Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pediatr Blood Cancer ; 71(11): e31185, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39118225

RESUMEN

Historically, total body irradiation (TBI) has been delivered using static, parallel opposed photon beams (2D-TBI). Recently, centers have increasingly used intensity-modulated radiation therapy (IMRT) techniques for TBI. Relative to 2D-TBI, IMRT can reduce doses to critical organs (i.e., lungs and kidneys) while delivering myeloablative doses to the rest of the body, so it may decrease the risk of toxicity while maintaining oncologic outcomes. Despite these potential benefits, delivering TBI using IMRT introduces new challenges in treatment planning and delivery. We describe the extensive experience with IMRT-based TBI at Stanford University and City of Hope Cancer Center. These groups, and others, have reported favorable clinical outcomes and have developed methods to optimize treatment planning and delivery. A critical next step is to evaluate the broader adoption of this approach. Therefore, IMRT-based TBI will be incorporated into a prospective, multi-institutional Children's Oncology Group study with careful procedures and safeguards in place.


Asunto(s)
Radioterapia de Intensidad Modulada , Irradiación Corporal Total , Humanos , Irradiación Corporal Total/métodos , Radioterapia de Intensidad Modulada/métodos , Niño , Neoplasias/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica
2.
Technol Cancer Res Treat ; 19: 1533033820920650, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32329413

RESUMEN

BACKGROUND: Lower-dose cone-beam computed tomography protocols for image-guided radiotherapy may permit target localization while minimizing radiation exposure. We prospectively evaluated a lower-dose cone-beam protocol for central nervous system image-guided radiotherapy across a multinational pediatrics consortium. METHODS: Seven institutions prospectively employed a lower-dose cone-beam computed tomography central nervous system protocol (weighted average dose 0.7 mGy) for patients ≤21 years. Treatment table shifts between setup with surface lasers versus cone-beam computed tomography were used to approximate setup accuracy, and vector magnitudes for these shifts were calculated. Setup group mean, interpatient, interinstitution, and random error were estimated, and clinical factors were compared by mixed linear modeling. RESULTS: Among 96 patients, with 2179 pretreatment cone-beam computed tomography acquisitions, median age was 9 years (1-20). Setup parameters were 3.13, 3.02, 1.64, and 1.48 mm for vector magnitude group mean, interpatient, interinstitution, and random error, respectively. On multivariable analysis, there were no significant differences in mean vector magnitude by age, gender, performance status, target location, extent of resection, chemotherapy, or steroid or anesthesia use. Providers rated >99% of images as adequate or better for target localization. CONCLUSIONS: A lower-dose cone-beam computed tomography protocol demonstrated table shift vector magnitude that approximate clinical target volume/planning target volume expansions used in central nervous system radiotherapy. There were no significant clinical predictors of setup accuracy identified, supporting use of this lower-dose cone-beam computed tomography protocol across a diverse pediatric population with brain tumors.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia/prevención & control , Adolescente , Adulto , Neoplasias Encefálicas/patología , Niño , Preescolar , Tomografía Computarizada de Haz Cónico/métodos , Femenino , Humanos , Lactante , Cooperación Internacional , Masculino , Pediatría/métodos , Estudios Prospectivos , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen/métodos , Adulto Joven
3.
J Oncol Pract ; 10(5): e350-7, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25095825

RESUMEN

PURPOSE: Incident learning systems are important tools to improve patient safety in radiation oncology, but physician participation in these systems is poor. To understand reporting practices and attitudes, a survey was sent to staff members of four large academic radiation oncology centers, all of which have in-house reporting systems. METHODS: Institutional review board approval was obtained to send a survey to employees including physicians, dosimetrists, nurses, physicists, and radiation therapists. The survey evaluated barriers to reporting, perceptions of errors, and reporting practices. The responses of physicians were compared with those of other professional groups. RESULTS: There were 274 respondents to the survey, with a response rate of 81.3%. Physicians and other staff agreed that errors and near-misses were happening in their clinics (93.8% v 88.7%, respectively) and that they have a responsibility to report (97% overall). Physicians were significantly less likely to report minor near-misses (P = .001) and minor errors (P = .024) than other groups. Physicians were significantly more concerned about getting colleagues in trouble (P = .015), liability (P = .009), effect on departmental reputation (P = .006), and embarrassment (P < .001) than their colleagues. Regression analysis identified embarrassment among physicians as a critical barrier. If not embarrassed, participants were 2.5 and 4.5 times more likely to report minor errors and major near-miss events, respectively. CONCLUSIONS: All members of the radiation oncology team observe errors and near-misses. Physicians, however, are significantly less likely to report events than other colleagues. There are important, specific barriers to physician reporting that need to be addressed to encourage reporting and create a fair culture around reporting.


Asunto(s)
Actitud del Personal de Salud , Oncología por Radiación/normas , Recolección de Datos , Humanos , Errores Médicos/prevención & control , Análisis Multivariante , Seguridad del Paciente , Médicos , Oncología por Radiación/organización & administración , Gestión de Riesgos , Encuestas y Cuestionarios
4.
Med Phys ; 35(2): 769-74, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18383699

RESUMEN

Superficial doses were measured for static TomoTherapy Hi-Art beams for normal and oblique incidence. Dose was measured at depths < or = 2 cm along the central axis of 40 x 5 cm2 and 40 x 2.5 cm2 beams at normal incidence for source to detector distances (SDDs) of 55, 70, and 85 cm. Measurements were also made at depths normal to the phantom surface for the same beams at oblique angles of 30 degrees, 45 degrees, 60 degrees, 75 degrees, and 83 degrees from the normal. Data were collected with a Gammex/RMI model 449 parallel-plate chamber embedded in a solid water phantom and with LiF thermoluminescent dosimeters (TLDs) in the form of powder. For comparison, measurements were made on a conventional 6 MV beam (Varian Clinac 2100C) at normal incidence and at an oblique angle of 60 degrees from the normal. TomoTherapy surface dose varied with the distance from the source and the angle of incidence. For normal incidence, surface dose increased from 0.16 to 0.43 cGy/MU as the distance from the source decreased from 85 to 55 cm for the 40 x 5 cm2 field and increased from 0.12 to 0.32 cGy/MU for the 40 x 2.5 cm2 field. As the angle of incidence increased from 0 degrees to 83 degrees, surface dose increased from 0.24 to 0.63 cGy/MU for the 40 x 5 cm2 field and from 0.18 to 0.58 cGy/MU for the 40 x 2.5 cm2 field. For normal incidence at 55 cm SDD, the surface dose relative to the dose at d(max) for the 40 x 5 cm2 TomoTherapy Hi-Art beam was 31% less than that from a conventional, flattening filter based linear accelerator. These data should prove useful in accessing the accuracy of the TomoTherapy treatment planning system to predict the dose at superficial depths for a static beam delivery.


Asunto(s)
Modelos Biológicos , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Carga Corporal (Radioterapia) , Simulación por Computador , Humanos , Fotones/uso terapéutico , Dosificación Radioterapéutica , Efectividad Biológica Relativa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...