Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Med Phys ; 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39134054

RESUMEN

BACKGROUND: Dynamic Computed Tomography Angiography (4D CTA) has the potential of providing insight into the biomechanical properties of the vessel wall, by capturing motion of the vessel wall. For vascular pathologies, like intracranial aneurysms, this could potentially refine diagnosis, prognosis, and treatment decision-making. PURPOSE: The objective of this research is to determine the feasibility of a 4D CTA scanner for accurately measuring harmonic diameter changes in an in-vitro simulated vessel. METHODS: A silicon tube was exposed to a simulated heartbeat. Simulated heart rates between 40 and 100 beats-per-minute (bpm) were tested and the flow amplitude was varied, resulting in various changes of tube diameter. A 320-detector row CT system with ECG-gating captured three consecutive cycles of expansion. Image registration was used to calculate the diameter change. A vascular echography set-up was used as a reference, using a 9 MHz linear array transducer. The reproducibility of 4D CTA was represented by the Pearson correlation (r) between the three consecutive diameter change patterns, captured by 4D CTA. The peak value similarity (pvs) was calculated between the 4D CTA and US measurements for increasing frequencies and was chosen as a measure of temporal resolution. Spatial resolution was represented by the Sum of the Relative Percentual Difference (SRPD) between 4D CTA and US diameter change patterns for increasing amplitudes. RESULTS: The reproducibility of 4D CTA measurements was good (r ≥ 0.9) if the diameter change was larger than 0.3 mm, moderate (0.7 ≤ r < 0.9) if the diameter change was between 0.1 and 0.3 mm, and low (r < 0.7) if the diameter change was smaller than 0.1 mm. Regarding the temporal resolution, the amplitude of 4D CTA was similar to the US measurements (pvs ≥ 90%) for the frequencies of 40 and 50 bpm. Frequencies between 60 and 80 bpm result in a moderate similarity (70% ≤ pvs < 90%). A low similarity (pvs < 70%) is observed for 90 and 100 bpm. Regarding the spatial resolution, diameter changes above 0.30 mm result in SRPDs consistently below 50%. CONCLUSION: In a phantom setting, 4D CTA can be used to reliably capture reproducible tube diameter changes exceeding 0.30 mm. Low pulsation frequencies (40 or 50 bpm) provide an accurate measurement of the maximum tube diameter change.

2.
Geroscience ; 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38509415

RESUMEN

The incidence of aortic valve stenosis (AoS) increases with age, and once diagnosed, symptomatic severe AoS has a yearly mortality rate of 25%. AoS is diagnosed with transthoracic echocardiography (TTE), however, this gold standard is time consuming and operator and acoustic window dependent. As AoS affects the arterial blood pressure waveform, AoS-specific waveform features might serve as a diagnostic tool. Aim of the present study was to develop a novel, non-invasive, AoS detection model based on blood pressures waveforms. This cross-sectional study included patients with AoS undergoing elective transcatheter or surgical aortic valve replacement. AoS was determined using TTE, and patients with no or mild AoS were labelled as patients without AoS, while patients with moderate or severe AoS were labelled as patients with AoS. Non-invasive blood pressure measurements were performed in awake patients. Ten minutes of consecutive data was collected. Several blood pressure-based features were derived, and the median, interquartile range, variance, and the 1st and 9th decile of the change of these features were calculated. The primary outcome was the development of a machine-learning model for AoS detection, investigating multiple classifiers and training on the area under the receiver-operating curve (AUROC). In total, 101 patients with AoS and 48 patients without AoS were included. Patients with AoS showed an increase in left ventricular ejection time (0.02 s, p = 0.001), a delayed maximum upstroke in the systolic phase (0.015 s, p < 0.001), and a delayed maximal systolic pressure (0.03 s, p < 0.001) compared to patients without AoS. With the logistic regression model, a sensitivity of 0.81, specificity of 0.67, and AUROC of 0.79 were found. The majority of the population without AoS was male (85%), whereas in the population with AoS this was evenly distributed (54% males). Age was significantly (5 years, p < 0.001) higher in the population with AoS. In the present study, we developed a novel model able to distinguish no to mild AoS from moderate to severe AoS, based on blood pressure features with high accuracy. Clinical registration number: The study entailing patients with TAVR treatment was registered at ClinicalTrials.gov (NCT03088787, https://clinicaltrials.gov/ct2/show/NCT03088787 ). The study with elective cardiac surgery patients was registered with the Netherland Trial Register (NL7810, https://trialsearch.who.int/Trial2.aspx?TrialID=NL7810 ).

3.
PLoS One ; 18(12): e0293353, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38134125

RESUMEN

BACKGROUND: Reliably capturing sub-millimeter vessel wall motion over time, using dynamic Computed Tomography Angiography (4D CTA), might provide insight in biomechanical properties of these vessels. This may improve diagnosis, prognosis, and treatment decision making in vascular pathologies. PURPOSE: The aim of this study is to determine the most suitable image reconstruction method for 4D CTA to accurately assess harmonic diameter changes of vessels. METHODS: An elastic tube (inner diameter 6 mm, wall thickness 2 mm) was exposed to sinusoidal pressure waves with a frequency of 70 beats-per-minute. Five flow amplitudes were set, resulting in increasing sinusoidal diameter changes of the elastic tube, measured during three simulated pulsation cycles, using ECG-gated 4D CTA on a 320-detector row CT system. Tomographic images were reconstructed using one of the following three reconstruction methods: hybrid iterative (Hybrid-IR), model-based iterative (MBIR) and deep-learning based (DLR) reconstruction. The three reconstruction methods where based on 180 degrees (half reconstruction mode) and 360 degrees (full reconstruction mode) raw data. The diameter change, captured by 4D CTA, was computed based on image registration. As a reference metric for diameter change measurement, a 9 MHz linear ultrasound transducer was used. The sum of relative absolute differences (SRAD) between the ultrasound and 4D CTA measurements was calculated for each reconstruction method. The standard deviation was computed across the three pulsation cycles. RESULTS: MBIR and DLR resulted in a decreased SRAD and standard deviation compared to Hybrid-IR. Full reconstruction mode resulted in a decreased SRAD and standard deviations, compared to half reconstruction mode. CONCLUSIONS: 4D CTA can capture a diameter change pattern comparable to the pattern captured by US. DLR and MBIR algorithms show more accurate results than Hybrid-IR. Reconstruction with DLR is >3 times faster, compared to reconstruction with MBIR. Full reconstruction mode is more accurate than half reconstruction mode.


Asunto(s)
Angiografía por Tomografía Computarizada , Interpretación de Imagen Radiográfica Asistida por Computador , Angiografía por Tomografía Computarizada/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Angiografía/métodos , Algoritmos , Procesamiento de Imagen Asistido por Computador , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...