Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Radiol Med ; 124(5): 350-359, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30539411

RESUMEN

PURPOSE: To evaluate the image quality and radiation dose exposure of low-dose coronary CTA (cCTA) study, reconstructed with the new model-based iterative reconstruction algorithm (IMR), compared with standard hybrid-iterative reconstruction (iDose4) cCTA in patients with suspected coronary artery disease. MATERIALS AND METHODS: Ninety-eight patients with an indication for coronary CT study were prospectively enrolled. Fifty-two patients (study group) underwent 256-MDCT low-dose cCTA (80 kV; automated-mAs; 60 mL of CM, 350 mgL/mL) with prospective ECG-triggering acquisition and IMR. A control group of 46 patients underwent 256-MDCT standard prospective ECG-gated protocol (100 kV; automated-mAs; 70 mL of CM, 400 mgL/mL; iDose4). Subjective and objective image quality (attenuation value, SD, SNR and CNR) were evaluated by two radiologists subjectively. Radiation dose exposure was quantified as DLP, CTDIvol and ED. RESULTS: Mean values of mAs were significantly lower for IMR-cCTA (167 ± 62 mAs) compared to iDose-cCTA (278 ± 55 mAs), p < 0.001. With a significant reduction of 38% in radiation dose exposure (DLP: IMR-cCTA 91.7 ± 26 mGy cm vs. iDose-cCTA 148.6 ± 35 mGy cm; p value < 0.001), despite the use of different CM, we found higher mean attenuation values of the coronary arteries in IMR group compared to iDose4 (mean density in LAD: 491HU IMR-cCTA vs. 443HU iDose-cCTA; p = 0.03). We observed a significant higher value of SNR and CNR in study group due to a lower noise level. Qualitative analysis did not reveal any significant differences between the two groups (p = 0.23). CONCLUSIONS: Low-dose cCTA study combined with IMR reconstruction allows to correctly evaluate coronary arteries disease, offering high-quality images and significant radiation dose exposure reduction (38%), as compared to standard cCTA protocol.


Asunto(s)
Algoritmos , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Femenino , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Relación Señal-Ruido
2.
Br J Radiol ; 91(1092): 20170802, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30074831

RESUMEN

OBJECTIVE:: To evaluate image quality and radiation dose exposure of low-kV (100 kV) and low contrast medium (CM) volume CT angiography (CTA) in patients candidate to Transcatheter Aortic Valve Implantation (TAVI), in comparison with standard CTA protocol. METHODS:: 79 patients candidate for TAVI were prospectively enrolled in this study and examined with 256-MDCT. 42 patients were evaluated using study-group protocol (100 kV; whole-body retrospective ECG-gating; with 50 ml of CM; iterative reconstruction algorithm) while 37 patients underwent a standard CTA study (120 kV; ECG-gating for chest; 100 ml of CM; FBP reconstruction). Overall image quality was evaluated using a 4-point scale. Vascular enhancement (HU) was then assessed in each patient by manually drawing multiple ROIs in lumen of 7 segments of the whole aorta. The radiation dose exposure of both groups was calculated and all data were compared and statistically analyzed. RESULTS:: On low-kV protocol, higher mean attenuation values were achieved in all the measurements as compared to standard protocol. There were no significant differences in the image quality evaluation in both groups. Mean radiation dose value of study group was significantly lower than in control group (reduction of 20%). CONCLUSION:: Low kV and low CM volume CTA protocols allow TAVI planning to be carried out with high quality images and a significant reduction in the radiation dose as compared to the standard CTA protocol. ADVANCES IN KNOWLEDGE:: Low-kV CTA for pre-operative assessment of patients candidates for TAVI, permits to achieve a significant reduction of radiation dose exposure and contrast medium volume, reducing the risk of contrast induced nephropathy.


Asunto(s)
Algoritmos , Angiografía por Tomografía Computarizada/métodos , Dosis de Radiación , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...