RESUMEN
Metastasis contributes to the increased mortality rate of cancer, but the intricate mechanisms remain unclear. Cancer cells from a primary tumor invade nearby tissues and access the lymphatic or circulatory system. If these cells manage to survive and extravasate from the vasculature into distant tissues and ultimately adapt to survive, they will proliferate and facilitate malignant tumor formation. Traditional two-dimensional (2D) cell cultures offer a rapid and convenient method for validating the efficacy of anticancer drugs within a reasonable cost range, but their utility is limited because of tumors' high heterogeneity in vivo and spatial complexities. Three-dimensional (3D) cell cultures that mimic the physiological conditions of cancer cells in vivo have gained considerable interest. In these cultures, cells assemble into spheroids through gravity, magnetic forces, or their low-adhesion to the plates. Although these approaches address some of the limitations of 2D cultures, they often require a considerable amount of time and cost. Therefore, this study aims to enhance the effectiveness of 3D culture techniques by using microfluidic systems to provide a high-throughput and sensitive pipeline for drug screening. Using these systems, we studied the effects of lanthanide elements, which have garnered interest in cancer treatment, on spheroid formation and cell spreading. Our findings suggest that these elements alter the compactness of cell spheroids and decrease cell mobility.
Asunto(s)
Elementos de la Serie de los Lantanoides , Esferoides Celulares , Esferoides Celulares/efectos de los fármacos , Humanos , Elementos de la Serie de los Lantanoides/toxicidad , Elementos de la Serie de los Lantanoides/farmacología , Técnicas de Cultivo de Célula/métodos , Línea Celular Tumoral , Antineoplásicos/farmacología , Antineoplásicos/toxicidad , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Supervivencia Celular/efectos de los fármacos , Técnicas de Cultivo Tridimensional de Células/métodos , Ensayos de Selección de Medicamentos Antitumorales/métodosRESUMEN
Yeast plays a significant role in a variety of fields. In particular, it is extensively used as a model organism in genetics and cellular biology studies, and is employed in the production of vaccines, pharmaceuticals, and biofuels. Traditional "bulk"-based studies on yeast growth often overlook cellular variability, emphasizing the need for single-cell analysis. Micro-droplets, tiny liquid droplets with high surface-area-to-volume ratios, offer a promising platform for investigating single or a small number of cells, allowing precise control and monitoring of individual cell behaviors. Microfluidic devices, which facilitate the generation of micro-droplets, are advantageous due to their reduced volume requirements and ability to mimic in vivo micro-environments. This study introduces a custom-designed microfluidic device to encapsulate yeasts in micro-droplets under various conditions in a parallel manner. The results reveal that optimal glucose concentrations promoted yeast growth while cycloheximide and Cu2+ ions inhibited it. This platform enhances yeast cultivation strategies and holds potential for high-throughput single-cell investigations in more complex organisms.
RESUMEN
Optical paths in telescopes frequently incorporate silver mirrors for high sensitivity. Unfortunately, silver mirrors without protective coatings are susceptible to sulfurization and oxidation, compromising their quality. Even with protective layers, insufficient adhesion between the coating and the silver film can lead to peeling, exposing the silver to external environments and affecting its quality. This study aimed to identify dielectric materials with superior adhesion to silver, rendering them ideal choices for silver coating applications. By electron gun evaporation, different dielectric layers were deposited on the top and bottom of the silver film under a substrate temperature below 150 °C. These coatings were composed of materials with desired refractive indices, including aluminum oxide (Al2O3), aluminum-doped silicon, magnesium fluoride (MgF2), and other dielectrics. Following the deposition, a tape adhesion test was conducted to evaluate the bond strength of the samples. X-ray photoelectron spectroscopy (XPS) analysis was carried out to investigate the interaction between silver and its neighboring layers. The results revealed that Al2O3 and MgF2 exhibited exceptional adhesion to silver. Moreover, these multilayer coatings can effectively enhance the reflectance of silver in the visible (VIS) wavelength ranges.
RESUMEN
Alkali metal halides have long been used as scintillators for applications as sensors and detectors. Usually, a small amount of impurities are added to these inorganic materials to improve their luminescence efficiencies. We investigate the structures and luminescent properties of un-doped sodium iodide (NaI) and cesium-doped NaI (NaI:Cs) films deposited by thermal vacuum evaporation. Instead of using the toxic element thallium (Tl), we introduced cesium dopant into NaI. This is the first study for the NaI:Cs film excited by UV LED's ultraviolet C (273 nm, 4.54 eV). The luminescence spectra show two main peaks at 3.05 and 4.32/3.955 eV (for fused silica/B270 substrate), originating from the intrinsic defects and/or activator excited states and the intrinsic self-trapped excitons (STEs), respectively. In general, both Cs-doping and post-annealing processes enhance the luminescence performance of NaI films.
RESUMEN
Label-free biosensors provide an important platform for detecting chemical and biological substances without needing extra labeling agents. Unlike surface-based techniques such as surface plasmon resonance (SPR), interference, and ellipsometry, surface-enhanced Raman spectroscopy (SERS) possesses the advantage of monitoring analytes both on surfaces and in solutions. Increasing the SERS enhancement is crucial to preparing high-quality substrates without quickly losing their stability, sensitivity, and repeatability. However, fabrication methods based on wet chemistry, nanoimprint lithography, spark discharge, and laser ablation have drawbacks of waste of time, complicated processes, or nonreproducibility in surface topography. This study reports the preparation of recyclable TiO2/Ag nanoparticle (AgNP) substrates by using simple arc ion plating and direct-current (dc) magnetron sputtering technologies. The deposited anatase-phased TiO2 ensured the photocatalytic degradation of analytes. By measuring the Raman spectra of rhodamine 6G (R6G) in titrated concentrations, a limit of detection (LOD) of 10-8 M and a SERS enhancement factor (EF) of 1.01 × 109 were attained. Self-cleaning was performed via UV irradiation, and recyclability was achieved after at least five cycles of detection and degradation. The proposed TiO2/AgNP substrates have the potential to serve as eco-friendly SERS enhancers for label-free detection of various chemical and biological substances.
Asunto(s)
Nanopartículas del Metal , Plata , Nanopartículas del Metal/química , Plata/química , Espectrometría Raman/métodos , Titanio/químicaRESUMEN
The authors wish to make the following correction to this paper [...].
RESUMEN
Collective cell migration plays important roles in various physiological processes. To investigate this collective cellular movement, various wound-healing assays have been developed. In these assays, a "wound" is created mechanically, chemically, optically, or electrically out of a cellular monolayer. Most of these assays are subject to drawbacks of run-to-run variations in wound size/shape and damages to cells/substrate. Moreover, in all these assays, cells are cultured in open, static (non-circulating) environments. In this study, we reported a microfluidics-based wound-healing assay by using the trypsin flow-focusing technique. Fibroblasts were first cultured inside this chip to a cellular monolayer. Then three parallel fluidic flows (containing normal medium and trypsin solution) were introduced into the channels, and cells exposed to protease trypsin were enzymatically detached from the surface. Wounds of three different widths were generated, and subsequent wound-healing processes were observed. This assay is capable of creating three or more wounds of different widths for investigating the effects of various physical and chemical stimuli on wound-healing speeds. The effects of shear stresses, wound widths, and ß-lapachone (a wound healing-promoting chemical) on wound-healing speeds were studied. It was found that the wound-healing speed (total area healed per unit time) increased with increasing shear stress and wound width, but under a shear stress of 0.174 mPa the linear healing speed (percent area healed per unit time) was independent of the wound width. Also, the addition of ß-lapachone up to 0.5 µM did not accelerate wound healing. This microfluidics-based assay can definitely help in understanding the mechanisms of the wound-healing process and developing new wound-healing therapies.
Asunto(s)
Microfluídica , Estrés Mecánico , Cicatrización de Heridas , Animales , Células Cultivadas , HumanosRESUMEN
The wound-healing assay is commonly and widely used for investigating collective cell migration under various physical and chemical stimuli. Substrate-coating materials are shown to affect the wound-healing process in a cell-type dependent manner. However, experiment-to-experiment variations make it difficult to compare results from different assays. In this paper, a modified barrier wound-healing assay was reported for studying the wound-healing process on different substrates in one single petri dish. In short, half of a dish was covered with the tape, and coating materials, poly-l-lysine and gelatin, were applied to the surface. After peeling off the tape, half of the surface was coated with the desired material. Then a customized barrier was placed inside the dish to create the wound. The results indicated that surface coating did not affect cell proliferation/viability, and the wound-healing rate increased in coated surfaces compared to uncoated ones. The present study provides a platform for further understanding the mechanisms of substrate coating-dependent wound-healing processes.
RESUMEN
Cell migration is an important process involved in wound healing, tissue development, and so on. Many studies have been conducted to explore how certain chemicals and electric fields induce cell movements in specific directions, which are phenomena termed chemotaxis and electrotaxis, respectively. However, phototaxis, the directional migration of cells or organisms toward or away from light, is rarely investigated due to the difficulty of generating a precise and controllable light gradient. In this study, we designed and fabricated a microfluidic chip for simultaneously culturing cells and generating a blue light gradient for guiding cell migration. A concentration gradient was first established inside this chip, and by illuminating it with a blue light-emitting diode (LED), a blue light gradient was generated underneath. Cell migration in response to this light stimulus was observed. It was found that lung cancer cells migrated to the dark side of the gradient, and the intracellular reactive oxygen species (ROS) was proportional to the intensity of the blue light.
Asunto(s)
Movimiento Celular , Dispositivos Laboratorio en un Chip , Neoplasias Pulmonares/metabolismo , Células A549 , Animales , Técnicas de Cultivo de Célula/instrumentación , Diseño de Equipo , Humanos , Luz , Ratones , Células 3T3 NIH , Especies Reactivas de Oxígeno/metabolismoRESUMEN
A bare optical fiber-based biosensor is proposed for measuring the refractive index of different liquids and the binding kinetics of biomolecules to the sensor surface. This optical fiber sensor is based on the Kretschmann's configuration to attain total internal reflection (TIR) for surface plasmon resonance (SPR) excitation. One end of the bare optical fiber is coated with a gold film. By guiding the light source from the other end into the optical fiber, the light is reflected from the gold-deposited end and the surface evanescent wave is excited in the gold film-transparent material interface. Methanol and ethanol solutions with different refractive indices are used for measuring the corresponding changes in the peak values of the spectra and calculating the corresponding sensitivities. These values are experimentally determined to be in the order of 10-4~10-5 refractive index unit (RIU). Binding of proteins onto the sensor surface is also monitored in real time to obtain the binding kinetics. We believe that, in the future, this optical fiber sensor can serve as a useful biosensor for in situ measurement of allergens, antibody-antigen interactions, and even circulating tumor cells in the blood.
RESUMEN
Due to rapid industrialization and urbanization, the environment is exposed to many chemicals from natural or anthropogenic sources. The contaminants impact eco-system and human health via food chain. Animals, including humans, are likely to accumulate contaminants in their bodies from direct exposure or feeding behavior, resulting in toxicity. Therefore, evaluation of the toxicity of contaminants is an important issue. Metals are highly toxic but the toxicity depends on many factors, including the valance and the complex form of metals, the organic matter level in the environment, the reducing/oxidizing condition of the environment, and etc. Since the level of metal amount does not directly correlate to bioavailability, cell culture is usually used for toxicity evaluation. In this study, a microfluidic chip was developed to evaluate the cell toxicity from exposure to metals, copper and thallium. Compared to traditional cytotoxicity assay using static state culture with tetrazolium reagent, this microfluidic chip can generate various shear stresses by changing geometry of culture areas or flow rate. Enhancement of shear stresses could increase cell sensitivity toward metal exposure. Therefore, this platform provides a more sensitive platform for quantitative analysis of cell toxicity and could be applied to evaluate toxicity from environmental samples.
RESUMEN
This paper reports a microfluidic viscometer based on electrofluidic circuits for measuring viscosities of liquid samples. The developed micro-device consists of a polydimethylsiloxane (PDMS) layer for electrofluidic circuits, a thin PDMS membrane, another PDMS layer for sample pretreatment, and a glass substrate. As the sample flows inside the microfluidic channel, its viscosity causes flow resistance and a pressure drop along this channel. This pressure drop, in turn, generates a hydraulic pressure which deforms the PDMS membrane, causing changes in the cross-sectional area and the electrical resistance of the electrofluidic resistor. This small resistance change is then measured via the electrofluidic Wheatstone bridge to relate the measured voltage difference to the fluidic viscosity. The performance of this viscometer was first tested by flowing nitrogen gas with controllable pressures into the device. The relationship between measured voltage difference and input gas pressure was analyzed to be linear in the pressure range of 0â»15 psi. Another test using pure water indicated good linearity between measured voltage difference and flow rate in the rate range of 20â»100 µL/min. Viscosities of glycerol/water solutions with volume/volume (v/v) concentrations ranging from 0 to 30% were measured, and these values were close to those obtained using commercially available viscometers. In addition, the sample-pretreatment layer can be used to mix and/or dilute liquid samples to desired concentrations. Therefore, this microfluidic device has potential for measurements of fluidic viscosity in a fast, accurate, and high-throughput manner.
RESUMEN
Tumor Treating Fields (TTFields) in combination with chemotherapy and/or radiotherapy have been clinically reported to provide prolonged overall survival in glioblastoma patients. Alternating electric fields with frequencies of 100~300 kHz and magnitudes of 1~3 V/cm are shown to suppress the growth of cancer cells via interactions with polar molecules within dividing cells. Since it is difficult to directly measure the electric fields inside the brain, simulation models of the human head provide a useful tool for predicting the electric field distribution. In the present study, a three-dimensional finite element head model consisting of the scalp, the skull, the dura, the cerebrospinal fluid, and the brain was built to study the electric field distribution under various applied potentials and electrode configurations. For simplicity, a direct-current electric field was used in the simulation. The total power dissipation and temperature elevation due to Joule heating in different head tissues were also evaluated. Based on the results, some guidelines are obtained in designing the electrode configuration for personalized glioblastoma electrotherapy.
Asunto(s)
Neoplasias Encefálicas/terapia , Terapia por Estimulación Eléctrica/métodos , Glioblastoma/terapia , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/fisiopatología , Biología Computacional , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/estadística & datos numéricos , Electrodos , Análisis de Elementos Finitos , Glioblastoma/patología , Glioblastoma/fisiopatología , Cabeza/anatomía & histología , Humanos , Imagenología Tridimensional , Modelos Anatómicos , Fantasmas de Imagen , Medicina de Precisión/métodos , Medicina de Precisión/estadística & datos numéricosRESUMEN
Collective cell migration is important in various physiological processes such as morphogenesis, cancer metastasis and cell regeneration. Such migration can be induced and guided by different chemical and physical cues. Electrotaxis, referring to the directional migration of adherent cells under stimulus of electric fields, is believed to be highly involved in the wound-healing process. Electrotactic experiments are conventionally conducted in Petri dishes or cover glasses wherein cells are cultured and electric fields are applied. However, these devices suffer from evaporation of the culture medium, non-uniformity of electric fields and low throughput. To overcome these drawbacks, micro-fabricated devices composed of micro-channels and fluidic components have lately been applied to electrotactic studies. Microfluidic devices are capable of providing cells with a precise micro-environment including pH, nutrition, temperature and various stimuli. Therefore, with the advantages of reduced cell/reagent consumption, reduced Joule heating and uniform and precise electric fields, microfluidic chips are perfect platforms for observing cell migration under applied electric fields. In this paper, I review recent developments in designing and fabricating microfluidic devices for studying electrotaxis, aiming to provide critical updates in this rapidly-growing, interdisciplinary field.
RESUMEN
Endogenous electric field is known to play important roles in the wound-healing process, mainly through its effects on protein synthesis and cell migration. Many clinical studies have demonstrated that electrical stimulation (ES) with steady direct currents is beneficial to accelerating wound-healing, even though the underlying mechanisms remain unclear. In the present study, a three-dimensional finite element wound model was built to optimize the electrode configuration in ES. Four layers of the skin, stratum corneum, epidermis, dermis, and subcutis, with defined thickness and electrical properties were modeled. The main goal was to evaluate the distributions of exogenous electric fields delivered with direct current (DC) stimulation using different electrode configurations such as sizes and positions. Based on the results, some guidelines were obtained in designing the electrode configuration for applications of clinical ES.
Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Modelos Biológicos , Piel , Cicatrización de Heridas , Animales , Terapia por Estimulación Eléctrica/instrumentación , Electrodos , Humanos , Piel/lesiones , Piel/metabolismo , Piel/patologíaRESUMEN
BACKGROUND: Directed cell migration can be driven by a range of external stimuli, such as spatial gradients of: chemical signals (chemotaxis); adhesion sites (haptotaxis); or temperature (thermotaxis). Continuum models of cell migration typically include a diffusion term to capture the undirected component of cell motility and an advection term to capture the directed component of cell motility. However, there is no consensus in the literature about the form that the advection term takes. Some theoretical studies suggest that the advection term ought to include receptor saturation effects. However, others adopt a much simpler constant coefficient. One of the limitations of including receptor saturation effects is that it introduces several additional unknown parameters into the model. Therefore, a relevant research question is to investigate whether directed cell migration is best described by a simple constant tactic coefficient or a more complicated model incorporating saturation effects. RESULTS: We study directed cell migration using an experimental device in which the directed component of the cell motility is driven by a spatial gradient of electric potential, which is known as electrotaxis. The electric field (EF) is proportional to the spatial gradient of the electric potential. The spatial variation of electric potential across the experimental device varies in such a way that there are several subregions on the device in which the EF takes on different values that are approximately constant within those subregions. We use cell trajectory data to quantify the motion of 3T3 fibroblast cells at different locations on the device to examine how different values of the EF influences cell motility. The undirected (random) motility of the cells is quantified in terms of the cell diffusivity, D, and the directed motility is quantified in terms of a cell drift velocity, v. Estimates D and v are obtained under a range of four different EF conditions, which correspond to normal physiological conditions. Our results suggest that there is no anisotropy in D, and that D appears to be approximately independent of the EF and the electric potential. The drift velocity increases approximately linearly with the EF, suggesting that the simplest linear advection term, with no additional saturation parameters, provides a good explanation of these physiologically relevant data. CONCLUSIONS: We find that the simplest linear advection term in a continuum model of directed cell motility is sufficient to describe a range of different electrotaxis experiments for 3T3 fibroblast cells subject to normal physiological values of the electric field. This is useful information because alternative models that include saturation effects involve additional parameters that need to be estimated before a partial differential equation model can be applied to interpret or predict a cell migration experiment.
Asunto(s)
Ensayos de Migración Celular , Movimiento Celular , Electricidad , Modelos Biológicos , Células 3T3 , Animales , Difusión , RatonesRESUMEN
Optical biosensors provide a platform for qualitatively and quantitatively analyzing various biomolecular interactions. In addition to advantages such as label-free and high-throughput detection, these devices are also capable of measuring real-time binding curves in response to changes in optical properties of biomolecules. These kinetic data may be fitted to models to extract binding affinities such as association rates, dissociation rates, and equilibrium dissociation constants. In these biosensors, one of the binding pair is usually immobilized on a solid substrate for capturing the other. Due to the nature of these surface-based methods, mass transport effects and immobilization heterogenetity may cause problems when fitting the kinetic curves with the simple one-to-one Langmuir model. Here real-time binding curves of various antibody-antigen reactions were obtained by using an ellipsometry-based biosensor, and the results were fitted to the simple one-to-one model as well as a more sophisticated approach. The results show that the one-to-two model fitted much better to the curves than the one-to-one model. The two-site model may be explained by assuming two immobilization configurations on the surface. In summary, in fitting real-time curves obtained from optical biosensors, more sophisticated models are usually required to take surface-related issues, such as immobilization heterogenetity and mass transport effects within targets, into account.
RESUMEN
Carbohydrates present on cell surfaces mediate cell behavior through interactions with other biomolecules. Due to their structural complexity, diversity, and heterogeneity, it is difficult to fully characterize a variety of carbohydrates and their binding partners. As a result, novel technologies for glycomics applications have been developed, including carbohydrate microarrays and label-free detection methods. In this paper, we report using the combination of oligosaccharide microarrays and the label-free oblique-incidence reflectivity difference (OI-RD) microscopy for real-time characterization of oligosaccharide binding proteins. Aminated human milk oligosaccharides were immobilized on epoxy-coated glass substrates as microarrays for reactions with Family 1 of solute binding proteins from Bifidobacterium longum subsp. infantis (B. infantis). Binding affinities of these protein-oligosaccharide interactions showed preferences of Family 1 of solute binding proteins to host glycans, which helps in characterizing the complex process of human milk oligosaccharides foraging by B. infantis.
RESUMEN
Microarrays of biological molecules such as DNAs, proteins, carbohydrates, and small molecules provide a high-throughput platform for screening tens of thousands of biomolecular interactions simultaneously, facilitating the functional characterization of these biomolecules in areas of genomics, proteomics, glycomics, and cytomics. Routinely, analysis of binding reactions between solution-phased probes and surface-immobilized targets involves some kinds of fluorescence-based detection methods. Even though these methods have advantages of high sensitivity and wide dynamic range, labeling probes and/or targets inevitably changes their innate properties and in turn affects probe-target interactions in often uncharacterized ways. Therefore, in recent years, various label-free sensing technologies have been developed for characterizing biomolecular interactions in microarray format. These biosensors, to a certain extent, take the place of fluorescent methods by providing a comparable sensitivity as well as retaining the conformational and functional integrality of biomolecules to be investigated. More importantly, some of these biosensors are capable of real-time monitoring probe-target interactions, providing the binding affinities of these reactions. Using label-free biosensors in microarrays has become a current trend in developing high-throughput screening platforms for drug discoveries and applications in all areas of "-omics." This article is aimed to provide principles and recent developments in label-free sensing technologies applicable to microarrays, with special attentions being paid to surface plasmon resonance microscopy and oblique-incidence reflectivity difference microscopy.
Asunto(s)
Análisis por Micromatrices/métodos , Coloración y Etiquetado , Adsorción , Procesamiento de Imagen Asistido por Computador , Cinética , Magnetismo , Resonancia por Plasmón de SuperficieRESUMEN
Collective cell migration plays important roles in many physiological processes such as embryonic development, tissue repair, and angiogenesis. A "wound" occurs when epithelial cells are lost and/or damaged due to some external factors, and collective cell migration takes place in the following wound-healing process. To study this cellular behavior, various kinds of wound-healing assays are developed. In these assays, a "wound," or a "cell-free region," is created in a cell monolayer mechanically, chemically, optically, or electrically. These assays are useful tools in studying the effects of certain physical or chemical stimuli on the wound-healing process. Most of these methods have disadvantages such as creating wounds of different sizes or shapes, yielding batch-to-batch variation, and damaging the coating of the cell culture surface. In this study, we used ultraviolet (UV) lights to selectively kill cells and create a wound out of a cell monolayer. A comparison between the current assay and the traditional scratch assay was made, indicating that these two methods resulted in similar wound-healing rates. The advantages of this UV-created wound-healing assay include fast and easy procedure, high throughput, and no direct contact to cells.