Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Clin Hypertens (Greenwich) ; 21(12): 1784-1794, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31769171

RESUMEN

The present paper reports trends in office blood pressure (BP) measurement (OBPM) and ambulatory blood pressure measurement (ABPM) with age in a large multi-center Indian all comers' population visiting primary care physicians. ABPM and OBPM data from 27 472 subjects (aged 51 ± 14 years, males 68.2%, treated 45.5%) were analyzed and compared. Individual differences between OBPM and ABPM patterns were compared for patients according to 10-year age categories. Results showed that systolic (S) BP values started to increase with age from the age of 40, BP variability (SD) increased from the age of 30 years. Diastolic (D) BP values started to decrease from the age of 50 years. Mean OBPM values were higher than daytime ABPM values (all P < .001) in all age-groups. The prevalence of white coat hypertension (WCH) and masked hypertension (MH) was based on OBPM and daytime, 24-hour, and nighttime average BPs together. WCH decreased with age from 15.1% and 12.4% in treated and untreated subjects at the youngest age to 7.2% and 6.9% in the oldest age, respectively. MH prevalence was higher for untreated than for treated subjects but remained similar for all age-groups (range of 18.6%-21.3%). The prevalence of reverse dippers increased with age from the youngest to oldest group with 7.3%-34.2% (P < .001 for trend). Dippers prevalence decreased from 42.5% to 17.9% from the youngest to oldest age-groups, respectively (P < .001 for trend). These findings confirm that BP patterns show clear differences in trends with age, particularly regarding nighttime BP.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/métodos , Presión Sanguínea/fisiología , Hipertensión/fisiopatología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Antihipertensivos/uso terapéutico , Variación Biológica Poblacional/fisiología , Estudios de Casos y Controles , Ritmo Circadiano , Diástole/fisiología , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/tratamiento farmacológico , India/epidemiología , Masculino , Hipertensión Enmascarada/diagnóstico , Hipertensión Enmascarada/tratamiento farmacológico , Hipertensión Enmascarada/epidemiología , Persona de Mediana Edad , Prevalencia , Atención Primaria de Salud/estadística & datos numéricos , Sístole/fisiología , Hipertensión de la Bata Blanca/diagnóstico , Hipertensión de la Bata Blanca/tratamiento farmacológico , Hipertensión de la Bata Blanca/epidemiología
2.
Cardiovasc Revasc Med ; 19(4): 429-432, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29174500

RESUMEN

OBJECTIVES: To report long-term results of a novel sirolimus-eluting stent with biodegradable polymer BACKGROUND: Newer generation drug-eluting stents are characterized by thin struts, improved platform design and highly biocompatible polymer carrying the antiproliferative drug. The RapstromTM stent, sharing these features, showed promising outcomes in preclinical models and in a first-in-man trial. METHODS: The present study is a multicenter, non-randomized post-market registry, including patients with de novo coronary artery disease treated with implantation of one or more Rapstrom stents. Primary endpoint of the study was the rate of major adverse cardiac events (MACE) at three-year follow-up. RESULTS: 1073 patients were enrolled, with a high prevalence of diabetes (35%) and acute coronary syndrome at presentation (82%); at three-year follow up, MACE rate was 14.8%, with a low incidence of definite or probable stent thrombosis (0.75%). CONCLUSIONS: These data confirm the good clinical performance of the Rapstrom stent, supporting the concept that the combination of thin struts and biodegradable polymer is associated with positive clinical outcomes.


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/cirugía , Fármacos Cardiovasculares/administración & dosificación , Estenosis Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/epidemiología , Fármacos Cardiovasculares/efectos adversos , Comorbilidad , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/epidemiología , Trombosis Coronaria/epidemiología , Humanos , Incidencia , Intervención Coronaria Percutánea/efectos adversos , Prevalencia , Vigilancia de Productos Comercializados , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento