Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Clin Res Cardiol ; 113(2): 276-287, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37870627

RESUMEN

OBJECTIVES: Systemic inflammatory response syndrome (SIRS) is a common finding after cardiovascular interventions. Data on the incidence of SIRS and its impact on outcome in patients undergoing transcatheter edge-to-edge mitral valve repair (MV-TEER) for mitral regurgitation (MR) is lacking. METHODS: From January 2013 to December 2020, 373 patients with moderate or severe MR undergoing MV-TEER were included. SIRS was defined as at least two of the following criteria within 48 h after the procedure: leucocyte count > 12.0 or < 4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 bpm and temperature > 38.0 °C or < 36.0 °C. The primary endpoint was 3-years all-cause mortality. RESULTS: SIRS was observed in 49.6% (185/373) of patients. Patients who developed SIRS presented more frequently with NYHA III/IV at baseline [SIRS: 82.4% (149/185) vs. no SIRS: 79.0% (147/188); p = 0.029]. Patients who developed SIRS spent more days on ICU (p < 0.001) and overall length of stay was longer (p < 0.001). Relevant residual MR, defined as MR ≥ III in-hospital, was present more often in patients who developed SIRS [SIRS: 11.3% (20/177) vs. no SIRS: 3.93% (7/178), p = 0.036]. At 3 years, all-cause mortality in the entire population was 33.5% (125/373) with an increased all-cause mortality in patients with SIRS compared to patients without SIRS (HR 1.49, [CI 95% 1.04, 2.13]; p = 0.0264). In the multivariate analysis development of SIRS (HR 1.479 [CI 95% 1.016, 2.154]; p = 0.041) was identified as predictor for 3-years all-cause mortality. CONCLUSIONS: SIRS is a common finding after MV-TEER occurring in approximately half of patients. SIRS after MV-TEER was associated with a longer in-hospital stay. In addition, we observed an increased 3-years all-cause mortality in patients with SIRS.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Incidencia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Síndrome de Respuesta Inflamatoria Sistémica/diagnóstico , Síndrome de Respuesta Inflamatoria Sistémica/epidemiología , Síndrome de Respuesta Inflamatoria Sistémica/etiología , Frecuencia Cardíaca , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
2.
Artículo en Inglés | MEDLINE | ID: mdl-38065713

RESUMEN

BACKGROUND: Data on systemic inflammatory response syndrome (SIRS) after transcatheter aortic valve implantation (TAVI) are scarce and limited to small cohorts. We aimed to investigate its incidence and mid-term impact in a large cohort of TAVI patients. METHODS: From January 2018 to December 2020, 717 patients with severe aortic valve stenosis undergoing TAVI were included. SIRS was defined as fulfilling at least two of the following criteria within 48 h from the procedure: leucocyte count >12.0 or <4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 beats per minute and temperature > 38.0 °C or <36.0 °C. Clinical endpoints were 1-year rehospitalization for chronic heart failure (CHF) and 2-years all-cause mortality. Event rates during follow-up were calculated as Kaplan-Meier estimates. RESULTS: SIRS developed in 56.3 % (404/717) of patients after TAVI. SIRS occurred more frequently in patients with post-dilatation (SIRS 34.7 % (140/404) vs. no SIRS 23.3 % (73/313); p < 0.001) and major vascular complications (SIRS 16.1 % (65/404) vs. no SIRS 8.6 % (27/313); p = 0.004). Further, ICU days were more in patients who developed SIRS (SIRS 1.56 ± 1.50 days vs. no SIRS 1.22 ± 1.02 days; p = 0.001). At 2-years, all-cause mortality in the entire population was 23.9 %. However, there was no difference in CHF at 1-year (5.9 % vs. 4.1 %; log-rank = 0.347) nor in all-cause mortality at 2-years (22.0 % vs. 26.2 %; log-rank = 0.690) between the groups. CONCLUSIONS: SIRS is a common finding after TAVI, which may prolong hospital stay but is without effect on mortality during 2-years follow-up.

3.
Catheter Cardiovasc Interv ; 102(7): 1301-1310, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37877190

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PPI) remains a relevant complication after transcatheter aortic valve implantation (TAVI) and its impact on outcome remains controversial. AIMS: This study aimed to analyze the effects of implantation depth on PPI at 30 days and assess its impact on outcome with the balloon-expandable Sapien 3 (S3) prosthesis. METHODS: Between 2014 and 2018, 849 patients without previous pacemaker undergoing transfemoral TAVI with the S3 were included. Prosthesis implantation depth was measured and divided into Quintiles. An ordinal logistic regression was used to assess its association with PPI, while a multivariate logistic regression was performed to identify predictors of PPI. Survival analyses were performed with the Kaplan-Meier method and a multivariable Cox regression was performed to ascertain the impact of PPI on mortality. RESULTS: Overall, incidence of PPI at 30 days was 9.7%. Implantation depth decreased consistently from a median of 6.7 mm [5.55-8.00] in 2014 to 2.7 mm [2.30-3.50] in 2018 (p < 0.001). When considering Quintiles of implantation depth, incidence of PPI was significantly higher in upper Quintiles and risk for PPI was significantly lower for the 1. Quintile compared to the 5. Quintile (OR: 0.34, 95% CI: [0.16-0.73]; p = 0.003). In the adjusted multivariable logistic regression implantation depth persisted ad independent predictor of PPI at 30 days. Patients requiring PPI at 30 days displayed significantly higher mortality at 4 years compared to patients without PPI (49.5% vs. 40.0%; log-rank = 0.022). In a multivariate analysis, increased logistic EuroScore, diabetes mellitus, and history of atrial fibrillation, were independent predictors of all-cause mortality at 2 years. CONCLUSIONS: Higher prosthesis implantation relative to the virtual aortic annulus was significantly associated with reduced risk for PPI at 30 days. Patients with PPI at 30 days exhibited higher mortality during follow-up, however, only logistic EuroScore, diabetes mellitus, and history of atrial fibrillation were identified as independent predictors of mortality at 2 years.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Diabetes Mellitus , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
4.
J Echocardiogr ; 21(2): 65-73, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36227498

RESUMEN

AIMS: Echocardiographic measurement of left ventricular function using a user-friendly automated three-dimensional algorithm is highly attractive as it promises quick and accurate diagnosis, circumventing limitations associated with visual estimation or manual biplane measurements. We sought to assess the feasibility and correlation of such automated analysis with clinically established methods. METHODS: A total of 198 patients undergoing transthoracic echocardiography (TTE) with assessment of left ventricular parameters by automated software algorithm (Philips 3D-Heartmodel; 3D-HM) which additionally had either left ventricular angiography (LVA) or cardiac magnetic resonance (CMR) within 24 h of the TTE examination were analyzed. Left ventricular parameters (left ventricular end-diastolic volume, LVEDV, left ventricular end-systolic volume, LVESV as well as left ventricular ejection fraction, LVEF) were compared between 3D-HM, CMR and LVA. RESULTS: Correlation of left ventricular measurements was overall good to excellent and stronger for CMR (EF r = 0.824) than for LVA (EF r = 0.746). Unexperienced and expert clinicians yielded comparable good results. For CMR, highest correlation was detected in patients with BMI < 25 and excellent image quality. High agreement was seen between 3D-HM and CMR or LVA when stratifying patients according to heart failure categories. CONCLUSIONS: Echocardiographic quantification of left ventricular parameters using a software-based algorithm correlated well with established invasive and non-invasive modalities in the clinical setting, even for unexperienced clinicians. Such automated approaches are promising as they allow a reliable, more observer-independent as well as reproducible assessment of left ventricular function.


Asunto(s)
Ecocardiografía Tridimensional , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Algoritmos , Ventrículos Cardíacos/diagnóstico por imagen , Ecocardiografía
6.
PLoS One ; 15(12): e0242989, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33270674

RESUMEN

BACKGROUND: The aim of this study was to assess different amyloid beta subspecies' effects on behaviour and cognition in mice and their interaction with isoflurane anaesthesia. METHODS: After governmental approval, cannulas were implanted in the lateral cerebral ventricle. After 14 days the mice were randomly intracerebroventricularly injected with Aß 1-40 (Aß40), Aß 1-42 (Aß42), 3NTyr10-Aß (Aß nitro), AßpE3-42 (Aß pyro), or phosphate buffered saline. Four days after the injection, 30 mice (6 animals per subgroup) underwent general anaesthesia with isoflurane. A "sham" anaesthetic procedure was performed in another 30 mice (6 animals per subgroup, 10 subgroups in total). During the next eight consecutive days a blinded assessor evaluated behavioural and cognitive performance using the modified hole-board test. Following the testing we investigated 2 brains per subgroup for insoluble amyloid deposits using methoxy staining. We used western blotting in 4 brains per subgroup for analysis of tumour-necrosis factor alpha, caspase 3, glutamate receptors NR2B, and mGlu5. Data were analysed using general linear modelling and analysis of variance. RESULTS: Aß pyro improved overall cognitive performance (p = 0.038). This cognitive improvement was reversed by isoflurane anaesthesia (p = 0.007), presumably mediated by decreased exploratory behaviour (p = 0.022 and p = 0.037). Injection of Aß42 was associated with increased anxiety (p = 0.079). Explorative analysis on a limited number of brains did not reveal insoluble amyloid deposits or differences in the expression of tumour-necrosis factor alpha, NR2B, mGlu5, or caspase 3. CONCLUSIONS: Testing cognitive performance after intracerebroventricular injection of different amyloid beta subspecies revealed that Aß pyro might be less harmful, which was reversed by isoflurane anaesthesia. There is minor evidence for Aß42-mediated neurotoxicity. Preliminary molecular analysis of biomarkers did not clarify pathophysiological mechanisms.


Asunto(s)
Péptidos beta-Amiloides/toxicidad , Anestésicos por Inhalación/farmacología , Cognición/efectos de los fármacos , Isoflurano/farmacología , Síndromes de Neurotoxicidad/etiología , Enfermedad de Alzheimer/fisiopatología , Péptidos beta-Amiloides/administración & dosificación , Péptidos beta-Amiloides/química , Animales , Conducta Animal/efectos de los fármacos , Encéfalo/efectos de los fármacos , Encéfalo/metabolismo , Caspasa 3/metabolismo , Conducta Exploratoria/efectos de los fármacos , Inyecciones Intraventriculares , Masculino , Ratones Endogámicos C57BL , Fragmentos de Péptidos/administración & dosificación , Fragmentos de Péptidos/metabolismo , Fragmentos de Péptidos/toxicidad , Receptor del Glutamato Metabotropico 5/metabolismo , Receptores de N-Metil-D-Aspartato/metabolismo , Factor de Necrosis Tumoral alfa/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA