Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nat Med ; 29(12): 3203-3211, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37884028

RESUMEN

Anopheles stephensi, an Asian malaria vector, continues to expand across Africa. The vector is now firmly established in urban settings in the Horn of Africa. Its presence in areas where malaria resurged suggested a possible role in causing malaria outbreaks. Here, using a prospective case-control design, we investigated the role of An. stephensi in transmission following a malaria outbreak in Dire Dawa, Ethiopia in April-July 2022. Screening contacts of patients with malaria and febrile controls revealed spatial clustering of Plasmodium falciparum infections around patients with malaria in strong association with the presence of An. stephensi in the household vicinity. Plasmodium sporozoites were detected in these mosquitoes. This outbreak involved clonal propagation of parasites with molecular signatures of artemisinin and diagnostic resistance. To our knowledge, this study provides the strongest evidence so far for a role of An. stephensi in driving an urban malaria outbreak in Africa, highlighting the major public health threat posed by this fast-spreading mosquito.


Asunto(s)
Anopheles , Malaria Falciparum , Malaria , Animales , Humanos , Malaria/epidemiología , Malaria/parasitología , Anopheles/parasitología , Mosquitos Vectores/parasitología , Malaria Falciparum/diagnóstico , Malaria Falciparum/epidemiología , Etiopía/epidemiología
2.
MMWR Morb Mortal Wkly Rep ; 72(36): 973-978, 2023 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-37676839

RESUMEN

Eight cases of locally acquired, mosquito-transmitted (i.e., autochthonous) Plasmodium vivax malaria, which has not been reported in the United States since 2003, were reported to CDC from state health departments in Florida and Texas during May 18-July 17, 2023. As of August 4, 2023, case surveillance, mosquito surveillance and control activities, and public outreach and education activities continue in both states. U.S. clinicians need to consider a malaria diagnosis in patients with unexplained fever, especially in areas where autochthonous malaria has been recently reported, although the risk for autochthonous malaria in the United States remains very low. Prompt diagnosis and treatment of malaria can prevent severe disease or death and limit ongoing transmission to local Anopheles mosquitoes and other persons. Preventing mosquito bites and controlling mosquitoes at home can prevent mosquitoborne diseases, including malaria. Before traveling internationally to areas with endemic malaria, travelers should consult with a health care provider regarding recommended malaria prevention measures, including potentially taking malaria prophylaxis. Malaria is a nationally notifiable disease; continued reporting of malaria cases to jurisdictional health departments and CDC will also help ensure robust surveillance to detect and prevent autochthonous malaria in the United States.


Asunto(s)
Brotes de Enfermedades , Malaria , Animales , Humanos , Texas/epidemiología , Florida/epidemiología , Malaria/epidemiología , Malaria/prevención & control , Personal de Salud
3.
J Med Entomol ; 60(3): 535-545, 2023 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-36779801

RESUMEN

Malaria is responsible for over 435,000 deaths annually, mostly occurring in sub-Saharan Africa. Detecting Plasmodium spp. sporozoites (spzs) in the salivary glands of Anopheles (Diptera: Culicidae) vectors with circumsporozoite enzyme-linked immunosorbent assay (csELISA) is an important surveillance method. However, current technological advances are intellectual property and often require of distribution and highly trained users. The transition into paper-based rapid plataforms would allow for decentralization of survillance, especially in areas where it was virtually eliminated. The addition of bio-based materials have shown the potential to improve binding of target antigens, while being widely available. Here, we evaluate the use of chitosan and cellulose nanocrystals (CNC) as antibody carriers and substrate coatings on 96-well plates and on wax hydrophobized paper plates for the detection of Plasmodium falciparum (Pf), P. vivax VK210 (Pv210), and P. vivax VK247 (Pv247). To further improve the user-friendliness of the paper plates a quantitative photograph image-based color analysis was done. Interactions between the materials and the assay antibodies were studied by quartz crystal microbalance with dissipation monitoring (QCM-D). Overall, the addition of chitosan increased the interaction with antibodies and enhanced signaling in all tests. This work demonstrated that the adaptation of a PcsELISA shows potential as a cost-effective alternative assay platform easily adaptable in deployable testing sites that also showed reduction in reagent volumes by 80% and assay run time by seventh. While dipstick assays were previously developed, paper-based assays are a cost-effective and field-deployable alternative, reducing volumes of reagents that could be used in malaria control and elimination settings.


Asunto(s)
Anopheles , Quitosano , Malaria , Plasmodium , Animales , Esporozoítos/química , Esporozoítos/metabolismo , Plasmodium vivax , Proteínas Protozoarias/análisis , Mosquitos Vectores , Plasmodium falciparum , Anopheles/metabolismo
4.
Malar J ; 20(1): 377, 2021 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-34556130

RESUMEN

BACKGROUND: Plasmodium spp. sporozoite rates in mosquitoes are used to better understand malaria transmission intensity, the relative importance of vector species and the impact of interventions. These rates are typically estimated using an enzyme-linked immunosorbent assay (ELISA) utilizing antibodies against the circumsporozoite protein of Plasmodium falciparum, Plasmodium vivax VK210 (P. vivax210) or P. vivax VK247 (P. vivax247), employing assays that were developed over three decades ago. The ELISA method requires a separate assay plate for each analyte tested and can be time consuming as well as requiring sample volumes not always available. The bead-based multiplex platform allows simultaneous measurement of multiple analytes and may improve the lower limit of detection for sporozoites. METHODS: Recombinant positive controls for P. falciparum, P. vivax210 and P. vivax247 and previously developed circumsporozoite (cs) ELISA antibodies were used to optimize conditions for the circumsporozoite multiplex bead assay (csMBA) and to determine the detection range of the csMBA. After optimizing assay conditions, known amounts of sporozoites were used to determine the lower limit of detection for the csELISA and csMBA and alternate cut-off measures were applied to demonstrate how cut-off criteria can impact lower limits of detection. Sporozoite rates from 1275 mosquitoes collected in Madagascar and 255 mosquitoes collected in Guinea were estimated and compared using the established csELISA and newly optimized csMBA. All mosquitoes were tested (initial test), and those that were positive were retested (retest). When sufficient sample volume remained, an aliquot of homogenate was boiled and retested (boiled retest), to denature any heat-unstable cross-reactive proteins. RESULTS: Following optimization of the csMBA, the lower limit of detection was 25 sporozoites per mosquito equivalent for P. falciparum, P. vivax210 and P. vivax247 whereas the lower limits of detection for csELISA were found to be 1400 sporozoites for P. falciparum, 425 for P. vivax210 and 1650 for P. vivax247. Combined sporozoite rates after re-testing of samples that initially tested positive for Madagascar mosquitoes by csELISA and csMBA were 1.4 and 10.3%, respectively, and for Guinea mosquitoes 2% by both assays. Boiling of samples followed by csMBA resulted in a decrease in the Madagascar sporozoite rate to 2.8-4.4% while the Guinea csMBA sporozoite rate remained at 2.0%. Using an alternative csMBA cut-off value of median fluorescence intensity (MFI) of 100 yielded a sporozoite rate after confirmational testing of 3.7% for Madagascar samples and 2.0% for Guinea samples. Whether using csMBA or csELISA, the following steps may help minimize false positives: specimens are appropriately stored and bisected anterior to the thorax-abdomen junction, aliquots of homogenate are boiled and retested following initial testing, and an appropriate cut-off value is determined. CONCLUSIONS: The csMBA is a cost-comparable and time saving alternative to the csELISA and may help eliminate false negatives due to a lower limit of detection, thus increasing sensitivity over the csELISA. The csMBA expands the potential analyses that can be done with a small volume of sample by allowing multiplex testing where analytes in addition to P. falciparum, P. vivax210 and P. vivax247 can be added following optimization.


Asunto(s)
Anopheles/parasitología , Mosquitos Vectores/parasitología , Plasmodium falciparum/aislamiento & purificación , Plasmodium vivax/aislamiento & purificación , Proteínas Protozoarias/aislamiento & purificación , Esporozoítos/aislamiento & purificación , Animales , Ensayo de Inmunoadsorción Enzimática/métodos , Guinea , Madagascar
5.
Parasit Vectors ; 14(1): 473, 2021 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-34526109

RESUMEN

BACKGROUND: In characterizing malaria epidemiology, measuring mosquito infectiousness informs the entomological inoculation rate, an important metric of malaria transmission. PCR-based methods have been touted as more sensitive than the current "gold-standard" circumsporozoite (CSP) ELISA. Wider application of PCR-based methods has been limited by lack of specificity for the infectious sporozoite stage. We compared a PCR method for detecting the parasite's mitochondrial (mt) cytochrome oxidase I (COX-I) gene with ELISA for detecting circumsporozoite protein for identification of different life stages of the parasite during development within a mosquito. METHODS: A PCR-based method targeting the Plasmodium mt COX-I gene was compared with the CSP ELISA method to assess infectivity in Anopheles arabiensis colony mosquitoes fed on blood from patients infected with Plasmodium vivax. Mosquitoes were tested at six post-infection time points (days 0.5, 1, 6, 9, 12, 15). The head and thorax and the abdomen for each specimen were tested separately with each method. Agreement between methods at each infection stage was measured using Cohen's kappa measure of test association. RESULTS: Infection status of mosquitoes was assessed in approximately 90 head/thorax and 90 abdomen segments at each time point; in total, 538 head/thorax and 534 abdomen segments were tested. In mosquitoes bisected after 0.5, 1, and 6 days post-infection (dpi), the mt COX-I PCR detected Plasmodium DNA in both the abdomen (88, 78, and 67%, respectively) and head/thorax segments (69, 60, and 44%, respectively), whilst CSP ELISA detected sporozoites in only one abdomen on day 6 post-infection. PCR was also more sensitive than ELISA for detection of Plasmodium in mosquitoes bisected after 9, 12, and 15 dpi in both the head and thorax and abdomen. There was fair agreement between methods for time points 9-15 dpi (κ = 0.312, 95% CI: 0.230-0.394). CONCLUSIONS: The mt COX-I PCR is a highly sensitive, robust method for detecting Plasmodium DNA in mosquitoes, but its limited Plasmodium life-stage specificity cannot be overcome by bisection of the head and thorax from the abdomen prior to PCR. Thus, the mt COX-I PCR is a poor candidate for identifying infectious mosquitoes.


Asunto(s)
Anopheles/parasitología , Ensayo de Inmunoadsorción Enzimática/normas , Estadios del Ciclo de Vida/genética , Plasmodium vivax/genética , Reacción en Cadena de la Polimerasa/normas , Esporozoítos/genética , Animales , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Plasmodium vivax/inmunología , Reacción en Cadena de la Polimerasa/métodos , Esporozoítos/inmunología
6.
Malar J ; 20(1): 25, 2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-33413398

RESUMEN

BACKGROUND: Malaria is a top cause of mortality on the island nation of Madagascar, where many rural communities rely on subsistence agriculture and livestock production. Understanding feeding behaviours of Anopheles in this landscape is crucial for optimizing malaria control and prevention strategies. Previous studies in southeastern Madagascar have shown that Anopheles mosquitoes are more frequently captured within 50 m of livestock. However, it remains unknown whether these mosquitoes preferentially feed on livestock. Here, mosquito blood meal sources and Plasmodium sporozoite rates were determined to evaluate patterns of feeding behaviour in Anopheles spp. and malaria transmission in southeastern Madagascar. METHODS: Across a habitat gradient in southeastern Madagascar 7762 female Anopheles spp. mosquitoes were collected. Of the captured mosquitoes, 492 were visibly blood fed and morphologically identifiable, and a direct enzyme-linked immunosorbent assay (ELISA) was used to test for swine, cattle, chicken, human, and dog blood among these specimens. Host species identification was confirmed for multiple blood meals using PCR along with Sanger sequencing. Additionally, 1,607 Anopheles spp. were screened for the presence of Plasmodium falciparum, P. vivax-210, and P. vivax 247 circumsporozoites (cs) by ELISA. RESULTS: Cattle and swine accounted, respectively, for 51% and 41% of all blood meals, with the remaining 8% split between domesticated animals and humans. Of the 1,607 Anopheles spp. screened for Plasmodium falciparum, Plasmodium vivax 210, and Plasmodium vivax 247 cs-protein, 45 tested positive, the most prevalent being P. vivax 247, followed by P. vivax 210 and P. falciparum. Both variants of P. vivax were observed in secondary vectors, including Anopheles squamosus/cydippis, Anopheles coustani, and unknown Anopheles spp. Furthermore, evidence of coinfection of P. falciparum and P. vivax 210 in Anopheles gambiae sensu lato (s.l.) was found. CONCLUSIONS: Here, feeding behaviour of Anopheles spp. mosquitoes in southeastern Madagascar was evaluated, in a livestock rich landscape. These findings suggest largely zoophagic feeding behaviors of Anopheles spp., including An. gambiae s.l. and presence of both P. vivax and P. falciparum sporozoites in Anopheles spp. A discordance between P. vivax reports in mosquitoes and humans exists, suggesting high prevalence of P. vivax circulating in vectors in the ecosystem despite low reports of clinical vivax malaria in humans in Madagascar. Vector surveillance of P. vivax may be relevant to malaria control and elimination efforts in Madagascar. At present, the high proportion of livestock blood meals in Madagascar may play a role in buffering (zooprophylaxis) or amplifying (zoopotentiation) the impacts of malaria. With malaria vector control efforts focused on indoor feeding behaviours, complementary approaches, such as endectocide-aided vector control in livestock may be an effective strategy for malaria reduction in Madagascar.


Asunto(s)
Anopheles/fisiología , Mosquitos Vectores/fisiología , Plasmodium falciparum/aislamiento & purificación , Plasmodium vivax/aislamiento & purificación , Animales , Anopheles/parasitología , Conducta Alimentaria , Femenino , Madagascar , Mosquitos Vectores/parasitología , Especificidad de la Especie
7.
BMC Biotechnol ; 9: 91, 2009 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-19849838

RESUMEN

BACKGROUND: When rearing morphologically indistinguishable laboratory strains concurrently, the threat of unintentional genetic contamination is constant. Avoidance of accidental mixing of strains is difficult due to the use of common equipment, technician error, or the possibility of self relocation by adult mosquitoes ("free fliers"). In many cases, laboratory strains are difficult to distinguish because of morphological and genetic similarity, especially when laboratory colonies are isolates of certain traits from the same parental strain, such as eye color mutants, individuals with certain chromosomal arrangements or high levels of insecticide resistance. Thus, proving genetic integrity could seem incredibly time-consuming or impossible. On the other hand, lacking proof of genetically isolated laboratory strains could question the validity of research results. RESULTS: We present a method for establishing authentication matrices to routinely distinguish and confirm that laboratory strains have not become physically or genetically mixed through contamination events in the laboratory. We show a specific example with application to Anopheles gambiae sensu stricto strains at the Malaria Research and Reference Reagent Resource Center. This authentication matrix is essentially a series of tests yielding a strain-specific combination of results. CONCLUSION: These matrix-based methodologies are useful for several mosquito and insect populations but must be specifically tailored and altered for each laboratory based on the potential contaminants available at any given time. The desired resulting authentication plan would utilize the least amount of routine effort possible while ensuring the integrity of the strains.


Asunto(s)
Anopheles/clasificación , Análisis de Secuencia de ADN/métodos , Animales , Anopheles/anatomía & histología , Anopheles/genética , Genes de Insecto , Genotipo , Fenotipo , Reacción en Cadena de la Polimerasa/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...