Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(10)2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38794022

RESUMEN

The widely adopted paradigm in brain-computer interfaces (BCIs) involves motor imagery (MI), enabling improved communication between humans and machines. EEG signals derived from MI present several challenges due to their inherent characteristics, which lead to a complex process of classifying and finding the potential tasks of a specific participant. Another issue is that BCI systems can result in noisy data and redundant channels, which in turn can lead to increased equipment and computational costs. To address these problems, the optimal channel selection of a multiclass MI classification based on a Fusion convolutional neural network with Attention blocks (FCNNA) is proposed. In this study, we developed a CNN model consisting of layers of convolutional blocks with multiple spatial and temporal filters. These filters are designed specifically to capture the distribution and relationships of signal features across different electrode locations, as well as to analyze the evolution of these features over time. Following these layers, a Convolutional Block Attention Module (CBAM) is used to, further, enhance EEG signal feature extraction. In the process of channel selection, the genetic algorithm is used to select the optimal set of channels using a new technique to deliver fixed as well as variable channels for all participants. The proposed methodology is validated showing 6.41% improvement in multiclass classification compared to most baseline models. Notably, we achieved the highest results of 93.09% for binary classes involving left-hand and right-hand movements. In addition, the cross-subject strategy for multiclass classification yielded an impressive accuracy of 68.87%. Following channel selection, multiclass classification accuracy was enhanced, reaching 84.53%. Overall, our experiments illustrated the efficiency of the proposed EEG MI model in both channel selection and classification, showing superior results with either a full channel set or a reduced number of channels.


Asunto(s)
Algoritmos , Interfaces Cerebro-Computador , Electroencefalografía , Redes Neurales de la Computación , Humanos , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Imaginación/fisiología , Atención/fisiología
2.
Sensors (Basel) ; 23(18)2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37765980

RESUMEN

Scoring polysomnography for obstructive sleep apnea diagnosis is a laborious, long, and costly process. Machine learning approaches, such as deep neural networks, can reduce scoring time and costs. However, most methods require prior filtering and preprocessing of the raw signal. Our work presents a novel method for diagnosing obstructive sleep apnea using a transformer neural network with learnable positional encoding, which outperforms existing state-of-the-art solutions. This approach has the potential to improve the diagnostic performance of oximetry for obstructive sleep apnea and reduce the time and costs associated with traditional polysomnography. Contrary to existing approaches, our approach performs annotations at one-second granularity. Allowing physicians to interpret the model's outcome. In addition, we tested different positional encoding designs as the first layer of the model, and the best results were achieved using a learnable positional encoding based on an autoencoder with structural novelty. In addition, we tried different temporal resolutions with various granularity levels from 1 to 360 s. All experiments were carried out on an independent test set from the public OSASUD dataset and showed that our approach outperforms current state-of-the-art solutions with a satisfactory AUC of 0.89, accuracy of 0.80, and F1-score of 0.79.


Asunto(s)
Trabajo de Parto , Apnea Obstructiva del Sueño , Embarazo , Femenino , Humanos , Oximetría , Suministros de Energía Eléctrica , Redes Neurales de la Computación , Apnea Obstructiva del Sueño/diagnóstico
3.
Sensors (Basel) ; 23(4)2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36850829

RESUMEN

The deployment of wearable wireless systems that collect physiological indicators to aid in diagnosing neurological disorders represents a potential solution for the new generation of e-health systems. Electroencephalography (EEG), a recording of the brain's electrical activity, is a promising physiological test for the diagnosis of autism spectrum disorders. It can identify the abnormalities of the neural system that are associated with autism spectrum disorders. However, streaming EEG samples remotely for classification can reduce the wireless sensor's lifespan and creates doubt regarding the application's feasibility. Therefore, decreasing data transmission may conserve sensor energy and extend the lifespan of wireless sensor networks. This paper suggests the development of a sensor-based scheme for early age autism detection. The proposed scheme implements an energy-efficient method for signal transformation allowing relevant feature extraction for accurate classification using machine learning algorithms. The experimental results indicate an accuracy of 96%, a sensitivity of 100%, and around 95% of F1 score for all used machine learning models. The results also show that our scheme energy consumption is 97% lower than streaming the raw EEG samples.


Asunto(s)
Trastorno del Espectro Autista , Trastorno Autístico , Dispositivos Electrónicos Vestibles , Humanos , Trastorno del Espectro Autista/diagnóstico , Algoritmos , Electroencefalografía
4.
Bioengineering (Basel) ; 9(9)2022 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-36135025

RESUMEN

Atrial fibrillation (AF) is one of the most common cardiac arrhythmias, and it is an indication of high-risk factors for stroke, myocardial ischemia, and other malignant cardiovascular diseases. Most of the existing AF detection methods typically convert one-dimensional time-series electrocardiogram (ECG) signals into two-dimensional representations to train a deep and complex AF detection system, which results in heavy training computation and high implementation costs. In this paper, a multiscale signal encoding scheme is proposed to improve feature representation and detection performance without the need for using any transformation or handcrafted feature engineering techniques. The proposed scheme uses different kernel sizes to produce the encoded signal by using multiple streams that are passed into a one-dimensional sequence of blocks of a residual convolutional neural network (ResNet) to extract representative features from the input ECG signal. This also allows networks to grow in breadth rather than in depth, thus reducing the computing time by using the parallel processing capability of deep learning networks. We investigated the effects of the use of a different number of streams with different kernel sizes on the performance. Experiments were carried out for a performance evaluation using the publicly available PhysioNet CinC Challenge 2017 dataset. The proposed multiscale encoding scheme outperformed existing deep learning-based methods with an average F1 score of 98.54%, but with a lower network complexity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...