp (129) Xe gas inhalation with P < 0.05 at MCh dosages above 460 µg. Spatial mapping of the regional hp gas distribution revealed an approximately three-fold increase in heterogeneity for the asthma model organs. CONCLUSION: The experimental results from this proof of concept work suggest that the ex vivo hp noble gas imaging arrangement and the applied image analysis methodology may be useful as an adjunct to current diagnostic techniques. Magn Reson Med 76:1224-1235, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Asma/diagnóstico por imagen , Asma/fisiopatología , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Imagen por Resonancia Magnética/métodos , Intercambio Gaseoso Pulmonar , Isótopos de Xenón/farmacocinética , Administración por Inhalación , Animales , Simulación por Computador , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Modelos Biológicos , Imagen Molecular/métodos , Radiofármacos/administración & dosificación , Radiofármacos/farmacocinética , Ratas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular , Isótopos de Xenón/administración & dosificación
4.
J R Soc Interface ; 12(107)2015 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-25994296

RESUMEN

Hyperpolarized (83)Kr surface quadrupolar relaxation (SQUARE) generates MRI contrast that was previously shown to correlate with surface-to-volume ratios in porous model surface systems. The underlying physics of SQUARE contrast is conceptually different from any other current MRI methodology as the method uses the nuclear electric properties of the spin I = 9/2 isotope (83)Kr. To explore the usage of this non-radioactive isotope for pulmonary pathophysiology, MRI SQUARE contrast was acquired in excised rat lungs obtained from an elastase-induced model of emphysema. A significant (83)Kr T1 relaxation time increase in the SQUARE contrast was found in the elastase-treated lungs compared with the baseline data from control lungs. The SQUARE contrast suggests a reduction in pulmonary surface-to-volume ratio in the emphysema model that was validated by histology. The finding supports usage of (83)Kr SQUARE as a new biomarker for surface-to-volume ratio changes in emphysema.


Asunto(s)
Medios de Contraste/farmacología , Criptón/farmacología , Modelos Teóricos , Alveolos Pulmonares/diagnóstico por imagen , Enfisema Pulmonar/diagnóstico por imagen , Animales , Modelos Animales de Enfermedad , Imagen por Resonancia Magnética , Enfisema Pulmonar/inducido químicamente , Radiografía , Ratas
5.
Magn Reson Imaging ; 32(1): 48-53, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24144493

RESUMEN

Hyperpolarized (83)Kr has previously been demonstrated to enable MRI contrast that is sensitive to the chemical composition of the surface in a porous model system. Methodological advances have lead to a substantial increase in the (83)Kr hyperpolarization and the resulting signal intensity. Using the improved methodology for spin exchange optical pumping of isotopically enriched (83)Kr, internal anatomical details of ex vivo rodent lung were resolved with hyperpolarized (83)Kr MRI after krypton inhalation. Different (83)Kr relaxation times were found between the main bronchi and the parenchymal regions in ex vivo rat lungs. The T1 weighted hyperpolarized (83)Kr MRI provided a first demonstration of surface quadrupolar relaxation (SQUARE) pulmonary MRI contrast.


Asunto(s)
Medios de Contraste/química , Criptón/química , Imagen por Resonancia Magnética/métodos , Animales , Bronquios/patología , Gases , Procesamiento de Imagen Asistido por Computador , Isótopos/química , Pulmón/patología , Masculino , Óptica y Fotónica , Surfactantes Pulmonares/química , Ratas , Ratas Sprague-Dawley , Propiedades de Superficie , Factores de Tiempo
6.
J Magn Reson ; 237: 23-33, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24135800

RESUMEN

As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp (129)Xe or hp (83)Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp (129)Xe handling, while (83)Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The (83)Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of (129)Xe in corresponding mixtures. The experimental setup also facilitated (129)Xe T1 relaxation measurements as a function of O2 concentration within excised lungs.


Asunto(s)
Criptón/química , Imagen por Resonancia Magnética/métodos , Isótopos de Xenón/química , Algoritmos , Animales , Medios de Contraste , Gases , Interpretación de Imagen Asistida por Computador , Isótopos , Pulmón/anatomía & histología , Masculino , Oxígeno/química , Ratas , Ratas Sprague-Dawley , Respiración Artificial , Rubidio/química
7.
PLoS One ; 8(8): e73468, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24023683

RESUMEN

Ex vivo rodent lung models are explored for physiological measurements of respiratory function with hyperpolarized (hp) (129)Xe MRI. It is shown that excised lung models allow for simplification of the technical challenges involved and provide valuable physiological insights that are not feasible using in vivo MRI protocols. A custom designed breathing apparatus enables MR images of gas distribution on increasing ventilation volumes of actively inhaled hp (129)Xe. Straightforward hp (129)Xe MRI protocols provide residual lung volume (RV) data and permit for spatially resolved tracking of small hp (129)Xe probe volumes during the inhalation cycle. Hp (129)Xe MRI of lung function in the excised organ demonstrates the persistence of post mortem airway responsiveness to intravenous methacholine challenges. The presented methodology enables physiology of lung function in health and disease without additional regulatory approval requirements and reduces the technical and logistical challenges with hp gas MRI experiments. The post mortem lung functional data can augment histological measurements and should be of interest for drug development studies.


Asunto(s)
Disección , Pulmón/fisiología , Imagen por Resonancia Magnética , Xenón , Animales , Cobayas , Humanos , Inhalación/fisiología , Masculino , Ventilación Pulmonar/fisiología , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Volumen Residual/fisiología , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Isótopos de Xenón
8.
Phys Chem Chem Phys ; 15(1): 94-7, 2013 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-23165418

RESUMEN

Using a methane-xenon mixture for spin exchange optical pumping, MRI of combustion was enabled. The (129)Xe hyperpolarized nuclear spin state was found to sufficiently survive the complete passage through the harsh environment of the reaction zone. A velocity profile (V(z)(z)) of a flame was recorded to demonstrate the feasibility of MRI velocimetry of transport processes in combustors.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Metano/química , Isótopos de Xenón/química , Diseño de Equipo , Combustibles Fósiles/análisis , Gases/química , Calor , Presión
9.
PLoS One ; 7(11): e49927, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23209620

RESUMEN

Hyperpolarized (hp) (129)Xe and hp (83)Kr for magnetic resonance imaging (MRI) are typically obtained through spin-exchange optical pumping (SEOP) in gas mixtures with dilute concentrations of the respective noble gas. The usage of dilute noble gases mixtures requires cryogenic gas separation after SEOP, a step that makes clinical and preclinical applications of hp (129)Xe MRI cumbersome. For hp (83)Kr MRI, cryogenic concentration is not practical due to depolarization that is caused by quadrupolar relaxation in the condensed phase. In this work, the concept of stopped flow SEOP with concentrated noble gas mixtures at low pressures was explored using a laser with 23.3 W of output power and 0.25 nm linewidth. For (129)Xe SEOP without cryogenic separation, the highest obtained MR signal intensity from the hp xenon-nitrogen gas mixture was equivalent to that arising from 15.5±1.9% spin polarized (129)Xe in pure xenon gas. The production rate of the hp gas mixture, measured at 298 K, was 1.8 cm(3)/min. For hp (83)Kr, the equivalent of 4.4±0.5% spin polarization in pure krypton at a production rate of 2 cm(3)/min was produced. The general dependency of spin polarization upon gas pressure obtained in stopped flow SEOP is reported for various noble gas concentrations. Aspects of SEOP specific to the two noble gas isotopes are discussed and compared with current theoretical opinions. A non-linear pressure broadening of the Rb D(1) transition was observed and taken into account for the qualitative description of the SEOP process.


Asunto(s)
Criptón/química , Imagen por Resonancia Magnética/métodos , Isótopos de Xenón/química , Humanos , Isótopos , Rayos Láser , Gases Nobles/química , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...