Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Implant Dent ; 10(1): 9, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38372934

RESUMEN

PURPOSE: Tricalcium phosphate (TCP) has osteoconductive ability and reportedly offers similar clinical results as autogenous bone grafts in dental implant treatment. However, few reports quantify temporal changes in augmented bone volume after sinus augmentation. We aimed to establish a three-dimensional (3D) quantification method to assess bone volume after sinus augmentation and to evaluate biocompatibility of the TCP plate. METHODS: Maxillary sinus floor augmentation was performed employing the lateral window technique, and plate-shaped ß-TCP (TCP plate) was used instead of granular bone grafting materials. After lifting the sinus membrane, the TCP plate was inserted and supported by dental implants or micro-screws. The changes in bone volumes in the maxillary sinus before and after surgery were recorded using cone-beam computed tomography, saved as Digital Imaging and Communications in Medicine-formatted files, and transformed to Standard Triangle Language (STL)-formatted files. Pre- and post-operative STL data of bone volume were superimposed, and the augmented bone volume was calculated. Moreover, changes in bone volumes, TCP plate resorption rates, and bone heights surrounding the implants were three dimensionally quantified. RESULTS: Fifteen implants in nine subjects were included in this study. TCP plates secured long-term space making, with results similar to those of granular bone substitutes. Newly formed bone was identified around the implant without bone graft material. TCP plate was absorbed and gradually disappeared. CONCLUSIONS: A novel 3D quantification method was established to evaluate changes in bone volume. Clinical application of TCP plate in sinus augmentation could be a better procedure in terms of prognosis and safety.


Asunto(s)
Sustitutos de Huesos , Fosfatos de Calcio , Elevación del Piso del Seno Maxilar , Humanos , Sustitutos de Huesos/uso terapéutico , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/cirugía , Placas Óseas
2.
Materials (Basel) ; 15(24)2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-36556608

RESUMEN

Bone-substitute materials are essential in dental implantology. We prepared collagen (Col)/hydroxyapatite (Hap)/acidic gelatin (AG)/basic fibroblast growth factor (b-FGF) constructs with enhanced bone-forming capability. The Col/Hap apatite composites were prepared by immersing Col sponges alternately in calcium and phosphate ion solutions five times, for 20 and 60 min, respectively. Then, the sponges were heated to 56 °C for 48 h. Scanning electron microscopy/energy-dispersive X-ray spectroscopy, Fourier-transform infrared spectroscopy, and X-ray diffraction analyses showed that the Col/Hap composites contained poorly crystalline Hap precipitates on the Col matrix. Col/Hap composite granules were infiltrated by AG, freeze-dried, and immersed in b-FGF solution. The wet quaternary constructs were implanted in rat cranial bone defects for 8 weeks, followed by soft X-ray measurements and histological analysis. Animal studies have shown that the constructs moderately increase bone formation in cranial bone defects. We found that an alternate immersion time of 20 min led to the greatest bone formation (p < 0.05). Constructs placed inside defects slightly extend the preexisting bone from the defect edges and lead to the formation of small island-like bones inside the defect, followed by disappearance of the constructs. The combined use of Col, Hap, AG, and b-FGF might bring about novel bone-forming biomaterials.

3.
Materials (Basel) ; 15(9)2022 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-35591709

RESUMEN

Osteo-conductive bone substitute materials are required in dentistry. In this study, highly pressed nano-hydroxyapatite/collagen (P-nHAP/COL) composites were formed by a hydraulic press. Critical-size bone defects (Φ = 6 mm) were made in the cranial bones of 10-week-old Wistar rats, in which P-nHAP/COL and pressed collagen (P-COL) specimens were implanted. Defect-only samples (DEF) were also prepared. After the rats had been nourished for 3 days, 4 weeks, or 8 weeks, ossification of the cranial defects of the rats was evaluated by micro-computed tomography (micro-CT) (n = 6 each). Animals were sacrificed at 8 weeks, followed by histological examination. On micro-CT, the opacity of the defect significantly increased with time after P-nHAP/COL implantation (between 3 days and 8 weeks, p < 0.05) due to active bone regeneration. In contrast, with P-COL and DEF, the opacity increased only slightly with time after implantation, indicating sluggish bone regeneration. Histological inspections of the defect zone implanted with P-nHAP/COL indicated the adherence of multinucleated giant cells (osteoclasts) to the implant with phagocytosis and fragmentation of P-nHAP/COL, whereas active bone formation occurred nearby. Fluorescent double staining indicated dynamic bone-formation activities. P-nHAP/COL is strongly osteo-conductive and could serve as a useful novel bone substitute material for future dental implant treatments.

4.
Materials (Basel) ; 15(3)2022 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35161098

RESUMEN

Collagenous biomaterials that are clinically applied in dentistry have dermis-type and membrane-type, both of which are materials for promoting bone and soft tissue formation. The properties of materials supplied with different types could affect their biodegradation periods. The purpose of this study was to characterize five of these products by four different methods: scanning electron microscopy (SEM) observation, thermogravimetry-differential thermal analysis (TG-DTA), 0.01 wt% collagenase dissolution test, and subcutaneous implantation test in vivo. SEM micrographs revealed that both dermis and membranous materials were fibrous and porous. The membranous materials had higher specific derivative thermal gravimetry (DTG) peak temperatures in TG-DTA at around 320 °C, longer collagenase dissolution time ranging from about 300 to 500 min, and more longevity in mice exceeding 9 weeks than the dermis materials. There existed a correlation between the peak temperature in TG-DTA and the collagenase dissolution time. It was considered that higher cross-link degree among collagen fibrils of the membrane-type collagenous materials might account for these phenomena. The experimental protocol and numerical results obtained could be helpful for selection and future development of fibrous collagenous biomaterials in clinical use.

5.
J Oral Sci ; 63(4): 301-305, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34408111

RESUMEN

The recent literature on maxillary implant overdenture (IOD) was reviewed in order to clarify its predictability and establish treatment guidelines. Electronic searches were performed using PubMed, and articles about maxillary IOD written after 1990 were reviewed, focusing on the following items: I. implant survival rate, II. maxillary IOD survival rate, III. number of implants, IV. attachment type, V. follow-up period, VI. implant system, and VII. opposing dentition. The review revealed an implant survival rate of 61-100% and an overdenture survival rate of 72.4-100%. The attachments used included bars, balls, locators, and telescope crowns. The minimum and maximum observation periods were 12 months and 120 months, respectively, and the number of implants used for supporting IOD ranged from 2 to 8. At present, there is no strong evidence to indicate that maxillary IOD is clearly superior for all the items examined. However, the existing data indicate that maxillary IOD has almost the same therapeutic effect as fixed implant superstructures, and is a treatment option that can be actively adopted for patients in whom fixed superstructures cannot be applied for various reasons.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Retención de Dentadura , Prótesis de Recubrimiento , Humanos , Maxilar
6.
J Oral Sci ; 63(3): 212-216, 2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34078769

RESUMEN

This narrative review aims to provide an overview of recent studies and case reports on three-dimensional (3D) printing, and to verify the applicability of 3D printers in the field of dental prostheses. This review was performed by conducting a search of PubMed. The clinical application of fabricating a prosthesis made with cobalt-chromium is considered possible depending on the material and hardware of the 3D printer. However, it is currently difficult to assess the clinical use of 3D-printed zirconia crowns. Further research is required, such as verification of materials used, margin morphology, and hardware. Clinically acceptable results have been reported for patterns using 3D printers. Interim restorations made using a 3D printer have been reported with good results that are considered clinically usable. Dentures made with 3D printers need further verification in terms of strength and deformation. Custom trays made with 3D printers are clinically useful, however, issues remain with design time and effort. Although several studies have reported the usefulness of 3D printers, further verification is required since 3D printers are still considered new technology.


Asunto(s)
Impresión Tridimensional , Prostodoncia , Coronas
7.
J Oral Sci ; 62(2): 242-244, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32224576

RESUMEN

When the sinus is enlarged, it may be necessary to elevate the floor of the maxillary sinus using the crestal or lateral approach. This report presents a case where sinus floor elevation was performed using tricalcium phosphate (TCP) plates supported by implant bodies, and only the blood clot was present around the implant bodies. Cone-beam computed tomography images, taken one year after the lateral approach, revealed the presence of a TCP-like radio-opacity, which almost disappeared after two years. About seven years after the surgery, the patient's superstructure and occlusion were stable. Furthermore, the grafted TCP was completely absorbed, and the implant body appeared to be in good condition, with no signs of bone resorption around the implant.


Asunto(s)
Implantes Dentales , Elevación del Piso del Seno Maxilar , Fosfatos de Calcio , Tomografía Computarizada de Haz Cónico , Humanos , Seno Maxilar
8.
J Prosthodont Res ; 64(2): 109-113, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31474576

RESUMEN

PURPOSE: The digitization of the dental field has been vigorously promoted in recent years. An impression using an intraoral scanner is considered to significantly change future dental treatment. The purpose of this review is to evaluate accuracy and practicality of various intraoral scanners and verification method of intraoral scanners. STUDY SELECTION: This review was based on articles searched through the MEDLINE and PubMed databases. The main keywords that were employed during the search were "Oral Scanner, Intraoral Scanners, Desktop Scanner, and Digital Impression". RESULT: It was reported that illuminance and color temperature affected trueness and precision of intraoral scanners. The repeatability of intraoral scanners indicated the possibility of producing fixed prostheses within the range of being partially edentulous. It is considered difficult to use intraoral scanners in fabricating cross-arch fixed prostheses. However, with intraoral scanners, it may be considered possible to fabricate mouth guards and dentures equivalent to those of desktop scanners. Current intraoral scanner scans are considered more comfortable than traditional impressions that use irreversible hydrocolloid and elastomeric impression materials. CONCLUSION: Since the intraoral scanner is an evolving device, further improvement in accuracy is expected in the future. In addition, verification of the accuracy of intraoral scanners must be conducted accordingly.


Asunto(s)
Técnica de Impresión Dental , Modelos Dentales , Diseño Asistido por Computadora , Materiales de Impresión Dental , Diseño de Prótesis Dental , Imagenología Tridimensional
9.
J Prosthodont Res ; 64(2): 145-151, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31262659

RESUMEN

PURPOSE: To determine the appropriate attachment and design of a denture base for mandibular implant overdenture (IOD), the oral mucosa pressure caused by mandibular implant overdentures was measured using edentulous jaw models with various attachments. METHODS: An experimental edentulous mandibular model with a 1.5-mm thick artificial oral mucosa was used. Two implants were placed at the area equivalent to the bilateral canines of an experimental jaw model. Locator attachments (LA), ball attachments (BA), magnetic attachments (MA), and round-bar attachments (R-BA) were fabricated. Six miniature pressure sensors were placed at the bilateral buccal premolar regions, bilateral buccal shelves, and bilateral lingual molar regions. A precision universal testing machine was used to apply dynamic repetitive loads of 50N. The load points were the center of the model, which should represent bilateral mastication on both sides (bilateral load), and were equivalent to the left first molar, which should represent unilateral mastication (unilateral load). Statistical analysis was performed using one-way analysis of variance. Multiple comparisons were then performed using the Bonferroni post hoc test. P<0.05 was considered statistically significant. RESULTS: Under the bilateral load condition, the lower oral mucosa pressure value with BA was measured, compared to other attachments at all measurement sites. Under the unilateral load condition, the oral mucosa pressure value of BA was smaller than the other attachments at the measurement site on the loading side. CONCLUSIONS: BA has exerted the greatest effects on support and bracing, suggesting that, BA is suitable for reducing oral mucosa pressure during mastication.


Asunto(s)
Implantes Dentales , Prótesis de Recubrimiento , Prótesis Dental de Soporte Implantado , Retención de Dentadura , Mandíbula , Mucosa Bucal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...