Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
Animal ; 18(11): 101331, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39405960

RESUMEN

Semen traits play a crucial role in pig reproduction and fertility. However, limited data availability hinder a comprehensive understanding of the genetic mechanisms underlying these traits. In this study, we integrated 597 299 ejaculates and 3 596 sequence data to identify genetic variants and candidate genes related to four semen traits, including sperm progressive motility (MOT), semen volume, sperm concentration (CON), and effective sperm count (SUM). A cross-ancestry meta-genome-wide association study was conducted to detect 163 lead single nucleotide polymorphisms (SNPs) associated with MOT, CON, and SUM. Subsequently, transcriptome-wide association studies and colocalisation analyses were integrated to identify 176 candidate genes, many of which have documented roles in spermatogenesis or male mammal semen traits. Our analysis highlighted the potential involvement of CSM5, PDZD9, and LDAF1 in regulating semen traits through multiple methods. Finally, to validate the function of significant SNPs, we performed genomic feature best linear unbiased prediction in 348 independent pigs using identified trait-related SNP subsets as genomic features. We found that integrating the top 0.1, 1, and 5% significant SNPs as genomic features could enhance genomic prediction accuracy for CON and MOT compared to traditional genomic best linear unbiased prediction. This study contributes to a comprehensive understanding of the genetic mechanisms of boar semen traits and provides insight for developing genomic selection models.

2.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(10): 1044-1048, 2024 Oct 09.
Artículo en Chino | MEDLINE | ID: mdl-39344457

RESUMEN

In fixed prosthodontics, clear exposure of the preparation margin is the prerequisite for obtaining accurate digital impressions and improving the marginal fit of restorations. To resolve the issues associated with the cord retraction technique, such as pain, acute injury, and prolonged procedural time, this study proposes a new technology for intraoral digital impression taking with pneumatic gingival retraction. The new scanning head blows a high-speed airflow that instantaneously separates the free gingiva, locally exposing the subgingival preparation margin. Combined with the farthest point preservation stitching algorithm based on the distance from the normal vector and high-speed laser scanning photography, it achieves global preparation edge data and gingival reconstruction, realizing painless, non-invasive, and efficient precise acquisition of the preparation margin. Using this new technique, a patient with a full porcelain crown restoration on a posterior tooth was treated. The digital impression revealed a clear margin of the preparation, and the crown made from this data has a good marginal fit.


Asunto(s)
Coronas , Técnica de Impresión Dental , Humanos , Encía , Técnicas de Retracción Gingival , Porcelana Dental , Restauración Dental Permanente/métodos , Diseño Asistido por Computadora
3.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(10): 1070-1074, 2024 Oct 09.
Artículo en Chino | MEDLINE | ID: mdl-39344462

RESUMEN

During the complete denture restoration process, accurate impression making is a crucial step for achieving good denture retention. With the increasing popularity of intraoral scanning technology in fixed restoration, the use of intraoral scanning technology in complete denture restoration for edentulous jaw has also been developed. This article systematically reviews the research progress and application of intraoral scanning of edentulous soft tissue, focusing on difficulties in intraoral scanning of edentulous jaws, scanning accuracy, clinical application effects, as well as precautions involved. The aim is to provide references for clinical application.


Asunto(s)
Técnica de Impresión Dental , Arcada Edéntula , Humanos , Arcada Edéntula/diagnóstico por imagen , Dentadura Completa , Diseño Asistido por Computadora , Diseño de Dentadura/métodos
4.
Zhonghua Jie He He Hu Xi Za Zhi ; 47(3): 240-244, 2024 Mar 12.
Artículo en Chino | MEDLINE | ID: mdl-38448175

RESUMEN

We reported a case of 73-year-old male with multiple pulmonary nodules and cavities. The patient was admitted with a chief complaint of "dry cough with shortness of breath for 3 months". Chest CT showed multiple irregular masses, nodules, and patchy lesions in both lungs, accompanied by the formation of cavities. He also had anemia and renal dysfunction. Despite given empirical anti-infective and anti-tuberculosis treatments, the pulmonary nodules progressed, and the cavities enlarged. Anti-neutrophil cytoplasmic antibodies (ANCA) were negative twice. Bronchoscopic biopsy was performed. The mucosal pathology of the right middle lobe lesion showed little necrosis, focal granulomatous structure formation, and relevant vasculitis and remaining vessel wall structure in the necrosis lesions by elastic fiber staining. A clinical diagnosis of ANCA-negative necrotizing granulomatous polyangiitis was made and the patient was treated with glucocorticoids and cyclophosphamide. The nodules and cavities shrank, and some lesions were absorbed.


Asunto(s)
Anticuerpos Anticitoplasma de Neutrófilos , Granulomatosis con Poliangitis , Masculino , Humanos , Anciano , Granulomatosis con Poliangitis/diagnóstico , Biopsia , Tos , Necrosis
5.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(1): 94-100, 2023 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-36718695

RESUMEN

OBJECTIVE: To study microstructure, friction and wear behaviors of silicon-lithium spray coating on the surface of zirconia ceramics and to preliminarily evaluate its esthetic so as to provide support and guidance for the clinical application. METHODS: Zirconia ceramic specimens were randomly divided into three groups: coating group (two subgroups), polishing group (two subgroups), and glazing group (four subgroups), with 10 samples in each subgroup. The two subgroups of coating group were the zirconia ceramics with the untreated and preliminary polishing surfaces sprayed with silicon-lithium coating, respectively. The two subgroups of polishing group were preliminary polishing and fine polishing of zirconia ceramics, respectively. The four subgroups of glazing group were preliminarily polished zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively; and untreated zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively. The above 8 subgroups of zirconia ceramic specimens were used as friction pairs with 80 steatite ceramics for 50 000 chewing cycles under 50 N vertical load and artificial saliva lubrication using chewing simulation. Scanning electron microscope was used to observe the microstructure of the surface and section of the coating group, and the thickness of the coating and glazing were measured. The linear roughness of the coating and polishing groups was mea-sured using a laser confocal scanning microscope. Vickers hardness was measured using a microhardness tester and the esthetic of zirconia ceramic full crown sprayed with silicon-lithium coating was preliminarily evaluated. White light interferometer was used to measure the width, the maximum depth and the volume of the wear scars of each group, and the wear depth of steatite ceramics and wear rate of zirconia ceramic specimens were calculated. Kruskal-Wallis nonparametric test and Dunn's multiple comparisons test were used to analyze the wear depth of each group (α=0.05). RESULTS: The microstructures of the silica-lithium spray coatings on the untreated and preliminarily polished zirconia ceramic surfaces showed the protruding defects, and the line roughness of coating group was larger than that of the polishing group. The median thickness of the silica-lithium spray coating on the preliminarily polished zirconia ceramic was 13.0 µm (interquartile range, IQR: 11.6, 17.9), while that of the silica-lithium spray coating on the untreated zirconia ceramic was 4.4 µm (IQR: 4.1, 4.7). The Vickers hardness and wear rate of the coating group were between the polishing group and the glazing group. The wear depths of the wear scars of steatite ceramics were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference between glazing and polishing groups (P < 0.05). With the increase of polishing procedure, the wear depth of steatite ceramics decreased in each subgroups. The orders of maximum depth and volume of wear scars of zirconia ceramic were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference in the maximum depth of wear scars between glazing and polishing groups (P < 0.05). CONCLUSION: The silica-lithium spray coating on the zirconia ceramic, can be used as a new method for zirconia ceramic surface treatment, because it can increase the esthetic of zirconia ceramics compared with polishing and reduce the wear of steatite ceramics compared with glazing.


Asunto(s)
Litio , Silicio , Humanos , Ensayo de Materiales , Fricción , Cicatriz , Propiedades de Superficie , Dióxido de Silicio , Circonio/química , Cerámica , Porcelana Dental
6.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(6): 1219-1223, 2022 Dec 18.
Artículo en Chino | MEDLINE | ID: mdl-36533359

RESUMEN

Hemophagocytic lymphohistiocytosis (HLH) was a life-threatening syndrome due to the uncontrolled immune activation of cytotoxic T lymphocytes, natural killer (NK) cells, and macrophages. HLH is characterized by primary and secondary causes, the early diagnosis and treatment of patients are closely related to the prognosis and clinical outcome of patients. The clinical presentation is variable but mostly includes prolonged fever, splenomegaly, coagulopathy, hypertriglyceridemia, and hemophagocytosis, none of them is specific and particular for HLH. Tuberculosis (TB) infection is one of the causes of HLH. HLH caused by TB is very rare clinically, but it has a high mortality. For patients with fever of unknown origin, HLH-related clinical manifestations sometimes present before the final diagnosis of TB, and HLH is associated with the most significant mortality rate. This article is mainly about a 28-year-old patient with HLH who suffered from severe TB infection. The patient attended a hospital with a history of 2 months of prolonged fever, 10 days booger and subcutaneous hemorrhage in lower limbs. Before this, he was in good health and denied any history of tuberculosis exposure. Combined with relevant laboratory test results (such as splenomegaly, hemoglobin, platelet count, and hypertriglyceridemia) and clinical manifestations (e.g. fever), the patient was diagnosed with hemophagocytic lymphohistiocytosis, but the etiology of HLH remained to be determined. To confirm the etiology, the patient was asked about the relevant medical history (intermittent low back pain) and was performed chest CT scan, bone marrow biopsy, and fundus photography. Finally, he was diagnosed with hemophagocytic lymphohistiocytosis caused by hematogenous disseminated pulmonary tuberculosis. In response to this, intravenous methylprednisolone and anti-tuberculosis treatment (isoniazid, pyrazinamide, moxifloxacin, and amikacin) were administered to the patient. After more than a month of treatment, the patient recovered from HLH caused by severe TB infection. Therefore, this case suggests that we should be vigilant to the patient who admitted to the hospital with fever for unknown reasons, to diagnose HLH as early as possible and clarify its cause, then perform interventions and treatment, especially HLH secondary to tuberculosis. Also, cases of atypical TB and severe TB should be carefully monitored to achieve early diagnosis and early intervention.


Asunto(s)
Hipertrigliceridemia , Linfohistiocitosis Hemofagocítica , Tuberculosis Pulmonar , Masculino , Humanos , Adulto , Linfohistiocitosis Hemofagocítica/complicaciones , Linfohistiocitosis Hemofagocítica/diagnóstico , Esplenomegalia , Tuberculosis Pulmonar/complicaciones , Tuberculosis Pulmonar/diagnóstico , Médula Ósea/patología , Fiebre/etiología , Hipertrigliceridemia/complicaciones
7.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(10): 1015-1021, 2022 Oct 09.
Artículo en Chino | MEDLINE | ID: mdl-36266074

RESUMEN

Objective: To measure and analyze parameters of the three-dimensional (3D) model of the condylar movement envelope surface (ES) and provide a reference for the design of the temporomandibular prosthesis. Methods: Thirty-four healthy adults aged (25.4±2.8) years were recruited from the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology as subjects. There were 9 males and 25 females, most of them were university students and others outside the university have received undergraduate education or above. Condylar movement ES were obtained using the previous method on the 3D trajectory of condyle. The simulations of condylar movement were projected according to opening movements, protrusion movements, and lateral movements respectively. The total area of the ES and the area proportions of models formed by above different mandibular movements were measured and calculated. The adults' head and maxillofacial 3D models reconstructed by cone beam CT were registered with ES in Geomagic Studio. The inner and outer poles of the condyle, the corrective sagittal axis of the ES, and the median sagittal plane (MSP) were calibrated in registration models using Geomagic Studio, and the parameters were measured as follows: the anteroposterior and medialateral diameters of the condyle, the anteroposterior diameters and the transverse diameters (anterior, middle and posterior parts) of the ES, the angles between the corrective sagittal axis of the ES and MSP (ES-MSP). Pearson correlation analysis was performed by SPSS 24.0. Results: The total area of the ES was (760±133) mm2, the opening movement part accounted for (63.3±15.2)%, the protrusion movement part accounted for (14.9±9.6)%, the lateral movement part accounted for (21.8±13.3)%. Parameter measurements were as follows: mediolateral diameters of condyle was (19.8±2.3) mm; anteroposterior diameter of the ES was (21.2±3.1) mm, the transverse diameters (anterior, middle and posterior parts) of the ES were (20.6±2.4), (20.4±2.4), (22.0±2.6) mm, respectively; the transverse diameters of the ES were about 2 mm larger than that of the condyle. The angle between the corrective sagittal axis of ES and the MSP was 6.8°±6.2°. The coefficient of variation (CV) in these parameters showed: CV of the transverse diameters (anterior, middle and posterior parts) of the ES and mediolateral diameter of the condyle were 0.98, 0.99, 0.93, respectively (P<0.001). CV of aera of ES and mediolateral diameter of the condyle was 0.64 (P=0.002). CV of aera of ES and anteroposterior diameter of ES was 0.62 (P=0.004). Conclusions: The 3D envelope surface model formed by mandibular opening movements accounted for the largest proportion of the ES. The corrective sagittal axis of the ES was at an angle to the MSP, the transverse diameters (anterior, middle and posterior parts) of the ES were approximately 2 mm larger than the mediolateral diameter of the condyle, the transverse diameters (anterior, middle and posterior parts) of the ES were highly positively correlated with the mediolateral diameter of the condyle.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Cóndilo Mandibular , Humanos , Adulto , Masculino , Femenino , Mandíbula , Movimiento , Articulación Temporomandibular
8.
Zhonghua Jie He He Hu Xi Za Zhi ; 45(9): 920-925, 2022 Sep 12.
Artículo en Chino | MEDLINE | ID: mdl-36097929

RESUMEN

Acute exacerbation of chronic obstructive pulmonary disease (COPD) is an important part of the course of COPD. Patients with life-threatening acute exacerbation need to be admitted to the respiratory intensive care unit (RICU) for treatment in time. Malnutrition is common in COPD patients, and nutritional risk also has a high prevalence in patients with COPD exacerbation, which is closely associated with the clinical outcome and mortality of these patients. Identifying patients with high nutritional risk and providing appropriate nutritional treatment will help to improve survival rate, shorten length of hospital stay and reduce complications. This review describes the potential mechanisms of malnutrition in patients with COPD, the nutritional risk assessment of patients with COPD exacerbation hospitalized in RICU, the selection of nutritional treatment methods and formulas, and the relevant problems of nutritional management of patients required noninvasive ventilation, hoping to provide information for the optimization of nutritional treatment strategy for acute exacerbation of COPD and the exploration of clinical research in the future.


Asunto(s)
Desnutrición , Enfermedad Pulmonar Obstructiva Crónica , Hospitalización , Humanos , Unidades de Cuidados Intensivos , Tiempo de Internación , Desnutrición/complicaciones , Desnutrición/terapia , Enfermedad Pulmonar Obstructiva Crónica/complicaciones
9.
Zhonghua Yi Xue Za Zhi ; 102(28): 2214-2216, 2022 Jul 26.
Artículo en Chino | MEDLINE | ID: mdl-35872587

RESUMEN

The data of 18 patients with allergic bronchopulmonary aspergillosis (ABPA) who received aspergillus fumigatus-specific IgG detection from 2015 to 2021 in Peking University Third Hospital were retrospectively analyzed. Among them, 11 were male and 7 were female, aged 18-79 years. All patients had a history of asthma or symptoms of cough and asthma, and aspergillus fumigatus-specific IgE was positive; 16 patients had total serum IgE>500 U/ml, of which 13 patients had total serum IgE>1 000 U/ml. Among other diagnostic indicators, peripheral blood eosinophils were >0.5×109/L in 16 cases; lung CT showed bronchiectasis in 15 cases; serum aspergillus fumigatus-specific IgG was positive (>120 AU/ml) in 10 cases. There was no significant difference in serum total IgE level, peripheral blood eosinophil count, and bronchiectasis ratio between positive and negative cases of aspergillus fumigatus-specific IgG (all P>0.05). In this study, the positive rate of aspergillus fumigatus-specific IgG in patients with ABPA was more than 50%, which has auxiliary value in the diagnosis of ABPA.


Asunto(s)
Aspergilosis Broncopulmonar Alérgica , Asma , Bronquiectasia , Aspergilosis Broncopulmonar Alérgica/diagnóstico , Aspergillus fumigatus , Femenino , Humanos , Inmunoglobulina E , Inmunoglobulina G , Masculino , Estudios Retrospectivos
10.
Zhonghua Jie He He Hu Xi Za Zhi ; 45(4): 333-334, 2022 Apr 12.
Artículo en Chino | MEDLINE | ID: mdl-35381628

RESUMEN

Influenza vaccination has been shown to reduce lower airway infections requiring hospitalization, and reduce mortality and exacerbation frequency in patients with chronic obstructive pulmonary disease(COPD), and therefore is recommended for all COPD patients by guidelines. However, the coverage of influenza vaccination in Chinese COPD patients is far from satisfactory. The large-scale COVID-19 vaccination may have a positive impact on the attitude towards influenza vaccines, and healthcare professionals should take active measures to improve the rate of influenza vaccination in patients with COPD.


Asunto(s)
COVID-19 , Gripe Humana , Enfermedad Pulmonar Obstructiva Crónica , Vacunas contra la COVID-19 , Humanos , Gripe Humana/prevención & control , Vacunación
11.
Zhonghua Jie He He Hu Xi Za Zhi ; 45(4): 362-367, 2022 Apr 12.
Artículo en Chino | MEDLINE | ID: mdl-35381633

RESUMEN

Objective: To investigate the current status of the application of diagnostic and assessment tools for chronic obstructive pulmonary disease(COPD) by respiratory physicians in China. Method: An on-line questionnaire was designed to address the common questions in COPD diagnosis and evaluation, and this survey was conducted through Wechat. Result: A total of 3 204 valid questionnaires were collected. 71.7% of the physicians were from tertiary hospitals. 75.4% of the physicians diagnosed COPD strictly on the basis of lung function results after inhaled bronchodilators, and this percentage was higher in tertiary hospitals than in secondary hospitals(78.71% vs. 66.92%, P<0.01). 99.3% of the physicians evaluated symptoms of dyspnea, but 26.8% of physicians did not use a scoring system(CAT or mMRC) for quantitative assessment. Although 83.8% of physicians would use the guideline-recommended comprehensive assessment(ABCD classification), only 45.1% of them chose initial therapy exactly according to the classification. In addition, 28.3% of physicians did not routinely order blood eosinophil counts and 20.1% did not inquire the history of tuberculosis. Conclusions: Although most respiratory physicians followed the guidelines in the diagnosis and evaluation of COPD, the use of assessment tools was inadequate, which should be addressed in educational programs for COPD management.


Asunto(s)
Médicos , Enfermedad Pulmonar Obstructiva Crónica , Broncodilatadores , Disnea , Humanos , Enfermedad Pulmonar Obstructiva Crónica/terapia , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios
12.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(5): 540-546, 2022 May 09.
Artículo en Chino | MEDLINE | ID: mdl-35484679

RESUMEN

With the advent of the era of big data, artificial intelligence based on machine learning, especially artificial neural network has rapidly developed and applicated in the field of stomatology, owning huge potential in segmentation and labelling of three-dimensional intraoral anatomical features. Automatic segmentation, labelling and diagnosis can assist dentists and technicians to complete heavy and repeat work, change stomatology from subjective perception to objective science, and help to make diagnosis and treatment plan efficiently and accurately. This review briefly summarized related knowledge and development of machine learning and artificial neural network, its application status and existing problems in the field of segmentation and labelling of three-dimensional intraoral anatomical features, and provided an outlook of its future development.


Asunto(s)
Inteligencia Artificial , Redes Neurales de la Computación , Aprendizaje Automático
13.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 7-12, 2022 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-35165461

RESUMEN

According to the fourth national oral health epidemiological survey report (2018), billions of teeth are lost or missing in China, inducing chewing dysfunction, which is necessary to build physiological function using restorations. Digital technology improves the efficiency and accuracy of oral restoration, with the application of three-dimensional scans, computer-aided design (CAD), computer-aided manufacturing (CAM), bionic material design and so on. However, the basic research and product development of digital technology in China lack international competitiveness, with related products basically relying on imports, including denture 3D design software, 3D oral printers, and digitally processed materials. To overcome these difficulties, from 2001, Yuchun Sun's team, from Peking University School and Hospital of Stomatology, developed a series of studies in artificial intelligence design and precision bionics manufacturing of complex oral prostheses. The research included artificial intelligence design technology for complex oral prostheses, 3D printing systems for oral medicine, biomimetic laminated zirconia materials and innovative application of digital prosthetics in clinical practice. The research from 2001 to 2007 was completed under the guidance of Prof. Peijun Lv and Prof. Yong Wang. Under the support of the National Natural Science Foundation of China, the National Science and Technology Support Program, National High-Tech R & D Program (863 Program) and Beijing Training Project for the Leading Talents in S & T, Yuchun Sun's team published over 200 papers in the relevant field, authorized 49 national invention patents and 1 U.S. invention patent and issued 2 national standards. It also developed 8 kinds of core technology products in digital oral prostheses and 3 kinds of clinical diagnosis and treatment programs, which significantly improved the design efficiency of complex oral prostheses, the fabrication accuracy of metal prostheses and the bionic performance of ceramic materials. Compared with similar international technologies, the program doubled the efficiency of bionic design and manufacturing accuracy and reduced the difficulty of diagnosis and cost of treatment and application by 50%, with the key indicators of those products reaching the international leading level. This program not only helped to realize precision, intelligence and efficiency during prostheses but also provided functional and aesthetic matches for patients after prostheses. The program was rewarded with the First Technical Innovation Prize of the Beijing Science and Technology Awards (2020), Gold Medal of Medical Research Group in the First Medical Science and Technology Innovation Competition of National Health Commission of the People's Republic of China (2020) and Best Creative Award in the First Translational Medical Innovation Competition of Capital (2017). This paper is a review of the current situation of artificial intelligence design and precision bionics manufacturing of complex oral prosthesis.


Asunto(s)
Inteligencia Artificial , Biónica , Diseño Asistido por Computadora , Diseño de Prótesis Dental , Humanos , Impresión Tridimensional , Prótesis e Implantes
14.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 31-39, 2022 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-35165465

RESUMEN

OBJECTIVE: To investigate the effect of porous surface morphology of zirconia on the proliferation and differentiation of osteoblasts. METHODS: According to different manufacturing and pore-forming methods, the zirconia specimens were divided into 4 groups, including milled sintering group (M-Ctrl), milled porous group (M-Porous), 3D printed sintering group (3D-Ctrl) and 3D printed porous group (3D-Porous). The surface micromorphology, surface roughness, contact angle and surface elements of specimens in each group were detected by scanning electron microscope (SEM), 3D laser microscope, contact angle measuring device and energy-dispersion X-ray analysis, respectively. MC3T3-E1 cells were cultured on 4 groups of zirconia discs. The cell morphology of MC3T3-E1 cells on zirconia discs was eva-luated on 1 and 7 days by SEM. The cell proliferation was detected on 1, 3 and 5 days by cell counting kit-8 (CCK-8). After osteogenic induction for 14 days, the relative mRNA expression of alkaline phosphatase (ALP), type Ⅰ collagen (Colla1), Runt-related transcription factor-2 (Runx2) and osteocalcin (OCN) in MC3T3-E1 cells were detected by real-time quantitative polymerase chain reaction. RESULTS: The pore size [(419.72±6.99) µm] and pore depth [(560.38±8.55) µm] of 3D-Porous group were significantly larger than the pore size [(300.55±155.65) µm] and pore depth [(69.97±31.38) µm] of M-Porous group (P < 0.05). The surface of 3D-Porous group appeared with more regular round pores than that of M-Porous group. The contact angles of all the groups were less than 90°. The contact angles of 3D-Ctrl (73.83°±5.34°) and M-Porous group (72.7°±2.72°) were the largest, with no significant difference between them (P>0.05). Cells adhered inside the pores in M-Porous and 3D-Porous groups, and the proliferation activities of them were significantly higher than those of M-Ctrl and 3D-Ctrl groups after 3 and 5 days' culture (P < 0.05). After 14 days' incubation, ALP, Colla1, Runx2 and OCN mRNA expression in 3D-Porous groups were significantly lower than those of M-Ctrl and 3D-Ctrl groups (P < 0.05). Colla1, Runx2 and OCN mRNA expressions in M-Porous group were higher than those of 3D-Porous group (P < 0.05). CONCLUSION: The porous surface morphology of zirconia can promote the proliferation and adhesion but inhibit the differentiation of MC3T3-E1 cells.


Asunto(s)
Cerámica , Osteoblastos , Diferenciación Celular , Proliferación Celular , Osteogénesis , Porosidad , Circonio
15.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 105-112, 2022 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-35165476

RESUMEN

OBJECTIVE: To compare the retentions of different designs of cobalt-chromium (Co-Cr), pure titanium (CP Ti), and titanium alloy (Ti-6Al-4V) removable partial denture (RPD) circumferential clasps manufactured by selective laser melting (SLM) and to analyze the stress distribution of these clasps during the removal from abutment teeth. METHODS: Clasps with clasp arm size A (1.9 mm width/1.1 mm thickness at the body and 0.8-taper) or B (1.2 times A) and 0.25 mm or 0.50 mm undercut engagement were modeled on a prepared first premolar die, named as designs A1, A2, A3, and A4, respectively. The density and elastic modulus of SLM-built Co-Cr, CP Ti, and Ti-6Al-4V were measured and given to different groups of clasps. The density, elastic modulus, and Poisson ' s ratio of enamel were given to the die. The control group was the cast Co-Cr clasp with design A1, to which the density and elastic modulus of cast Co-Cr alloy were given. The Poisson's ratio of all metals was 0.33. The initial 5 N dislodging force was applied, and the maximum displacement of the clasp along the insertion path was computed. The load was reapplied with an increment of 5 N than in the last simulation until the clasp was completely dislodged. The retentive force range of different groups of clasps was obtained. The retentive forces of the SLM-built Co-Cr, CP Ti, and Ti-6Al-4V clasps with equivalent computed retentive force range to the control group were validated through the insertion/removal experiment. The von Mises stress distributions of these three groups of SLM-built clasps under 15 N loads were analyzed. RESULTS: SLM-built Co-Cr, CP Ti, and Ti-6Al-4V clasps with designs B1 or B2, and Co-Cr clasps with design A2 had higher retentive forces than those of the control group. SLM-built CP Ti and Ti-6Al-4V clasps with design A1 had lower retentive forces than those of the control group. SLM-built Co-Cr clasp with design A1 and SLM-built CP Ti and Ti-6Al-4V clasps with design A2 had equivalent retentive forces to those of the control group. The insertion/removal experiment showed that the measured retentive forces of these three groups of SLM-built clasps were (21.57±5.41) N, (19.75±4.47) N, and (19.32±2.04) N, respectively. No statistically significant measured retentive force difference was found among these three groups of SLM-built clasps (P>0.05). The maximum von Mises stress of these three groups of SLM-built clasps exceeded their responding yield strength except for the Ti-6Al-4V one. CONCLUSION: SLM-built Co-Cr circumferential clasps had higher retention than CP Ti and Ti-6Al-4V ones with the same clasp arm size and undercut engagement. The retention of SLM-built circumferential clasps could be adjusted by changing the undercut engagement and clasp arm size. If SLM-built circumferential clasps are used in clinical practice, the Ti-6Al-4V clasp with clasp arm size A and 0.50 mm undercut engagement is recommended considering the long-term use of RPD in the patient's mouth.


Asunto(s)
Dentadura Parcial Removible , Aleaciones de Cromo , Abrazadera Dental , Retención de Dentadura , Análisis de Elementos Finitos , Humanos , Rayos Láser , Titanio
16.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(2): 162-167, 2022 Feb 09.
Artículo en Chino | MEDLINE | ID: mdl-35152652

RESUMEN

Objective: To evaluate the effect of adding a geometric feature on the accuracy of digital impressions obtained by intraoral scanners for implant restoration of edentulous jaw quantitatively. Methods: A dentiform model of the maxilla of completely edentulous arch with 6 implant analogs+scan bodies (No. 1-6) was selected as the reference model. Without geometric feature, the dentiform model was scanned by dental model scanner and repeated for 5 times as true value group. Before and after adding the geometric feature, the same operator used intraoral scanner A (Trios 3) and B (Aoralscan 2) to scan the dentiform model with the same scanning path. Each type of intraoral scanner scanned 10 times and ".stl " datas were obtained. The results were imported into reverse engineering software (Geomagic Studio 2015). The linear distances of center point of upper plane between sacn body 1 to 6 was calculated, denoted as D12, D13, D14, D15 and D16. Trueness was the absolute value subtracted from the measured value of the intraoral scanner groups and true value; precision was the absolute value of pairwise subtraction of the measured values in the intraoral scanner groups.The smaller the value, the better the accuracy or precision.With or without the feature, all scan data were statistically analyzed, and the effect of adding geometric feature on the trueness and precision of the two intraoral scanners were evaluated. Results: As for intraoral scanner A, with the feature in place, significant differences were found in D14, D15, D16 for tureness(t=2.66, 2.75, 2.95, P<0.05); the trueness for D16 decreased from (101.9±47.1) µm to (49.6±30.3) µm. On the other hand, with features on the edentulous area, the precision was significantly increased in D15 and D16 (U=378.00, 672.00, P<0.05); the precision for D15 decreased from 40.8 (45.1) µm to 13.1 (17.0) µm. As for intraoral scanner B, the trueness of D12, D13 and D14 after adding geometric features was significantly better than before (t=3.02, 2.66, U=22.00, P<0.05). With feature on the edentulous area, the trueness for D13 decreased from (116.6±41.2) µm to (70.8±35.5) µm. There was no statistical significance in the trueness of D15 and D16 with or without geometric feature (P>0.05), however, the precision of D15 and D16 after adding geometric feature was significantly better than before (U=702.00, 489.00,P<0.05). The precision of D16 decreased from 112.5 (124.7) µm to 35.9 (85.8) µm. Conclusions: The use of geometric feature in edentulous space improves the trueness and precision of the different principle intraoral scanners tested.


Asunto(s)
Implantes Dentales , Técnica de Impresión Dental , Diseño Asistido por Computadora , Imagenología Tridimensional , Modelos Dentales
17.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(1): 101-106, 2022 Jan 09.
Artículo en Chino | MEDLINE | ID: mdl-35012259

RESUMEN

In dental esthetic rehabilitation, patients pay great attention to the rehabilitative esthetic effect before teeth preparation, and this is also an important content of doctor-patient communication. Along with the development and combined application of intraoral scan, three-dimensional (3D) face scan, digital design, numerical control machining and 3D printing technology, digital technology is gradually applied to the virtual simulated design before irreversible operation in dental esthetic rehabilitation. Digital technology can be used in dentistry to simulate the esthetic outcome in advance, to assist communication among the dentists, patients and dental technicians, and to realize satisfactory outcome in the final restorations precisely, which, as a result, increases the clinical satisfaction. This review focuses on the application of digital virtual simulated design technology in dental esthetic rehabilitation, analyzes the current research development, deficiency and future prospects, so as to provide guidance for clinical diagnosis and treatment.


Asunto(s)
Estética Dental , Impresión Tridimensional , Diseño Asistido por Computadora , Cara , Humanos , Preparación del Diente
19.
Zhonghua Zhong Liu Za Zhi ; 43(11): 1188-1195, 2021 Nov 23.
Artículo en Chino | MEDLINE | ID: mdl-34794222

RESUMEN

Objective: To explore the serum cyclic polypeptide biomarkers for ovarian cancer diagnosis. Methods: A total of 54 patients with epithelial ovarian cancer confirmed by pathology in Cancer Hospital, Chinese Academy of Medical Sciences from March 2018 to September 2018 were selected as the study subjects, and 40 healthy women with normal examination results in the cancer screening center were selected as the control. All of the samples were randomly divided into training set and validation set at the ratio of 1∶1 with a random number. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) combined with magnetic bead technology was used for detecting peptide profiling in serum samples to screen significantly differently expressed peptides between ovarian cancer group and control group of the training set (score>5). Receiver operating characteristic (ROC) curve analysis was used to screen differential peptide peaks with area under curve (AUC) ≥0.8, sensitivity and specificity>90% in the training set and validation set. Liquid chromatography-mass spectrometry (LC-MS/MS) was further used to determine the composition of differentially expressed peptides. Results: By comparing the peptide profiles of the two groups, 102 differential peptide peaks were initially detected in the mass-to-charge ratio range of 1 000 to 10 000. ROC curve analysis showed that there were 42 differential peptide peaks with AUC ≥0.8 in both training set and validation set, 19 of which were highly expressed in ovarian cancer group, and 23 were lowly expressed. There were 15 different peptide peaks in highly expressed ovarian cancer group with sensitivity and specificity over 90%. The mass-to-charge ratios were 7 744.27, 5 913.41, 5 329.87, 4 634.21, 4 202.02, 3 879.26, 3 273.35, 3 253.79, 3 234.34, 2 950.33, 2 664.51, 2 018.38, 1 893.37, 1 498.69 and 1 287.55. There were 15 different peptide peaks in lowly expressed ovarian cancer group with sensitivity and specificity over 90%, the mass-to-charge ratios were 9 288.46, 7 759.77, 5 925.24, 4 652.77, 4 210.42, 3 887.02, 3 279.90, 3 240.82, 2 962.15, 2 932.70, 2 022.42, 1 897.16, 1 501.69, 1 337.38 and 1 290.13. No protein composition was identified in 15 different peptide peaks in lowly expressed ovarian cancer group. The two protein compositions identified in 15 different peptide peaks in highly expressed ovarian cancer group were recombinant serglycin (SRGN) and fibinogen alpha chain (FGA), the mass-to-charge ratios of which were 1 498.696 and 5 913.417, respectively. The sensitivity and specificity of the two proteins for ovarian cancer diagnosis were 100%, 100% and 90.9%, 100%, respectively. Conclusion: SRGN and FGA are highly expressed in the serum of ovarian cancer patients, which may be potential diagnostic markers for ovarian cancer.


Asunto(s)
Neoplasias Ováricas , Espectrometría de Masas en Tándem , Biomarcadores , Biomarcadores de Tumor , Carcinoma Epitelial de Ovario/diagnóstico , Cromatografía Liquida , Femenino , Humanos , Fenómenos Magnéticos , Neoplasias Ováricas/diagnóstico , Péptidos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Tecnología
20.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 56(9): 920-925, 2021 Sep 09.
Artículo en Chino | MEDLINE | ID: mdl-34496543

RESUMEN

Objective: To establish a standard method to evaluate the scanning accuracy of intraoral scanner (IOS) and to investigate six IOS's scanning accuracy and the relationship between different scan span. Methods: Five simplified six abutments full arch model were fabricated by high accuracy (5 µm) milling machine with 7075 aluminum alloy. The machining accuracy, which was verified by a coordinate measuring machine with higher accuracy (0.7 µm), was considered as the reference accuracy. The model with the highest machining accuracy was considered as the test model in IOS's scanning accuracy test, and computer-aided design (CAD) data of the model was used as the reference data. Six IOS scanned the test model 10 times with the same scanning path, obtained 60 test data. CAD data and test data were input into Geomagic Studio 2014. The preparation part above the margin of the abutments of the data was isolated and divided into 4 segments of interest: single crown, three-unit bridge, five-unit bridge, and full arch. The test data were then best-fit aligned to CAD data or each other followed by deviation analysis. Scanning trueness and precision were then calculated. Results: The mid-value of scanning trueness and precision of six IOS in single crown, three-unit bridge, five-unit bridge and full arch were 13.3-29.6 µm and 7.6-20.7 µm, 15.4-30.9 µm and 8.7-26.5 µm, 17.0-66.1 µm and 11.3-44.2 µm, 24.0-107.9 µm and 24.6-150.1 µm respectively. Conclusions: Long-span scanning can affect the accuracy of IOS to a varying extent.


Asunto(s)
Técnica de Impresión Dental , Diente , Diseño Asistido por Computadora , Arco Dental , Imagenología Tridimensional , Modelos Dentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...