Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 87(11): 11E324, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910323

RESUMEN

Three extreme ultraviolet (EUV) spectrometers have been mounted on the National Spherical Torus Experiment-Upgrade (NSTX-U). All three are flat-field grazing-incidence spectrometers and are dubbed X-ray and Extreme Ultraviolet Spectrometer (XEUS, 8-70 Å), Long-Wavelength Extreme Ultraviolet Spectrometer (LoWEUS, 190-440 Å), and Metal Monitor and Lithium Spectrometer Assembly (MonaLisa, 50-220 Å). XEUS and LoWEUS were previously implemented on NSTX to monitor impurities from low- to high-Z sources and to study impurity transport while MonaLisa is new and provides the system increased spectral coverage. The spectrometers will also be a critical diagnostic on the planned laser blow-off system for NSTX-U, which will be used for impurity edge and core ion transport studies, edge-transport code development, and benchmarking atomic physics codes.

2.
Rev Sci Instrum ; 87(11): 11D445, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910357

RESUMEN

A comprehensive set of spectroscopic diagnostics is planned in the National Spherical Torus Experiment Upgrade to connect measurements of molybdenum and tungsten divertor sources to scrape-off layer (SOL) and core impurity transport, supporting the installation of high-Z plasma facing components which is scheduled to begin with a row of molybdenum tiles. Imaging with narrow-bandpass interference filters and high-resolution spectroscopy will be coupled to estimate divertor impurity influxes. Vacuum ultraviolet and extreme ultraviolet spectrometers will allow connecting high-Z sources to SOL transport and core impurity content. The high-Z diagnostics suite complements the existing measurements for low-Z impurities (carbon and lithium), critical for the characterization of sputtering of high-Z materials.

3.
Rev Sci Instrum ; 87(11): 11D605, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910392

RESUMEN

A radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature Te estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPherson Model 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the Δn = 0, 1 line intensity ratios of carbon, nitrogen, or neon ion lines in the spectral range 300-1600 Å. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time Te-dependent signal within a characteristic divertor detachment equilibration time of ∼10-15 ms is expected.

4.
Rev Sci Instrum ; 87(11): 11E529, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910409

RESUMEN

Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D2 molecules and the He ash which will be produced by deuterium-tritium fusion. To study He exhaust, an in situ Penning gauge system is being developed at UW-Madison that is optimized for good pressure and high spectroscopic sensitivity. Three different anode geometries have been studied regarding their vacuum electrostatic fields, light output, and ion current. The light output of the two new anode configurations are at least one order of magnitude above the currently available designs, hence improving the spectroscopic sensitivity at similar total neutral pressure resolution.

5.
Rev Sci Instrum ; 86(12): 123103, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26724002

RESUMEN

A two-channel spectral imaging system based on a charge injection device radiation-hardened intensified camera was built for studies of plasma-surface interactions on divertor plasma facing components in the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak. By means of commercially available mechanically referenced optical components, the two-wavelength setup images the light from the plasma, relayed by a fiber optic bundle, at two different wavelengths side-by-side on the same detector. Remotely controlled filter wheels are used for narrow bandpass and neutral density filters on each optical path allowing for simultaneous imaging of emission at wavelengths differing in brightness up to 3 orders of magnitude. Applications on NSTX-U will include the measurement of impurity influxes in the lower divertor strike point region and the imaging of plasma-material interaction on the head of the surface analysis probe MAPP (Material Analysis and Particle Probe). The diagnostic setup and initial results from its application on the lithium tokamak experiment are presented.

6.
Rev Sci Instrum ; 85(11): 11E418, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430325

RESUMEN

New near infrared (NIR) spectroscopic measurements performed in the DIII-D tokamak divertor plasma suggest new viable diagnostic applications: divertor recycling and low-Z impurity flux measurements, a spectral survey for divertor Thomson scattering (DTS) diagnostic, and Te monitoring for divertor detachment control. A commercial 0.3 m spectrometer coupled to an imaging lens via optical fiber and a InGaAs 1024 pixel array detector enabled deuterium and impurity emission measurements in the range 800-2300 nm. The first full NIR survey identified D, He, B, Li, C, N, O, Ne lines and provided plasma Te, ne estimates from deuterium Paschen and Brackett series intensity and Stark line broadening analysis. The range 1.000-1.060 mm was surveyed in high-density and neon seeded divertor plasmas for spectral background emission studies for λ = 1.064 µm laser-based DTS development. The ratio of adjacent deuterium Paschen-α and Brackett Br9 lines in recombining divertor plasmas is studied for divertor Te monitoring aimed at divertor detachment real-time feedback control.

7.
Rev Sci Instrum ; 85(11): 11E825, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430390

RESUMEN

A conceptual design for a divertor Thomson scattering (DTS) diagnostic has been developed for the NSTX-U device to operate in parallel with the existing multipoint Thomson scattering system. Higher projected peak heat flux in NSTX-U will necessitate application of advanced magnetics geometries and divertor detachment. Interpretation and modeling of these divertor scenarios will depend heavily on local measurement of electron temperature, Te, and density, ne, which DTS provides in a passive manner. The DTS design for NSTX-U adopts major elements from the successful DIII-D DTS system including 7-channel polychromators measuring Te to 0.5 eV. If implemented on NSTX-U, the divertor TS system would provide an invaluable diagnostic for the boundary program to characterize the edge plasma.

8.
Rev Sci Instrum ; 83(10): 10D716, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126890

RESUMEN

A radiative divertor technique is used in present tokamak experiments and planned for ITER to mitigate high heat loads on divertor plasma-facing components (PFCs) to prevent excessive material erosion and thermal damage. In NSTX, a large spherical tokamak with lithium-coated graphite PFCs and high divertor heat flux (q(peak) ≤ 15 MW/m(2)), radiative divertor experiments have demonstrated a significant reduction of divertor peak heat flux simultaneously with good core H-mode confinement using pre-programmed D(2) or CD(4) gas injections. In this work diagnostic options for a new real-time feedback control system for active radiative divertor detachment control in NSTX-U, where steady-state peak divertor heat fluxes are projected to reach 20-30 MW/m(2), are discussed. Based on the NSTX divertor detachment measurements and analysis, the control diagnostic signals available for NSTX-U include divertor radiated power, neutral pressure, spectroscopic deuterium recombination signatures, infrared thermography of PFC surfaces, and thermoelectric scrape-off layer current. In addition, spectroscopic "security" monitoring of possible confinement or pedestal degradation is recommended. These signals would be implemented in a digital plasma control system to manage the divertor detachment process via an actuator (impurity gas seeding rate).

9.
Rev Sci Instrum ; 83(10): 10E532, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23127038

RESUMEN

A pair of two dimensional fast cameras with a wide angle view (allowing a full radial and toroidal coverage of the lower divertor) was installed in the National Spherical Torus Experiment in order to monitor non-axisymmetric effects. A custom polar remapping procedure and an absolute photometric calibration enabled the easier visualization and quantitative analysis of non-axisymmetric plasma material interaction (e.g., strike point splitting due to application of 3D fields and effects of toroidally asymmetric plasma facing components).

10.
Phys Rev Lett ; 107(14): 145004, 2011 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-22107204

RESUMEN

Lithium wall coatings have been shown to reduce recycling, improve energy confinement, and suppress edge localized modes in the National Spherical Torus Experiment. Here, we show that these effects depend continuously on the amount of predischarge lithium evaporation. We observed a nearly monotonic reduction in recycling, decrease in electron transport, and modification of the edge profiles and stability with increasing lithium. These correlations challenge basic expectations, given that even the smallest coatings exceeded that needed for a nominal thickness of the order of the implantation range.

11.
Rev Sci Instrum ; 81(10): 10D723, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033916

RESUMEN

The use of lithium-coated plasma facing components for plasma density control is studied in the National Spherical Torus Experiment (NSTX). A recently installed liquid lithium divertor (LLD) module has a porous molybdenum surface, separated by a stainless steel liner from a heated copper substrate. Lithium is deposited on the LLD from two evaporators. Two new spectroscopic diagnostics are installed to study the plasma surface interactions on the LLD: (1) A 20-element absolute extreme ultraviolet (AXUV) diode array with a 6 nm bandpass filter centered at 121.6 nm (the Lyman-α transition) for spatially resolved divertor recycling rate measurements in the highly reflective LLD environment, and (2) an ultraviolet-visible-near infrared R=0.67 m imaging Czerny-Turner spectrometer for spatially resolved divertor D I, Li I-II, C I-IV, Mo I, D(2), LiD, CD emission and ion temperature on and around the LLD module. The use of photometrically calibrated measurements together with atomic physics factors enables studies of recycling and impurity particle fluxes as functions of LLD temperature, ion flux, and divertor geometry.

12.
Phys Rev Lett ; 104(9): 095003, 2010 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-20366991

RESUMEN

Transient coaxial helicity injection (CHI) started discharges in the National Spherical Torus Experiment (NSTX) have attained peak currents up to 300 kA and when coupled to induction, it has produced up to 200 kA additional current over inductive-only operation. CHI in NSTX has shown to be energetically quite efficient, producing a plasma current of about 10 A/J of capacitor bank energy. In addition, for the first time, the CHI-produced toroidal current that couples to induction continues to increase with the energy supplied by the CHI power supply at otherwise similar values of the injector flux, indicating the potential for substantial current generation capability by CHI in NSTX and in future toroidal devices.

13.
Rev Sci Instrum ; 79(10): 10F539, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044681

RESUMEN

Ultraviolet and visible (UV-VIS, 200-750 nm) atomic spectroscopy of neutral and ionized fuel species (H, D, T, and Li) and impurities (e.g., He, Be, C, and W) is a key element of plasma control and diagnosis on International Thermonuclear Experimental Reactor and future magnetically confined burning plasma experiments (BPXs). Spectroscopic diagnostic implementation and performance issues that arise in the BPX harsh nuclear environment in the UV-VIS range, e.g., degradation of first mirror reflectivity under charge-exchange atom bombardment (erosion) and impurity deposition, permanent and dynamic loss of window, and optical fiber transmission under intense neutron and gamma-ray fluxes, are either absent or not as severe in the near-infrared (NIR, 750-2000 nm) range. An initial survey of NIR diagnostic applications has been undertaken on the National Spherical Torus Experiment. It is demonstrated that NIR spectroscopy can be used for machine protection and plasma control applications, as well as contribute to plasma performance evaluation and physics studies. Emission intensity estimates demonstrate that NIR measurements are possible in the BPX plasma operating parameter range. Complications in the NIR range due to the parasitic background emissions are expected to occur at very high plasma densities, low impurity densities, and at high plasma-facing component temperatures.

14.
Phys Rev Lett ; 97(7): 075002, 2006 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-17026238

RESUMEN

Extensive lithium wall coatings and liquid lithium plasma-limiting surfaces reduce recycling, with dramatic improvements in Ohmic plasma discharges in the Current Drive Experiment-Upgrade. Global energy confinement times increase by up to 6 times. These results exceed confinement scalings such as ITER98P(y,1) by 2-3 times, and represent the largest increase in energy confinement ever observed for an Ohmic tokamak plasma. Measurements of Dalpha emission indicate that global recycling coefficients decrease to approximately 0.3, the lowest documented for a magnetically confined hydrogen plasma.

15.
Phys Rev Lett ; 88(3): 035003, 2002 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-11801067

RESUMEN

We report observations of the first low-to-high ( L-H) confinement mode transitions in the National Spherical Torus Experiment. The H-mode energy confinement time increased over reference discharges transiently by 100-200%, as high as approximately 100 ms. This confinement time is approximately 2 times higher than predicted by a multimachine scaling. Thus the confinement time of spherical tori has been extended to a record high value, leading to an eventual revision of confinement scalings. Finally, the power threshold for H-mode access is >10x higher than predicted by an international scaling from conventional aspect-ratio tokamaks, which could lead to new understanding of H-mode transition dynamics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...