Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Tomography ; 9(1): 89-97, 2023 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-36648995

RESUMEN

Background and Purpose: Fully automated methods for segmentation and volume quantification of intraparenchymal hemorrhage (ICH), intraventricular hemorrhage extension (IVH), and perihematomal edema (PHE) are gaining increasing interest. Yet, reliabilities demonstrate considerable variances amongst each other. Our aim was therefore to evaluate both the intra- and interrater reliability of ICH, IVH and PHE on ground-truth segmentation masks. Methods: Patients with primary spontaneous ICH were retrospectively included from a German tertiary stroke center (Charité Berlin; January 2016−June 2020). Baseline and follow-up non-contrast Computed Tomography (NCCT) scans were analyzed for ICH, IVH, and PHE volume quantification by two radiology residents. Raters were blinded to all demographic and outcome data. Inter- and intrarater agreements were determined by calculating the Intraclass Correlation Coefficient (ICC) for a randomly selected set of patients with ICH, IVH, and PHE. Results: 100 out of 670 patients were included in the analysis. Interrater agreements ranged from an ICC of 0.998 for ICH (95% CI [0.993; 0.997]), to an ICC of 0.979 for IVH (95% CI [0.984; 0.993]), and an ICC of 0.886 for PHE (95% CI [0.760; 0.938]), all p-values < 0.001. Intrarater agreements ranged from an ICC of 0.997 for ICH (95% CI [0.996; 0.998]), to an ICC of 0.995 for IVH (95% CI [0.992; 0.996]), and an ICC of 0.980 for PHE (95% CI [0.971; 0.987]), all p-values < 0.001. Conclusion Manual segmentations of ICH, IVH, and PHE demonstrate good-to-excellent inter- and intrarater reliabilities, with the highest agreement for ICH and IVH and lowest for PHE. Therefore, the degree of variances reported in fully automated quantification methods might be related amongst others to variances in ground-truth masks.


Asunto(s)
Hemorragia Cerebral , Máscaras , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/patología , Edema
2.
J Clin Med ; 10(11)2021 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-34063991

RESUMEN

BACKGROUND: There is a need to examine the effects of different types of oral anticoagulant-associated intracerebral hemorrhage (OAC-ICH) on perihematomal edema (PHE), which is gaining considerable appeal as a biomarker for secondary brain injury and clinical outcome. METHODS: In a large multicenter approach, computed tomography-derived imaging markers for PHE (absolute PHE, relative PHE (rPHE), edema expansion distance (EED)) were calculated for patients with OAC-ICH and NON-OAC-ICH. Exploratory analysis for non-vitamin-K-antagonist OAC (NOAC) and vitamin-K-antagonists (VKA) was performed. The predictive performance of logistic regression models, employing predictors of poor functional outcome (modified Rankin scale 4-6), was explored. RESULTS: Of 811 retrospectively enrolled patients, 212 (26.14%) had an OAC-ICH. Mean rPHE and mean EED were significantly lower in patients with OAC-ICH compared to NON-OAC-ICH, p-value 0.001 and 0.007; whereas, mean absolute PHE did not differ, p-value 0.091. Mean EED was also significantly lower in NOAC compared to NON-OAC-ICH, p-value 0.05. Absolute PHE was an independent predictor of poor clinical outcome in NON-OAC-ICH (OR 1.02; 95%CI 1.002-1.028; p-value 0.027), but not in OAC-ICH (p-value 0.45). CONCLUSION: Quantitative markers of early PHE (rPHE and EED) were lower in patients with OAC-ICH compared to those with NON-OAC-ICH, with significantly lower levels of EED in NOAC compared to NON-OAC-ICH. Increase of early PHE volume did not increase the likelihood of poor outcome in OAC-ICH, but was independently associated with poor outcome in NON-OAC-ICH. The results underline the importance of etiology-specific treatment strategies. Further prospective studies are needed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...