Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Oral Maxillofac Surg ; 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38315402

RESUMEN

PURPOSE: The aim of this retrospective study was to evaluate the outcomes of a two-piece implant system with a tube-in-tube internal connection after up to 15 years of clinical use. MATERIAL AND METHODS: A retrospective follow-up examination of patients treated with internal tube-in-tube implants between 2003 and 2006 was conducted. The implant survival rates, peri-implant conditions (marginal bone loss, bleeding on probing, plaque index, probing depth), and technical complications were determined. RESULTS: In total, 312 dental implants were placed in 152 patients. Of the original 152 patients enrolled, 245 implants in 112 patients were available for a follow-up evaluation after 11 to 15 years (mean observation time, 12.9 ± 1.1 years). The overall implant survival rate was 93.9%. Outcomes for MBL (1.49 ± 1.23 mm), PI (24.3 ± 22.2%), BOP (18.3 ± 28.7%), and PD (2.74 ± 1.21 mm) were observed. Selected parameters (time after implant surgery, smoking habits, bone augmentation (GBR)) showed an influence on MBL and PD. CONCLUSIONS: The internal tube-in-tube implant system showed favorable long-term results. The correlation of MBL and PD with the patient-specific factor smoking habit is in accordance with other studies. CLINICAL RELEVANCE: Camlog Root-Line implants with a tube-in-tube implant-abutment connection and a 1.6-mm polished neck configuration have demonstrated favorable long-term outcomes in daily clinical practice. However, it is important to note that these implants are no longer available on the market.

2.
J Prosthet Dent ; 131(4): 707.e1-707.e8, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38331670

RESUMEN

STATEMENT OF PROBLEM: Three-dimensional (3D) printing technology has gained popularity in producing removable partial denture (RPD) frameworks, including direct 3D printing of the metal framework and framework printing using castable resin, subsequently cast and processed. However, whether the technology is sufficiently accurate and precise to supersede traditional methods is unclear. PURPOSE: The purpose of this in vitro study was to determine the accuracy and precision of 2 different methods in the fabrication of RPD frameworks, including 3D printing by selective laser melting (SLM) and digital light processing (DLP). MATERIAL AND METHODS: Maxillary casts were digitized to design RPD frameworks. Thereby, 8 frameworks were produced for each group. The SLM group underwent a thermal finishing process after printing. In the DLP group, castable resin was printed but not cast. All frameworks were scanned to generate digital files, which were then compared with the original design using a metrology software program and manual measurements. Statistical analysis was executed using the t-test for independent specimens (α=.05) and by comparing heatmaps of the overlaid meshes. RESULTS: The analysis of the frameworks indicated minor deviations across all specimens. Regarding accuracy, there were no significant differences between the groups (P=.986). The SLM frameworks demonstrated greater precision, with absolute deviation values of 0.13 mm compared with 0.17 mm in the DLP group (P<.001). CONCLUSIONS: The findings underscored a high consistency between the 2 printing techniques, demonstrating a sufficiently advanced production process to yield predictable results. While the accuracy of both techniques was at a comparably high level and did not differ significantly, the SLM technique delivered RPDs with higher precision.


Asunto(s)
Diseño Asistido por Computadora , Dentadura Parcial Removible , Impresión Tridimensional , Rayos Láser , Maxilar
3.
Clin Oral Implants Res ; 35(2): 155-166, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37987199

RESUMEN

OBJECTIVES: To assess in a prospective randomized trial two phycogenic bone substitutes-biphasic calcium phosphate (BCP) versus almost pure hydroxyapatite (HA)-for their volume stability and clinical implications after sinus floor elevation (SFE). MATERIALS AND METHODS: Twenty patients requiring lateral-window SFE 6 months prior to implant surgery were randomized to a BCP or HA group. As primary outcome, the grafts were analyzed for volume stability, using four cone-beam computed tomography scans obtained immediately/6/12/24 months after SFE. Secondary outcomes were implant survivval, success, periotest values, oral-health-related quality of life (OHIP-G14), and pain (VAS). RESULTS: Kolmogorov-Smirnov goodness-of-fit test revealed normal distribution of samples (p = .200). At 6/12/24 months, the augmented volumes decreased to 96/92/90% (HA) or 99/96/96% (BCP). Volume changes were significantly a factor of time (p < .001; generalized linear model with repeated measures) and reached significantly lower values in HA group (p = .018). Significant intergroup difference in volume losses was notable at 24 months (p = .021; t-test for independent samples). Periotest values decreased from -3/-4.1 (HA/BCP) after implant placement to -6.3/-4.5 (HA/BCP) after 6 months. OHIP scores diverged at 2 months (HA: 9.5; BCP: 5.2) and largely resolved by 24 months (HA: 1.3; BCP: 1.9). VAS scores were comparable, 2.2 at 1 week after SFE being their highest mean level. CONCLUSIONS: After 2 years, both groups experienced no biological or technical complications, demonstrating a consistent healing trajectory without notable symptoms. Although no significant differences were observed in implant stability and survival, BCP demonstrated higher volume stability than HA.


Asunto(s)
Sustitutos de Huesos , Elevación del Piso del Seno Maxilar , Humanos , Durapatita/uso terapéutico , Elevación del Piso del Seno Maxilar/métodos , Estudios Prospectivos , Calidad de Vida , Hidroxiapatitas/uso terapéutico , Sustitutos de Huesos/uso terapéutico , Seno Maxilar/cirugía
4.
Int J Oral Implantol (Berl) ; 13(4): 387-399, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33491369

RESUMEN

Aims: While numerous materials are available for sinus floor elevation, plant-based alternatives still hold promise of overcoming concerns about allogeneic or xenogeneic materials. Thus, the present authors designed a randomised clinical trial to histologically compare an almost pure hydroxyapatite (HA) to a biphasic calcium phosphate comprising 80% ß-tricalcium phosphate (ß-TCP) and 20% hydroxyapatite (ß-TCP/HA), all of phycogenic origin. Materials and methods: Twenty patients scheduled for lateral window sinus floor elevation were randomised to either an HA or a ß-TCP/HA group. Biopsy specimens were taken 3 months after sinus floor elevation and during implant surgery after 6 months. One ground section per biopsy specimen (N = 40) was stained, scanned and histomorphometrically analysed for new bone, old bone, soft tissue, graft, bone infiltration of graft, bone-to-graft contact and penetration depth. Results: At 6 months, more new bone was seen in the ß-TCP/HA group (P = 0.011), whereas more residual graft was present and in more extensive contact with new bone in the HA group. More pronounced alterations, and smaller particle sizes, of graft surrounded and infiltrated by bone were seen in the ß-TCP/HA group. The less extensive bone-to-graft contact in the ß-TCP/ HA group reflected a more advanced state of resorption, while infiltration of residual graft material by bone was also increased in this group. Conclusions: Proper healing was seen in both groups, with the graft materials guiding the formation of new bone, which grew especially well through the particles of the highly osteoconductive and resorptive ß-TCP/HA material. HA was very stable, without significant resorption, but was extensively in contact with new bone after 6 months.


Asunto(s)
Sustitutos de Huesos , Elevación del Piso del Seno Maxilar , Sustitutos de Huesos/uso terapéutico , Durapatita , Humanos , Hidroxiapatitas/uso terapéutico , Proyectos Piloto
5.
Int J Comput Dent ; 22(4): 321-329, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31840140

RESUMEN

AIM: The production of individual tooth replicas has two applications in dental practice: tooth autotransplantations and dental root analogue implants. These applications require a particularly high degree of precision. The purpose of this study was to establish and evaluate a method for fabricating individual 3D-printed tooth replicas. MATERIALS AND METHODS: 10 patients requiring extraction of a wisdom tooth and a preoperative cone beam computed tomography (CBCT) scan were included; exclusion criteria were intraoperative fragmentation or fracture of the tooth. 3D Slicer 4.6.2 was used for tooth segmentation and model generation based on CBCT data. The tooth replicas were manufactured by selective laser melting (SLM). The extracted teeth and 3D-printed replicas were scanned and tested for surface deviations in CloudCompare 2.8.1. RESULTS: The mean absolute surface deviation between the 3D-printed teeth and the corresponding extracted teeth ranged from 0.13 to 0.25 mm, with standard deviations of 0.10 to 0.21 mm; 95% of the measured surface points deviated less than 0.474 mm; the surface area was reduced by -6.0% and the volume by -3.4%. The root mean square was 0.238 mm and the mean maximum absolute surface deviation was 0.927 mm. The SLM technique showed a high precision with a mean absolute deviation of 0.045 mm and a standard deviation of 0.04 mm. CONCLUSION: 3D-printed tooth replicas with a very high accuracy could be produced based on CBCT data. The described method is suitable for manufacturing tooth replicas for use in tooth autotransplantations or for fabricating root analogue implants.


Asunto(s)
Implantes Dentales , Diente , Tomografía Computarizada de Haz Cónico , Humanos , Impresión Tridimensional , Raíz del Diente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA