1.
EJNMMI Rep ; 8(1): 6, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748042

RESUMEN

PURPOSE: To determine the efficacy and safety of target volume determination by 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) for intensity-modulated radiation therapy (IMRT) for locally advanced head and neck squamous cell carcinoma (HNSCC) extending into the oral cavity or oropharynx. METHODS: We prospectively treated 10 consecutive consenting patients with HNSCC using IMRT, with target volumes determined by PET-CT. Gross tumor volume (GTV) and clinical target volume (CTV) at the oral level were determined by two radiation oncologists for CT, magnetic resonance imaging (MRI), and PET-CT. Differences in target volume (GTVPET, GTVCT, GTVMRI, CTVPET, CTVCT, and CTVMRI) for each modality and the interobserver variability of the target volume were evaluated using the Dice similarity coefficient and Hausdorff distance. Clinical outcomes, including acute adverse events (AEs) and local control were evaluated. RESULTS: The mean GTV was smallest for GTVPET, followed by GTVCT and GTVMRI. There was a significant difference between GTVPET and GTVMRI, but not between the other two groups. The interobserver variability of target volume with PET-CT was significantly less than that with CT or MRI for GTV and tended to be less for CTV, but there was no significant difference in CTV between the modalities. Grade ≤ 3 acute dermatitis, mucositis, and dysphagia occurred in 55%, 88%, and 22% of patients, respectively, but no grade 4 AEs were observed. There was no local recurrence at the oral level after a median follow-up period of 37 months (range, 15-55 months). CONCLUSIONS: The results suggest that the target volume determined by PET-CT could safely reduce GTV size and interobserver variability in patients with locally advanced HNSCC extending into the oral cavity or oropharynx undergoing IMRT. Trial registration UMIN, UMIN000033007. Registered 16 jun 2018, https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000037631.

2.
J Radiat Res ; 65(3): 323-327, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38544297

RESUMEN

This study assessed the significance of hands-on-training (HoT) and questionnaire-based surveys on 3D image-guided brachytherapy (3D-IGBT) and a combination of intracavitary and interstitial brachytherapy, the so-called 'hybrid' BT (HBT), in uterine cervical cancer. In October 2023, 29 radiation oncologists, nurses, radiologic technologists and medical physicists from 10 Japanese facilities participated in an HoT on 3D-IGBT and HBT. Questionnaires were distributed to each participant before and after the HoT, and feedback was obtained through online channels. The questionnaire response rate was 83% (24/29), with at least one participant responding from each facility. 'Insertion of applicators and needles', 'human resource shortage' and 'pain relief and sedation' were the primary concerns of radiation oncologists. 'Applicator reconstruction', ' optimization of dwell positions', ' treatment planning' and ' human resource shortages ' were the primary concerns of radiological technologists and medical physicists. The HoT content was adjusted according to the results of preliminary surveys. The concerns expressed by the participants were addressed during the lectures and practical training. Significant reductions in anxiety were observed toward all items of the 10-point self-assessment after the HoT, regardless of the profession. The average score on satisfaction with the HoT (on a 10-point scale) was 9.52 (minimum of 8 and maximum of 10). In conclusion, HoT tailored in response to a pre-questionnaire-based survey effectively reduced participants' anxiety regarding the implementation of 3D-IGBT and HBT.


Asunto(s)
Ansiedad , Braquiterapia , Radioterapia Guiada por Imagen , Humanos , Encuestas y Cuestionarios , Femenino , Neoplasias del Cuello Uterino/radioterapia
3.
J Appl Clin Med Phys ; 25(5): e14305, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38368607

RESUMEN

PURPOSE: To elucidate the dosimetric errors caused by a model-based algorithm in lung stereotactic body radiation therapy (SBRT) with Helical TomoTherapy (HT) using Monte Carlo (MC)-based dose verification software. METHODS: For 38 plans of lung SBRT, the dose calculation accuracy of a treatment planning system (TPS) of HT was compared with the results of DoseCHECK, the commercial MC-based independent verification software. The following indices were extracted to evaluate the correlation of dosimetric errors: (1) target volume, (2) average computed tomography (CT) value of the planning target volume (PTV) margin, and (3) average CT value of surrounding 2-mm area of the PTV (PTV ring). Receiver operating characteristic (ROC) analyses determined the threshold for 5% of differences in PTV D95%. Then, the 38 plans were classified into two groups using the cutoff values of ROC analysis for these three indices. Dosimetric differences between groups were statistically compared using the Mann-Whitney U test. RESULTS: TPS of HT overestimated by more than 5% in the PTV D95% in 16 of 38 plans. The PTV ring showed the strongest correlation with dosimetric differences. The cutoff value for the target volume, the PTV margin, and the PTV ring was 14.7 cc, -754 HU, and -708 HU, respectively. The area under the curve (AUC) for the target volume, the PTV margin, and the PTV ring were 0.835, 0.878, and 0.932, respectively. Dosimetric errors more than 5% were observed when the PTV volume was less than 15 cc or when the CT value around the target was less than -700 HU. CONCLUSION: The TPS of HT might overestimate the PTV dose by more than 5% if any the three indices in this study were below threshold. Therefore, independent verification with an MC-based algorithm should be strongly recommended for lung SBRT in HT.


Asunto(s)
Algoritmos , Neoplasias Pulmonares , Método de Montecarlo , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Programas Informáticos , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Radiocirugia/métodos , Órganos en Riesgo/efectos de la radiación , Radiometría/métodos
4.
Esophagus ; 21(2): 111-119, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38294588

RESUMEN

BACKGROUND: Recurrent laryngeal nerve paralysis (RLNP) after esophagectomy can cause aspiration because of incomplete glottis closure, leading to pneumonia. However, patients with RLNP often have preserved swallowing function. This study investigated factors that determine swallowing function in patients with RLNP. METHODS: Patients with esophageal cancer who underwent esophagectomy and cervical esophagogastric anastomosis were enrolled between 2017 and 2020. Videofluoroscopic examination of swallowing study (VFSS) and acoustic voice analysis were performed on patients with suspected dysphagia including RLNP. Dysphagia in VFSS was defined as score ≥ 3 of the 8-point penetration-aspiration scale VFSS and acoustic analysis results related to dysphagia were compared between patients with and without RLNP. RESULTS: Among 312 patients who underwent esophagectomy, 74 developed RLNP. The incidence of late-onset pneumonia was significantly higher in the RLNP group than in the non-RLNP (18.9 vs. 8.0%, P = .008). Detailed swallowing function was assessed by VFSS in 84 patients, and patients with RLNP and dysphagia showed significantly shorter maximum diagonal hyoid bone elevation (10.62 vs. 16.75 mm; P = .003), which was a specific finding not seen in patients without RLNP. For acoustic voice analysis, the degree of hoarseness was not closely related to dysphagia. The length of oral intake rehabilitation for patients with and without RLNP was comparable if they did not present with dysphagia (8.5 vs. 9.0 days). CONCLUSIONS: Impaired hyoid bone elevation is a specific dysphagia factor in patients with RLNP, suggesting compensatory epiglottis inversion by hyoid bone elevation is important for incomplete glottis closure caused by RLNP.


Asunto(s)
Trastornos de Deglución , Neumonía , Parálisis de los Pliegues Vocales , Humanos , Trastornos de Deglución/epidemiología , Trastornos de Deglución/etiología , Deglución/fisiología , Esofagectomía/efectos adversos , Nervio Laríngeo Recurrente , Parálisis de los Pliegues Vocales/epidemiología , Parálisis de los Pliegues Vocales/etiología , Aspiración Respiratoria
5.
Radiol Phys Technol ; 17(1): 143-152, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37930563

RESUMEN

This study focused on the dosimetric impact of variations in respiratory motion during lung stereotactic body radiotherapy (SBRT). Dosimetric comparisons between volumetric modulated arc therapy (VMAT) and three-dimensional conformal radiotherapy (3DCRT) were performed using four-dimensional computed tomography (4DCT)-based internal target volumes (ITV). We created retrospective plans for ten patients with lung cancer who underwent SBRT using 3DCRT and VMAT techniques. A Delta4 Phantom + (ScandiDos, Uppsala, Sweden) was used to evaluate the dosimetric robustness of 4DCT-based ITV against variations in respiratory motion during treatment. We analyzed respiratory motion during treatment. Dose-volume histogram parameters were evaluated for the 95% dose (D95%) to the planning target volume (PTV) contoured on CT images obtained under free breathing. The correlations between patient respiratory parameters and dosimetric errors were also evaluated. In the phantom study, the average PTV D95% dose differences for all fractions were - 2.9 ± 4.4% (- 16.0 - 1.2%) and - 2.0 ± 2.8% (- 11.2 - 0.7%) for 3DCRT and VMAT, respectively. The average dose difference was < 3% for both 3DCRT and VMAT; however, in 5 out of 42 fractions in 3DCRT, the difference in PTV D95% was > 10%. Dosimetric errors were correlated with respiratory amplitude and velocity, and differences in respiratory amplitude between 4DCT and treatment days were the main factors causing dosimetric errors. The overall average dose error of the PTV D95% was small; however, both 3DCRT and VMAT cases exceeding 10% error were observed. Larger errors occurred with amplitude variation or baseline drift, indicating limited robustness of 4DCT-based ITV.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Humanos , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada Cuatridimensional/métodos , Estudios Retrospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Pulmón , Dosificación Radioterapéutica
6.
Brachytherapy ; 23(2): 115-122, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38040605

RESUMEN

PURPOSE: To evaluate the possibility of dose escalation and reduction of fraction number in cervical brachytherapy using a gel spacer. MATERIAL AND METHODS: Twenty patients with uterine cervical cancer treated with image-guided adaptive brachytherapy (IGABT) were selected. Hyaluronic acid gel injection (HGI) was performed in the rectovaginal and vesicouterine septum for 10 patients. The other ten patients were not with HGI. Both groups were treated with IGABT involving tandem/ovoid or cylindrical applicators along with additional interstitial needles. Dose distributions approved by radiation oncologists were retrospectively analyzed, and a dose summation of 45 Gy/25 of external beam radiation therapy and IGABT was performed. Dose constraints for D2cc of bladder, rectum, and sigmoid were 80, 70, and 70 Gy, respectively. Equivalent dose in 2-Gy fractions calculations used α/ß = 10 Gy for high-risk clinical target volume (CTVHR) D90 and α/ß = 3 Gy for organs at risks (OARs). As a planning study, dose distribution rescaling was conducted to deliver as much dose to CTVHR D90 as possible within the dose constraint limitation for OARs when IGABT was performed for four, three, and two fractions in both groups. RESULTS: The median CTVHR D90 was >80 Gy in the non-HGI group and >85 Gy in the HGI group for virtual two and three fractions. Rectum D2cc was significantly lower in the HGI group for three fractions (p < 0.01). CONCLUSIONS: In the HGI group, adequate dose delivery to CTVHR could be achieved with a reduced IGABT fraction number while meeting the dose constraints of OARs.


Asunto(s)
Braquiterapia , Neoplasias del Cuello Uterino , Femenino , Humanos , Dosificación Radioterapéutica , Braquiterapia/métodos , Estudios Retrospectivos , Neoplasias del Cuello Uterino/radioterapia , Recto , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador , Ácido Hialurónico
7.
Clin Transl Radiat Oncol ; 42: 100659, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37519921

RESUMEN

We first used MucoUp®, a hyaluronic acid used in endoscopic resection, as a spacer in brachytherapy. In five cervical cancer patients, MucoUp® insertion increased a 90% dose of the high-risk CTV to over 80 Gy while decreasing the dose of organs at risk. No related adverse events were observed.

8.
Dis Esophagus ; 36(10)2023 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-37183605

RESUMEN

Dysphagia after esophagectomy is a major risk factor for aspiration pneumonia, thus preoperative assessment of swallowing function is important. The maximum phonation time (MPT) is a simple indicator of phonatory function and also correlates with muscle strength associated with swallowing. This study aimed to determine whether preoperative MPT can predict postoperative aspiration pneumonia. The study included 409 consecutive patients who underwent esophagectomy for esophageal cancer between 2017 and 2021. Pneumonia detected by routine computed tomography on postoperative days 5-6 was defined as early-onset pneumonia, and pneumonia that developed later (most often aspiration pneumonia) was defined as late-onset pneumonia. The correlation between late-onset pneumonia and preoperative MPT was investigated. Patients were classified into short MPT (<15 seconds for males and <10 seconds for females, n = 156) and normal MPT groups (≥15 seconds for males and ≥10 seconds for females, n = 253). The short MPT group was significantly older, had a lower serum albumin level and vital capacity, and had a significantly higher incidence of late-onset pneumonia (18.6 vs. 6.7%, P < 0.001). Multivariate analysis showed that short MPT was an independent risk factor for late-onset pneumonia (odds ratio: 2.26, P = 0.026). The incidence of late-onset pneumonia was significantly higher in the short MPT group (15.6 vs. 4.7%, P = 0.004), even after propensity score matching adjusted for clinical characteristics. MPT is a useful predictor for late-onset pneumonia after esophagectomy.


Asunto(s)
Trastornos de Deglución , Neoplasias Esofágicas , Neumonía por Aspiración , Neumonía , Masculino , Femenino , Humanos , Neumonía/diagnóstico , Neumonía/epidemiología , Neumonía/etiología , Neumonía por Aspiración/diagnóstico , Neumonía por Aspiración/epidemiología , Neumonía por Aspiración/etiología , Trastornos de Deglución/diagnóstico , Trastornos de Deglución/epidemiología , Trastornos de Deglución/etiología , Fonación/fisiología , Neoplasias Esofágicas/complicaciones , Esofagectomía/efectos adversos , Estudios Retrospectivos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
9.
Phys Med ; 104: 112-122, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36395639

RESUMEN

PURPOSE: To investigate the scope of the effective clinical application of Monte Carlo (MC)-based independent dose verification software for helical tomotherapy. METHODS: DoseCHECK was selected as the MC-based dose calculation software. First, the dose calculation accuracy of DoseCHECK was evaluated with film and chamber measurements in a water-equivalent phantom. Second, the dose calculation accuracy was examined in several heterogeneous materials. Finally, dosimetric comparisons between DoseCHECK and the treatment planning system (TPS) were performed for clinical patient plans. Prostate IMRT, head and neck IMRT (HN), total body irradiation (TBI), and brain stereotactic radiotherapy (SRT) were evaluated. RESULT: The DoseCHECK calculations agreed with the chamber and film measurements in the homogenous phantom. For heterogeneous phantom cases, the dose differences between DoseCHECK and TPS were within 3 %, except in air, in which large dose differences of 20 % were observed. In clinical patient plans, the median dose differences between the lung Dmean in TBI cases and the normal brain Dmean in brain SRT cases were significantly >3 %. For HN and brain SRT cases, the median target dose differences were >3 %. CONCLUSION: Our results show that independent dose verification with the MC algorithm can detect systematic errors caused by the lack of heterogeneity correction in the TPS. In particular, MC-based independent dose verification is required for HN, TBI, and brain SRT cases in helical tomotherapy.

10.
Phys Med ; 100: 105-111, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35797917

RESUMEN

PURPOSE: We investigated the localization accuracy of the off-isocenter targets using SyncTraX FX4, a new image registration device. METHODS: In a phantom study, we used a MultiMet-WL Cube with metal targets at different distances from the isocenter. Image registrations were performed with SyncTraX and cone-beam computed tomography (CBCT). Nineteen fields with different gantry, collimator, and couch angles were delivered to each target. Localization errors of the off-isocenter targets were then evaluated. In a clinical study, localization accuracy was evaluated for 32 patients. First, image registration was performed using SyncTraX, and the accuracy of patient positioning was evaluated using CBCT. Next, positioning corrections were performed for intracranial setup errors exceeding the threshold (0.5 mm/0.5°) in each field. Finally, total setup uncertainty was evaluated using CBCT. Differences in dosimetric errors from planned doses between no patient positioning corrections during treatment and positioning corrections with SyncTraX were also evaluated. RESULTS: In the phantom study, the positioning accuracy on targets up to 7 cm from the isocenter was within 1 mm. In the clinical practice, the localization accuracies of SyncTraX were 0.35 ± 0.39 mm, 0.30 ± 0.24 mm, and 0.03 ± 0.27 mm in the lateral, vertical, and longitudinal directions, respectively. Post-treatment setup errors were reduced by correcting intrafractional setup errors with SyncTraX during treatment. Positioning corrections with SyncTraX reduced the maximum dosimetric error from 1.6% to 1.0%. CONCLUSIONS: SyncTraX provides satisfactory localization accuracy for the off-isocenter targets within 7 cm. SyncTraX reduce dosimetric errors caused by intrafractional setup errors during treatment.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Radiocirugia , Humanos , Fantasmas de Imagen , Radiometría , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos
11.
J Appl Clin Med Phys ; 22(9): 360-370, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34347933

RESUMEN

PURPOSE: We investigated the immobilization accuracy of a new type of thermoplastic mask-the Double Shell Positioning System (DSPS)-in terms of geometry and dose delivery. METHODS: Thirty-one consecutive patients with 1-5 brain metastases treated with stereotactic radiotherapy (SRT) were selected and divided into two groups. Patients were divided into two groups. One group of patients was immobilized by the DSPS (n = 9). Another group of patients was immobilized by a combination of the DSPS and a mouthpiece (n = 22). Patient repositioning was performed with cone beam computed tomography (CBCT) and six-degree of freedom couch. Additionally, CBCT images were acquired before and after treatment. Registration errors were analyzed with off-line review. The inter- and intrafractional setup errors, and planning target volume (PTV) margin were also calculated. Delivered doses were calculated by shifting the isocenter according to inter- and intrafractional setup errors. Dose differences of GTV D99% were compared between planned and delivered doses against the modified PTV margin of 1 mm. RESULTS: Interfractional setup errors associated with the mouthpiece group were significantly smaller than the translation errors in another group (p = 0.03). Intrafractional setup errors for the two groups were almost the same in all directions. PTV margins were 0.89 mm, 0.75 mm, and 0.90 mm for the DSPS combined with the mouthpiece in lateral, vertical, and longitudinal directions, respectively. Similarly, PTV margins were 1.20 mm, 0.72 mm, and 1.37 mm for the DSPS in the lateral, vertical, and longitudinal directions, respectively. Dose differences between planned and delivered doses were small enough to be within 1% for both groups. CONCLUSIONS: The geometric and dosimetric assessments revealed that the DSPS provides sufficient immobilization accuracy. Higher accuracy can be expected when the immobilization is combined with the use of a mouthpiece.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Errores de Configuración en Radioterapia , Encéfalo , Humanos , Inmovilización , Posicionamiento del Paciente , Errores de Configuración en Radioterapia/prevención & control
13.
J Appl Clin Med Phys ; 22(2): 108-117, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33426810

RESUMEN

This study evaluated unexpected dosimetric errors caused by machine control accuracy, patient setup errors, and patient weight changes/internal organ deformations. Trajectory log files for 13 gynecologic plans with seven- or nine-beam dynamic multileaf collimator (MLC) intensity-modulated radiation therapy (IMRT), and differences between expected and actual MLC positions and MUs were evaluated. Effects of patient setup errors on dosimetry were estimated by in-house software. To simulate residual patient setup errors after image-guided patient repositioning, planned dose distributions were recalculated (blurred dose) after the positions were randomly moved in three dimensions 0-2 mm (translation) and 0°-2° (rotation) 28 times per patient. Differences between planned and blurred doses in the clinical target volume (CTV) D98% and D2% were evaluated. Daily delivered doses were calculated from cone-beam computed tomography by the Hounsfield unit-to-density conversion method. Fractional and accumulated dose differences between original plans and actual delivery were evaluated by CTV D98% and D2% . The significance of accumulated doses was tested by the paired t test. Trajectory log file analysis showed that MLC positional errors were -0.01 ± 0.02 mm and MU delivery errors were 0.10 ± 0.10 MU. Differences in CTV D98% and D2% were <0.5% for simulated patient setup errors. Differences in CTV D98% and D2% were 2.4% or less between the fractional planned and delivered doses, but were 1.7% or less for the accumulated dose. Dosimetric errors were primarily caused by patient weight changes and internal organ deformation in gynecologic radiation therapy.


Asunto(s)
Neoplasias , Radioterapia de Intensidad Modulada , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
14.
Dis Esophagus ; 34(5)2021 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-33123720

RESUMEN

Dysphagia after esophagectomy is the main cause of a prolonged postoperative stay. The present study investigated the effects of a swallowing intervention led by a speech-language-hearing therapist (SLHT) on postoperative dysphagia. We enrolled 276 consecutive esophageal cancer patients who underwent esophagectomy and cervical esophagogastric anastomosis between July 2015 and December 2018; 109 received standard care (control group) and 167 were treated by a swallowing intervention (intervention group). In the intervention group, swallowing function screening and rehabilitation based on each patient's dysfunction were led by SLHT. The start of oral intake, length of oral intake rehabilitation, and length of the postoperative stay were compared in the two groups. The patient's subgroups in the 276 patients were examined to clarify the more effectiveness of the intervention. The start of oral intake was significantly earlier in the intervention group (POD: 11 vs. 8 days; P = 0.009). In the subgroup analysis, the length of the postoperative stay was also significantly shortened by the swallowing intervention in patients without complications (POD: 18 vs. 14 days; P = 0.001) and with recurrent laryngeal nerve paralysis (RLNP) (POD: 30 vs. 21.5 days; P = 0.003). A multivariate regression analysis identified the swallowing intervention as a significant independent factor for the earlier start of oral intake and a shorter postoperative stay in patients without complications and with RLNP. Our proposed swallowing intervention is beneficial for the earlier start of oral intake and discharge after esophagectomy, particularly in patients without complications and with RLNP. This program may contribute to enhanced recovery after surgery.


Asunto(s)
Trastornos de Deglución , Neoplasias Esofágicas , Deglución , Trastornos de Deglución/etiología , Neoplasias Esofágicas/complicaciones , Neoplasias Esofágicas/cirugía , Esofagectomía/efectos adversos , Humanos , Tiempo de Internación , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos
15.
J Oral Maxillofac Surg ; 75(7): 1530-1541, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28039737

RESUMEN

PURPOSE: Changes in acoustic features in the perioperative phase for elucidating the mechanisms of articulation disorder and the effect of perioperative rehabilitation were studied prospectively. MATERIALS AND METHODS: Sixty-two patients with 62 tongue cancer were divided into a partial glossectomy group (n = 40) and a reconstruction group (n = 22). Acoustic characteristics were analyzed during the preoperative and postoperative periods and after rehabilitation using the first and second formants of the vowels /a/, /i/, and /u/; the triangular vowel space area (tVSA); and the slopes of formant transitions. RESULTS: In the 2 groups, decreases in the tVSA and formant slopes were found from the preoperative to the postoperative period, and the acoustic characteristics of the reconstruction group especially improved to preoperative values after rehabilitation. Analysis of the postoperative period showed that acoustic characteristics were altered at the site of surgical resection. CONCLUSION: Changes of acoustic variables are related to excision size and site, suggesting the distinctive tongue portion for the articulation of each speech sound. Perioperative rehabilitation could activate the articulators and increase the range of movement of the remaining tongue, especially the preserved anterior tongue.


Asunto(s)
Trastornos de la Articulación/fisiopatología , Trastornos de la Articulación/rehabilitación , Glosectomía/rehabilitación , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/rehabilitación , Acústica del Lenguaje , Neoplasias de la Lengua/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Adulto Joven
16.
Eur Neurol ; 74(5-6): 251-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26624487

RESUMEN

BACKGROUND: Dysphagia due to bulbar involvement is a major symptom of patients with spinal and bulbar muscular atrophy (SBMA). The aim of this pilot study was to test the efficacy and safety of the head lift exercise for swallowing dysfunction in SBMA. METHODS: We enrolled 6 subjects with genetically confirmed SBMA and instructed them to perform the head lift exercise for 6 weeks. The efficacy outcome measures were the changes from baseline in tongue pressure, the scores of swallowing functional questionnaires, and the motor functional scales and parameters of videofluorography (VF). RESULTS: All subjects completed the study and no major adverse effects were recorded. Tongue pressure significantly increased by 19.2 ± 0.15% (p < 0.05) after the 6-week head lift exercise. The scores for oral dysphagia also improved, although there was no significant change in VF parameters or other variables examined pre- and post-exercise. CONCLUSION: Our findings suggested that the head lift exercise may improve swallowing dysfunction, particularly tongue pressure, in SBMA.


Asunto(s)
Trastornos de Deglución/terapia , Terapia por Ejercicio/métodos , Atrofia Muscular Espinal/terapia , Trastornos Musculares Atróficos/terapia , Adulto , Anciano , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Proyectos Piloto
SELECCIÓN DE REFERENCIAS