Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 220
Filtrar
1.
Surg Technol Int ; 442024 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-38697137

RESUMEN

Given recent advancements in artificial intelligence and robotic surgery, attention has now been paid to the concept of autonomous surgery. As robotic surgery has developed and matured, examples of autonomous surgery have arisen through the assistance of artificial intelligence. As with any new technology, ethical and legal considerations also arise, and there are special considerations that should be taken into account with the adaptation of new technology involving patient care. In this paper, we will describe autonomous surgery used in general surgery and lower extremity joint arthroplasty, and we will highlight the current ethical and legal considerations associated with this technology.

2.
J Orthop ; 55: 32-37, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38638114

RESUMEN

Introduction: Robotic-arm-assisted unicompartmental knee arthroplasty (UKA) is an excellent solution for patients suffering from single-compartment knee arthritis. While outcomes tend to be favorable for UKAs, revision operations, commonly due to component malpositioning and malalignment resulting in accelerated wear, are a major concern. Intraoperative technologies, such as robotic assistance, can help better ensure that implants are positioned based on a patient's specific anatomy and mechanical physiology. However, long-term survivorship and patient-reported satisfaction with robotic-assisted UKAs are limited. Therefore, the purpose of this study was to assess the 10-year outcomes of patients who underwent robotic-arm-assisted unicompartmental knee arthroplasty. Specifically, we evaluated: 1) 10-year survivorships; 2) patient satisfaction scores; and 3) re-operations. Methods: From a single surgeon and single institution, 185 patients who had a mean age of 65 years (range, 39 to 92) and a mean body mass index of 31.6 (range, 22.4 to 39) at a mean of 10 years follow-up were evaluated (range, 9 to 11). For all patients, the same robotic-assistive device was utilized intraoperatively, and all patients underwent standardized physical therapy and received standardized pain control management. Then 10-year survivorships with Kaplan-Meir curves, patient satisfaction evaluations with a 5-point Likert scale, and re-operations were assessed as primary outcomes. Results: Overall implant survivorship was 99%, with only two patients requiring revision surgery. There was one patient who was converted to a total knee arthroplasty, while the other patient underwent polyethylene exchange at 5 weeks for an acute infection with successful implant retention. Overall, 97% of the patients were satisfied with their postoperative outcomes, with 81% of patients reporting being very satisfied. There were two other patients who required arthroscopic intervention: one to remove a cement loose body, the other to remove adhered scar from the fat pad and the anterior cruciate ligament. Conclusion: This study is one of the first to provide longer-term (mean 10-year) survivorship and patient-reported satisfaction outcomes for robotic-assisted UKA patients. These data show strong support for utilizing this surgical technique, as nearly all patients maintained their original prostheses and reported being satisfied after a mean of 10 years. Therefore, based on these results, we recommend the use of robotic assistance when performing UKAs.

3.
Surg Technol Int ; 442024 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-38547433

RESUMEN

INTRODUCTION: While dual mobility systems in total hip replacements have demonstrated reduced dislocation and revision occurrences, concerns persist about the potential elevation of metal ions in the bloodstream, leading to negative tissue reactions. Notably, there's a scarcity of research spanning over five years post-surgery that examines cobalt and chromium levels after such implants. This study aimed to delve into these metal ion concentrations after a five-year period, building on previous metal-ion findings. We focused on: (1) cobalt concentrations in blood and urine; (2) chromium concentrations in blood and urine; (3) cobalt variations based on follow-up duration and specific implant metrics (e.g., offset, cup dimension, stem, and neck inclination); and (4) chromium variations based on the same parameters. MATERIALS AND METHODS: We tracked 57 individuals who received THA using modular dual mobility systems from January 1, 2011, to December 31, 2016, for an average span of six years (ranging from five to 10 years). At the final check-up, we measured cobalt and chromium levels in serum, plasma, blood, and urine. We also evaluated parameters like head composition and dimension, stem offset, cup dimension, and stem-neck inclination. RESULTS: Cobalt concentrations remained minimal, with average blood and urine values being 0.8+0.6mcg/L (standard <1.8mcg/L) and 1.2+1.0mcg/L (standard <2.8mcg/L), respectively. Two individuals exhibited a slight increase in blood cobalt concentration by 0.1 and 0.2mcg/L. Chromium averages in blood and urine were also minimal, with readings of 0.9+0.2mcg/L (standard <1.2mcg/L) and 1.3 + 0.5mcg/L (standard <2mcg/L), respectively. One individual had a marginally increased blood chromium concentration of 1.3mcg/L. Evaluations considering ceramic or cobalt-chrome heads, up to a decade of follow up, or varying implant metrics showed negligible variations in metal ion concentrations. CONCLUSION: The findings reveal that over a minimum of five years (average = six years; span, five to 10 years), cobalt and chromium concentrations in patients' systems remained within normal limits and were clinically insignificant, irrespective of the follow-up duration, head material, or implant specifications. This underscores the efficacy of dual mobility systems in ensuring minimal metal ion presence.

4.
J Arthroplasty ; 2024 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-38403080

RESUMEN

BACKGROUND: Smartphone and wearable technologies offer innovative methods for monitoring postoperative recovery in total knee arthroplasty (TKA) patients. This review assessed the benefits of these technologies in postoperative care, focusing on (1) smartphone applications, (2) wearable devices, and (3) their combination. METHODS: A systematic search identified studies on smartphone applications and wearables for post-TKA monitoring. The review analyzed 2,119 studies, with 58 meeting criteria: 25 on applications, 25 on wearables, and 8 on both. Studies were rated with a methodology index as well as by levels of evidence. They were then analyzed by categorizing them by adherence and patient satisfaction, functional outcomes and pain scores, gait analyses and ranges of motion, and measurement and comparison tools. RESULTS: A review of 24 of 25 publications related to smartphone applications used for postoperative recovery in TKA showed the potential for improved patient's satisfaction, gait recovery, pain medication scheduling guidance with improved pain management, cost savings, and functional outcomes. Wearable technologies used in postoperative recovery demonstrated monitoring accuracy in 25 studies. These devices also showed effectiveness in gait and motion analysis. Other demonstrated benefits of the wearables were improved outcomes, return to function, cost reduction, and again, better management of pain due to patient interaction and guidance. Studies that combined applications and wearables demonstrated the individual findings with the addition of adherence, patient's satisfaction, and overall mobility improvement at 3 months. CONCLUSIONS: Smartphone applications and wearables can enhance postoperative rehabilitation for TKA patients. Smartphone applications and wearables have been shown in randomized trials to be accurate, effective, and useful in the postoperative rehabilitation of TKA patients. A recurring theme in the review was improved adherence to care plans and medication schedules that ultimately result in improved functional outcomes. These technologies and the data that they generate offer direct patient benefits and the potential for future cost savings.

5.
J Knee Surg ; 37(3): 238-247, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37084759

RESUMEN

Skin closure for total knee arthroplasty (TKA) typically focuses on promoting optimal healing, while preventing wound complications and infection, allowing for functionality and immediate ambulation, and providing for excellent cosmesis. In this systematic review and meta-analysis of the literature, we will focus on closure of the skin. Specifically, we assessed: (1) wound complication risk of different techniques and (2) closing time of different sutures/techniques. There were 20 reports on infection risk and closing time. Meta-analyses focused on the qualifying studies for closing time and wound complication risk reports were also performed. These studies (378 patients) demonstrated overall lower wound complication risks with the use of barbed compared with traditional sutures (3% vs. 6%, p < 0.05). The subsequent meta-analysis included 749 patients demonstrating overall significant closing time reductions of a mean of 7 minutes with the use of barbed sutures (p < 0.05). Therefore, multiple recent reports suggest superior outcomes and faster results when using barbed sutures for TKA skin closure.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Resultado del Tratamiento , Técnicas de Sutura , Cicatrización de Heridas , Suturas
6.
J Orthop ; 46: 78-82, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37969228

RESUMEN

Introduction: Several implant manufacturers have developed ultra-porous metal substrate acetabular components recently. Despite this, data on clinical and radiographic outcomes remain limited. Our study evaluated postoperative patient-reported outcome measures (PROMs) and radiographic analyses in patients fitted with a novel acetabular porous-coated component. Methods: A total of 152 consecutive patients underwent a total hip arthroplasty by a single orthopaedic surgeon. All patients underwent surgery utilizing the same CT-scan based robotic-assisted device with the same porous cementless acetabular shell. They received standardized postoperative physical therapy, rehabilitation, and pain protocols. Preoperatively, first postoperative visit, 6-months, 1-year, and 2-years, patients were evaluated based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain, physical function, and total scores; 2) Patient-Reported Outcomes Measurement Information System (PROMIS)-10 physical and mental scores; 3) Hip Disability and Osteoarthritis Outcome Score (HOOS)-Jr scores; as well as 4) acetabular component positions and 5) evidence of acetabular component loosening. Results: Significant improvements were observed by 6 months in WOMAC pain, physical function, and total scores (p < 0.05), maintained at 1 and 2 years. PROMIS-10 physical scores also improved significantly from preoperative to 6 months postoperative and remained so at 1 and 2 years postoperative (p < 0.05). No significant changes were found in PROMIS-10 mental scores. HOOS-Jr scores significantly improved from preoperative to 6 months postoperative and remained so through 2 years (p < 0.05). At 6 months, slight changes were noted in abduction angle and horizontal and vertical offset. Radiolucencies, initially found in 3 shells, reduced to 1 shell with 2 new radiolucencies by 6 months, and remained stable with no subsequent operative interventions. At 1 year and 2 years, no radiographic abnormalities were noted, including complete resolution of prior radiolucencies as well as stable components. Conclusion: This porous cementless acetabular shell, implanted with CT-scan-based robotic-assisted techniques, demonstrated excellent postoperative PROMs at 2 years. Stable radiolucencies suggest good component stability. The early stable clinical and radiographic results suggest promising long-term outcomes with this device. Level of evidence: III (retrospective cohort study).

7.
Surg Technol Int ; 432023 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-37781883

RESUMEN

BACKGROUND: Robotic-assisted total knee arthroplasty (TKA) has been associated with improved accuracy and precision of implant placement, protection of soft tissue, and improved patient-reported postoperative outcomes when compared to manual TKA techniques. Previous studies have highlighted the importance of surgical confidence throughout the learning curve when adopting robotic-assisted platforms. The purpose of this study was to evaluate the confidence and efficiencies of surgeons when utilizing computed tomography (CT)-based robotic TKA technology. MATERIALS AND METHODS: A cross-sectional, questionnaire-based study was conducted with 20 arthroplasty-trained surgeons with prior experience in both manual TKA and robotic-assisted TKA techniques. The surgeons completed an initial learning period, with new software, during various stages of their experience. The new TKA software upgrade builds on the prior software version with new features. A Net Promoter Score (NPS), the measurement of a respondent's likelihood to recommend a product or service to others, was used during the analysis of survey questions. A NPS over 50 indicates a positive score. RESULTS: When compared to manual TKA techniques, 95% of surgeons reported that their overall intraoperative confidence increased with the new software upgrade for CT-based robotic technology and had an average rating of 8.9 out of 10 for their intraoperative confidence with the new software upgrade. Additionally, 100% of surgeons reported that they were more confident when performing intraoperative implant adjustments with the new software upgrade when compared to manual TKA. Surgeons determined that the overall use of the new software upgrade was intuitive (8.4 of 10 average rating) and were satisfied with the overall use of the new software upgrade (9 of 10 average rating). Also, surgeons reported that they would recommend the new software upgrade for CT-based robotic technology to colleagues (NPS of 85), as well as being used as a research tool (NPS of 85) or for a training and education tool in a fellowship program (NPS of 90). CONCLUSION: As new technology continues to enter the field of orthopedics, it is important to ensure upgrades and advancements continue to serve surgeons and provide efficiencies in the operating room. For established robotic surgeons, the new robotic technology assessed in this study provided increased confidence when compared to manual TKA. Based on these results, the new software upgrade demonstrated value during various stages of a TKA procedure and is highly recommended for use by others in the field of orthopedics.

8.
Surg Technol Int ; 422023 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-37470176

RESUMEN

INTRODUCTION: Remote physiologic monitoring (RPM), or remote therapeutic monitoring (RTM), has grown exponentially for the management of chronic medical diseases in Medicare patients. More recently, the application of this technology has ventured into the orthopaedic arena, and more specifically, for total joint arthroplasty. Platforms to expedite this monitoring can provide continuous biodata feedback on digital biomarkers to patients and surgeons, which can potentially help improve and create novel patient-specific recovery pathways. Furthermore, various devices developed for this monitoring might help obviate the need for frequent emergency room visits, readmissions, and prolonged outpatient physical therapy sessions, as well as reduce complications and increase patient satisfaction scores after total joint arthroplasty surgery. However, while there are a number of potential benefits to technology for this type of care, its application following total knee arthroplasty has not been well-studied. Therefore, after an overview of the usage of RPM and RTM, the purpose of this study was to review the current literature regarding three common remote monitoring technologies: 1) smartphone apps; 2) wearables; and 3) combined smartphone apps and wearables. We also considered the potential financial implications of remote physiologic monitoring. MATERIALS AND METHODS: A comprehensive search of the PubMed, Cochrane Library, MedLine, and Web of Science databases was performed. Three main subgroups of monitoring devices were included for analysis: smartphone apps, wearable devices, and combined wearable plus smartphone app platforms. Searches focused on remote physiologic monitoring, patient-specific advantages, financial advantages, billing and coding options, as well as overall efficacy of platforms. RESULTS: The current review found smartphone apps, wearables, and combined smartphone app and wearable platform technologies to be advantageous in the postoperative period following total knee arthroplasty. The wearable components can provide highly accurate and reproducible data, which the user-friendly smartphone app can relay to the patient so they can easily understand their progress. Additionally, through the apps, patients can directly access their surgical team. By constantly collecting and evaluating range of motion and functional data, the surgical team can identify if the patient is appropriately progressing through treatment or if further intervention is warranted. CONCLUSION: The incorporation of the remote physiologic monitoring devices during the post-total knee arthroplasty period shows strong promise as a progress-tracking modality. Published benefits include reduced physical therapy visits, decreased pain scores and reliance on opioids, increased activity levels as assessed by step counts, increased ability to follow less well-performing patients, reduced readmissions, reduced in-person clinic visits, and decreased postoperative costs.

10.
Arthroplast Today ; 21: 101126, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37234598

RESUMEN

A 1.5-stage exchange total knee arthroplasty for periprosthetic joint infection has been described; however, achieving a balanced and well-aligned construct can sometimes be difficult given the bony defects often encountered in these cases. The use of robotic navigation technologies allows for accurate and precise implant placement. This technique report details the utilization of robotic navigation in a 1.5-stage exchange total knee arthroplasty for periprosthetic joint infection and describes the outcome of 6 patients. This technique guide highlights how robotic technology can account for many commonly encountered bone voids, joint line identification, and component orientation, while achieving a balanced and well-aligned knee.

11.
J Comp Eff Res ; : e220208, 2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37144744

RESUMEN

Aim: Determine the clinical utility and economic differences over a 90-day period between robotic arm-assisted total hip arthroplasty (RATHA) and manual total hip arthroplasty (MTHA). Methods: Leveraging a nationwide commercial payer database, pre-covid THA procedures were identified. Following a 1:5 propensity score match, 1732 RATHA and 8660 MTHA patients were analyzed. Index costs, index lengths of-stay, and 90-day episode-of-care utilization and costs were evaluated. Results: Episode of care costs for RATHA was found to be $1573 lower compared with MTHA (p < 0.0001). Post-index hospital utilization was significantly less likely to occur for RATHA compared with MTHA. Total index costs were also significantly lower for RATHA versus MTHA (p < 0.0001). Conclusion: Index and post-index EOC hospital utilization and costs were lower for RATHA compared with MTHA.

12.
J Arthroplasty ; 38(7): 1326-1329, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36878436

RESUMEN

BACKGROUND: The association between malnutrition and complications following primary total joint arthroplasty is well-delineated; however, nutritional status has yet to be explored specifically in revision total hip arthroplasty (THA). Therefore, our objective was to examine if a patient's nutritional status based on body mass index, diabetic status, and serum albumin predicted complications following a revision THA. METHODS: A retrospective national database review identified 12,249 patients who underwent revision THA from 2006 to 2019. Patients were stratified based on body mass index (<18.5 = underweight, 18.5-29.9 = healthy/overweight, ≥30 = obese), diagnosis of diabetes (no diabetes, insulin-dependent diabetes mellitus (IDDM), non-insulin-dependent diabetes mellitus), and preoperative serum albumin (<3.5 = malnourished, ≥3.5 = non-malnourished). Multivariate analyses were performed using chi-square tests and multiple logistic regressions. RESULTS: In all groups including underweight (1.8%), healthy/overweight (53.7%), and obese (44.5%), those without diabetes were less likely to be malnourished (P < .001), while those with IDDM had a higher rate of malnutrition (P < .001). Underweight patients were significantly more malnourished compared to healthy/overweight or obese patients (P < .05). Malnourished patients had an increased risk of wound dehiscence/surgical site infections (P < .001), urinary tract infection (P < .001), requiring a blood transfusion (P < .001), sepsis (P < .001), and septic shock (P < .001). Malnourished patients also have worse postoperative pulmonary and renal function. CONCLUSION: Patients who are underweight or have IDDM are more likely to be malnourished. The risk of complications within 30 days of surgery following revision THA significantly increases with malnutrition. This study shows the utility of screening underweight and IDDM patients for malnutrition prior to revision THA to minimize complications.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Diabetes Mellitus Tipo 1 , Desnutrición , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Estado Nutricional , Estudios Retrospectivos , Diabetes Mellitus Tipo 1/complicaciones , Sobrepeso/complicaciones , Delgadez/complicaciones , Delgadez/epidemiología , Factores de Riesgo , Obesidad/complicaciones , Desnutrición/complicaciones , Desnutrición/diagnóstico , Desnutrición/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Reoperación/efectos adversos
13.
Surg Technol Int ; 422023 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-36602172

RESUMEN

INTRODUCTION: As implant technology has continued to improve over the past decade, there has been an increase in the utilization of highly porous metal substrate acetabular components for primary total hip arthroplasty (THA). These implants have several theoretical benefits including a lower modulus of elasticity, which may result in a reduction in stress shielding, a higher coefficient of friction, which may enable better initial implant fixation, as well as higher porosity that may facilitate improved biological fixation. Although these components are implanted frequently, there are some studies that have posed concerns regarding radiographic evidence of loosening. Therefore, the purpose of this study was to assess: 1) The quality of fixation of porous metal acetabular components based on radiographs; 2) clinical outcomes; and 3) revision rates. MATERIALS AND METHODS: A total of 159 patients (169 hips) who had undergone a primary THA utilizing a porous metal primary acetabular cup with minimum two-year follow up were assessed. The study cohort consisted of 51% women, had a mean age of 65 years (range, 30 to 92 years), a mean body mass index (BMI) of 29kg/m2 (range, 15 to 54), and a mean follow up of approximately four years (range, three to six years). Acetabular revision for component failure was documented. Radiographic assessments were independently performed by two fellowship-trained arthroplasty surgeons to determine implant stability and radiolucencies. Clinical evaluations were made by assessing the hip disability and osteoarthritis outcome score (HOOS-Jr) survey scores. Failure was defined as the need to revise the acetabular component, for either septic or aseptic pathology. RESULTS: At final follow up, one patient had definitive loosening, one had probable loosening, and three patients had possible loosening. Only 3.0% had radiolucencies or radiosclerotic lesions in at least one zone. Of these patients, three developed progressive radiolucencies. All patients achieved excellent postoperative HOOS-Jr scores, and no significant differences were noted between patients who did not have loosening compared to patients who had possible or probable loosening. Only two patients underwent revision for aseptic loosening of the cup (success rate for this implant was 98.8% [2/169]). DISCUSSION: There is a paucity of studies focused on the results of this porous metal substrate acetabular component, with some of the current literature reporting conflicting outcomes. Our study reported a low acetabular revision rate of only 1.2% at an approximate mean follow up of four years. The incidence of radiolucencies and progressive radiolucencies were lower (3.0%) than has been found in some studies. Overall, the results of this study support the utilization of this acetabular component in appropriately indicated patients. CONCLUSION: These data show a low rate of acetabular revision at mean four-year follow up.

15.
J Knee Surg ; 36(3): 269-273, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34261159

RESUMEN

The aim of this study was to track the annual rates and trends of overall, deep, and superficial surgical site infections (SSIs) following total knee arthroplasty using the most recent results from a large and nationwide database. A total of 197,192 cases were performed between 2012 and 2016 from a nationwide database stratified into years and based on superficial and/or deep SSIs. Cohorts were analyzed individually and then combined to evaluate overall SSI rates. The infection incidence for each year was calculated. After a 6-year correlation and trends analysis, univariate analyses were performed to compare the most recent year, 2016, with each of the preceding 4 years. Overall, there was a downward trend in overall SSI rates over the study period (2012-2016, with the lowest rate occurring in the most recent year, 2016 [0.11%]). Additionally, there was a decreasing trend for superficial SSI, with the lowest superficial SSI incidence occurring in 2016 (0.47%) and the greatest incidence occurring in 2012 (0.53%). An overall trend of decreasing SSI rates was observed nationwide over the 5-year period evaluated. A similar decreasing trend was also noted specifically for deep SSI rates, which can be potentially more complicated to manage, and result in decreased implant survivorship. The down trending SSI rates observed give potential credence to the value for newer and developing SSI preventative therapies as well as improved medical and surgical patient management. Nevertheless, there is still room for improvement, and continued efforts are needed to further lower SSIs after total knee arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Infección de la Herida Quirúrgica/epidemiología , Infección de la Herida Quirúrgica/etiología , Incidencia , Bases de Datos Factuales , Estudios Retrospectivos
16.
J Knee Surg ; 35(14): 1524-1532, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36538940

RESUMEN

Dressings for total knee arthroplasty (TKA) typically focus on promoting optimal healing, while preventing infection, allowing for functionality and immediate ambulation, while providing for excellent cosmesis. We have previously described four aspects of closure after TKA involving the: (1) deep fascial layer; (2) subdermal layer; (3) intradermal layer, including the subcuticular region; and (4) a specific aseptic dressing. In this meta-analysis and systematic review of the literature, we will focus on the dressing. Specifically, we assessed: (1) infection risk of different techniques; (2) re-operation or readmission risk; and (3) length of time until dressing change needed. There were 16 reports on infection risk, re-operation risk, and length of time until change needed. A meta-analysis focused on the qualifying wound complication risk reports was also performed. The meta-analysis including four studies (732 patients) demonstrated overall lower wound complication risk with the use of adhesives and mesh dressings (odds ratio 0.67) versus traditional closures. Additionally, studies demonstrated fewer re-operations and readmissions with the use of adhesives and mesh dressings. Furthermore, one report demonstrated mesh dressings persist longer than silver dressings. Therefore, multiple recent reports suggest superior outcomes when using adhesive and mesh dressings for TKAs.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Vendajes , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/prevención & control , Reoperación , Cicatrización de Heridas
17.
J Craniovertebr Junction Spine ; 13(3): 331-338, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36263340

RESUMEN

Introduction: Compared to anterior cervical discectomy and fusion (ACDF), the motion preservation of cervical disc arthroplasty (CDA) provides an attractive alternative with similar short-term results. However, there is a paucity of the economics of performing CDA over ACDF. Study Design: This was retrospective study. Objective: The objective of this study is to evaluate relative-value-units (RVUs), operative time, and RVUs-per-minute between single-level ACDF and CDA. Secondary outcomes included 30-day readmission, reoperation, and morbidity. Methods: Adults who underwent ACDF or CDA in 2011-2019 National Surgical Quality Improvement Program database datasets. Multivariate quantile regression was utilized. Results: There were 26,595 patients (2024 CDA). ACDF patients were older, more likely to be female, discharged to inpatient rehabilitation, and have a history of obesity, smoking, diabetes, steroid use, and the American Society of Anesthesiologists-class ≥3. ACDF had greater median RVUs-per-case (41.2 vs. 24.1) and RVUs-per-minute (0.36 vs. 0.27), despite greater operative-time (109 min vs. 92 min) (P < 0.001). ACDF predicted a 16.9 unit increase in median RVUs per case (P < 0.001, confidence interval [CI]95: 16.3-17.5), an 8.81 min increase in median operative time per case (P < 0.001, CI95: 5.69-11.9), and 0.119 unit increase in median RVUs-per-minute (P < 0.001, CI95: 0.108-0.130). ACDF was associated with greater unadjusted rates of readmission (3.2% vs. 1.4%) morbidity (2.3% vs. 1.1%) (P < 0.001), but similar rates of reoperation (1.3% vs. 0.8%, P = 0.080). After adjusting for significant patient-related and procedural factors, readmission (odds ratio [OR] = 0.695, P = 0.130, CI95: 0.434-1.113) and morbidity (OR = 1.102, P = 0.688, CI95: 0.685-1.773) was similar between ACDF and CDA. Conclusions: Median RVUs-per-minute increased by 0.119 points for ACDF over CDA, or $257.7/h for each additional-hour of surgery. Adjusted 30-day outcomes were similar between procedures. Reimbursement for CDA does not appear to be in line with ACDF and may be a barrier to widespread usage.

18.
Surg Technol Int ; 412022 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-36041076

RESUMEN

INTRODUCTION: Total hip arthroplasty (THA) aims to restore function and reduce pain for patients suffering from hip pathologies. However, some procedures require revision THA, with the most common reasons including: mechanical failure, aseptic loosening, infection, and component malposition leading to dislocations. Computed tomography (CT) scan-based, three-dimensional imaging operating techniques can help address some of these issues by helping to provide more optimal implant positioning, which can potentially confer improved outcomes. To date, only a few studies have evaluated the utilization of CT scan-based robotic-arm assisted THA in total hip arthroplasty, and those that do are not necessarily of the high-methodological quality. Therefore, the purpose of this review was to select the most recent and good- to high-quality studies focusing on robotic-assisted THA, to help provide a more comprehensive representation of postoperative outcomes. Specifically, we evaluated each study independently as well as performed a cumulative assessment of this most recent high-quality data. MATERIALS AND METHODS: An extensive, cross-platform search of total hip arthroplasty on August 1, 2022 was performed. Studies were included only if they addressed robotic-assisted THA in comparison to manual techniques. Additional inclusion criteria consisted of studies scoring excellent (100 to 85 points) or good (84 to 70 points) based on their Coleman methodology score. Studies were evaluated as individual pieces of work, as well as a cumulative assessment. Specific outcomes evaluated were: component placement in safe zones, leg- length discrepancies, dislocation rates, clinical outcomes, patient clinical scores, patient-reported outcome measures (PROMS), lengths of stay, and costs. RESULTS: Overall, 24 studies were included for analyses. CT scan-based robotic-arm assisted THA had some potential key advantages as compared to manual techniques. Specifically, robotic-assisted THA was associated with more accurate component placement in safe zones, fewer chances of leg-length discrepancies, and lower risks of dislocation. Patient satisfaction and reported outcome measures were superior for CT scan-based robotic-arm assisted THA. Costs were also lower. Overall, 23 of 24 studies were positive for this technology, with one study of cases done between 2010 and 2014 more neutral. The robot led to positive findings for component placement in safe zones, leg-length discrepancies, dislocation rates, clinical outcomes, PROMS, lengths of stay, and costs. CONCLUSION: The current literature suggests potential advantages for CT scan-based robotic-arm assisted THA compared to manual THA. Surgeons should consider CT scan-based robotic-arm assisted THA for their patients given the multiple added benefits of improved clinical scores and PROMS, less dislocations (with a few exceptions reported), more component placements in safe zones, less leg-length discrepancies, decreased lengths of stay, and decreased episode-of-care costs.

19.
Surg Technol Int ; 412022 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-35801355

RESUMEN

Wound closure for total knee arthroplasty (TKA) typically focuses on promoting the most optimal healing, while preventing infection, allowing for functionality and immediate ambulation, as well as providing for excellent cosmesis. We have previously described four aspects of closure for TKA including the: (1) deep fascial layer; (2) subdermal layer; (3) intradermal layer, including the subcuticular region; and (4) a specific dressing. In this systematic review and meta-analysis of the literature, we will focus on closure of the deep fascial layer. Specifically, we assessed: (1) wound complication risks of different techniques; (2) closing times of different sutures; and (3) postoperative ranges of motion depending on varying levels of knee flexion or extension. There were 12 reports on wound complication risks, closing times, and positionings. The meta-analysis demonstrated overall lower wound complication risks with the use of barbed sutures (6 versus 13%, p<0.05). It also demonstrated overall significant closing time reductions with the use of barbed sutures (p<0.05). Additionally, three out of four reports showed the positive effects of closure in flexion for TKAs, while one report was inconclusive. In conclusion, this systematic review and meta-analysis demonstrated lower wound complications, decreased closing times for barbed sutures, as well as superior outcomes for closures in a semi-flexed knee position.

20.
Surg Technol Int ; 412022 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-35801356

RESUMEN

INTRODUCTION: One of the main concerns with total hip arthroplasty is the development of periprosthetic joint infections (PJIs). Appropriate wound closure can contribute to the prevention of PJIs with a watertight closure effectively sealing the implant from the outside. It is important to continuously investigate which materials as well as techniques are potentially the most efficacious and cost effective for wound closure. Therefore, the purpose of this review article was to critically appraise the current total hip arthroplasty wound closure materials and techniques as reported in the literature. Specifically, we evaluated: 1) fascial approximations; 2) subdermal closures; 3) subcuticular and skin closures; 4) wound dressings; as well as 5) capsular and short external rotator repairs. MATERIALS AND METHODS: A literature search was performed using the PubMed database from inception to February 2022. The query consisted of terms including "hip, arthroplasty, wound, closure, capsular closure, fascial closure, subcutaneous closure, and skin closure." References from selected texts were also reviewed for inclusion. Only manuscripts written in the English language were included for final analysis. A systematic review was performed for the five topics: 1) fascial approximations; 2) subdermal closures; 3) subcuticular and skin closures; 4) wound dressings; as well as 5) capsular and short external rotator repairs. Additionally, a meta-analysis was performed on the closing time of fascial approximations. RESULTS: The current literature supports performing a layered closure of the wound by approximating the fascial layers, which can help close any empty spaces. The techniques for closure at this layer seem to be equal regarding wound complications between running knotless barbed sutures versus interrupted throws; however, knotless sutures have the potential of a quicker closure time. A total of three out of four reports and the meta-analyses demonstrated that wound closure time can be reduced with barbed sutures, along with decreased number of sutures required as also shown by three out of four reports. The most superficial layers, subcuticular and skin, can be closed with either sutures, staples, or skin adhesives, all of which appear to have adequate outcomes. A report found that patients who had skin closure with barbed suture had faster time to a dry postoperative wound and lower rates of delayed discharge. For the overlying dressing, an occlusive and absorbent dressing can both protect the wound as well as collect any residual wound drainage. Two reports found increased dryness, decreased wound drainage, and decreased rates of delayed wound healing with use of 2-octyl cyanoacrylate topical adhesive with flexible self-adhesive polyester mesh dressings. If the capsule and short external rotators are taken down during the approach, repairing these can potentially help increase postoperative hip stability as well as decrease dislocation rates. CONCLUSION: The variety of materials and techniques available to close a THA wound allows surgeons to tailor closure to be patient specific. In general, the authors recommend performing layered closures from the capsule and short external rotators (if taken down during the approach), fascial layer closure with either a running knotless suture, subcutaneous closure either with the same knotless suture as the fascial layer brought more superficially, or with simple interrupted sutures to tack down any empty space, as well as finally subcuticular and skin sutures with a skin adhesive glue overtop. The skin adhesive can help provide an extra layer, particularly in active patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...