Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 44(1): 82-90, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36549845

RESUMEN

BACKGROUND AND PURPOSE: Fetal brain MR imaging interpretations are subjective and require subspecialty expertise. We aimed to develop a deep learning algorithm for automatically measuring intracranial and brain volumes of fetal brain MRIs across gestational ages. MATERIALS AND METHODS: This retrospective study included 246 patients with singleton pregnancies at 19-38 weeks gestation. A 3D U-Net was trained to segment the intracranial contents of 2D fetal brain MRIs in the axial, coronal, and sagittal planes. An additional 3D U-Net was trained to segment the brain from the output of the first model. Models were tested on MRIs of 10 patients (28 planes) via Dice coefficients and volume comparison with manual reference segmentations. Trained U-Nets were applied to 200 additional MRIs to develop normative reference intracranial and brain volumes across gestational ages and then to 9 pathologic fetal brains. RESULTS: Fetal intracranial and brain compartments were automatically segmented in a mean of 6.8 (SD, 1.2) seconds with median Dices score of 0.95 and 0.90, respectively (interquartile ranges, 0.91-0.96/0.89-0.91) on the test set. Correlation with manual volume measurements was high (Pearson r = 0.996, P < .001). Normative samples of intracranial and brain volumes across gestational ages were developed. Eight of 9 pathologic fetal intracranial volumes were automatically predicted to be >2 SDs from this age-specific reference mean. There were no effects of fetal sex, maternal diabetes, or maternal age on intracranial or brain volumes across gestational ages. CONCLUSIONS: Deep learning techniques can quickly and accurately quantify intracranial and brain volumes on clinical fetal brain MRIs and identify abnormal volumes on the basis of a normative reference standard.


Asunto(s)
Aprendizaje Profundo , Imagenología Tridimensional , Embarazo , Femenino , Humanos , Edad Gestacional , Imagenología Tridimensional/métodos , Estudios Retrospectivos , Encéfalo/diagnóstico por imagen
2.
AJNR Am J Neuroradiol ; 41(2): 213-218, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31974080

RESUMEN

BACKGROUND AND PURPOSE: Noncontrast head CTs are routinely acquired for patients with neurologic symptoms in the emergency department setting. Anecdotally, noncontrast head CTs performed in patients with prior negative findings with the same clinical indication are of low diagnostic yield. We hypothesized that the rate of acute findings in noncontrast head CTs performed in patients with a preceding study with negative findings would be lower compared with patients being imaged for the first time. MATERIALS AND METHODS: We retrospectively evaluated patients in the emergency department setting who underwent noncontrast head CTs at our institution during a 4-year period, recording whether the patient had undergone a prior noncontrast head CT, the clinical indication for the examination, and the examination outcome. Positive findings on examinations were defined as those that showed any intracranial abnormality that would necessitate a change in acute management, such as acute hemorrhage, hydrocephalus, herniation, or interval worsening of a prior finding. RESULTS: During the study period, 8160 patients in the emergency department setting underwent a total of 9593 noncontrast head CTs; 88.2% (7198/8160) had a single examination, and 11.8% (962/8160) had at least 1 repeat examination. The baseline positive rate of the "nonrepeat" group was 4.3% (308/7198). The 911 patients in the "repeat" group with negative findings on a baseline/first CT had a total of 1359 repeat noncontrast head CTs during the study period. The rate of positive findings for these repeat examinations was 1.8% (25/1359), significantly lower than the 4.3% baseline rate (P < .001). Of the repeat examinations that had positive findings, 80% (20/25) had a study indication that was discordant with that of the prior examination, compared with only 44% (593/1334) of the repeat examinations that had negative findings (P < .001). CONCLUSIONS: In a retrospective observational study based on approximately 10,000 examinations, we found that serial noncontrast head CT examinations in patients with prior negative findings with the same study indication are less likely to have positive findings compared with first-time examinations or examinations with a new indication. This finding suggests a negative predictive value of a prior noncontrast head CT examination with negative findings with the same clinical indication.


Asunto(s)
Cabeza/diagnóstico por imagen , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Servicio de Urgencia en Hospital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...