Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Insights Imaging ; 14(1): 149, 2023 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-37726452

RESUMEN

BACKGROUND: The deep learning-based nodule detection (DLD) system improves nodule detection performance of observers on chest radiographs (CXRs). However, its performance in different pulmonary nodule (PN) locations remains unknown. METHODS: We divided the CXR intrathoracic region into non-danger zone (NDZ) and danger zone (DZ). The DZ included the lung apices, paramediastinal areas, and retrodiaphragmatic areas, where nodules could be missed. We used a dataset of 300 CXRs (100 normal and 200 abnormal images with 216 PNs [107 NDZ and 109 DZ nodules]). Eight observers (two thoracic radiologists [TRs], two non-thoracic radiologists [NTRs], and four radiology residents [RRs]) interpreted each radiograph with and without the DLD system. The metric of lesion localization fraction (LLF; the number of correctly localized lesions divided by the total number of true lesions) was used to evaluate the diagnostic performance according to the nodule location. RESULTS: The DLD system demonstrated a lower LLF for the detection of DZ nodules (64.2) than that of NDZ nodules (83.2, p = 0.008). For DZ nodule detection, the LLF of the DLD system (64.2) was lower than that of TRs (81.7, p < 0.001), which was comparable to that of NTRs (56.4, p = 0.531) and RRs (56.7, p = 0.459). Nonetheless, the LLF of RRs significantly improved from 56.7 to 65.6 using the DLD system (p = 0.021) for DZ nodule detection. CONCLUSION: The performance of the DLD system was lower in the detection of DZ nodules compared to that of NDZ nodules. Nonetheless, RR performance in detecting DZ nodules improved upon using the DLD system. CRITICAL RELEVANCE STATEMENT: Despite the deep learning-based nodule detection system's limitations in detecting danger zone nodules, it proves beneficial for less-experienced observers by providing valuable assistance in identifying these nodules, thereby advancing nodule detection in clinical practice. KEY POINTS: • The deep learning-based nodule detection (DLD) system can improve the diagnostic performance of observers in nodule detection. • The DLD system shows poor diagnostic performance in detecting danger zone nodules. • For less-experienced observers, the DLD system is helpful in detecting danger zone nodules.

2.
Respir Res ; 24(1): 179, 2023 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-37420251

RESUMEN

PURPOSE: To address the limited utility of the interferon (IFN)-γ release assay (IGRA) caused by its variability and inconsistency. METHODS: This retrospective cohort study was based on data obtained between 2011 and 2019. QuantiFERON-TB Gold-In-Tube was used to measure IFN-γ levels in nil, tuberculosis (TB) antigen, and mitogen tubes. RESULTS: Of 9,378 cases, 431 had active TB. The non-TB group comprised 1,513 IGRA-positive, 7,202 IGRA-negative, and 232 IGRA-indeterminate cases. Nil-tube IFN-γ levels were significantly higher in the active TB group (median = 0.18 IU/mL; interquartile range: 0.09-0.45 IU/mL) than in the IGRA-positive non-TB (0.11 IU/mL; 0.06-0.23 IU/mL) and IGRA-negative non-TB (0.09 IU/mL; 0.05-0.15 IU/mL) groups (P < 0.0001). From receiver operating characteristic analysis, TB antigen tube IFN-γ levels had higher diagnostic utility for active TB than TB antigen minus nil values. In a logistic regression analysis, active TB was the main driver of higher nil values. In the active TB group, after reclassifying the results based on a TB antigen tube IFN-γ level of 0.48 IU/mL, 14/36 cases with negative results and 15/19 cases with indeterminate results became positive, while 1/376 cases with positive results became negative. Overall, the sensitivity for detecting active TB improved from 87.2 to 93.7%. CONCLUSION: The results of our comprehensive assessment can aid in IGRA interpretation. Since nil values are governed by TB infection rather than reflecting background noise, TB antigen tube IFN-γ levels should be used without subtracting nil values. Despite indeterminate results, TB antigen tube IFN-γ levels can be informative.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis , Humanos , Ensayos de Liberación de Interferón gamma/métodos , Mitógenos , Estudios Retrospectivos , Tuberculosis/diagnóstico
3.
Korean J Radiol ; 24(8): 807-820, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37500581

RESUMEN

OBJECTIVE: To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software. MATERIALS AND METHODS: This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1-7 according to acquisition conditions. CT images in groups 2-7 were converted into the target CT style (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system. RESULTS: Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2-7 improved after CT conversion (original vs. converted: 0.63 vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists' scores were significantly higher (P < 0.001) and less variable on converted CT. CONCLUSION: CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.


Asunto(s)
Enfisema , Enfermedades Pulmonares Intersticiales , Enfisema Pulmonar , Femenino , Humanos , Persona de Mediana Edad , Anciano , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Pulmón/diagnóstico por imagen
4.
Sci Rep ; 12(1): 15682, 2022 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-36127437

RESUMEN

This study aimed to assess the diagnostic accuracy and safety of CT-guided percutaneous core needle biopsy (PCNB) with a coaxial needle for the diagnosis of lung cancer in patients with an usual interstitial pneumonia (UIP) pattern of interstitial lung disease. This study included 70 patients with UIP and suspected to have lung cancer. CT-guided PCNB was performed using a 20-gauge coaxial cutting needle. The diagnostic accuracy, sensitivity, specificity, and percentage of nondiagnostic results for PCNB were determined in comparison with the final diagnosis. PCNB-related complications were evaluated. Additionally, the risk factors for nondiagnostic results and pneumothorax were analyzed. The overall diagnostic accuracy, sensitivity, and specificity were 85.7%, 85.5%, and 87.5%, respectively. The percentage of nondiagnostic results was 18.6% (13/70). Two or less biopsy sampling was a risk factor for nondiagnostic results (p = 0.003). The overall complication rate was 35.7% (25/70), and pneumothorax developed in 22 patients (31.4%). A long transpulmonary needle path was a risk factor for the development of pneumothorax (p = 0.007). CT-guided PCNB using a coaxial needle is an effective method with reasonable accuracy and an acceptable complication rate for the diagnosis of lung cancer, even in patients with UIP.


Asunto(s)
Fibrosis Pulmonar Idiopática , Neoplasias Pulmonares , Neumotórax , Biopsia con Aguja Gruesa , Humanos , Fibrosis Pulmonar Idiopática/patología , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Pulmón/diagnóstico por imagen , Pulmón/patología , Neoplasias Pulmonares/patología , Nitrobencenos , Neumotórax/etiología , Neumotórax/patología , Tomografía Computarizada por Rayos X/métodos
5.
Thorac Cancer ; 13(12): 1866-1869, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35491544

RESUMEN

Ciliated muconodular papillary tumor (CMPT) is a rare benign lung tumor characterized by ciliated columnar cells, mucous cells, and basal cells. Herein, we report a case of CMPT with 11 years of preoperative follow-up, depicting the natural course of the tumor and changes in computed tomography (CT) findings. A 39-year-old man had a 5-mm solid pulmonary nodule in the right lower lobe that had slowly grown and transformed into a thin-walled cavitary lesion. Right lower lobe lobectomy was performed and the tumor was confirmed to be a CMPT. Although it is difficult to diagnose CMPT with CT findings alone, CMPT should be considered as a possible diagnosis when a slowly growing nodule undergoes cavitary changes.


Asunto(s)
Neoplasias Pulmonares , Adulto , Células Epiteliales/patología , Estudios de Seguimiento , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Masculino , Tomografía Computarizada por Rayos X
6.
Artículo en Inglés | MEDLINE | ID: mdl-34360313

RESUMEN

The diagnosis of tuberculous lymphadenitis (TB-LAP) is challenging. We evaluated the role of blood CXC chemokine receptor 3 (CXCR3) ligands in its diagnosis. A total of 65 lymphadenopathy patients were enrolled and lymph node sampling was performed. We also recruited 113 control subjects, consisting of 27 with positive results and 86 with negative results, in the interferon (IFN)-γ release assay (IGRA). In all study subjects, whole-blood samples were collected using the IGRA methodology. After incubation, plasma levels of IFN-γ and two CXCR3 ligands, IFN-inducible T-cell a chemoattractant (I-TAC) and monokine induced by IFN-γ (MIG), were measured using immunoassay. Fifty-three TB-LAP patients were enrolled. TB antigen-stimulated IFN-γ, I-TAC, and MIG levels were all significantly higher in the TB-LAP patients than in the controls and non-TB-LAP patients. The levels of I-TAC and MIG, but not IFN-γ, showed significant differences between the TB-LAP patients and IGRA-positive controls. Area under the receiver operating characteristic curves (AUROCs) of IFN-γ, I-TAC, and MIG were 0.955, 0.958, and 0.959, respectively, for differentiating TB-LAP from control group, and were 0.912, 0.956, and 0.936, respectively, for differentiating TB-LAP from non-TB-LAP. In conclusion, the TB antigen-stimulated MIG and I-TAC could be useful biomarkers in the diagnosis of TB-LAP.


Asunto(s)
Receptores CXCR3 , Tuberculosis Ganglionar , Humanos , Interferón gamma , Ligandos , Curva ROC , Tuberculosis Ganglionar/diagnóstico
7.
J Clin Med ; 10(5)2021 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-33668933

RESUMEN

The aim of this study is to investigate the clinical utility of staging chest CT in breast cancer by evaluating diagnostic yield (DY) of chest CT in detection of metastasis, according to the molecular subtype and clinical stage. This retrospective study included 840 patients with 855 breast cancers from January 2017 to December 2018. The number of patients in clinical stage 0/I, II, III and IV were 457 (53.5%), 298 (34.9%), 92 (10.8%) and 8 (0.9%), respectively. Molecular subtype was identified in 841 cancers and there were 709 (84.3%) luminal type, 55 (6.5%) human epidermal growth factor receptor 2 (HER2)-enriched type and 77 (9.2%) triple-negative (TN) type. The DYs in clinical stage 0/I, cII, cIII and cIV were 0.2% (1/457), 1.7% (5/298), 4.3% (4/92) and 100.0% (8/8), respectively. The DYs in luminal type, HER2-enriched type and TN type were 1.7% (12/709), 3.6% (2/55) and 2.6% (2/77), respectively. Clinical stage was associated with the DY (p = 0.000). However, molecular subtype was not related to the DY (p = 0.343). Molecular subtype could not provide useful information to determine whether staging chest CT should be performed in early-stage breast cancer. However, chest CT should be considered in advanced breast cancer.

8.
Sci Rep ; 10(1): 9186, 2020 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-32514056

RESUMEN

We evaluated the clinical utility of early postoperative cardiac computed tomography (CT) for evaluating left ventricular (LV) function and predicting prognosis in patients who had undergone coronary artery bypass grafting (CABG). Of the 205 patients who underwent CABG from March 2011 to December 2014, 136 underwent early postoperative cardiac CT (within 30 days after CABG) and were enrolled as the study population. The baseline and postoperative follow-up echocardiographic findings, major adverse cardiac events (MACE), and death were recorded for a follow-up period (mean, 5.9 ± 1.1 years). Functional cardiac CT parameters were compared to echocardiographic measurements. The associations between cardiac CT findings and functional recovery and prognosis were evaluated by logistic regression analyses. The LVEF measured via cardiac CT was significantly higher (56.2 ± 11.5% vs. 61.9 ± 12.9%; p = 0.0002) compared to those via early postoperative echocardiography, but the wall motion score index (WMSI) was not significantly different (1.23 ± 0.33 vs. 1.21 ± 0.28, p = 0.5041) between the two methods. During the follow-up period, 17 patients (12.5%) died and 40 (29.4%) developed MACE. Both the LVEF and WMSI measured with early postoperative echocardiography (p = 0.0202 and odds ratio [OR] = 5.0171, p = 0.0039, respectively), and cardiac CT (OR = 0.9625, p = 0.0091 and OR = 14.3605, p = 0.0001, respectively) predicted MACE OR = 0.9630, but only the WMSI, measured using cardiac CT, predicted all-cause death (OR = 10.6017, p = 0.0035). In CABG patients, LVEF and the WMSI measured with early postoperative cardiac CT were comparable with echocardiography and predicted the development of MACE and all-cause death.


Asunto(s)
Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Corazón/fisiopatología , Función Ventricular Izquierda/fisiología , Puente de Arteria Coronaria/métodos , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Periodo Posoperatorio , Pronóstico , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/cirugía
9.
Taehan Yongsang Uihakhoe Chi ; 81(4): 990-995, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36238165

RESUMEN

Chronic granulomatous disease (CGD) is an uncommon primary immune deficiency caused by phagocytes defective in oxygen metabolite production. It results in recurrent bacterial or fungal infections. Herein, we present a case of CGD with a large pulmonary granuloma in a neonate and review the imaging findings. The patient was a 24-day-old neonate admitted to the hospital with fever. A round opacified lesion was identified on the chest radiograph. Subsequent CT and MRI revealed a round mass with heterogeneous enhancement in the right lower lobe. There were foci of diffusion restriction in the mass. Surgical biopsy of the mass revealed chronic granuloma. Finally, the neonate was diagnosed with CGD caused by mutation of the gp91phox gene. Herein, we present the clinical and imaging findings of this unusual case of CGD.

10.
Clin Nutr ; 38(6): 2747-2755, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-30612851

RESUMEN

BACKGROUND: We compared the evaluation of skeletal muscle mass (SMM) using the computed tomography (CT) and bioelectrical impedance analysis (BIA) methods in critically ill patients. We also evaluated whether BIA can be applied for measuring SM with high accuracy to critically ill patients. METHODS: We included 135 critically ill surgical patients (83 men and 52 women, mean age: 59.3 years) who got the BIA and abdominal CT scan both within 7 days during the intensive care unit (ICU) stay. With CT scan, skeletal muscle area (SMA) measured from the L3 spine level image was used for calculation of the whole body skeletal muscle volume and mass (kg). Body composition data from BIA were obtained using touch-type electrodes and 50 kHz current. Subgroup analyses for SMM were performed according to the sex, SMA, and edema status of the patients with Pearson correlation or regression analysis et al. RESULTS: SMM from CT and BIA showed a good correlation (p < 0.0001) to sex, SMA, and edema in the subgroup analysis. A stronger correlation was noted between SMM from CT and BIA in male patients or mild edema group than for the other groups. SMM from BIA showed greater values than that from CT (mean difference, 3.35 kg) in all groups, except the normal SMA (higher than 170 cm2 in men, and 110 cm2 in women) group. Male patients and mild edema group showed more SMM as evaluated by BIA when compared to the other groups. CONCLUSION: SMM measure by BIA in critically ill patients showed high correlation with SMM calculation by CT scan and had greater values than SMM from CT scan. TRIAL REGISTRATION: Ajou University Hospital Institutional Review Board DEV-DE4-15-115, Registered Jan 1 2015.


Asunto(s)
Composición Corporal/fisiología , Enfermedad Crítica/epidemiología , Impedancia Eléctrica , Músculo Esquelético , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adulto , Anciano , Animales , Antropometría , Edema , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiología
11.
Eur Radiol ; 29(8): 4324-4332, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30617475

RESUMEN

PURPOSE: To assess the ability of digital chest radiography (CXR) to reveal calcification in solitary pulmonary nodules (SPNs), and to examine the correlation between a visual assessment and volumetric quantification of the calcification. MATERIALS AND METHODS: This study was a retrospective review of 220 SPNs identified by both CXR and chest CT. Eleven observers did blind review of the CXR images and scored nodule calcification on a confidence scale of 1 to 5. The area under the receiver operating characteristics (ROC) curve (AUC) was obtained to analyze the diagnostic performance. The intraclass correlation coefficient (ICC) for interrater reliability was calculated. The AUC and ICC were calculated according to the following nodule diameter groups: group 1 (< 10 mm), group 2 (≥ 10 mm and < 20 mm), and group 3 (≥ 20 mm). RESULTS: Of the 220 SPNs, 145 SPNs (65.6%) were identified as non-calcified and 75 (34.4%) as calcified. The average percentage of calcification volume in SPN > 160 HU (Vol160HU) among the 75 calcified nodules was 47.5%. The mean Vol160HU of the 68 SPNs classified as having definite calcification was 51.1%. The overall AUC was 0.71. The AUCs for groups 1, 2, and 3 was 0.835, 0.639, and 0.620, respectively. The ICCs for groups 1, 2, 3 was 0.65, 0.48, and 0.33, respectively. CONCLUSION: The overall diagnostic performance of digital CXR to predict calcification in SPNs was moderately accurate and the diagnostic performance for predicting calcification in SPNs was significantly higher, and interobserver reproducibility was good when SPN < 10 mm compared with ≥ 10 mm in diameter. KEY POINTS: • The misdiagnosis of a non-calcified nodule as a calcified one by CXR could lead to poor management choices for the SPN. • The diagnostic performance of CXR in predicting calcification was best for nodules < 10 mm in diameter. SPNs with calcification of approximately 50% of their volume tend to be considered calcified. • The diagnostic performance of CXR in identifying calcification was low for nodules ≥ 10 mm in diameter; therefore, we should carefully evaluate calcification carefully for nodules ≥ 10 mm.


Asunto(s)
Calcinosis/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico , Radiografía Torácica/métodos , Nódulo Pulmonar Solitario/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos
12.
Korean J Gastroenterol ; 71(6): 324-331, 2018 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-29943559

RESUMEN

BACKGROUND/AIMS: The aim of this study was to assess whether increased intestinal gas or fat content in the abdominal cavity is related to abdominal bloating, using three-dimensional abdominal computed tomography scan. METHODS: Twenty-nine healthy individuals without abdominal bloating and organic disease (15 women; mean age, 49 years; range of age, 23-73 years) and 30 patients with chronic recurrent abdominal bloating-diagnosed with functional bloating (10 women; mean age, 53 years; range of age, 35-75 years) - participated in this study. The mean values of measured parameters were compared using independent sample t-test. RESULTS: The mean volume of total colon gas in bloated patients was similar to that in control subjects. The distribution of intra-abdominal gas was also similar between the two groups. However, the amount of gas in the transverse colon tended to be significantly higher in patients with bloating than in controls (p=0.06). Body mass index was similar between the two groups (23.4±3.2 kg/m2 and 22.3±3.1 kg/m2, respectively). Moreover, no significant differences with respect to circumferential area, subcutaneous fat, visceral fat area, and total fat area were found between the two groups. CONCLUSIONS: Bloating might not just be the result of gastrointestinal gas or intra-abdominal fat. Other contributing factors, such as localized abnormality in gas distribution and visceral hypersensitivity, may be involved.


Asunto(s)
Grasa Abdominal/fisiología , Complicaciones Posoperatorias/diagnóstico , Tomografía Computarizada por Rayos X , Grasa Abdominal/diagnóstico por imagen , Adulto , Anciano , Índice de Masa Corporal , Estudios de Casos y Controles , Femenino , Gases/análisis , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Recurrencia , Adulto Joven
13.
Medicine (Baltimore) ; 96(2): e5888, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28079832

RESUMEN

We aimed to compare the diagnostic performance and inter-observer consistency between low dose chest CT (LDCT) and standard dose chest CT (SDCT) in the patients with blunt chest trauma.A total of 69 patients who met criteria indicative of blunt chest trauma (77% of male; age range, 16-85) were enrolled. All patients underwent LDCT without intravenous (IV) contrast and SDCT with IV contrast using parameters as following: LDCT, 40 mAs with automatic tube current modulation (ATCM) and 100 kVp (BMI <25, n = 51) or 120 kVp (BMI>25, n = 18); SDCT, 180 mAs with ATCM and 120 kVp. Transverse, coronal, sagittal images were reconstructed with 3-mm slice thickness without gap and provided for evaluation of 3 observers. Reference standard images (transverse, coronal, sagittal) were reconstructed using SDCT data with 1-mm slice thickness without gap. Reference standard was established by 2 experienced thoracic radiologists by consensus. Three observers independently evaluated each data set of LDCT and SDCT.Multiple-reader receiver operating characteristic analysis for comparing areas under the ROC curves demonstrated that there was no significant difference of diagnostic performance between LDCT and SDCT for the diagnosis of pulmonary injury, skeletal trauma, mediastinal injury, and chest wall injury (P > 0.05). The intraclass correlation coefficient was measured for inter-observer consistency and revealed that there was good inter-observer consistency in each examination of LDCT and SDCT for evaluation of blunt chest injury (0.8601-1.000). Aortic and upper abdominal injury could not be appropriately compared as LDCT was performed without using contrast materials and this was limitation of this study.The effective radiation dose of LDCT (average DLP = 1.52 mSv⋅mGy cm) was significantly lower than those of SDCT (7.21 mSv mGy cm).There is a great potential benefit to use of LDCT for initial evaluation of blunt chest trauma because LDCT could maintain diagnostic image quality as SDCT and provide significant radiation dose reduction. A further study of LDCT with IV contrast for evaluation of aortic and upper abdominal injury is needed.


Asunto(s)
Tomografía Computarizada Multidetector/métodos , Tomografía Computarizada por Rayos X/métodos , Heridas no Penetrantes/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Dosis de Radiación , Adulto Joven
14.
Emerg Radiol ; 24(3): 319-324, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28004325

RESUMEN

Shock thyroid is a part of the hypovolemic shock complex, which is a constellation of secondary computed tomographic (CT) findings that are observed in patients with hypovolemic shock. However, to the best of our knowledge, there has only been a single report on this condition, which described three cases associated with significant thoracoabdominal trauma. Here, we report four patients with profound hypotension who exhibited similar CT findings as those described in the initial report on shock thyroid, but with a more diverse clinical spectrum.


Asunto(s)
Choque/diagnóstico por imagen , Glándula Tiroides/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Masculino
15.
Medicine (Baltimore) ; 95(27): e4164, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27399137

RESUMEN

We explored whether baseline indexed epicardial fat volume (EFVi) and serial changes in EFVi were associated with increase in coronary plaque volume as assessed by multidetector computed tomography.We retrospectively reviewed 87 patients with coronary artery plaque, identified during either baseline or follow-up cardiac computed tomography (CT) examinations. Each plaque volume was measured in volumetric units using a semiautomatic software tool. EFVi was quantified by calculating the total volume of epicardial tissue of CT density -190 to -30 HU, indexed to the body surface area. Clinical cardiovascular risk factors were extracted by medical record review at the time of the cardiac CT examinations. The relationship between EFVi and coronary plaque volume was explored by regression analysis.Although the EFVi did not change significantly from baseline to the time of the follow-up CT (65.7 ±â€Š21.8 vs 66.0 ±â€Š21.8 cm/m, P = 0.620), the plaque volumes were increased significantly on the follow-up CT scans. The annual change in EFVi was not accompanied by a parallel change in coronary plaque volume (P = 0.096-0.500). On univariate analysis, smoking, hypercholesterolemia, 10-year coronary heart disease risk, obesity, and baseline EFVi predicted rapid increases in lipid-rich and fibrous plaque volumes. On multivariate analysis, baseline EFVi (odds ratio = 1.029, P = 0.016) was an independent predictor of a rapid increase in lipid-rich plaque volume.EFVi was shown to be an independent predictor of a rapid increase in lipid-rich plaque volume. However, changes in EFVi were not associated with parallel changes in coronary plaque volume.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/patología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Tomografía Computarizada Multidetector , Pericardio/diagnóstico por imagen , Pericardio/patología , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
16.
AJR Am J Roentgenol ; 205(5): 985-90, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26496545

RESUMEN

OBJECTIVE: The purpose of this article was to evaluate the usefulness of ultralow-dose chest CT as an initial imaging study for evaluation of sharp fish bone esophageal foreign body (FB). MATERIALS AND METHODS: A total of 57 subjects who underwent ultralow-dose chest CT were included in this retrospective study. All subjects had a history of ingestion and symptoms of esophageal FB. All ultralow-dose chest CT data were reconstructed twice, once with filtered back projection (FBP) and once with iterative reconstruction, and three observers reviewed the images independently. ROC analysis was used to evaluate diagnostic performance of ultralow-dose chest CT. Intraclass correlation coefficient (ICC) was calculated for analysis of interobserver agreement. RESULTS: Among 57 patients, 42 were confirmed as having esophageal FB. Significant objective noise reduction of mediastinum was achieved using an iterative reconstruction technique. Subjective image noise of iterative reconstruction was significantly better than that of FBP. Overall diagnostic performance of ultralow-dose chest CT for esophageal FB of iterative reconstruction (AUC = 0.999) was significantly better than that of FBP (AUC = 0.95) (p = 0.02). Interobserver agreement was greater for iterative reconstruction (ICC = 0.944) than for FBP (ICC = 0.778). CONCLUSION: Ultralow-dose chest CT using iterative reconstruction provided satisfactory diagnostic image quality for identifying fish bone esophageal FB with reduced radiation dose and high observer accuracy. Therefore, ultralow-dose chest CT would be adequate as a first-line imaging modality for fish bone esophageal FB.


Asunto(s)
Huesos/diagnóstico por imagen , Esófago/diagnóstico por imagen , Cuerpos Extraños/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Animales , Servicio de Urgencia en Hospital , Femenino , Peces , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Radiografía Torácica , Estudios Retrospectivos
17.
Int J Cardiovasc Imaging ; 31 Suppl 2: 187-96, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26428676

RESUMEN

We evaluated the relationship between coronary artery disease (CAD) and left ventricular mass (LVM) as measured by cardiac computed tomography (CT) in young adults ≤40 years of age. We retrospectively enrolled 490 consecutive individuals (383 males; mean age, 35.2 ± 4.4 years) who underwent cardiac CT. CAD was defined by the presence of any plaque detected by coronary CT angiography. Left ventricular (LV) function, including LVM, was automatically measured by a dedicated workstation. LVM and LVM index (LVMi) in patients with CT-detected CAD were compared to those of patients without CT-detected CAD. Logistic regression analysis was used to evaluate the relationship between cardiovascular risk factors and CAD. Fifty-five individuals had CT-detected CAD (11.2 %, 53 males). LVM measured by cardiac CT was 126.9 ± 30.0 g for males and 93.6 ± 20.9 g for females. LVM was higher (117.8 ± 30.8 vs. 133.6 ± 33.1 g, P < 0.001) in patients with CT-detected CAD compared with patients without CT-detected CAD. Obesity, hypertension, smoking, hypercholesterolemia, LVM and LVMi were predictors of CT-detected CAD. Body mass index (r = 0.237, P < 0.001) and systolic blood pressure (r = 0.281, P < 0.001) were positively correlated with LVM. In the multivariate analysis, LVM [odds ratio (OR) = 1.016] and LVMi (OR = 1.026) remained independent predictors of CAD. LVM and LVMi in patients with CT-detected CAD were higher than that of patients without CT-detected CAD. LVM and LVMi measured by cardiac CT were independent predictors of CAD.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Tomografía Computarizada Multidetector , Adulto , Distribución de Chi-Cuadrado , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Hipertrofia Ventricular Izquierda/fisiopatología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Placa Aterosclerótica , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Ultrasonografía , Función Ventricular Izquierda , Remodelación Ventricular
18.
Eur J Radiol ; 83(10): 1977-82, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25082475

RESUMEN

OBJECTIVES: To investigate the prevalence of simple pulmonary eosinophilia (SPE) and validate CT findings of SPE found on follow-up CT of oncologic patients. METHODS: We retrospectively reviewed 6977 cases of oncologic patients who underwent chest CT. A total of 66 individuals who met criteria for having SPE were identified. CT scans were fully re-assessed by consensus of 2 radiologists in terms of characteristics of pulmonary lesions. RESULTS: The prevalence of SPE was 0.95%. A total of 193 lesions were identified and most of the lesions showed part-solid pattern (69.9%), round to ovoid contour (46.1%), ill-defined margin (90.2%), or partial halo appearance (74.8%). In addition, almost half of the lesions showed the vascular contact (49%). SPE appeared as either solitary (42.4%) or multiple lesions (57.6%). The majority of lesions were located in the periphery (76.2%), and lower lung zonal (67.4%) predominance was found. CONCLUSIONS: The frequency of SPE in oncologic patients with CT findings of GGO, part-solid lesion was high (17.5%). Therefore, when key features of CT findings suggesting SPE (part-solid nodule; ill-defined margin; peripheral distribution; and lower lung zone predominance) are newly discovered on follow-up chest CT in oncologic patients, it would be useful to correlate with blood test and do short-term follow-up in order to avoid unnecessary invasive procedure.


Asunto(s)
Neoplasias/complicaciones , Eosinofilia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Eosinofilia Pulmonar/epidemiología , Radiografía Torácica , Estudios Retrospectivos
19.
AJR Am J Roentgenol ; 201(5): W707-11, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24147500

RESUMEN

OBJECTIVE: The purpose of this study was to validate the usefulness of MDCT for diagnosis of a sharp or pointed esophageal foreign body according to esophageal level. MATERIALS AND METHODS: Forty-two patients with a history of sharp or pointed foreign body ingestion were reviewed retrospectively. Two observers interpreted the CT and the conventional radiography datasets separately. If a foreign body was directly identified, it was regarded as a positive finding. Even if no high-density foreign body was found, detection of a secondary finding was considered to be a positive finding. Diagnostic performance of MDCT and conventional radiography were compared according to esophageal level. Final diagnosis was made by esophagoscopy or surgery in addition to the clinicoradiologic result. RESULTS: MDCT was statistically superior to conventional radiography for diagnosis of a thoracic esophageal foreign body for both observers (p < 0.001 for each). No significant difference in sensitivity between CT and conventional radiography for diagnosis of cervical esophageal foreign body was noted regardless of observer. Both observers could identify all complicated conditions with MDCT regardless of esophageal level. However, in two of three cases of complicated thoracic esophageal foreign bodies, neither observer could detect foreign bodies on conventional radiography; furthermore, the observers could not identify pneumomediastinum. CONCLUSION: In cases of sharp or pointed foreign body ingestion, if the result of an initial inspection of oro- and hypopharynx reveals negative findings, the first imaging modality should be MDCT for better diagnosis and management.


Asunto(s)
Esófago/diagnóstico por imagen , Cuerpos Extraños/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Medios de Contraste , Femenino , Cuerpos Extraños/terapia , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
20.
J Comput Assist Tomogr ; 37(3): 387-94, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23674010

RESUMEN

PURPOSE: We assessed the accuracy of coronary computed tomography angiography (CTA) in patients with an Agatston calcium score (ACS) of greater than 400 by comparing it with invasive coronary angiography (ICA), and we evaluated the predictive value of CTA for obstructive coronary heart disease (CHD) compared with traditional clinical risk assessment. METHODS: A total of 253 patients who had an ACS of greater than 400 were enrolled in this study. The degree of coronary stenosis was visually and quantitatively estimated by postprocessing imaging using 15-segment coronary models. All patients underwent ICA after a mean (SD) of 34 (24) days, and the degree of coronary stenosis was compared with the results of CTA. RESULTS: Computed tomography angiography accurately diagnosed significant stenosis in 204 (99.0%) of 206 patients and in 649 (83.5%) of 777 segments. When the patients were considered based on their ACS (group A, 400 < ACS ≤ 1000, vs group B, ACS > 1000), group B showed lower specificity (9.1% vs 41.7%) and poorer agreement (k = 0.149 vs 0.495) than for ICA. By segment-based analysis, the agreement between CTA and ICA was good (k = 0.729), and there was no significant difference between groups A (k = 0.728) and B (k = 0.727). Computed tomography angiography was the most powerful predictor (odds ratio = 52.645, P < 0.001), whereas the 10-year CHD risk and pretest probability were not significantly correlated with obstructive CHD. CONCLUSIONS: Despite good overall diagnostic accuracy, coronary CTA in this group of patients was limited by low specificity. However, CTA was a better predictor of obstructive CHD compared with clinical predictors, and it avoided unnecessary ICA, even in patients with extensive coronary artery calcification.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Calcinosis/diagnóstico por imagen , Distribución de Chi-Cuadrado , Medios de Contraste , Femenino , Humanos , Yopamidol/análogos & derivados , Modelos Lineales , Masculino , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA