Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
BMC Pediatr ; 24(1): 400, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38898400

RESUMEN

OBJECTIVES: To compare the risk of acute kidney injury (AKI) between hospitalized children who received intravenous contrast media for imaging examinations and those who did not. METHODS: This retrospective cohort study enrolled patients aged 0-18 years with serum creatinine levels before and after imaging examinations from 2015 to 2020 at Beijing Children's Hospital. Participants were classified into an exposure group or a control group. Log-binomial regression analysis was used to estimate the adjusted risk ratio (aRR) value for the association between exposure to contrast media and consequential AKI. After which, inverse probability treatment weighting was used to reduce systematic differences in baseline characteristics among the groups. Moreover, subgroup and sensitivity analyses were performed. Finally, multivariate logistic regression analysis was performed to identify risk factors for pediatric AKI. RESULTS: In total, 3061 pediatric patients were included in the analyses (median age, 4.5 [IQR, 1.3-8.9] years, 1760 males). According the KDIGO definition of AKI, the incidence of AKI in the exposure group, and the control group were 7.4% and 6.5%, respectively; furthermore, the aRR was 1.35 (95% CI: 1.31-1.39). In patients underwent CT, the risk of AKI in the exposure group of contrast media increased compared with the control group and the aRR was 1.39 (95% CI: 1.09-1.78). However, it is not observed in patients underwent MRI (aRR: 1.36; 95% CI: 0.96-1.95). According to our subgroup analysis of pediatric patients aged ≥ 2 years (aRR: 1.38; 95% CI: 1.05-1.82) and sensitivity analysis (aRR: 1.32, 95% CI: 1.08-1.61), the risk of AKI in the exposure group was greater than that in the control group. An increased risk to exposure to contrast media was seen in females (aRR: 1.41, 95% CI: 1.05-1.89) rather than males (aRR: 1.30, 95% CI: 0.99-1.70). According to the multivariate logistic regression analyses, the baseline eGFR (OR: 1.02; 95% CI: 1.01-1.03) and comorbidities (OR: 2.97; 95% CI: 1.89-4.65) were risk factors, while age (OR: 0.87; 95% CI: 0.84-0.91) was a protective factor against AKI. CONCLUSION: The evidence from the present study suggested that the increased risk of AKI in hospitalized children induced by intravascular contrast should not be ignored.


Asunto(s)
Lesión Renal Aguda , Medios de Contraste , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/epidemiología , Medios de Contraste/efectos adversos , Masculino , Femenino , Preescolar , Niño , Estudios Retrospectivos , Lactante , China/epidemiología , Factores de Riesgo , Adolescente , Recién Nacido , Incidencia , Hospitalización
2.
J Xray Sci Technol ; 32(3): 513-528, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38393883

RESUMEN

OBJECTIVES: To evaluate the performance of deep learning image reconstruction (DLIR) algorithm in dual-energy spectral CT (DEsCT) as a function of radiation dose and image energy level, in comparison with filtered-back-projection (FBP) and adaptive statistical iterative reconstruction-V (ASIR-V) algorithms. METHODS: An ACR464 phantom was scanned with DEsCT at four dose levels (3.5 mGy, 5 mGy, 7.5 mGy, and 10 mGy). Virtual monochromatic images were reconstructed at five energy levels (40 keV, 50 keV, 68 keV, 74 keV, and 140 keV) using FBP, 50% and 100% ASIR-V, DLIR at low (DLIR-L), medium (DLIR-M), and high (DLIR-H) settings. The noise power spectrum (NPS), task-based transfer function (TTF) and detectability index (d') were computed and compared among reconstructions. RESULTS: NPS area and noise increased as keV decreased, with DLIR having slower increase than FBP and ASIR-V, and DLIR-H having the lowest values. DLIR had the best 40 keV/140 keV noise ratio at various energy levels, DLIR showed higher TTF (50%) than ASIR-V for all materials, especially for the soft tissue-like polystyrene insert, and DLIR-M and DLIR-H provided higher d' than DLIR-L, ASIR-V and FBP in all dose and energy levels. As keV increases, d' increased for acrylic insert, and d' of the 50 keV DLIR-M and DLIR-H images at 3.5 mGy (7.39 and 8.79, respectively) were higher than that (7.20) of the 50 keV ASIR-V50% images at 10 mGy. CONCLUSIONS: DLIR provides better noise containment for low keV images in DEsCT and higher TTF(50%) for the polystyrene insert over ASIR-V. DLIR-H has the lowest image noise and highest detectability in all dose and energy levels. DEsCT 50 keV images with DLIR-M and DLIR-H show potential for 65% dose reduction over ASIR-V50% withhigher d'.


Asunto(s)
Algoritmos , Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Relación Señal-Ruido , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Humanos
3.
Quant Imaging Med Surg ; 14(2): 1985-1993, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38415123

RESUMEN

Background: Multiphase contrast-enhanced computed tomography (CECT) is a commonly used modality in pediatric computed tomography (CT) scans. However, the purposes and focus of each phase, such as CT angiography (CTA), and parenchymal phase, are different. In routine practice, the same scanning parameters are used for all phases, resulting in unnecessary radiation exposure for children. Accurately and rapidly adjusting the scanning parameters for each phase of CECT is challenging in clinical settings. This retrospective cross-sectional study was designed to investigate the feasibility of using both CARE kV and CARE Dose 4D to reduce the radiation dose while maintaining diagnostic quality in multiphase CECT scans of children. Methods: Overall, 57 children (33 males and 24 females) who underwent multiphase abdominal CECT in Xinjiang Hospital of Beijing Children's Hospital with an average age of 6.52±4.30 years (range, 0.1-15 years), were enrolled. The tube voltage was automatically modulated using CARE kV. The tube current was automatically modulated using CARE Dose 4D. Different dose saving optimization indices (DI) were used for the three phases: a DI value of 3 was used for the unenhanced CT phase, a DI value of 12 was used for the CTA phase, and a DI value of 7 was used for the parenchymal phase. The tube voltage and volume CT dose index (CTDIvol) were recorded for each phase. Two reviewers subjectively evaluated the overall image quality and noise level of the three phases using a 5-point Likert scale (1-2 points: unqualified, 3 points: qualified, 4 points: better, 5 points: best). The CT and noise values of the descending aorta, liver, and back muscle were measured objectively. The voltage distribution and the image quality and CTDIvol in each phase were compared. Results: The most selected tube voltage in the unenhanced CT, CTA, and parenchymal phases was 100 kV (49/57, 85.96%), 70 kV (36/57, 63.16%), and 80 kV (32/57, 56.14%), respectively. The differences between the three phases were statistically significant (P<0.001). The CTDIvol values of the three phases were 3.99±1.99, 2.02±1.71, and 3.18±2.10 mGy, respectively, with a significant difference between the three phases (P<0.001). The CTDIvol decreased linearly as the DI value increased. All images met the diagnostic requirements. The overall quality scores for the three phases were 4.24±0.42, 4.41±0.49, and 4.50±0.45, respectively, with no significant linear relationship with the change in the DI. Conclusions: The combined use of CARE Dose 4D and CARE kV could effectively reduce the radiation dose in children during multiphase abdominal CECT without compromising the diagnostic image quality.

4.
Int Urol Nephrol ; 56(2): 373-380, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37833596

RESUMEN

OBJECTIVE: To describe and analyze the clinical manifestation and pre-DRF of UPJO children with polyps and explore the possible influencing factors of supranormal pre-DRF. PATIENTS AND METHODS: All patients undergoing primary Anderson-Hynes pyeloplasty for UPJO due to polyp were retrospectively reviewed. Patients' characteristics, parameters of ultrasound and dynamic renograms (DR) were recorded in elaborate. Pre-DRF in groups of different age, weight, gender, pain, grade of hydronephrosis, anterio-posterior pelvic diameter (APD), length of kidney and postoperative ultrasonic parameters were compared. RESULTS: A total of 18 UPJO children with polyps were included. Five (27.78%) patients had SFU III grade of hydronephrosis. Seven (38.89%) patients were supranormal pre-DRF. All patients had pre-DRF > 40%. Drainage curve was delayed excretion in 12 (66.67%) patients and T1/2 < 20 min was in 4 (22.22%) patients. Among the 16 patients who underwent preoperative IVP examination, 15 (93.75%) patients had concentration of intrarenal pelvis contrast agent within 10 min. No significant difference in post-APD reduction rate and post-minPT increased was found between supranormal pre-DRF and non-supranormal pre-DRF groups. The supranormal pre-DRF was more likely to occur in young and low-weight children. CONCLUSION: The preoperative renal function of UPJO patients with polyps was well preserved, and 38.89% of them had supranormal pre-DRF. Patients with supranormal pre-DRF can be managed with the same strategies as those with normal renal function.


Asunto(s)
Hidronefrosis , Obstrucción Ureteral , Niño , Humanos , Lactante , Pelvis Renal/diagnóstico por imagen , Pelvis Renal/cirugía , Estudios Retrospectivos , Obstrucción Ureteral/complicaciones , Obstrucción Ureteral/cirugía , Riñón/diagnóstico por imagen , Hidronefrosis/etiología , Hidronefrosis/cirugía , Resultado del Tratamiento
5.
J Neurosurg Pediatr ; 31(2): 99-108, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36446021

RESUMEN

OBJECTIVE: Pediatric patients are at risk of persistent hydrocephalus after posterior fossa tumor resection. The relationship between surgery-related factors and postoperative symptomatic hydrocephalus has not been elucidated. The objective of this study was to analyze features influencing postoperative hydrocephalus in Chinese children. METHODS: The authors retrospectively evaluated 197 patients younger than 15 years of age who underwent posterior fossa tumor resection at their institution from January 2015 to June 2021. The outcome was whether children underwent CSF diversion within 6 months of resection. Preoperative characteristics, surgery-related factors, and postoperative features were included to identify independent prognosticators. A new logistic model containing independent prognosticators was developed and compared with the modified Canadian Preoperative Prediction Rule for Hydrocephalus (mCPPRH). RESULTS: In this study, 30 patients (15.2%) underwent CSF diversion within 6 months after tumor resection. Tumor location and consistency, intracranial or spinal tumor metastasis determined by perioperative cerebral and spinal MRI, intraoperative blood loss, ventricular blood as determined on postoperative CT, and pathology were statistically significant variables in the univariate analysis. The only two independent predictors of postoperative symptomatic hydrocephalus were tumor metastasis (OR 3.463, 95% CI 1.137-10.549; p = 0.029) and postoperative ventricular blood (OR 4.212, 95% CI 1.595-11.122; p = 0.004). The final logistic model comprising tumor metastasis and postoperative ventricular blood was found to have better discrimination than the mCPPRH. CONCLUSIONS: Tumor characteristics and surgery-related features were associated with postoperative symptomatic hydrocephalus. Tumor metastasis and postoperative ventricular blood were found to be important prognosticators of persistent hydrocephalus.


Asunto(s)
Neoplasias Encefálicas , Hidrocefalia , Neoplasias Infratentoriales , Niño , Humanos , Estudios Retrospectivos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Canadá , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Neoplasias Infratentoriales/diagnóstico por imagen , Neoplasias Infratentoriales/cirugía , Hidrocefalia/diagnóstico por imagen , Hidrocefalia/etiología , Hidrocefalia/cirugía
6.
Artículo en Chino | MEDLINE | ID: mdl-36347578

RESUMEN

Objective:To review the clinical and radiological presentation and management of infected nasal dermal sinus cysts(NDSC) in children. Methods:Clinical data were collected from 59 NDSC children with secondary fronto-orbital area infection who presented to Beijing Children's Hospital from January 2007 to December 2021. All patients underwent preoperative imaging workup, including MRI and CT. All patients underwent endoscopic excision of a NDSC under general anesthesia. Results:A total of 59 patients were included in the study,while 58 presented with a sinus, 1 presented with a cyst.The main lesions of NDSC included nasal root in 20 cases (33.9%), nasal bridge in 34 cases (57.6%), nasal tip in 4 cases (6.8%), and nasal tip and nasal root in 1 case (1.7%). The depth of lesions included 6 cases (10.2%) of superficial type of nasal frontal bone, 33 cases (55.9%) of nasal frontal bone, 19 cases (32.2%) of intracranial epidural type, and 1 case (1.7%) of intracranial epidural type. The main sites of infection included inner canthus in 15 cases (25.4%), nasal dorsum in 22 cases (37.3%), nasal root in 16 cases (27.1%), and forehead in 6 cases (10.2%). Among 59 cases, 7 cases (11.9%) were complicated with other diseases, and 4 cases(6.8%) had external nasal deformities. Surgical approaches included transverse incision in 12 cases(20.3%), minimal midline vertical incision in 41 cases (69.5%), external rhinoplasty in 4 cases (6.8%) and bicoronal incision with vertical incision in 2 cases (3.4%). The range of lesions was completely consistent with MRI results.All cases were successfully operated without one-stage nasal dorsum reconstruction. All patients were followed up from 7 to 173 months(average 52.2 months). There were 6 cases of recurrence, all of which were in situ recurrence. The operation was performed again, and no recurrence has occurred since the follow-up, No nasal deformity was noted, and cosmetic outcome were favorable for all patients. Conclusion:NDSC infection in children with midfacial infection as the first symptom is rare in clinical practice, and its manifestations are diverse. Early diagnosis and rational treatment are very important to improve the cure rate.Preoperative high resolution MRI combined with CT scanning is of great significance in judging the course of NDSC, especially the intracranial extension. The treatment goal is to achieve minimally invasive and individualized treatment under the premise of complete excision of the lesion, and take into account the cosmetic needs.


Asunto(s)
Quiste Dermoide , Neoplasias Nasales , Enfermedades de los Senos Paranasales , Rinoplastia , Espina Bífida Oculta , Niño , Humanos , Quiste Dermoide/diagnóstico , Quiste Dermoide/patología , Quiste Dermoide/cirugía , Neoplasias Nasales/cirugía , Espina Bífida Oculta/cirugía , Enfermedades de los Senos Paranasales/cirugía
7.
J Pediatr Surg ; 57(12): 926-933, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35961818

RESUMEN

BACKGROUND: Cervical neuroblastic tumors (NTs) are rare but less aggressive cancer with an above-average survival rate. Little has been published regarding the management and surgical outcomes of patients with cervical NTs based on pathology category. This study compared and identified the preoperative characteristics of cervical NTs in different pathology categories and evaluated the outcomes of patients undergoing surgical resection. MATERIALS AND METHODS: Upon the institutional review board's approval, a retrospective chart review was performed at Beijing Children's Hospital from April 2013 to August 2020. Demographics of patients, imaging data, lab test results, operation details and outcomes were recorded and analyzed. RESULTS: Of 32 cervical NTs, 24(80%) were classified as neuroblastoma (NB) /ganglioneuroblastoma-nodular (GNBn) and 8(20%) as ganglioneuroblastoma-intermixed (GNBi)/ ganglioneuroma (GN). Patients with GNBi/GN were older than those with NB/GNBn (44.5 months (IQR 16-81) vs 9 months (IQR 1-47); P = 0.001). GNBi/GN patients presented more frequently with stage 1 disease compared with NB/GNBn patients (100% vs. 29.2%, P = 0.001), less frequently with tumor-related symptoms (0% vs. 70.8%, P = 0.001), artery encased tumor (0% vs. 41.7%, P = 0.035), and surgical complications (25% vs. 70.8%, P = 0.038). GNBi/GN patients were also less likely to show elevated neuron specific enolase (NSE) (12.5% vs. 79.2%, P = 0.002). CONCLUSIONS: Cervical NB/GNBn and GNBi/GN patients had distinct characteristic clinical presentations and surgical outcomes. For children with features suggestive of benign disease (older age, asymptomatic, normal serum tumor markers) and no artery image-defined risk factors (IDRFs), upfront resection can be considered.


Asunto(s)
Ganglioneuroblastoma , Ganglioneuroma , Neuroblastoma , Humanos , Niño , Ganglioneuroblastoma/diagnóstico por imagen , Ganglioneuroblastoma/cirugía , Estudios Retrospectivos , Ganglioneuroma/diagnóstico por imagen , Ganglioneuroma/cirugía , Neuroblastoma/cirugía , Resultado del Tratamiento
8.
BMC Surg ; 22(1): 295, 2022 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-35906560

RESUMEN

BACKGROUND: Benign splenic lesions are rarely encountered. This study aimed to review the clinical characteristics and surgical outcomes in a case series of 30 pediatric patients. METHODS: From January 1st, 2001 to December 31st, 2021, 30 pediatric patients from a single center were consecutively included. Electronic medical records were reviewed and patients were followed up. Clinical presentations, imaging features, surgical procedures, pathological diagnoses, and prognoses were summarized. The lesion locations and 7-day postoperative platelet levels were compared between total and partial splenectomy patients. RESULTS: Eighteen males and twelve females were included, with mean age at surgery 116.4 ± 43.6 months. The clinical presentations included abdominal pain (16/30), splenomegaly (6/30), skin petechia (2/30), hemolytic jaundice (1/30), and no symptoms (5/30). Pathological diagnoses included congenital epithelial cyst (CEC, 17/30), vascular malformation (8/30), sclerosing angiomatoid nodular transformation (SANT, 3/30), hamartoma (1/30), and leiomyoma (1/30). Patients undergone total splenectomy were more likely to have a lesion involving the hilum than those undergone partial splenectomy (68.4% vs 31.6%, P = 0.021). The 7-day postoperative platelet level was higher in total splenectomy patients than partial splenectomy patients (adjusted means 694.4 × 109/L vs 402.4 × 109/L, P = 0.002). CONCLUSIONS: Various clinical characteristics of pediatric benign splenic lesions are summarized. The most common pathological diagnoses are congenital epithelial cyst and vascular malformation. Partial and total splenectomy result in good prognosis with a low recurrence rate, and the former is preferred to preserve splenic function if possible.


Asunto(s)
Quistes , Enfermedades del Bazo , Malformaciones Vasculares , Niño , Femenino , Humanos , Masculino , Esplenectomía/métodos , Enfermedades del Bazo/cirugía
9.
Quant Imaging Med Surg ; 12(6): 3238-3250, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35655845

RESUMEN

Background: Studies on the application of deep learning image reconstruction (DLIR) in pediatric computed tomography (CT) are limited and have so far been mostly based on phantom. The purpose of this study was to compare the image quality and radiation dose of DLIR with that of adaptive statistical iterative reconstruction-Veo (ASiR-V) during abdominal and chest CT for the pediatric population. Methods: A pediatric phantom was used for the pilot study, and 20 children were recruited for clinical verification. The preset scan parameter noise index (NI) was 5, 8, 11, 13, 15, and 18 for the phantom study, and 8 and 13 for the clinical pediatric study. We reconstructed CT images with ASiR-V 30%, ASiR-V 70%, DLIR-M (medium) and DLIR-H (high). The regions of interest (ROI) were marked on the organs of the abdomen (liver, kidney, and subcutaneous fat) and the chest (lung, mediastinum, and spine). The CT dose index volume (CTDIvol), CT value, image noise (N), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured and calculated. The subjective image quality was assessed by 3 radiologists blindly using a 5-point scale. The dose reduction efficiency of DLIR was estimated. Results: In the phantom study, the interobserver assessment of the data measurement demonstrated good agreement [intraclass correlation coefficient (ICC) =0.814 for abdomen, 0.801 for chest]. Within the same dose level, the N, SNR, and CNR were statistically different among reconstructions, while the CT value remained the same. The N increased and SNR decreased as the radiation dose decreased. The DLIR-H performed better than ASiR-V when the radiation dose was reduced, without sacrificing image quality. In the patient study, the interobserver assessment of the data measurement demonstrated good agreement (ICC =0.774 for abdomen, 0.751 for chest). DLIR-H had the highest subjective and objective scores in the abdomen. Conclusions: Application of DLIR could help to reduce radiation dose without sacrificing the image quality of pediatric CT scans. Further clinical validation is required.

10.
Radiol Med ; 127(2): 154-161, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35034318

RESUMEN

BACKGROUND: Pulmonary embolism (PE) associated with Mycoplasma pneumoniae pneumonia (MPP) in children has already attracted more attention. CT pulmonary angiography (CTPA) has been the preferred method for diagnosing PE, but it has some limitations, especially for children. Dual-energy spectral CT has been used in diagnosing PE in adults. PURPOSE: To evaluate the application of dual-energy spectral CT in diagnosing PE in children with MPP. MATERIALS AND METHODS: Eighty-three children with MPP and highly suspected PE, underwent CTPA with spectral imaging mode, 25 children were diagnosis with PE. Noise, clot-to-artery contrast-to-noise ratio, image quality and diagnosis confidence were calculated and assessed on nine monochromatic image sets (40 to 80 keV). CTPA images were observed for the presence, localization and embolic degrees of PE. Clots were divided into intra- and extra-consolidation clots. For extra-consolidation clots, iodine concentration (IC) of perfusion defects and normal lung, perfusion defects of four children before and after the treatment were measured and compared. For intra-consolidation clots, IC of consolidation areas with clots and consolidation areas without clot were measured and compared. RESULTS: The optimal energy level for detecting PE in children was 55 keV. 116 clots (29 extra-consolidations) were found, IC of defect regions was 0.69 ± 0.28 mg/mL (extra-consolidations) and 0.90 ± 0.23 mg/mL (intra-consolidations), both significantly lower than the 2.76 ± 0.45 mg/mL in normal lungs and 10.25 ± 1.76 mg/mL in consolidations without clots (P < 0.001). Significant difference was found in the presence or absence of perfusion defects between occlusive clots and nonocclusive clots (P < 0.001). IC of the perfusion defects significantly increased after treatment (P < 0.001). CONCLUSIONS: In dual-energy spectral CTPA, 55 keV images optimize PE detection for children, and MD images quantify pulmonary blood flow of PE, and may help to detect small clots and quantify embolic degrees.


Asunto(s)
Neumonía por Mycoplasma/complicaciones , Neumonía por Mycoplasma/diagnóstico por imagen , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Niño , Preescolar , Femenino , Humanos , Masculino , Mycoplasma pneumoniae , Arteria Pulmonar/diagnóstico por imagen , Reproducibilidad de los Resultados
11.
J Xray Sci Technol ; 30(1): 177-184, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34806646

RESUMEN

BACKGROUND: The inflammatory indexes of children with Takayasu arteritis (TAK) usually tend to be normal immediately after treatment, therefore, CT angiography (CTA) has become an important method to evaluate the status of TAK and sometime is even more sensitive than laboratory test results. OBJECTIVE: To evaluate image quality improvement in CTA of children diagnosed with TAK using a deep learning image reconstruction (DLIR) in comparison to other image reconstruction algorithms. METHODS: hirty-two TAK patients (9.14±4.51 years old) underwent neck, chest and abdominal CTA using 100 kVp were enrolled. Images were reconstructed at 0.625 mm slice thickness using Filtered Back-Projection (FBP), 50%adaptive statistical iterative reconstruction-V (ASIR-V), 100%ASIR-V and DLIR with high setting (DLIR-H). CT number and standard deviation (SD) of the descending aorta and back muscle were measured and contrast-to-noise ratio (CNR) for aorta was calculated. The vessel visualization, overall image noise and diagnostic confidence were evaluated using a 5-point scale (5, excellent; 3, acceptable) by 2 observers. RESULTS: There was no significant difference in CT number across images reconstructed using different algorithms. Image noise values (in HU) were 31.36±6.01, 24.96±4.69, 18.46±3.91 and 15.58±3.65, and CNR values for aorta were 11.93±2.12, 15.66±2.37, 22.54±3.34 and 24.02±4.55 using FBP, 50%ASIR-V, 100%ASIR-V and DLIR-H, respectively. The 100%ASIR-V and DLIR-H images had similar noise and CNR (all P > 0.05), and both had lower noise and higher CNR than FBP and 50%ASIR-V images (all P < 0.05). The subjective evaluation suggested that all images were diagnostic for large arteries, however, only 50%ASIR-V and DLIR-H met the diagnostic requirement for small arteries (3.03±0.18 and 3.53±0.51). CONCLUSION: DLIR-H improves CTA image quality and diagnostic confidence for TAK patients compared with 50%ASIR-V, and best balances image noise and spatial resolution compared with 100%ASIR-V.


Asunto(s)
Aprendizaje Profundo , Arteritis de Takayasu , Adolescente , Algoritmos , Niño , Preescolar , Angiografía por Tomografía Computarizada , Humanos , Procesamiento de Imagen Asistido por Computador , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Arteritis de Takayasu/diagnóstico por imagen
12.
Quant Imaging Med Surg ; 11(9): 4162-4171, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34476196

RESUMEN

BACKGROUND: Iterative reconstruction algorithms are often used to reduce image noise in low-dose coronary computed tomography angiography (CCTA) but encounter limitations. The newly introduced deep learning image reconstruction (DLIR) algorithm may provide new opportunities. We assessed the image quality and diagnostic performance of DLIR in low radiation dose and contrast medium dose CCTA of pediatric patients with 70 kVp and a shortened injection protocol. METHODS: This was a prospective study. A total of 27 consecutive arrhythmic pediatric patients were enrolled in the study group and underwent CCTA using a prospective ECG-triggered single-beat protocol: tube voltage 70 kVp, automatic tube current modulation for a noise index (NI) of 22, and contrast dose of 0.4-0.6 mL/kg. Images were reconstructed with DLIR. They were compared with 27 matched patients in the control group scanned with 80 kVp, a lower NI setting (NI =19), and a higher contrast dose (0.8-1.2 mL/kg). The images in the control group were reconstructed using the adaptive statistical iterative reconstruction (ASIR-V) algorithm. The image contrast, image quality, and diagnostic confidence were assessed by 2 experienced radiologists using a 5-point scale (1: nondiagnostic and 5: excellent). The CT value and standard deviation of the aorta and perivascular tissue were measured, and the contrast-to-noise ratio (CNR) for the aorta was calculated. The contrast medium and radiation doses were compared. RESULTS: The study and control groups had similar image contrast scores (4.75±0.57 vs. 4.78±0.42), image quality scores (3.67±0.47 vs. 3.44±0.51), and diagnostic confidence (4.74±0.44 vs. 4.74±0.45) (all P>0.05). There was an adequate enhancement in the aorta (614.74±127.73 vs. 705.89±111.20 HU) and similar CNR (20.34±4.64 vs. 20.99±4.14) in both groups. The image noise of the study group was lower in the aorta (30.61±3.88 vs. 34.77±3.49) and similar in perivascular tissue (27.66±6.24 vs. 27.55±3.33) compared with the control group. The study group reduced the total contrast medium dose by 53% to 15.07±3.68 mL and radiation dose by 36% to 0.57±0.31 mSv. CONCLUSIONS: The DLIR algorithm in CCTA for children using 70 kVp tube voltage with a shortened contrast medium injection protocol maintains image quality and diagnostic confidence while significantly reducing contrast medium dose and radiation dose compared with the use of the conventional CCTA protocol.

13.
BMC Med Imaging ; 21(1): 108, 2021 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-34238229

RESUMEN

BACKGROUND: To evaluate the performance of a Deep Learning Image Reconstruction (DLIR) algorithm in pediatric head CT for improving image quality and lesion detection with 0.625 mm thin-slice images. METHODS: Low-dose axial head CT scans of 50 children with 120 kV, 0.8 s rotation and age-dependent 150-220 mA tube current were selected. Images were reconstructed at 5 mm and 0.625 mm slice thickness using Filtered back projection (FBP), Adaptive statistical iterative reconstruction-v at 50% strength (50%ASIR-V) (as reference standard), 100%ASIR-V and DLIR-high (DL-H). The CT attenuation and standard deviation values of the gray and white matters in the basal ganglia were measured. The clarity of sulci/cisterns, boundary between white and gray matters, and overall image quality was subjectively evaluated. The number of lesions in each reconstruction group was counted. RESULTS: The 5 mm FBP, 50%ASIR-V, 100%ASIR-V and DL-H images had a subjective score of 2.25 ± 0.44, 3.05 ± 0.23, 2.87 ± 0.39 and 3.64 ± 0.49 in a 5-point scale, respectively with DL-H having the lowest image noise of white matter at 2.00 ± 0.34 HU; For the 0.625 mm images, only DL-H images met the diagnostic requirement. The 0.625 mm DL-H images had similar image noise (3.11 ± 0.58 HU) of the white matter and overall image quality score (3.04 ± 0.33) as the 5 mm 50% ASIR-V images (3.16 ± 0.60 HU and 3.05 ± 0.23). Sixty-five lesions were recognized in 5 mm 50%ASIR-V images and 69 were detected in 0.625 mm DL-H images. CONCLUSION: DL-H improves the head CT image quality for children compared with ASIR-V images. The 0.625 mm DL-H images improve lesion detection and produce similar image noise as the 5 mm 50%ASIR-V images, indicating a potential 85% dose reduction if current image quality and slice thickness are desired.


Asunto(s)
Encefalopatías/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Traumatismos Craneocerebrales/diagnóstico por imagen , Aprendizaje Profundo , Tomografía Computarizada Multidetector/métodos , Adolescente , Algoritmos , Lesiones Encefálicas/diagnóstico por imagen , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Exposición a la Radiación/prevención & control , Estudios Retrospectivos , Relación Señal-Ruido
14.
Quant Imaging Med Surg ; 11(7): 3051-3058, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34249634

RESUMEN

BACKGROUND: Chest CT angiography (CTA) is a common clinical examination technique for children. Iterative reconstruction algorithms are often used to reduce image noise but encounter limitations under low dose conditions. Deep learning-based image reconstruction algorithms have been developed to overcome these limitations. We assessed the quantitative and qualitative image quality of thin-slice chest CTA in children acquired with low radiation dose and contrast volume by using a deep learning image reconstruction (DLIR) algorithm. METHODS: A total of 33 children underwent chest CTA with 70 kVp and automatic tube current modulation for noise indices of 11-15 based on their age and contrast volume of 0.8-1.2 mL/kg. Images were reconstructed with 50% and 100% adaptive statistical iterative reconstruction-V (ASIR-V) and high-setting DLIR (DLIR-H) at 0.625 mm slice thickness. Two radiologists evaluated images in consensus for overall image noise, artery margin, and artery contrast separately on a 5-point scale (5, excellent; 4, good; 3, acceptable; 2, sub-acceptable, and 1, not acceptable). The CT value and image noise of the descending aorta and back muscle were measured. Radiation dose and contrast volume was recorded. RESULTS: The volume CT dose index, dose length product, and contrast volume were 1.37±0.29 mGy, 35.43±10.59 mGy·cm, and 25.43±13.32 mL, respectively. The image noises (in HU) of the aorta with DLIR-H (19.24±5.77) and 100% ASIR-V (20.45±6.93) were not significantly different (P>0.05) and were substantially lower than 50% ASIR-V (29.45±7.59) (P<0.001). The 100% ASIR-V images had over-smoothed artery margins, but only the DLIR-H images provided acceptable scores on all 3 aspects of the qualitative image quality evaluation. CONCLUSIONS: It is feasible to improve the image quality of a low radiation dose and contrast volume chest CTA in children using the high-setting DLIR algorithm.

15.
Radiol Med ; 126(9): 1181-1188, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34132926

RESUMEN

BACKGROUND: Chest CT angiography (CTA) is a convenient clinical examination for children with an increasing need to reduce both radiation and contrast medium doses. Iterative Reconstruction algorithms are often used to reduce image noise but encounter limitations under low radiation dose and conventional 100 kVp tube voltage may not provide adequate enhancement under low contrast dose. PURPOSE: To evaluate the performance of a deep learning image reconstruction (DLIR) algorithm in conjunction with lower tube voltage in chest CTA in children under reduced radiation and contrast medium (CM) dose. MATERIALS AND METHODS: 46 Children (age 5.9 ± 4.2 years) in the study group underwent chest CTA with 70 kVp and CM dose of 0.8-1.2 ml/kg. Images were reconstructed at 0.625 mm using a high setting DLIR (DLIR-H). The control group consisted of 46 age-matching children scanned with 100 kVp, CM dose of 1.3-1.8 ml/kg and images reconstructed with 50% and 100% adaptive statistical iterative reconstruction-V. Two radiologists evaluated images subjectively for overall image noise, vessel contrast and vessel margin clarity separately on a 5-point scale (5, excellent and 1, not acceptable). CT value and image noise of aorta and erector spinae muscle were measured. RESULTS: Compared to the control group, the study group reduced the dose-length-product by 11.2% (p = 0.01) and CM dose by 24% (p < 0.001), improved the enhancement in aorta (416.5 ± 113.1HU vs. 342.0 ± 57.6HU, p < 0.001) and reduced noise (15.1 ± 3.5HU vs. 18.6 ± 4.4HU, p < 0.001). The DLIR-H images provided acceptable scores on all 3 aspects of the qualitative evaluation. CONCLUSION: "Double low" chest CTA in children using 70 kVp and DLIR provides high image quality with reduced noise and improved vessel enhancement for diagnosis while further reduces radiation and CM dose.


Asunto(s)
Angiografía por Tomografía Computarizada , Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador/métodos , Tórax/diagnóstico por imagen , Adolescente , Algoritmos , Estudios de Casos y Controles , Niño , Preescolar , Estudios de Factibilidad , Femenino , Humanos , Lactante , Masculino , Estudios Prospectivos
16.
J Xray Sci Technol ; 29(5): 813-821, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34151881

RESUMEN

BACKGROUND: Low-tube voltage scanning improves CT attenuation value of contrast medium (CM). Thus, we hypothesized that 70 kVp in pediatric abdominal CT angiography (CTA) could be used to reduce both radiation and CM dose and improve patient comfort at the same time. OBJECTIVE: To evaluate the feasibility of using 70 kVp in pediatric abdominal CTA to reduce radiation dose and CM dose and improve patient care for children. MATERIALS AND METHODS: Forty-six children needing abdominal CTA were enrolled in the study group using low-dose scanning protocol with 70 kVp and 0.7-1.1 ml/kg contrast dose, and reconstructed with 50%ASIR-V. They were compared with other 46 children in control group with matching body weight and underwent conventional CT scans with 100 kVp, 1.2-1.8 ml/kg contrast dose and reconstructed using 50%ASIR. Image quality of large vessels was evaluated using a 5-point scale. CT value and standard deviation of descending aorta (Ao) was measured, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Radiation dose, contrast dose, the maximum injection pressure between the two groups were also compared. RESULTS: Score for displaying large vessels by 70 kVp images was 3.91±0.28, lower than that (4.17±0.38) of the control group (p < 0.05), but fully met the diagnostic requirements. CT value of Ao was 390.87±86.79HU in study group, which is higher than 343.93±49.94HU in control group, while there was no difference in SNR and CNR between two groups; the radiation dose, contrast dosage and injection pressure of the study group were 1.23±0.39mGy, 12.67±7.27 ml and 43.83±17.16psi, respectively, which are significantly lower than the 1.95±0.37mGy, 22.67±7.39 ml, and 77.59±19.68psi of control group. CONCLUSION: Use of 70 kVp in pediatric abdominal CTA provides diagnostic quality images while significantly reduce radiation and contrast dose, as well as injection pressure to improve patient comfort for children.


Asunto(s)
Angiografía por Tomografía Computarizada , Comodidad del Paciente , Peso Corporal , Niño , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste , Humanos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Relación Señal-Ruido
18.
Acta Otolaryngol ; 141(3): 250-255, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33502272

RESUMEN

BACKGROUND: We are inclined to pay special care and attention to children with large vestibular aqueduct syndrome (LVAS). However, it is not clear whether children with LVAS have more developmental delays than children without LVAS. OBJECTIVES: To compare the developmental performance between pediatric cochlear implantation (CI) candidates with and without LVAS. MATERIALS AND METHODS: Medical records of pediatric CI candidates were reviewed. Through propensity score matching analysis, 70 children with LVAS and 70 gender-, age-, and auditory-matched children were recruited as the LVAS and non-LVAS group, respectively. Developmental performances were compared between the two groups. RESULTS: Compared with normal developmental metrics, both LVAS and non-LVAS groups had developmental delay in multiple domains (both p < .001). Although some differences in motor developments between children with LVAS and without LVAS, they demonstrated overall equal developmental levels in both verbal and nonverbal aspects (all p > .05). Age of intervention was the primary risk factor for developmental performance of LVAS children (ß < 0, p < .05) with an obvious delay starting at 1 year of age. CONCLUSION: Pediatric CI candidates with LVAS had both verbal and nonverbal developmental delays. However, they exhibited similar overall developmental performances to those without LVAS.


Asunto(s)
Implantes Cocleares , Discapacidades del Desarrollo/etiología , Acueducto Vestibular/anomalías , Enfermedades Vestibulares/complicaciones , Umbral Auditivo , Niño , Preescolar , Estudios Transversales , Femenino , Pérdida Auditiva Sensorineural/etiología , Pérdida Auditiva Sensorineural/rehabilitación , Pruebas Auditivas , Humanos , Lactante , Modelos Lineales , Masculino , Destreza Motora , Puntaje de Propensión , Estudios Retrospectivos
19.
BMC Pediatr ; 20(1): 499, 2020 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-33126876

RESUMEN

BACKGROUND: Preoperative diagnosis of total colonic aganglionosis is important for the rational choice of treatment. The present study aimed to evaluate the diagnostic performance of radiographic signs on preoperative barium enema in patients with total colonic aganglionosis. METHODS: Forty-four patients [41 (3-659) days] with total colonic aganglionosis, including 17 neonatal patients, who received preoperative barium enema at Beijing Children's Hospital, from January 2007 to December 2019 were included. All radiographs were retrospectively restudied by 2 pediatric radiologists to ascertain radiographic signs including rectosigmoid index, transition zone, irregular contraction, gas-filled small bowel, microcolon, question-mark-shaped colon and ileocecal valve reflux. Kappa test was performed to assess the accuracy and consistency of the radiographic signs. RESULTS: The 2 radiologists showed slight agreement for gas-filled small bowel, microcolon and rectosigmoid index, fair agreement for transition zone and irregular contraction, and moderate agreement for question-mark-shaped colon and ileocecal valve reflux (Kappa values, 0.043, 0.075, 0.103, 0.244, 0.397, 0.458 and 0.545, respectively). In neonatal patients, the 2 radiologists showed moderate agreement for ileocecal valve reflux and substantial agreement for question-mark-shaped colon (Kappa values, 0.469 and 0.667, respectively). In non-neonatal patients, the 2 radiologists showed substantial agreement for ileocecal valve reflux (Kappa value, 0.628). In 36 patients with total colonic aganglionosis extending to the ileum, the accuracies of question-mark-shaped colon, ileocecal valve reflux and the combination of both were 47%, 53%, and 75%, respectively, in one radiologist and 53%, 50% and 72%, respectively, in the other radiologist. CONCLUSIONS: Ileocecal valve reflux is a relatively reliable radiographic sign for diagnosing total colonic aganglionosis and could improve the diagnostic accuracy upon combination with question-mark-shaped colon.


Asunto(s)
Enfermedad de Hirschsprung , Enema Opaco , Niño , Enema , Enfermedad de Hirschsprung/diagnóstico por imagen , Humanos , Recién Nacido , Estudios Retrospectivos
20.
J Comput Assist Tomogr ; 44(5): 790-795, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32936580

RESUMEN

BACKGROUND: The state-of-art motion correction algorithm is inadequate for correcting motion artifacts in coronary arteries in cardiovascular computed tomography angiography (CCTA) for children with high heart rates, and even less effective for heart structures beyond coronary arteries. PURPOSE: This study aimed to evaluate the effectiveness of a second-generation, whole-heart motion correction algorithm in improving the heart image quality of CCTA for children with high heart rates. MATERIALS AND METHODS: Forty-two consecutive symptomatic cardiac patients with high heart rates (122.6 ± 18.8 beats/min) were enrolled. All patients underwent CCTA on a 256-row CT using a prospective electrocardiogram-triggered single-beat protocol. Images were reconstructed using a standard algorithm (STD), state-of-the-art first-generation coronary artery motion correction algorithm (MC1), and second-generation, whole-heart motion correction algorithm (MC2). The image quality of the origin of left coronary, right coronary, aortic valve, pulmonary valve, mitral valve, tricuspid valve, aorta root, pulmonary artery root, ventricular septum (VS), and atrial septum (AS) was assessed by 2 experienced radiologists using a 4-point scale (1, nondiagnostic; 2, detectable; 3, measurable; and 4, excellent); nonparametric test was used to analyze and compare the differences among 3 groups; and post hoc multiple comparisons were used between different methods. RESULTS: There were group differences for cardiac structures except VS and AS, with MC2 having the best image quality and STD having the worst image quality. Post hoc multiple comparisons showed that MC2 was better than MC1 and STD in all structures except VS and AS where all 3 algorithms performed equally, whereas MC1 was better than STD only in the origin of left coronary, right coronary, and mitral valve. CONCLUSIONS: A second-generation, whole-heart motion correction algorithm further significantly improves cardiac image quality beyond the coronaries in CCTA for pediatric patients with high heart rates.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Frecuencia Cardíaca/fisiología , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Algoritmos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...