Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38934146

RESUMEN

The aim of the presented prospective observational study was to evaluate the effect of fistula flow on peripheral wave morphology and pulse wave velocity by means of the oscillometric Vicorder®-device with the purpose of fistula surveillance. METHODS: Digitized and normalized curves of 53 haemodialysis patients at the fistula and non-fistula arm were analyzed. Slope parameters and the areas under the curve of characteristic sections of pulse waves as well as the power spectrum of the pulse waves and their first and second derivatives were computed. Furthermore, the amplitude of volumetric change (AMP) was assessed. Duplex-sonography served as a reference method. RESULTS: In the comprehensive set of novel pulse wave parameters significant inter-arm differences were demonstrated and a significant delay of the systolic maximum at the fistula arm in comparison to the non-fistula arm (204 ± 3.4 versus 162 ± 5.3 ms, p<0.001) was proven. Unexpectedly, pulse wave velocity apparently did not differ between both arms (7.85 versus 8.05 m/sec at the fistula/non-fistula side, p=0.942). The inter-arm differences of the slope parameters were more pronounced in forearm than in upper arm fistulas. Finally, we showed that the inter-arm difference of AMP correlated with volume-flow (r= 0.326 with p=0.017). CONCLUSION: Pulse waves as assessed by oscillometric pulse wave analysis have distinct features at fistula and non-fistula arms. This is due to enhanced arteriovenous flow, i.e. in both the brachial artery and the fistula vein. The analysis of those alterations has the potential to assess fistula function.

2.
BMC Nephrol ; 24(1): 186, 2023 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-37355570

RESUMEN

BACKGROUND: Pulse wave analysis may be useful to assess fistula function. We aimed to prospectively evaluate if convenient oscillometric devices are applicable to detect flow below 500 ml/min in a real life clinical setting. METHODS: Pulse waves were recorded ambilaterally with the vicorder® device at the brachial artery in 53 patients on haemodialysis with native fistula. Primary variables consisted of the mean slope between the systolic maximum and the diacrotic notch (Slope2), the sum of the mean slopes in the four characteristic sections of pulse waves (Slope∑) and the amplitude of relative volumetric change in the measuring cuff at the upper arm (AMP). Fistula flow was measured with the use of duplex sonography using a standardized approach. RESULTS: Parameter values above or below the median indicated measurement at the non-fistula side, with sensitivities/specificities of 0.79/0.79 (p < 0.001) for Slope 2, 0.64/0.64 (p = 0.003) for Slope∑ and 0.81/0.81 (p < 0.001) for AMP if measurements at the fistula and non-fistula arm were considered. ROC-analyses of parameter values measured at the fistula to detect low flow demonstrated AUCs (with CI) of 0.652 (0.437-0.866, p = 0.167) for Slope2, 0.732 (0.566-0.899, p = 0.006) for Slope∑ and 0.775 (0.56-0.991, p = 0.012) for AMP. The point with maximal youden's index was regarded as optimal cut-off, which corresponded to sensitivities and specificities of 0.8/0.56 for slope2, 0.86/ 0.56 for Slope∑ and 0.93/0.78 for AMP. CONCLUSION: Functional surveillance with oscillometry is a promising clinical application to detect a low fistula flow. Among all investigated pulse wave parameters AMP revealed the highest diagnostic accuracy.


Asunto(s)
Fístula Arteriovenosa , Arteria Braquial , Humanos , Oscilometría , Arteria Braquial/diagnóstico por imagen , Sensibilidad y Especificidad , Análisis de la Onda del Pulso
3.
Kidney Blood Press Res ; 45(4): 576-588, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32575106

RESUMEN

BACKGROUND/AIMS: Pulse wave analysis (PWA) and pulse wave velocity (PWV) provide information about arterial stiffness and elasticity, which is mainly used for cardiovascular risk stratification. In the presented prospective observational pilot study, we examined the hypothesis that radiocephalic fistula (RCF)-related changes of haemodynamics and blood vessel morphology including high as well as low flow can be seen in specific changes of pulse wave (PW) morphology. METHODS: Fifty-six patients with RCF underwent local ambilateral peripheral PWA and PWV measurement with the SphygmoCor® device. Given that the output parameters of the SphygmoCor® are not relevant for the study objectives, we defined new suitable parameters for PWA in direct proximity to fistulas and established an appropriate analysing algorithm. Duplex sonography served as reference method. RESULTS: Marked changes of peripheral PW morphology when considering interarm differences of slope and areas between the fistula and non-fistula arms were observed in the Arteria radialis, A. brachialis and arterialized Vena cephalica. The sum of the slope differences was found to correlate with an increased flow, while in patients with fistula failure no changes in PW morphology were seen. Moreover, PWV was significantly reduced in the fistula arm. CONCLUSION: Beside duplex sonography, ambilateral peripheral PWA and PWV measurements are potential new clinical applications to characterize and monitor RCF function, especially in terms of high and low flow.


Asunto(s)
Fístula Vascular/diagnóstico , Rigidez Vascular , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Análisis de la Onda del Pulso , Fístula Vascular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...