Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Circ Arrhythm Electrophysiol ; : e013059, 2024 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-39440428

RESUMEN

BACKGROUND: Left bundle branch area pacing (LBBAP) may be an alternative to biventricular pacing (BVP) for cardiac resynchronization therapy (CRT). We sought to compare the acute hemodynamic and ECG effects of LBBAP, BVP, and left bundle-optimized therapy CRT (LOT-CRT) in CRT candidates with advanced conduction disease. METHODS: In this multicenter study, 48 patients with either nonspecific interventricular conduction delay (n=29) or left bundle branch block (n=19) underwent acute hemodynamic testing to determine the change in left ventricular pressure maximal first derivative (LV dP/dtmax) from baseline atrial pacing to BVP, LBBAP, or LOT-CRT. RESULTS: Atrioventricular-optimized increases in LV dP/dtmax for LOT-CRT (mean, 25.8% [95% CI, 20.9%-30.7%]) and BVP (26.4% [95% CI, 20.2%-32.6%]) were greater than unipolar LBBAP (19.3% [95% CI, 15.0%-23.7%]) or bipolar LBBAP (16.4% [95% CI, 12.7%-20.0%]; P≤0.005). QRS shortening was greater in LOT-CRT (29.5 [95% CI, 23.4-35.6] ms) than unipolar LBBAP (11.9 [95% CI, 6.1-17.7] ms), bipolar LBBAP (11.7 ms [95% CI, 6.4-17.0]), or BVP (18.5 [95% CI, 11.0-25.9] ms), all P≤0.005. Compared with patients with left bundle branch block, patients with interventricular conduction delay experienced less QRS reduction (P=0.026) but similar improvements in LV dP/dtmax (P=0.29). Bipolar LBBAP caused anodal capture in 54% of patients and resulted in less LV dP/dtmax improvement than unipolar LBBAP (18.6% versus 23.7%; P<0.001). Subclassification of LBBAP capture (EHRA criteria) indicated LBBAP or LV septal pacing in 27 patients (56%) and deep septal pacing in 21 patients (44%). The hemodynamic benefit of adding left ventricular coronary vein pacing to LBBAP depended on baseline QRS duration (P=0.031) and success of LBBAP (P<0.004): LOT-CRT provided 14.5% (5.0%-24.1%) greater LV dP/dtmax improvement and 20.8 (12.8-28.8) ms greater QRS shortening than LBBAP in subjects with QRS ≥171 ms and deep septal pacing capture type. CONCLUSIONS: In a CRT cohort with advanced conduction disease, LOT-CRT and BVP provided greater acute hemodynamic benefit than LBBAP. Subjects with wider QRS or deep septal pacing are more likely to benefit from the addition of a left ventricular coronary vein lead to implement LOT-CRT. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04905290.

2.
Heart Rhythm ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39029885

RESUMEN

BACKGROUND: Delivery of cardiac resynchronization therapy (CRT) requires left ventricular myocardial capture to achieve clinical benefits. OBJECTIVE: We sought to determine whether ineffective pacing affects survival. METHODS: Ineffective ventricular pacing (VP) was defined as the difference between the percentage of delivered CRT (%VP) and the percentage of effective CRT in CRT devices. Using the Optum de-identified electronic health record data set and Medtronic CareLink data warehouse, we identified patients implanted with applicable devices with at least 30 days of follow-up. Kaplan-Meier and Cox proportional hazards models assessed the impact of %VP and % ineffective VP on survival. RESULTS: Among 7987 patients with 2.1 ± 1.0 years of follow-up, increasing ineffective VP was associated with decreasing survival: the highest observed survival was in the quartile with <0.08% ineffective VP and the lowest survival was in the quartile with >1.47% ineffective VP (85.1% vs 75.7% at 3 years; P < .001). As expected, patients with more than the median %VP of 97.7% had better survival than did patients with <97.7% VP (84.2% vs 77.8%; P < .001). However, patients who had >97.7% VP but >2% ineffective VP had similar survival to patients with <97.7% VP but ≤2% ineffective VP (81.6% vs 79.4%; P = .54). A multivariable Cox proportional hazards model demonstrated that <97.7% VP (adjusted hazard ratio 1.29; 95% confidence interval 1.14-1.46; P < .001) and >2% ineffective VP (hazard ratio 1.35; 95% confidence interval 1.18-1.54; P < .001) were both significantly associated with decreased survival. CONCLUSION: Ineffective VP is associated with decreased survival. In addition to maximizing the percentage of delivered CRT pacing, every effort should be made to minimize ineffective VP.

3.
J Cardiovasc Transl Res ; 16(6): 1448-1460, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37674046

RESUMEN

The aim was to test the hypothesis that left ventricular (LV) and right ventricular (RV) activation from body surface electrical mapping (CardioInsight 252-electrode vest, Medtronic) identifies optimal cardiac resynchronization therapy (CRT) pacing strategies and outcomes in 30 patients. The LV80, RV80, and BIV80 were defined as the times to 80% LV, RV, or biventricular electrical activation. Smaller differences in the LV80 and RV80 (|LV80-RV80|) with synchronized LV pacing predicted better LV function post-CRT (p = 0.0004) than the LV-paced QRS duration (p = 0.32). Likewise, a lower RV80 was associated with a better pre-CRT RV ejection fraction by CMR (r = - 0.40, p = 0.04) and predicted post-CRT improvements in myocardial oxygen uptake (p = 0.01) better than the biventricular-paced QRS (p = 0.38), while a lower LV80 with BIV pacing predicted lower post-CRT B-type natriuretic peptide (BNP) (p = 0.02). RV pacing improved LV function with smaller |LV80-RV80| (p = 0.009). In conclusion, 3-D electrical mapping predicted favorable post-CRT outcomes and informed effective pacing strategies.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología , Dispositivos de Terapia de Resincronización Cardíaca , Ventrículos Cardíacos
5.
Am J Cardiol ; 203: 436-443, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37540902

RESUMEN

Left bundle branch area pacing (LBBAP) has emerged as a promising physiological pacing modality. This study was designed to investigate the acute impact of the atrioventricular delay (AVD) on cardiac electrical characteristics and identify an optimal range of AVDs for LBBAP to achieve electrical atrioventricular and interventricular synchrony. Patients indicated for ventricular or biventricular pacing were studied during routine follow-ups at least 3 months after LBBAP implantation. Patients were excluded if they had a complete AV block or persistent atrial fibrillation. AVD was programed from 40 to 240 ms or until intrinsic conduction occurred. Optimal AVD was determined by the electrocardiography criteria, including QRS duration, reduced R-wave in lead V1, reduced notching or slurring in lateral leads, and more desirable precordial QRS transition. A total of 38 patients (age 68.7 ± 10.3 years; 16 male (42%); 18 dual-chamber pacemakers and 20 cardiac resynchronization therapy devices; average follow-up period 15.1 ± 10.2 months) were included. The fusion of LBBAP and intrinsic right ventricular conduction occurred in 21 patients with corresponding optimal AVD determined. A great proportion (∼85%) of the optimal AVDs ranged from 50% to 80% of the observed atrium-to-left bundle branch-sensing (A-LBBS) intervals. The linear correlation between the optimal AVD and corresponding A-LBBS interval (optimal AVD = 0.84 × [A-LBSs interval] - 36 ms) produced R = 0.86 and p <0.0001. In conclusion, AVD selection during LBBAP greatly impacted the ventricular electrical characteristics and the optimal AVD was linearly correlated with the corresponding A-LBBS interval.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Anciano , Bradicardia/terapia , Bloqueo de Rama/terapia , Sistema de Conducción Cardíaco , Electrocardiografía , Insuficiencia Cardíaca/terapia , Estimulación Cardíaca Artificial , Fascículo Atrioventricular , Resultado del Tratamiento
6.
Heart Rhythm O2 ; 4(3): 171-179, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36993911

RESUMEN

Background: Prolongation of the PR interval has long been considered a benign condition, particularly in the setting of nonstructural heart disease. Objective: The purpose of this study was to investigate the effect of PR interval on various well-adjudicated cardiovascular outcomes using a large real-world population data of patients with implanted dual-chamber permanent pacemakers or implantable cardioverter-defibrillators. Methods: PR intervals were measured during remote transmissions in patients with implanted permanent pacemakers or implantable cardioverter-defibrillators. Study endpoints (time to the first occurrence of AF, heart failure hospitalization [HFH], or death) were obtained between January 2007 and June 2019 from the deidentified Optum de-identified Electronic Health Record dataset. Results: A total of 25,752 patients (age 69.3 ± 13.9 years; 58% male) were evaluated. The average intrinsic PR interval was 185 ± 55 ms. In the subset of 16,730 patients with available long-term device diagnostic data, a total of 2555 (15.3%) individuals developed AF during 2.59 ± 2.18 years of follow-up. The incidence of AF was significantly higher (up to 30%) in patients with a longer PR interval (ie, PR interval ≥270 ms; P < .05). Time-to-event survival analysis and multivariable analysis showed that PR interval ≥190 ms was significantly associated with higher incidence of AF, HFH, or HFH or death when compared with shorter PR intervals (P < .05 for all 3 parameters). Conclusion: In a large real-world population of patients with implanted devices, PR interval prolongation was significantly associated with increased incidence of AF, HFH, or death.

7.
Heart Rhythm O2 ; 4(2): 79-87, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36873311

RESUMEN

Background: A screening tool to predict response to cardiac resynchronization therapy (CRT) could improve patient selection and outcomes. Objective: The purpose of this study was to investigate the feasibility and safety of noninvasive CRT via transcutaneous ultrasonic left ventricular (LV) pacing applied as a screening test before CRT implants. Methods: P-wave-triggered ultrasound stimuli were delivered during bolus dosing of an echocardiographic contrast agent to simulate CRT noninvasively. Ultrasound pacing was delivered at a variety of LV locations with a range of atrioventricular delays to achieve fusion with intrinsic ventricular activation. Three-dimensional cardiac activation maps were acquired via the Medtronic CardioInsight 252-electrode mapping vest during baseline, ultrasound pacing, and after CRT implantation. A separate control group received only the CRT implants. Results: Ultrasound pacing was achieved in 10 patients with a mean of 81.2 ± 50.8 ultrasound paced beats per patient and up to 20 consecutive beats of ultrasound pacing. QRS width at baseline (168.2 ± 17.8 ms) decreased significantly to 117.3 ± 21.5 ms (P <.001) in the best ultrasound paced beat and to 125.8 ± 13.3 ms (P <.001) in the best CRT beat. Electrical activation patterns were similar between CRT pacing and ultrasound pacing with stimulation from the same area of the LV. Troponin results were similar between the ultrasound pacing and the control groups (P = .96), confirming safety. Conclusion: Noninvasive ultrasound pacing before CRT is safe and feasible, and it estimates the degree of electrical resynchronization achievable with CRT. Further study of this promising technique to guide CRT patient selection is warranted.

8.
Front Cardiovasc Med ; 9: 888269, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35548436

RESUMEN

Background: Contemporary Left Ventricular Assist Devices (LVADs) mainly operate at a constant speed, only insufficiently adapting to changes in patient demand. Automatic physiological speed control promises tighter integration of the LVAD into patient physiology, increasing the level of support during activity and decreasing support when it is excessive. Methods: A sensorless modular control algorithm was developed for a centrifugal LVAD (HVAD, Medtronic plc, MN, USA). It consists of a heart rate-, a pulsatility-, a suction reaction-and a supervisor module. These modules were embedded into a safe testing environment and investigated in a single-center, blinded, crossover, clinical pilot trial (clinicaltrials.gov, NCT04786236). Patients completed a protocol consisting of orthostatic changes, Valsalva maneuver and submaximal bicycle ergometry in constant speed and physiological control mode in randomized sequence. Endpoints for the study were reduction of suction burden, adequate pump speed and flowrate adaptations of the control algorithm for each protocol item and no necessity for intervention via the hardware safety systems. Results: A total of six patients (median age 53.5, 100% male) completed 13 tests in the intermediate care unit or in an outpatient setting, without necessity for intervention during control mode operation. Physiological control reduced speed and flowrate during patient rest, in sitting by a median of -75 [Interquartile Range (IQR): -137, 65] rpm and in supine position by -130 [-150, 30] rpm, thereby reducing suction burden in scenarios prone to overpumping in most tests [0 [-10, 2] Suction events/minute] in orthostatic upwards transitions and by -2 [-6, 0] Suction events/min in Valsalva maneuver. During submaximal ergometry speed was increased by 86 [31, 193] rpm compared to constant speed for a median flow increase of 0.2 [0.1, 0.8] L/min. In 3 tests speed could not be increased above constant set speed due to recurring suction and in 3 tests speed could be increased by up to 500 rpm with a pump flowrate increase of up to 0.9 L/min. Conclusion: In this pilot study, safety, short-term efficacy, and physiological responsiveness of a sensorless automated speed control system for a centrifugal LVAD was established. Long term studies are needed to show improved clinical outcomes. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT04786236.

9.
Life (Basel) ; 12(4)2022 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-35455054

RESUMEN

Advanced stage heart failure patients can benefit from the unloading effects of an implantable left ventricular assist device. Despite best clinical practice, LVADs are associated with adverse events, such as pump thrombosis (PT). An adaptive algorithm alerting when an individual's appropriate levels in pump power uptake are exceeded, such as in the case of PT, can improve therapy of patients implanted with a centrifugal LVAD. We retrospectively studied 75 patients implanted with a centrifugal LVAD in a single center. A previously optimized adaptive pump power-tracking algorithm was compared to clinical best practice and clinically available constant threshold algorithms. Algorithm performances were analyzed in a PT group (n = 16 patients with 30 PT events) and a thoroughly selected control group (n = 59 patients, 34.7 patient years of LVAD data). Comparison of the adaptive power-tracking algorithm with the best performing constant threshold algorithm resulted in sensitivity of 83.3% vs. 86.7% and specificity of 98.9% vs. 95.3%, respectively. The power-tracking algorithm produced one false positive detection every 11.6 patient years and early warnings with a median of 3.6 days prior to PT diagnosis. In conclusion, a retrospective single-center validation study with real-world patient data demonstrated advantageous application of a power-tracking algorithm into LVAD systems and clinical practice.

10.
Nanoscale ; 13(40): 17011-17021, 2021 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-34617536

RESUMEN

Destructive quantum interference (QI) has been a source of interest as a new paradigm for molecular electronics as the electronic conductance is widely dependent on the occurrence or absence of destructive QI effects. In order to interpret experimentally observed transmission features, it is necessary to understand the effects of all components of the junction on electron transport. We perform non-equilibrium Green's function calculations within the framework of density functional theory to assess the structure-function relationship of transport through pyrene molecular junctions with distinct QI properties. The chemical nature of the anchor groups and the electrodes controls the Fermi level alignment, which determines the observability of destructive QI. A thorough analysis allows to disentangle the transmission features arising from the molecule and the electrodes. Interestingly, graphene electrodes introduce features in the low-bias regime, which can either mask or be misinterpreted as QI effects, while instead originating from the topological properties of the edges. Thus, this first principles analysis provides clear indications to guide the interpretation of experimental studies, which cannot be obtained from simple Hückel model calculations.

11.
ASAIO J ; 67(9): 1018-1025, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34225279

RESUMEN

Logfiles from the HeartWare HVAD System provide operational pump trend data to aid in patient management. Pump thrombosis is commonly associated with increases in the logfile power that may precede the clinical presentation. A Power Tracking algorithm was developed to detect significant deviations in pump power that may be associated with pump thrombus (PT). The Power Tracking algorithm was applied retrospectively to logfiles captured in the ENDURANCE, ENDURANCE Supplemental, and LATERAL clinical trials. From a combined dataset of 896 patients, available logfiles with suspected PT (n = 70 events in 60 patients) and available logfiles from patients without adverse events (AEs) (n = 106 patients, consisting of 27.4 patient-years of monitoring) were organized into two cohorts. The Power Tracking algorithm detected PT cases on or before the recorded AE date with a sensitivity of 85.7%, with detection occurring an average of 3.9 days before clinical presentation. The algorithm averaged one false alarm for every 6.85 patient-years of monitoring from logfiles without AEs. The favorable performance of the Power Tracking algorithm may enable earlier detection of pump thrombosis and allow early medical management versus surgical intervention.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Trombosis , Algoritmos , Diagnóstico Precoz , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Trombosis/diagnóstico , Trombosis/etiología
12.
Nanoscale Horiz ; 6(1): 49-58, 2021 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-33107543

RESUMEN

The ability to control the charge state of individual molecules wired in two-terminal single-molecule junctions is a key challenge in molecular electronics, particularly in relation to the development of molecular memory and other computational componentry. Here we demonstrate that single porphyrin molecular junctions can be reversibly charged and discharged at elevated biases under ambient conditions due to the presence of a localised molecular eigenstate close to the Fermi edge of the electrodes. In particular, we can observe long-lived charge-states with lifetimes upwards of 1-10 seconds after returning to low bias and large changes in conductance, in excess of 100-fold at low bias. Our theoretical analysis finds charge-state lifetimes within the same time range as the experiments. The ambient operation demonstrates that special conditions such as low temperatures or ultra-high vacuum are not essential to observe hysteresis and stable charged molecular junctions.

13.
Heart Rhythm ; 16(7): 983-989, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31102750

RESUMEN

BACKGROUND: The AdaptivCRT algorithm (aCRT) automatically adjusts atrioventricular delays each minute to achieve ventricular fusion through left ventricular (LV) or biventricular (BiV) pacing. aCRT is associated with superior clinical outcomes compared to standard BiV pacing, but the association of aCRT and subsequent atrial fibrillation (AF) in a real-world population has not been fully evaluated. OBJECTIVE: The purpose of this study was to investigate the incidence of AF ≥48 hours with aCRT vs standard BiV pacing after implant. METHODS: Patients implanted with a cardiac resynchronization therapy (CRT) device between 2013 and 2016 were studied via the de-identified Medtronic CareLink database. For univariate and multivariate survival analyses, Kaplan-Meier and Cox proportional hazards were used, respectively. RESULTS: Of 37,450 patients (mean age 69.1 ± 11.0 years; 67.9% male) followed for a mean 15.5 ± 9.1 months, 9.7% (n = 3647) developed ≥48 hours of AF. In univariate analysis, compared with standard BiV pacing, the aCRT BiV and LV mode was associated with a 54% lower risk of ≥48 hours of AF (P <.001) at 2 years, which persisted after multivariate adjustment (hazard ratio 0.53; 95% confidence interval 0.49-0.57; P <.001), even when stratified by sensed PR interval ≤200 ms and >200 ms. Higher percentages of LV-only pacing with aCRT were associated with lower incidence of AF (comparing >92% LV-only pacing vs 0%-5% LV-only pacing: HR 0.05; 95% CI 0.04-0.06; P <.001). CONCLUSION: In a large, real-world population of CRT recipients, aCRT pacing compared to standard BiV pacing was associated with a lower incidence of AF in patients with both long and short PR intervals. A higher percentage of LV-only pacing during aCRT was also associated with lower incidence of AF.


Asunto(s)
Fibrilación Atrial/epidemiología , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/prevención & control , Anciano , Algoritmos , Femenino , Humanos , Incidencia , Masculino , Tecnología de Sensores Remotos
14.
Heart Rhythm ; 15(3): 369-375, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29132930

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) requires a high percentage of ventricular pacing (%Vp) to maximize its clinical benefits. Atrial fibrillation (AF) has been shown to reduce %Vp in CRT due to competition with irregular intrinsic atrioventricular (AV) conduction. We report the results of a prospective randomized crossover trial evaluating the amount of effective CRT delivered during AF with a novel algorithm (eCRTAF). OBJECTIVE: The purpose of this study was to determine whether eCRTAF increases the amount of effective CRT delivered during AF compared to a currently available rate regularization algorithm. METHODS: Patients previously implanted with a cardiac resynchronization therapy-defibrillator and with a history of AF and intact AV conduction received up to 4 weeks of control (Conducted AF Response) and up to 4 weeks of eCRTAF in a randomized sequence. The percent effective CRT (%eCRT) pacing, which excludes beats without left ventricular capture, %Vp, and mean heart rate (HR) were recorded during AF and sinus rhythm. RESULTS: The eCRTAF algorithm resulted in a significantly higher %eCRT during AF than control (87.8% ± 7.8% vs 80.8% ± 14.3%; P <.001) and %Vp during AF than control (90.0% ± 5.9% vs 83.2% ± 11.9%; P <.001), with a small but statistically significant increase in mean HR of 2.5 bpm (79.5 ± 9.7 bpm vs 77.0 ± 9.9 bpm; P <.001). CONCLUSION: In a cohort of CRT patients with a history of AF, eCRTAF significantly increased %eCRT pacing and %Vp during AF with a small increase in mean HR. This algorithm may represent a novel noninvasive method of significantly increasing effective CRT delivery during AF, potentially improving CRT response.


Asunto(s)
Algoritmos , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/métodos , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Fibrilación Atrial/fisiopatología , Estudios Cruzados , Humanos , Estudios Prospectivos , Resultado del Tratamiento
15.
Europace ; 19(5): 831-837, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-27230561

RESUMEN

AIMS: Cardiac resynchronization therapy (CRT) requires effective left ventricular (LV) pacing (i.e. sufficient energy and appropriate timing to capture). The AdaptivCRT™ (aCRT) algorithm serves to maintain ventricular fusion during LV or biventricular pacing. This function was tested by comparing the morphological consistency of ventricular depolarizations and percentage effective LV pacing in CRT patients randomized to aCRT vs. echo-optimization. METHODS AND RESULTS: Continuous recordings (≥20 h) of unipolar LV electrograms from aCRT (n = 38) and echo-optimized patients (n = 22) were analysed. Morphological consistency was determined by the correlation coefficient between each beat and a template beat. Effective LV pacing of paced beats was assessed by algorithmic analysis of negative initial EGM deflection in each evoked response. The %CRT pacing delivered, %effective LV pacing (i.e. % of paced beats with effective LV pacing), and overall %effective CRT (i.e. product of %CRT pacing and %effective LV pacing) were compared between aCRT and echo-optimized patients. Demographics were similar between groups. The mean correlation coefficient between individual beats and template was greater for aCRT (0.96 ± 0.03 vs. 0.91 ± 0.13, P = 0.07). Although %CRT pacing was similar for aCRT and echo-optimized (median 97.4 vs. 98.6%, P = 0.14), %effective LV pacing was larger for aCRT [99.6%, (99.1%, 99.9%) vs. 94.3%, (24.3%, 99.8%), P=0.03]. For aCRT vs. echo-optimized groups, the proportions of patients with ≥90% effective LV pacing was 92 vs. 55% (P = 0.002), and with ≥90% effective CRT was 79 vs. 45%, respectively (P = 0.018). CONCLUSION: AdaptivCRT™ significantly increased effective LV pacing over echo-optimized CRT.


Asunto(s)
Algoritmos , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/prevención & control , Terapia Asistida por Computador/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Estados Unidos
16.
Monatsh Chem ; 147(10): 1675-1686, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27729711

RESUMEN

ABSTRACT: The paper provides a comprehensive theoretical description of electron transport through transition metal complexes in single molecule junctions, where the main focus is on an analysis of the structural parameters responsible for bias-induced conductance switching as found in recent experiments, where an interpretation was provided by our simulations. The switching could be theoretically explained by a two-channel model combining coherent electron transport and electron hopping, where the underlying mechanism could be identified as a charging of the molecule in the junction made possible by the presence of a localized electronic state on the transition metal center. In this article, we present a framework for the description of an electron hopping-based switching process within the semi-classical Marcus-Hush theory, where all relevant quantities are calculated on the basis of density functional theory (DFT). Additionally, structural aspects of the junction and their respective importance for the occurrence of irreversible switching are discussed.

17.
Angew Chem Int Ed Engl ; 55(39): 11781-6, 2016 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-27553767

RESUMEN

Azulene (Az) is a non-alternating, aromatic hydrocarbon composed of a five-membered, electron-rich and a seven-membered, electron-poor ring; an electron distribution that provides intrinsic redox activity. By varying the attachment points of the two electrode-bridging substituents to the Az center, the influence of the redox functionality on charge transport is evaluated. The conductance of the 1,3 Az derivative is at least one order of magnitude lower than those of the 2,6 Az and 4,7 Az derivatives, in agreement with density functional theory (DFT) calculations. In addition, only 1,3 Az exhibits pronounced nonlinear current-voltage characteristics with hysteresis, indicating a bias-dependent conductance switching. DFT identifies the LUMO to be nearest to the Fermi energy of the electrodes, but to be an active transport channel only in the case of the 2,6 and the 4,7 Az derivatives, whereas the 1,3 Az derivative uses the HOMO at low and the LUMO+1 at high bias. In return, the localized, weakly coupled LUMO of 1,3 Az creates a slow electron-hopping channel responsible for the voltage-induced switching due to the occupation of a single molecular orbital (MO).

18.
Nat Nanotechnol ; 11(2): 170-6, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26571004

RESUMEN

Charge transport through single molecules can be influenced by the charge and spin states of redox-active metal centres placed in the transport pathway. These intrinsic properties are usually manipulated by varying the molecule's electrochemical and magnetic environment, a procedure that requires complex setups with multiple terminals. Here we show that oxidation and reduction of organometallic compounds containing either Fe, Ru or Mo centres can solely be triggered by the electric field applied to a two-terminal molecular junction. Whereas all compounds exhibit bias-dependent hysteresis, the Mo-containing compound additionally shows an abrupt voltage-induced conductance switching, yielding high-to-low current ratios exceeding 1,000 at bias voltages of less than 1.0 V. Density functional theory calculations identify a localized, redox-active molecular orbital that is weakly coupled to the electrodes and closely aligned with the Fermi energy of the leads because of the spin-polarized ground state unique to the Mo centre. This situation provides an additional slow and incoherent hopping channel for transport, triggering a transient charging effect in the entire molecule with a strong hysteresis and large high-to-low current ratios.

19.
Nano Lett ; 15(11): 7175-6, 2015 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-26485189
20.
Europace ; 17(10): 1555-62, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25862307

RESUMEN

AIMS: Cardiac resynchronization therapy (CRT) devices report percentage pacing as a diagnostic but cannot determine the effectiveness of each paced beat in capturing left-ventricular (LV) myocardium. Reasons for ineffective LV pacing include improper timing (i.e. pseudofusion) or inadequate pacing output. Device-based determination of effective LV pacing may facilitate optimization of CRT response. METHODS AND RESULTS: Effective capture at the LV cathode results in a negative deflection (QS or QS-r morphology) on a unipolar electrogram (EGM). Morphological features of LV cathode-RV coil EGMs were analysed to develop a device-based automatic algorithm, which classified each paced beat as effective or ineffective LV pacing. The algorithm was validated using acute data from 28 CRT-defibrillator patients. Effective LV pacing and pseudofusion was simulated by pacing at various AV delays. Loss of LV capture was simulated by RV-only pacing. The algorithm always classified LV or biventricular (BV) pacing with AV delays ≤60% of patient's intrinsic AV delay as effective pacing. As AV delays increased, the percentage of beats classified as effective LV pacing decreased. Algorithm results were compared against a classification truth based on correlation coefficients between paced QRS complexes and intrinsic rhythm QRS templates from three surface ECG leads. An average correlation >0.9 defined a classification truth of ineffective pacing. Compared against the classification truth, the algorithm correctly classified 98.2% (3240/3300) effective LV pacing beats, 75.8% (561/740) of pseudofusion beats, and 100% (540/540) of beats with loss of LV capture. CONCLUSION: A device-based algorithm for beat-by-beat monitoring of effective LV pacing is feasible.


Asunto(s)
Algoritmos , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Anciano , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...